Search NASA⌕ Search

SEARCH · Search NASA

Results for “wearable technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Fibrous Materials for Flexible Li–S Battery

The lithium–sulfur (Li–S) battery is an attractive high-energy-density technology for future flexible and wearable electronics, but it is a challenge to simultaneously realize adequate flexibility, stability, and energy density. Recent studies show that fibrous materials are promising to achieve flexible batteries with high energy density, by taking advantages of their intrinsic flexibility, lightweight, large surface area, and cost-effectiveness. With a good tunability of the structure and function, fibrous materials can be suitable to construct various components of a working battery, including current collectors, buffer layers, interlayers, and solid-state electrolytes. In this review, we summarize the recent development of fibrous materials for flexible Li–S batteries, with an emphasis on the discussion of the synthesis and preparation of materials, design of fibrous structures and functionalities, and layout of battery cells for achieving high Coulombic efficiency, long cycle life, and good flexibility.

25 ENERGY STORAGE↗

2012-2013 Delaware Valley Household Travel Survey

The 2012-2013 Delaware Valley Household Travel Survey collected data for multiple planning purposes such as the calibration of a new activity-based travel demand model. It features data from households across nine counties in the region, including southern New Jersey and southeastern Pennsylvania. The Delaware Valley Regional Planning Commission (DVRPC) sponsored the survey, which was administered by Abt Srbi Inc. A sampling strategy was designed to recruit households for survey participation that would best represent overall regional travel trends. Households were selected randomly, but with special consideration given to under-represented geographies and transit propensity. On their assigned travel day, households were asked to record all trips made within a 24-hour period. Additionally, select households were chosen to participate in a wearable global positioning system (GPS) technology-based component of the study. A total of 811 participants wore the GPS system.

1Hz data↗

2014 Southern Nevada Household Travel Survey

The 2014 Southern Nevada Household Travel Survey collected information from residents in the Las Vegas area to update the regional travel demand model and assess travel behavior. The Regional Transportation Commission of Southern Nevada contracted with Westat to conduct the survey. The survey was conducted in two phases—from March to May 2014 and from August to October 2014. Participants provided demographic and travel data (via a travel log). A 10% subsample (1,694 participants) was randomly selected to take part in a wearable global positioning system (GPS) technology-based component of the study, the purpose of which was to assess the level of trip under-reporting in the self-reported travel logs. Participants in the GPS portion of the study were instructed to record trips in their travel logs on the first day only, while passively recording their travel for three full days.

1Hz data↗

Size Effects in the Thermal Conductivity of Amorphous Polymers

Manipulating thermal conductivity through nanoengineering is of critical importance to advance technologies, such as soft robotics, artificial skin, wearable electronics, batteries, thermal insulation, and thermoelectrics. Here, by examining amorphous polymers, including polystyrene, polypropylene, polyethylene, and ethylene vinyl alcohol, using molecular dynamics simulations, we find that the thermal conductivities of amorphous polymers can be reduced below their amorphous limit by size effects. Size-dependent thermal transport in amorphous materials is decomposed into crystalline, crystalline-to-amorphous, and amorphous regimes. In the amorphous regime, the mean free path of propagating heat carriers can range from tens of nanometers to more than 100 nm, contributing 16%–36% of the total thermal conductivity. A two-channel model that combines no size effect (i.e., difusons and locons) and size effect (i.e., propagons) is proposed to account for size-dependent thermal conductivity. We also find that the presence of charged molecules in polymers can significantly affect the thermal conductivity and its size effects due to electrostatic interactions. Overall, this work provides insights into the thermal conductivity of amorphous polymers that will have a broad impact on the nano- and chemical engineering of polymers for various energy-related applications.

36 MATERIALS SCIENCE↗

Pre-Symptomatic COVID Screening

Temperature checks for fever are extensively used for preliminary COVID screenings but are ineffective during the incubation stage of infection when a person is asymptotic. Researchers at the European Centre for Disease Prevention and Control concluded that approximately 75% of passengers infected with COVID-19 and traveling from affected Chinese cities would not be detected by early screening. Core body temperature is normally kept within a narrow range and has the smallest relative standard deviation of all vital signs. Heat in the body is prioritized around internal organs at the expense of the periphery by controlling blood flow. In fact, blood flow to the skin may vary by a factor of 100 depending on thermal conditions. This adaptation causes rapid temperature fluctuations in different skin regions from changes in cardiac output, metabolism, and likely cytokine diffusion during inflammation that would not be seen in average core body temperature. Current IR and thermal scanners used for temperature checks are not necessarily reflective of core body temperatures and require cautious interpretation as they frequently result in false positive and false negative diagnosis. Hand held thermometers measure average skin temperatures and can get readings that differ from core body temperature by as much as 7°. Rather than focusing on a core body temperature threshold assessment we believe that variability of temperature patterns using a novel wearable transdermal microneedle sensor will be more sensitive to infections in the incubation stage and propose to develop a wearable transdermal temperature sensor using established Sandia microneedle technology for pre-symptomatic COVID screening that can additionally be used to monitor disease progression at later stages.

47 OTHER INSTRUMENTATION↗

Pre Symptomatic COVID Screening

Temperature checks for fever are extensively used for preliminary COVID screenings but are ineffective during the incubation stage of infection when a person is asymptotic. Researchers at the European Centre for Disease Prevention and Control concluded that approximately 75% of passengers infected with COVID-19 and traveling from affected Chinese cities would not be detected by early screening. Core body temperature is normally kept within a narrow range and has the smallest relative standard deviation of all vital signs. Heat in the body is prioritized around internal organs at the expense of the periphery by controlling blood flow. In fact, blood flow to the skin may vary by a factor of 100 depending on thermal conditions. This adaptation causes rapid temperature fluctuations in different skin regions from changes in cardiac output, metabolism, and likely cytokine diffusion during inflammation that would not be seen in average core body temperature. Current IR and thermal scanners used for temperature checks are not necessarily reflective of core body temperatures and require cautious interpretation as they frequently result in false positive and false negative diagnosis. Hand held thermometers measure average skin temperatures and can get readings that differ from core body temperature by as much as 7°. Rather than focusing on a core body temperature threshold assessment we believe that variability of temperature patterns using a novel wearable transdermal microneedle sensor will be more sensitive to infections in the incubation stage and propose to develop a wearable transdermal temperature sensor using established Sandia microneedle technology for pre symptomatic COVID screening that can additionally be used to monitor disease progression at later stages.

59 BASIC BIOLOGICAL SCIENCES↗

Variable Effects of Dispersed Nanoparticles on Triboelectric Nanogenerators

Technology has recently seen a drastic physical downsizing. Wearable and small devices with lower power demands have become the norm and continue to be more prominent in daily life. With modern devices growing smaller and requiring less electricity, a power source will always be needed. Contemporary batteries are the most common means to power small electronics. However, reliance on conventional batteries may prove insufficient due to the non renewable resources (Li, Ni, Co) required to power the growing number of individual devices each person may own. Additionally, the infrastructure required to harvest and recycle the sheer number of batteries produced presents a further logistic issue to be addressed. A promising alternative to batteries is the usage of triboelectric nanogenerators (TENGs). TENGs are a class of energy harvesting devices that utilize triboelectric generation to convert mechanical/kinetic energy into electrical energy and have exhibited efficiencies up to 85 % at low frequencies. TENGs exhibit a high voltage but low current. Even with the high voltage, the low current output proves to be a significant factor preventing undoped TENGs from being commercially viable. This review will investigate factors that increase the total current produced by TENGs when nanoparticles are utilized in TENGs. Factors such as increasing porosity, surface area, surface charge density, charge storage, deep trap formation, and dielectric constant can be altered to affect the total current by impregnating nanoparticles into the polymer material will be explored.

36 MATERIALS SCIENCE↗

Variable Effects of Dispersed Nanoparticles on Triboelectric Nanogenerators

Technology has recently seen a drastic physical downsizing. Wearable and small devices with lower power demands have become the norm and continue to be more prominent in daily life. With modern devices growing smaller and requiring less electricity, a power source will always be needed. Contemporary batteries are the most common means to power small electronics. However, reliance on conventional batteries may prove insufficient due to the non renewable resources (Li, Ni, Co) required to power the growing number of individual devices each person may own. Additionally, the infrastructure required to harvest and recycle the sheer number of batteries produced presents a further logistic issue to be addressed. A promising alternative to batteries is the usage of triboelectric nanogenerators (TENGs). TENGs are a class of energy harvesting devices that utilize triboelectric generation to convert mechanical/kinetic energy into electrical energy and have exhibited efficiencies up to 85 % at low frequencies. TENGs exhibit a high voltage but low current. Even with the high voltage, the low current output proves to be a significant factor preventing undoped TENGs from being commercially viable. This review will investigate factors that increase the total current produced by TENGs when nanoparticles are utilized in TENGs. Factors such as increasing porosity, surface area, surface charge density, charge storage, deep trap formation, and dielectric constant can be altered to affect the total current by impregnating nanoparticles into the polymer material will be explored.

42 ENGINEERING↗

A Smart System for the Contactless Measurement of Energy Expenditure

Energy Expenditure (EE) (kcal/day), a key element to guide obesity treatment, is measured from CO 2 production, VCO 2 (mL/min), and/or O 2 consumption, VO 2 (mL/min). Current technologies are limited due to the requirement of wearable facial accessories. A novel system, the Smart Pad, which measures EE via VCO 2 from a room’s ambient CO 2 concentration transients was evaluated. Resting EE (REE) and exercise VCO 2 measurements were recorded using Smart Pad and a reference instrument to study measurement duration’s influence on accuracy. The Smart Pad displayed 90% accuracy (±1 SD) for 14–19 min of REE measurement and for 4.8–7.0 min of exercise, using known room’s air exchange rate. Additionally, the Smart Pad was validated measuring subjects with a wide range of body mass indexes (BMI = 18.8 to 31.4 kg/m2), successfully validating the system accuracy across REE’s measures of ~1200 to ~3000 kcal/day. Furthermore, high correlation between subjects’ VCO 2 and λ for CO 2 accumulation was observed (p < 0.00001, R = 0.785) in a 14.0 m3 sized room. This finding led to development of a new model for REE measurement from ambient CO 2 without λ calibration using a reference instrument. The model correlated in nearly 100% agreement with reference instrument measures (y = 1.06x, R = 0.937) using an independent dataset (N = 56).

47 OTHER INSTRUMENTATION↗

Expanding the access of wearable silicone wristbands in community-engaged research through best practices in data analysis and integration

Wearable silicone wristbands are a rapidly growing exposure assessment technology that offer researchers the ability to study previously inaccessible cohorts and have the potential to provide a more comprehensive picture of chemical exposure within diverse communities. However, there are no established best practices for analyzing the data within a study or across multiple studies, thereby limiting impact and access of these data for larger meta-analyses. We utilize data from three studies, from over 600 wristbands worn by participants in New York City and Eugene, Oregon, to present a first-of-its-kind manuscript detailing wristband data properties. We further discuss and provide concrete examples of key areas and considerations in common statistical modeling methods where best practices must be established to enable meta-analyses and integration of data from multiple studies. Finally, we detail important and challenging aspects of machine learning, meta-analysis, and data integration that researchers will face in order to extend beyond the limited scope of individual studies focused on specific populations.

Bramer, Lisa M.↗

Data to Accompany: Expanding the access of wearable silicone wristbands in community-engaged research through best practices in data analysis and integration

Wearable silicone wristbands are a rapidly growing exposure assessment technology that offer researchers the ability to study previously inaccessible cohorts and have the potential to provide a more comprehensive picture of chemical exposure within diverse communities. However, there are no established best practices for analyzing the data within a study or across multiple studies, thereby limiting impact and access of these data for larger meta-analyses. We utilize data from three studies, from over 600 wristbands worn by participants in New York City and Eugene, Oregon, to present a first-of-its-kind manuscript detailing wristband data properties. We further discuss and provide concrete examples of key areas and considerations in common statistical modeling methods where best practices must be established to enable meta-analyses and integration of data from multiple studies. Finally, we detail important and challenging aspects of machine learning, meta-analysis, and data integration that researchers will face in order to extend beyond the limited scope of individual studies focused on specific populations.

Bramer, Lisa M↗

An implantable biomechanical energy harvester for animal monitoring devices

Insufficient service life and the resulting need for battery replacements have been a great challenge for implantable electronic devices. This is particularly true for animal tracking applications, because recapturing animals is often unlikely once they are released to the wild. To tackle this problem, we developed a biomechanical energy harvester that uses a Macro Fiber Composite™ (MFC) piezoelectric beam to harvest the mechanical energy from animals’ body bending movements as the power source for implantable and wearable devices. Prototypes of an underwater acoustic transmitter using this technology were subdermally implanted into juvenile white sturgeon and their energy harvesting performance was evaluated through the device’s transmissions. Additionally, the fish successfully recovered from the implantation surgery and freely swam inside a tank. The transmitter prototypes in the fish continually transmitted signals for a period up to 5 weeks. A benchtop test setup was also created to emulate the fish’s body bending, estimate the device’s energy harvesting performance in the live fish, and perform accelerated fatigue testing of the energy harvester by applying test parameters learned from a video study of the fish’s body movement and behavior characteristics. The gradual depolarization of the piezoelectric ceramic material in the MFC under cyclic mechanical loading was the main limiting factor for the life span of the energy harvester. Pathways for improvement are proposed to achieve long-term efficacy of powering implantable and wearable electronic devices.

42 ENGINEERING↗

Fueling the Future: The Emergence of Self-Powered Enzymatic Biofuel Cell Biosensors

Self-powered biosensors are innovative devices that can detect and analyze biological or chemical substances without the need for an external power source. These biosensors can convert energy from the surrounding environment or the analyte itself into electrical signals for sensing and data transmission. The self-powered nature of these biosensors offers several advantages, such as portability, autonomy, and reduced waste generation from disposable batteries. They find applications in various fields, including healthcare, environmental monitoring, food safety, and wearable devices. While self-powered biosensors are a promising technology, there are still challenges to address, such as improving energy efficiency, sensitivity, and stability to make them more practical and widely adopted. This review article focuses on exploring the evolving trends in self-powered biosensor design, outlining potential advantages and limitations. With a focal point on enzymatic biofuel cell power generation, this article describes various sensing mechanisms that employ the analyte as substrate or fuel for the biocatalyst’s ability to generate current. Technical aspects of biofuel cells are also examined. Research and development in the field of self-powered biosensors is ongoing, and this review describes promising areas for further exploration within the field, identifying underexplored areas that could benefit from further investigation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Subvoxel Control of Fiber Orientation via Multidirectional Shearing in 3D Printing

Anisotropy, the characteristic of materials exhibiting different properties based on their direction, is widespread in nature. Conventional manufacturing techniques often fall short in recreating such complex anisotropy. While 3D printing allows for precise fiber deposition in anisotropic composites, previous studies have only achieved bulk reorientation of fibers at the voxel level in two dimensions. This limits the replication of localized 3D anisotropies found in natural materials. To address this, a novel 3D printing technique is presented that enables subvoxel control of fiber orientation in all three directions using multidirectional shearing via nozzle rotation and inclination. The fiber orientation control in these experimental tests is driven by a numerical model, enabling a fully digital approach to program microstructures within a strand. This programmability is demonstrated through mechanical and thermal tests, illustrating a localized and controllable response to external stimuli. Achieving such complex anisotropy holds potential across several fields, including wearables and biomedical implants, lightweight composite structures, and energy storage technologies such as batteries and supercapacitors.

3D printing↗

Nucleation and Growth of Blue Phase 3D Cubic Structure Under Continuously Changing Curved Boundary Conditions

The blue phase of liquid crystals (BPLCs) with a cubic lattice of disclination lines and 3D nanostructure enables the modulation of photonic bandgap thus casting them in the category of photonic crystals. Its unique nature promises applications in display technologies, electro‐optics, and sensors. To integrate these ordered materials into wearable devices a fundamental understanding of curvature, and spatial confinement is necessary. Although continuous confinement in flat geometries have been studied, confining curvature has shown to induce strong destabilization effects on the cubic structure and formation of topological defects, thereby deteriorating their optical performance. Moreover, limitations in controlling the curvature of droplets further hinder studies of nucleation and growth of BPLCs. Here, to address these challenges, micro‐scale patterned surfaces of concentric cylinders are exploited to systematically control curvatures. The impact of curvature on the confined BPLCs is revealed in terms of phase transition temperature, nucleation and growth, morphology, as well as phase transformation. This research offers valuable insights into the stability, and structural characteristics of BPLCs in adaptive photonic devices, paving the way for future advancements in flexible displays, sensors, and other technologies leveraging liquid crystal (LC) materials.

3D Cubic Structure↗

Optimizing Patient-Specific Medication Regimen Policies Using Wearable Sensors in Parkinson’s Disease

Effective treatment of Parkinson’s disease (PD) is a continual challenge for healthcare providers, and providers can benefit from leveraging emerging technologies to supplement traditional clinic care. We develop a data-driven reinforcement learning (RL) framework to optimize PD medication regimens through wearable sensors. We leverage a data set of n = 26 PD patients who wore wrist-mounted movement trackers for two separate six-day periods. Using these data, we first build and validate a simulation model of how individual patients’ movement symptoms respond to medication administration. We then pair this simulation model with an on-policy RL algorithm that recommends optimal medication types, timing, and dosages during the day while incorporating human-in-the-loop considerations on medication administration. The results show that the RL-prescribed medication regimens outperform physicians’ medication regimens, despite physicians having access to the same data as the RL agent. To validate our results, we assess our wearable-based RL medication regimens using n = 399 PD patients from the Parkinson’s Progression Markers Initiative data set. We show that the wearable-based RL medication regimens would lead to significant symptom improvement for these patients, even more so than training RL policies directly from this data set. In doing so, we show that RL models from even small data sets of wearable data can offer novel, generalizable clinical insights and medication strategies, which may outperform those derived from larger data sets without wearable data.

60 APPLIED LIFE SCIENCES↗

Enabling Deformable and Stretchable Batteries

Abstract Deformable energy storage devices are needed to power next‐generation wearable electronics that interface intimately with human skin. Currently, deformable energy storage devices demonstrate poor performance compared to their rigid lithium‐ion counterparts, forcing wearable manufacturers to design their devices around bulky battery compartments. However, technological advances to create deformable batteries at the component and device level have yielded continuous improvement in stretchable batteries over the last five years. In this Essay, the major strategies at the component and device level that have been successfully employed to create stretchable batteries are reviewed. The outstanding challenges facing deformable energy storage are also discussed, namely, energy density, packaging, delamination, device integration, and manufacturing. This Essay will give researchers who are interested in contributing to the development of deformable batteries a cursory understanding of the most successful strategies to date, and provide insights into the most important directions to pursue in the future.

Mackanic, David G.↗

Non-invasive (non-contact) measurements of human thermal physiology signals and thermal comfort/discomfort poses -A review

Heating, ventilation and air-conditioning (HVAC) systems have been adopted to create comfortable, healthy and safe indoor environments. In the control loop, the technical feature of the human demand-oriented supply can help operate HVAC effectively. Among many technical options, real time monitoring based on feedback signals from end users has been frequently reported as a critical technology to confirm optimizing building performance. Recent studies have incorporated human thermal physiology signals and thermal comfort/discomfort status as real-time feedback signals. A series of human subject experiments used to be conducted by primarily adopting subjective questionnaire surveys in a lab-setting study, which is limited in the application for reality. With the help of advanced technologies, physiological signals have been detected, measured and processed by using multiple technical formats, such as wearable sensors. Nevertheless, they mostly require physical contacts with the skin surface in spite of the small physical dimension and compatibility with other wearable accessories, such as goggles, and intelligent bracelets. Most recently, a low cost small infrared camera has been adopted for monitoring human facial images, which could detect the facial skin temperature and blood perfusion in a contactless way. Also, according to latest pilot studies, a conventional digital camera can generate infrared images with the help of new methods, such as the Euler video magnification technology. Human thermal comfort/discomfort poses can also be detected by video methods without contacting human bodies and be analyzed by the skeleton keypoints model. Here, new sensing technologies were summarized, their cons and pros were discussed, and extended applications for the demand-oriented ventilation were also reviewed as potential development and applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗