Search NASA⌕ Search

SEARCH · Search NASA

Results for “widths”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Terrace width variations in complex Mercurian craters and the transient strength of cratered Mercurian and lunar crust

The effective cohesion of the cratered region during crater collapse is determined via the widths of slump terraces of complex craters. Terrace widths are measured for complex craters on Mercury; these generally increase outward toward the rim for a given crater, and the width of the outermost major terrace is generally an increasing function of crater diameter. The terrace widths on Mercury and a gravity-driven slump model are used to estimate the strength of the cratered region immediately after impact (about 1-2 MPa). A comparison with the previous study of lunar complex craters by Pearce and Melosh (1986) indicates that the transient strength of cratered Mercurian crust is no greater than that of the moon. The strength estimates vary only slightly with the geometric model used to restore the outermost major terrace to its precollapse configuration and are consistent with independent strength estimates from the simple-to-complex crater depth/diameter transition.

Leith, Andrew C.↗

Line widths of (N-14)H3 and (N-15)H3 applicable to planetary atmospheric observations

The collision-broadened half-widths of sP(1,0), sP(3,2), sP(4,1), sP(4,2), and sP(4,3) in the v2 sup s-fundamental bands of (N-14)H3 and (N-15)H3 have been measured at 198, 245, and 295 K employing the Doppler-limited spectral resolution of a tunable diode laser spectrometer. The temperature dependence of the collision-broadened half-widths of these lines broadened by H2 and N2 has been determined. In addition, we have also measured the air-broadened line widths of all of these lines at 295 K and the half-width of the sP(3,2) line of (N-15)H3 broadened by (N-14)H3 at 198, 245, and 295 K.

Varanasi, Prasad↗

Altitude Test Chamber Investigation of Performance of a 28-inch Ram-jet Engine II : Effects of Gutter Width and Blocked Area on Operating Range and Combustion Efficiency

Altitude-test-chamber investigation of effects of flame-holder blocked area and gutter width on performance of 28-inch diameter ram jet at simulated flight Mach number of 2.0 for altitudes from 40,000 to 55,000 feet was conducted at NACA Lewis laboratory. Ten flame holders investigated covered gutter widths from 1.00 to 2.50 inches and blocked areas from 40.5 to 62.0 percent of combustion-chamber area. Gutter width did not appreciably affect combustion efficiency. Increase in blocked area from 40 to 62 percent resulted in 5- to 10-percent increase in combustion efficiency. Increasing gutter width resulted in improvement in fuel-air-ratio operating range.

Shillito, T B↗

The width of the gamma-ray burst luminosity function

We examine the width of the gamma-ray burst (GRB) luminosity function through the distribution of GRB peak count rates, C(sub peak), as detected by Burst and Transient Source Experiment (BATSE) (1993). In the context of Galactic corona spatial distribution models, we attempt to place constaints on the characteristic width of the luminosity function by comparing the observed intensity distribution with those produced by a range of density and luminosity functions. We find that the intrinsic width of the luminosity function cannot be very well restricted. However, the distribution of intrinsic luminosities of detected bursts can be limited: we find that most observed bursts have luminosities that are in a range of one to two decades, but a significant population of undetected less luminous bursts cannot be excluded. These findings demonstrate that the assumption that GRB are standard candles is sufficient but not necessary to explain the observed intensity distribution. We show that the main reason for the relatively poor constraints is the fact that the bright-end part of the GRB flux distribution is not yet sampled by BATSE, and better sampling in the future may lead to significantly stronger constraints on the width of the luminosity function.

Ulmer, Andrew↗

Role of intrinsic width in fragment momentum distributions in heavy ion collisions

It is demonstrated that the intrinsic widths incorporating correlations in conjunction with dynamical contributions give better agreement with experiments for collisions in the energy range of 200 A MeV to 2.4 GeV than using only intrinsic widths without correlations. The sensitivity of the intrinsic width decreases with increasing projectile mass. A simple recipe for calculating intrinsic width correlations is presented.

Townsend, L. W.↗

Experimental Studies of Flutter of Buckled Rectangular Panels at Mach Numbers from 1.2 to 3.0 Including Effects of Pressure Differential and of Panel Width-Length Ratio

Experimental panel flutter data have been obtained at Mach numbers from 1.2 to 3.0 for buckled rectangular panels and the effect of a pressure differential has been determined. Increasing the pressure differential was effective in eliminating flutter on most of the panels tested. The effects of the variables in the panel flutter parameter ((square root of m(exp 2) -1) * (E/q))(exp 1/3) t/l (where M is the Mach number, q is the dynamic pressure, E is Young's modulus, and t and l are the panel thickness and length, respectively) were investigated for buckled panels clamped on the front and rear edges and a critical value of this parameter of 0.44 is indicated at zero pressure differential when the panel width-length ratio is 0.69. An estimated flutter boundary is presented for buckled panels clamped on four edges, with width-length ratios of 0.21 to 4.0. This boundary shows that the panel width is more significant than the panel length when the ratio of width to length is less than approximately 0.5. Panels clamped on four edges and buckled in two half waves in the direction of flow were found to be particularly susceptible to flutter. The results of limited tests on panels with applied damping, curvature, and lengthwise stiffeners are also presented and discussed.

Sylvester, Maurice A.↗

Effect of stance width on multidirectional postural responses

The effect of stance width on postural responses to 12 different directions of surface translations was examined. Postural responses were characterized by recording 11 lower limb and trunk muscles, body kinematics, and forces exerted under each foot of 7 healthy subjects while they were subjected to horizontal surface translations in 12 different, randomly presented directions. A quasi-static approach of force analysis was done, examining force integrals in three different epochs (background, passive, and active periods). The latency and amplitude of muscle responses were quantified for each direction, and muscle tuning curves were used to determine the spatial activation patterns for each muscle. The results demonstrate that the horizontal force constraint exerted at the ground was lessened in the wide, compared with narrow, stance for humans, a similar finding to that reported by Macpherson for cats. Despite more trunk displacement in narrow stance, there were no significant changes in body center of mass (CoM) displacement due to large changes in center of pressure (CoP), especially in response to lateral translations. Electromyographic (EMG) magnitude decreased for all directions in wide stance, particularly for the more proximal muscles, whereas latencies remained the same from narrow to wide stance. Equilibrium control in narrow stance was more of an active postural strategy that included regulating the loading/unloading of the limbs and the direction of horizontal force vectors. In wide stance, equilibrium control relied more on an increase in passive stiffness resulting from changes in limb geometry. The selective latency modulation of the proximal muscles with translation direction suggests that the trunk was being actively controlled in all directions. The similar EMG latencies for both narrow and wide stance, with modulation of only the muscle activation magnitude as stance width changed, suggest that the same postural synergy was only slightly modified for a change in stance width. Nevertheless, the magnitude of the trunk displacement, as well as of CoP displacement, was modified based on the degree of passive stiffness in the musculoskeletal system, which increased with stance width. The change from a more passive to an active horizontal force constraint, to larger EMG magnitudes especially in the trunk muscles and larger trunk and CoP excursions in narrow stance are consistent with a more effortful response for equilibrium control in narrow stance to perturbations in all directions.

Non-NASA Center↗

An Empirical Expression for the Line Widths of Ammonia

The hydrogen-broadened line widths of 116 (sup 14)NH(sub 3) ground state transitions have been measured at 0.006 cm(sup -1) resolution using a Bruker spectrometer in the 24 to 210 cm(sup -1) region. The rotational variation of the experimental widths with J(sup '),K(sup ') = 1,0 to 10,10 has been reproduced to 2.4 % using an heuristically derived expression of the form gamma = a(sub 0) + a(sub 1) J(sup ') + a (sub 2) K(sup ') + a(sub 3) J(sup ')(sup 2) + a(sub 4) J(sup ') K(sup ') where J(sup ') and K(sup ') are the lower state symmetric top quantum numbers. This function has also been applied to the measured widths of the 58 transitions of nu(sub 1) at 3 (micro)m, each broadened by N(sub 2), O(sub 2), Ar, H(sub 2), and He. The rms of the observed minus calculated widths are 5% or better for the five foreign broadeners. The values of the fitted constants suggest that for some broadeners the expression might also be written as gamma = a(sub 0) + b(sub 1) J(sup ') + b(sub 2)(J(sup ' )- K(sup ')) + b(sub 3) J(sup ')(J(sup ') - K(sup ')) .

ammonia spectroscopy planetary atmospheres hydroge↗

The CME Flare Arcade and the Width of the CME in the Outer Corona

Moore, Sterling, & Suess (2007, ApJ, 668, 1221) present evidence that (1) a CME is typically a magnetic bubble, a low-beta gplasmoid with legs h having roughly the 3D shape of a light bulb, and (2) in the outer corona the CME plasmoid is in lateral pressure equilibrium with the ambient magnetic field. They present three CMEs observed by SOHO/LASCO, each from a very different source located near the limb. One of these CMEs came from a compact ejective eruption from a small part of a sunspot active region, another came from a large quiet-region filament eruption, and the third CME, an extremely large and fast one, was produced in tandem with an X20 flare arcade that was centered on a huge delta sunspot. Each of these CMEs had more or less the classic lightbulb silhouette and attained a constant heliocentric angular width in the outer corona. This indicates that the CME plasmoid attained lateral magnetic pressure balance with the ambient radial magnetic field in the outer corona. This lateral pressure balance, together with the standard scenario for CME production by the eruption of a sheared-core magnetic arcade, yields the following simple estimate of the strength B(sub Flare) of the magnetic field in the flare arcade produced together with the CME: B(sub Flare) 1.4(theta CME/theta Flare)sup 2 G, where theta (sub CME) is the heliocentric angular width of the CME plasmoid in the outer corona and theta (sub Flare) is the heliocentric angular width of the full-grown flare arcade. Conversely, theta (sub CME) approximately equal to (R(sub Sun)sup -1(phi(sub Flare)/1.4)sup 1/2 radians, where Flare is the magnetic flux covered by the full-grown flare arcade. In addition to presenting the three CMEs of Moore, Sterling, & Suess (2007) and their agreement with this relation between CME and Flare, we present a further empirical test of this relation. For CMEs that erupt from active regions, the co-produced flare arcade seldom if ever covers the entire active region: if AR is the total magnetic flux of the active region, Flare . AR, and we predict that CME. (R(sub Sun))sup -1(theta AR/1.4)sup 1/2 radians. For a random sample of 31 CMEs that erupted from active regions within 30 of the limb, for each CME we have measured CME from LASCO/C3 and have measured AR from a SOHO/MDI magnetogram of the source active region when it was within 30 of disk center. We find that each CME obeys the above predicted inequality, none having width greater than half of the upper bound given by theta(sub AR). Thus, an active region's magnetic flux content, together with its location on the solar disk, largely determines whether the active region can possibly produce a CME that is wide enough to intercept the Earth.

Moore, Ron↗

A Hybrid Fiber/Solid-State Regenerative Amplifier with Tunable Pulse Widths for Satellite Laser Ranging

A fiber/solid-state hybrid seeded regenerative amplifier, capable of achieving high output energy with tunable pulse widths, has been developed for satellite laser ranging applications. The regenerative amplifier cavity uses a pair of Nd:YAG zigzag slabs oriented orthogonally to one another in order to make thermal lensing effects symmetrical and simplify optical correction schemes. The seed laser used is a fiber-coupled 1,064-nm narrowband (<0.02 nm) diode laser that is discretely driven in a new short-pulsed mode, enabling continuously tunable seed pulse widths in the 0.2-to-0.4-ns range. The amplifier gain unit consists of a pair of Brewster-cut 6-bounce zigzag Nd:YAG laser slabs, oriented 90deg relative to each other in the amplifier head. This arrangement creates a net-symmetrical thermal lens effect (an opposing singleaxis effect in each slab), and makes thermo-optical corrections simple by optimizing the curvature of the nearest cavity mirror. Each slab is pumped by a single 120-W, pulsed 808-nm laser diode array. In this configuration, the average pump beam distribution in the slabs had a 1-D Gaussian shape, which matches the estimated cavity mode size. A half-wave plate between the slabs reduces losses from Fresnel reflections due to the orthogonal slabs Brewster-cut end faces. Successful "temporal" seeding of the regenerative amplifier cavity results in a cavity Q-switch pulse envelope segmenting into shorter pulses, each having the width of the input seed, and having a uniform temporal separation corresponding to the cavity round-trip time of approx. =10 ns. The pulse energy is allowed to build on successive passes in the regenerative amplifier cavity until a maximum is reached, (when cavity gains and losses are equal), after which the pulse is electro- optically switched out on the next round trip The overall gain of the amplifier is approx. =82 dB (or a factor of 1.26 million). After directing the amplified output through a LBO frequency doubling crystal, approx. = 2.1 W of 532-nm output (>1 mJ) was measured. This corresponds to a nonlinear conversion efficiency of >60%. Furthermore, by pulse pumping this system, a single pulse per laser shot can be created for the SLR (satellite laser ranging) measurement, and this can be ejected into the instrument. This is operated at the precise frequency needed by the measurement, as opposed to commercial short-pulsed, mode-locked systems that need to operate in a continuous fashion, or CW (continuous wave), and create pulses at many MHz. Therefore, this design does not need to throw away or dump 99% of the laser energy to produce what is required; this system can be far smaller, more efficient, cheaper, and readily deployed in the field when packaged efficiently. Finally, by producing custom diode seed pulses electronically, two major advantages over commercial systems are realized: First, this pulse shape is customizable and not affected by the cavity length or gain of the amplifier cavity, and second, it can produce adjustable (selectable) pulse widths by simply adding multiple seed diodes and coupling each into commercial, low-cost fiber-optic combiners.

Coyle, Barry↗

Comparison of Trajectory Models in Calculations of N2-broadened Half-widths and N2-induced Line Shifts for the Rotational Band of H2O-16 and Comparison with Measurements

In this work, Complex Robert-Bonamy calculations of half-widths and line shifts were done for N2-broadening of water for 1639 transitions in the rotational band using two models for the trajectories. The first is a model correct to second order in time, the Robert-Bonamy parabolic approximation. The second is the solution of Hamilton's equations. Both models use the isotropic part of the atom-atom potential to determine the trajectories. The present calculations used an intermolecular potential expanded to 20th order to assure the convergence of the half-widths and line shifts. The aim of the study is to assess if the difference in the half-widths and line shifts determined from the two trajectory models is greater than the accuracy requirements of the spectroscopic and remote sensing communities. The results of the calculations are compared with measurements of the half-widths and line shifts. It is shown that the effects of the trajectory model greatly exceed the needs of current remote sensing measurements and that line shape parameters calculated using trajectories determined by solving Hamilton's equations agree better with measurement.

Lamouroux, J.↗

Shapes and widths of ammonia lines collision-broadened by hydrogen.

Measurement of half-widths and shapes of several rotational lines in nu sub 2 bands of ammonia, collision-broadened by hydrogen. The measurements were made at room temperature with a spectral resolution of 0.15 per cm. Line intensities and self-broadened half-widths were also measured. From the line-intensity data, an estimate of S sub band = 600 plus or minus 30 per sq cm per atm has been derived for the absolute intensity of the pair of bands. Hydrogen-broadened half-widths of all the lines have been found to be equal to 0.075 plus or minus 0.004 per cm per atm. For all the lines measured, shapes of the lines in NH3-H2 collisions seem to conform to the super-Lorenz line shape proposed by Varanasi et al. (1972) for dipole quadrupole collisions.

Varanasi, P.↗

Methane absorption in the Jovian atmosphere. I - The Lorentz half-width in the 3nu/sub 3/ band at 1.1 micron.

The Lorentz half-width alpha (L), of the fine-structure components of the methane 3nu/sub 3/ R-branch in the Jovian spectrum has been measured from photoelectric observations of the singlet R(1). Curves of growth for the 3nu/sub 3/ R-branch manifolds have been calculated, using the measured value of alpha (L) and assuming a reflecting-layer atmosphere. The Walker-Hayes (1967) equivalent widths have been reanalyzed for rotational temperature and methane abundance. The half-width derived here is significantly different from a similar measurement made by Farmer (1969). The source of the discrepancy remains obscure.

Bergstralh, J. T.↗

Effects of intrinsic region width in Si/Li/ p-i-n diodes

Description of certain effects related to the width of the intrinsic region produced in a silicon p-i-n diode by lithium ion drifting. It is found that for wider intrinsic regions at large forward biases there is a larger ohmic drop across the region and a correspondingly smaller current. Moreover, the recovery time decreases with increasing intrinsic region width. Conversely, the decay phase time increases with increasing intrinsic region width and with increasing current levels.

Harman, T. L.↗

Measurement of line widths of CO of planetary interest at low temperatures

Self-broadened, air-broadened and CO2-broadened half-widths of lines R(0) through R(16) in the CO fundamental have been measured at 100 K (self-broadening only), 200 K, 250 K and 300 K using the Ladenburg-Reiche curve-of-growth. The relation which we found previously for the nitrogen-broadened half-widths of R(0), R(8), and R(16), is shown to be valid for all of the line widths measured in the present study.

Varanasi, P.↗

Optically thick line widths in pyrotechnic flares

Experimentally determined sodium line widths for pyrotechnic flares are compared with simple analytical, optically-thick-line-shape calculations. Three ambient pressure levels are considered (760, 150 and 30 torr) for three different flare compositions. The measured line widths range from 1.3 to 481 A. The analytic procedure emphasizes the Lorentz line shape as observed under optically-thick conditions. Calculated widths are in good agreement with the measured values over the entire range.

Douda, B. E.↗

Shift and width measurements of the Stark-broadened ionized helium line at 1215 A

Time-resolved photoelectric measurements were made of the shifts of helium plasma lines at 1640 A and 1215 A and of the Stark profile of the 1215 A line, using an electromagnetic shock tube as a light source. These red shifts are consistent with a plasma polarization shift, where the interaction energy between the radiating ion and the perturbing plasma electrons corresponds to the Coulomb interaction near the excited state Bohr radius. No significant shifts were observed for the 1640 A line, while the 1215 A line underwent a red shift of about 0.5 A. The measured Stark width of the 1215 A line was 10-45% greater than the calculated width based on the measured width of the 4686 A line.

Van Zandt, J. R.↗