Search NASA⌕ Search

SEARCH · Search NASA

Results for “wood building”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Chemical composition of material extractives influences microbial growth and dynamics on wetted wood materials

The impact of material chemical composition on microbial growth on building materials remains relatively poorly understood. We investigate the influence of the chemical composition of material extractives on microbial growth and community dynamics on 30 different wood species that were naturally inoculated, wetted, and held at high humidity for several weeks. Microbial growth was assessed by visual assessment and molecular sequencing. Unwetted material powders and microbial swab samples were analyzed using reverse phase liquid chromatography with tandem mass spectrometry. Different wood species demonstrated varying susceptibility to microbial growth after 3 weeks and visible coverage and fungal qPCR concentrations were correlated (R 2 = 0.55). Aspergillaceae was most abundant across all samples; Meruliaceae was more prevalent on 8 materials with the highest visible microbial growth. A larger and more diverse set of compounds was detected from the wood shavings compared to the microbial swabs, indicating a complex and heterogeneous chemical composition within wood types. Several individual compounds putatively identified in wood samples showed statistically significant, near-monotonic associations with microbial growth, including C 11 H 16 O 4 , C 18 H 34 O 4 , and C 6 H 15 NO. A pilot experiment confirmed the inhibitory effects of dosing a sample of wood materials with varying concentrations of liquid C 6 H 15 NO (assuming it presented as Diethylethanolamine).

59 BASIC BIOLOGICAL SCIENCES↗

Big Box Retail Grocery Store and Electric Vehicle Station Load Profiles

This dataset includes yearlong, one-minute resolution time series profiles for the big box retail grocery stores stores simulated in Phoenix, Houston, Denver, and Minneapolis, as well as electric vehicle charging time series profiles for the various ports, charging levels, and station utilizations produced for the study "Impact of electric vehicle charging on the power demand of retail buildings", published in 2021 (https://doi.org/10.1016/j.adapen.2021.100062). Please cite as: Gilleran, M., Bonnema, E., Woods, J. et al. Impact of electric vehicle charging on the power demand of retail buildings. Advances in Applied Energy 4, (2021). https://doi.org/10.1016/j.adapen.2021.100062

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Best of Both Worlds: Combined Thermal and Battery Storage for Widespread Building Decarbonization

To meet 2050 decarbonization targets, widespread building electrification is a critical complement to clean power generation. Behind-the-meter storage (BTMS) (e.g., battery electric energy storage [EES] and thermal energy storage [TES]) integrated with buildings or building end uses to store and supply energy at optimal times can minimize burdens associated with operation, planning, and upgrades to the electrical grid sometimes triggered by building electrification. Such BTMS systems can serve the dual purpose of providing enhanced resilience at the building and grid level, and support the deployment of renewable generation needed for wide-scale decarbonization. While TES can cost-effectively shed and shift thermal loads, it cannot generally backup or shift non-thermal building end uses. EES, by contrast, is more expensive, but applicable to all end uses (i.e., thermal and electrical loads). Combined together, these storage systems can be traded off against one another to perform optimally in meeting demand flexibility, decarbonization goals, and energy resilience of the buildings at a lower total system cost. This paper proposes a framework to define BTMS benefits, provides four illustrative electrification scenarios using TES and EES, and discusses the combined TES/EES benefits with building energy modeling results. The paper also highlights potential barriers to adoption of BTMS and a path forward.

buildings↗

A Two-Way Spinoff

Gougeon Brothers, Inc. successfully applied their boat building expertise to a NASA problem in wind turbine development. NASA and the department of Energy began experimenting with large wind turbine machines as an energy alternative to fossil fuels. During the development of a first generation wind turbine generator known as MOD-OA, Lewis Research Center faced the problem of supersize rotor blades made of metal that kept failing under stress. Using the techniques they had developed for fabricating wood composite structures, the Gougeon Brothers went on to build several sets of blades for the MOD-OA system; all worked successfully. Gougeon Brothers acquired new know-how during the course of studying rotor blade aerodynamics which they applied to their boat building. They developed the innovative "aerodynamic mast" for sailboats. Their mast, a strong, lightweight wood composite which needs no supporting rigging and is free to rotate with the wind, could cut a ship's fuel cost by as much as 40 percent.

Source record↗

Directing Assembly of Mesoscale Multi‐Shell Morphologies of DNA Origami Crystals

Nature builds hierarchically ordered materials, such as seashells, wood, and bones, through spatially and temporally regulated growth. Mimicking such a level of control in synthetic systems remains challenging, particularly in achieving multiscale organizations with prescribed nanoscale arrangements and desired material morphologies. In this study, we introduce a DNA-based self-assembly strategy for constructing diverse multi-shell mesoscale morphologies from nanoscale lattices, enabling prescribed structural, and compositional 3D material patterns. Using DNA origami frames as modular monomers, we direct anisotropic epitaxial growth through addressable DNA frame binding motifs and encapsulate nanoparticles (NPs) in desired 3D patterns. Sequential monomer addition under thermodynamically favorable conditions enables shell growth through heterogeneous nucleation while minimizing unwanted homogeneous nucleation. Here, we demonstrate that DNA-encoded addressability enables epitaxial shell growth along specific lattice directions, yielding crystals with multilayered mesoscale organization, including tube-like (sushi roll) and plate-like (macaron) morphologies. Shell-specific NP configurations and compositions are achieved through addressable and differentiated placement of NPs within each shell, as validated by small-angle x-ray scattering and cross-sectional scanning transmission electron microscopy. We further demonstrate addressable NP release and reveal that shells modulate release kinetics. Together, these findings establish a platform for fabricating DNA origami crystals with programmable mesoscale morphologies, nanoscale structure, composition, and transport properties.

3D patterning↗

Propagation measurements for satellite radio reception inside buildings

Swept CW signals (from 700 to 1800 MHz) were received inside six buildings of brick, corrugated sheet-metal, wood-frame, mobile-home, and reinforced concrete-wall construction. A transmitter antenna was mounted outdoors on top of an 18 m tower to simulate a satellite, and a linearly scanned directional receiver antenna was used to probe the spatial, spectral, and temporal variability of the signal indoors. Levels were found to have much structure in the spatial and frequency domain, but were relatively stable in time. Typically, people moving nearby produced variations of less than 0.5 dB, whereas a person blocking the transmission path produced fades of 6 to 10 dB. Severe losses (17.5 dB) were observed in the concrete-wall building, which also exhibited the longest multipath delays (over 100 ns). Losses inside a mobile home were even larger (over 20 dB) and were independent of antenna orientation. The power-frequency distortion increased with the logarithm of the bandwidth, but could be reduced by moving to a position of higher power. Only the losses showed a clear frequency dependence, but they could be mitigated by moving the antenna.

Vogel, Wolfhard J.↗

Design and performance evaluation of a dual-circuit thermal energy storage module for air conditioners

We present experimental results and a validated numerical model of a dual-circuit phase-change thermal energy storage module for air conditioners. The module incorporates a phase-change material encapsulated in compressed expanded natural graphite foam. We used n-tetradecane as the PCM with a transition temperature (~4.5 °C) suitable for air-conditioning applications. Heat exchange to and from the module is accomplished through two fluid loops operating as a heat source and sink embedded inside multiple slabs of the composite material. This dual-circuit design enables easier integration with air-conditioning equipment and provides enhanced flexibility in system operation as compared to the state-of-the-art thermal storage systems. When integrated with an air-conditioner, this design will enable peak-load shaving and enhances operational efficiency. The thermal storage device was designed for a nominal storage capacity of ~ 3.5 kWh. We evaluated the heat transfer and energy storage performance of this device using standalone heat transfer experiments to estimate key thermal resistances and identify design improvements before integration with an air conditioner. The numerical model of the heat exchanger uses a combination of discretized and lumped parameter approaches to maintain a balance between accuracy and computational expense. Our analyses show that the geometric features and integration of fluid tubes are key contributors to the thermal contact resistance between the fluid and the thermal storage material, and consequently, to the overall performance of the thermal storage module. Our standalone experiments also identified important operating scenarios in which this thermal storage module can be used for air-conditioning in buildings.

25 ENERGY STORAGE↗

Study and prototype of data system interactions for the Earth Observing System Data and Information System

A crucial part of the Earth Observing System (EOS) is its Data and Information System (EOSDIS). The success of EOS depends not only on its instruments and science studies, but also on its ability to help scientists integrate data sets of geophysical and biological measurements taken by various instruments and investigators. NASA contractors have completed Phase B studies of EOSDIS, in particular its architecture, functionality, and user interfacing. At this point in time, it may seem impossible to exercise the EOSDIS or any of its components since they do not exist; i.e., if the EOSDIS is accepted as a totally new system, distinct from any existing DIS. However, if EOSDIS is seen as evolving from existing data systems, then some limited prototyping studies can be conducted by using currently functioning systems. In support of both the EOSDIS Science Advisory Panel and the EOSDIS Project, a prototyping activity was carried out by a cross section of interdisciplinary scientists. That prototyping activity is summarized and some conclusions are drawn that can be used by NASA-Goddard to evaluate and modify the specifications soon to be released in an RFP to build EOSDIS.

Emmitt, G. D.↗

Carbon intensity of mass timber materials: impacts of sourcing and transportation

Mass timber construction is widely considered a promising alternative construction method to reduce buildings’ total life-cycle carbon emissions because wood is a carbon sink. Cross-laminated timber (CLT) panels, manufactured by gluing lumber layers with grains at right angles, are potential low-carbon alternatives to carbon-intensive concrete and steel construction. However, most environmental impact assessment studies do not consider variation in transportation impacts within the CLT supply chain when calculating life-cycle impacts. This study investigates the embodied primary energy and the global warming potential (GWP) of CLT supply chain decisions regarding the type of timber species used, the U.S. region it is sourced from, and the location of the CLT mill. Longer transport distances in the supply chain for timber and CLT panels can contribute as much as 923 MJ/m 2 (20%) of the embodied primary energy of a CLT building, and the use of a higher-density timber species increases this contribution to 1246 MJ/m 2 (24%), with most of that energy derived from fossil energy sources. For perspective, the GWP of a building whose CLT panels and timber have been transported by truck over 6,000 km (252–270 kgCO 2 /m 2 ) is greater than the GWP of an equivalent reinforced concrete (RC) building (245 kgCO 2 /m 2 ). Thus, factors like the location of CLT processing facilities and the type of timber species can significantly impact the overall life-cycle assessment and, if chosen appropriately, can mitigate the environmental impacts of CLT construction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The hygrothermal performance of continuous and cavity wood fiber insulation

Wood fiber insulation is an emerging material known for its effective thermal performance and moisture management properties, making it a compelling alternative to conventional insulation. Its vapor permeability and ability to regulate indoor humidity contribute to improved building durability and comfort, particularly in varying climate conditions. The goal of this project is to characterize the hygrothermal performance of a new wood fiber insulation product line in U.S. climate zones and to facilitate the design and construction of the product in residential and light commercial building envelopes. This study investigates the thermal and hygrothermal performance of wood fiber insulation, both as continuous and cavity insulation. The research employs an exhaustive simulation task and an environmental chamber test of a wood fiber insulation. Over 400 simulations were conducted to study the hygrothermal characteristics of bio-based wood fiber insulation in various building envelope configurations across four climate zones. Environmental chamber tests were conducted under controlled winter conditions representative of Climate Zone 5A (Chicago, IL) to complement the simulation results. The chamber tests focused on the hygrothermal performance of the wood fiber insulation and the sheathing board to assess the insulation's ability to manage moisture in a cold climate. Simulation and environmental chamber test results were analyzed to evaluate the insulation's consistency and efficacy across diverse climatic zones. Results show that with a proper moisture control strategy, both cavity and continuous wood fiber insulation can work properly in both new and retrofit constructions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Hygrothermal Performance of Continuous and Cavity Wood Fiber Insulation

Wood fiber insulation is an emerging material known for its effective thermal performance and moisture management properties, making it a compelling alternative to conventional insulation. Its vapor permeability and ability to regulate indoor humidity contribute to improved building durability and comfort, particularly in varying climate conditions. The goal of this project is to characterize the hygrothermal performance of a new wood fiber insulation product line in U.S. climate zones and to facilitate the design and construction of the product in residential and light commercial building envelopes. This study investigates the thermal and hygrothermal performance of wood fiber insulation, both as continuous and cavity insulation. The research employs an exhaustive simulation task and an environmental chamber test of a wood fiber insulation. Over 400 simulations were conducted to study the hygrothermal characteristics of bio-based wood fiber insulation in various building envelope configurations across four climate zones. Environmental chamber tests were conducted under controlled winter conditions representative of Climate Zone 5A (Chicago, IL) to complement the simulation results. The chamber tests focused on the hygrothermal performance of the wood fiber insulation and the sheathing board to assess the insulation's ability to manage moisture in a cold climate. Simulation and environmental chamber test results were analyzed to evaluate the insulation's consistency and efficacy across diverse climatic zones. Results show that with a proper moisture control strategy, both cavity and continuous wood fiber insulation can work properly in both new and retrofit constructions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Life-cycle carbon footprint and total production potential of cross-laminated timber from California’s wildland-urban interface

The frequency, scale, and severity of wildfires are steadily increasing in the Western United States. Sustainable forest management practices through forest thinning could reduce the impact of wildfires and provide lumber for wood-based, long-lived, and low-carbon building materials. This study explores the potential for harvesting biomass in California (CA) to mitigate wildfire risk and provide multi-decade carbon storage in the form of cross-laminated timber (CLT) for use in buildings. First, we assessed biomass resource availability, finding that the total live hardwood and live softwood available in the wildland-urban interfaces (WUIs) across CA sums to 14.1 million metric tons (MMT) and 34.9 MMT, respectively, which contains the equivalent of 90 MMT of atmospheric carbon dioxide. Then, we conducted a life cycle assessment of CLT considering softwood and hardwood sources to provide insights into emissions and energy demand associated with utilization of the wood removed for wildfire risk management. We found that the net life cycle carbon footprint of live hardwood and softwood when including biogenic carbon storage/emissions is 414 and 317 kg CO2e/m3 CLT, respectively. To incorporate the timing of these emissions and uptake, we have also conducted a cradle-to-grave time-dependent global warming potential (GWP) analysis. The time-adjusted GWP for live hardwood and live softwood is −227 and −104 kg CO2e/m3 CLT, respectively. In terms of total CLT production potential, 0.03 and 0.005 million m3 CLT can be sourced from live softwood and hardwood, respectively, in WUI on gentle slopes in CA. The resulting insights and approaches from this study are broadly applicable to other forested regions and WUIs across the US and the world, and provide a holistic approach to use forest thinning as a wildfire mitigation strategy in combination with a novel approach for life cycle assessment of building materials with a limited dataset.

Bose, Baishakhi↗

Assessing Methodologies for Detecting Water Intrusion in Wall Systems: Phase 2

Studies by the University of Florida, the Environmental Protection Agency (EPA) and the U.S. Department of Housing (HUD) have revealed that there is a substantial fraction of commercial and residential buildings that have been exposed to moisture resulting in damage or durability problems. Water intrusion into building envelope components leads to a variety of undesirable conditions such as mold, wood rot, corrosion, and aesthetic damage. Tests methods that are presently used to evaluate the amount of water intrusion into a building envelope component are usually qualitative in nature. For example, ASTM E 331, Standard Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference requires that you “observe and record points of water leakage, if any.” This test was originally developed to assess the performance of fenestration products but is commonly adapted to evaluate other enclosure assemblies. However, when it is typically used for walls, this procedure is limited to recognizing if the moisture is visually observable from the backside side of the sheathing. It does not address moisture that is absorbed in the layers of the building envelope component, which could impact the durability of the assembly. Clearly a quantitative means of determining water penetration would improve the quality of this type of test and assist with better understanding the resultant impact on enclosure assemblies. In 2018-20, Oak Ridge National Laboratory, in conjunction with the Air Barrier Association of America, initiated a research project to address this issue. The purpose of that study was to evaluate nine different methods of detecting moisture intrusion through a wall assembly. air and water barrier. The wall assemblies included metal frame construction faced with gypsum sheathing and both self-adhered and fluid applied air and water barriers (AWB) were evaluated for this exercise. This project did not test the efficacy of the different AWBs, rather, fasteners were purposely installed in various ways to foster water penetration and activate the different methods of detection. Each detection method was evaluated for five features that included simplicity of use, cost of implementation, whether the method was quantitative or subjective, accuracy, and applicability. A scale of green/yellow/red was used to assess each feature where green was acceptable, yellow was borderline, and red was not to be pursued at this time. This report covers additional research that has been undertaken to extend the activities initiated in this earlier project with refinements for specific detection methods and considerations for expansion related to field versus laboratory testing standards.

42 ENGINEERING↗

Satellite sound broadcast propagation measurements

Power transmitted from atop a 17.9 m tower in simulation of a satellite signal, emitted by a tone generator sweeping from 700 to 1800 MHz, was received using a 90 deg beamwidth linearly scanning antenna at many locations inside six buildings of solid brick, corrugated sheet-metal, wood-frame, mobile home, and concrete wall construction. The signal levels are found to have much structure in the spatial and frequency domain but were relatively stable in time. Typically, people moving nearby produced less than 0.5 dB variations, whereas a person blocking the transmission path produces 6 to 10 dB fades. Losses, which at an average position in a room increased from 6 to 12 dB over 750 to 1750 MHz, could be mitigated to 2 to 6 dB by moving the antenna typically less than 30 cm. Severe losses (17.5 dB, mitigated to 12.5 dB) were observed in a concrete wall building, which also exhibited the longest multipath delays (greater than 100 ns). Losses inside a mobile home were even larger (greater than 20 dB) and independent of antenna orientation. The losses showed a clear frequency dependence.

Vogel, Wolfhard J.↗

The Circular Home: Development and Demonstration of a Net Negative Carbon, Reusable Residence

This project started the development of an innovative modular building system intended for residential construction. The project was centered around single-family homes that were carbon-negative cradle-to-grave over a 100 year time frame, which is approximately double the current standard for operational life. The project sought to accomplish this objective by designing the modular home in a manner that ensures circularity, where the main house components can be used over several consecutive 50-year lifespans. To accomplish these objectives, this project utilized integrated design with the inclusion of life-cycle assessment to design the single-family house for architectural, structural, energy, mechanical, thermal, and moisture demands, while ensuring carbon negativity and annual net-zero energy use. The core technology of this project was the use of cross-laminated timber and biogenic materials, such as wood-fiber insulation, in the construction of the modular building units. The robustness and factory manufacturing ability of cross-laminated timber allow for factory construction of most of the home, which minimizes on-site time, saving money and reducing construction waste. During this project, initial milestones were met that delivered the architectural plans for the circular home and an initial structural testing matrix. Compared to current code-built homes, which average 13 kg CO2eq. / ft2 and are demolished at their end of life, the circular home has an estimated -30 kg CO2eq. / ft2 of embodied carbon emissions during its first build iteration. It is estimated that approximately 60%-70% of the total building mass could be reused and/or recycled during subsequent rebuilds. This project was concluded at approximately the 1/3 point and a separate project was established to conclude the remaining milestones. This project promises to benefit the public by delivering another option for single-family, and eventually multi-family, housing using a novel building construction system. The system of reusable modular construction facilitates not only lower emissions during the first building iteration, but also lower emissions during subsequent iterations that drastically reduce waste and help society meet its climate goals. Many other industries, such as clothing and technology sectors, are starting to focus on circularity and this project adds the residential building construction industry to that list.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Gaussian Kernel Methods for Seismic Fragility and Risk Assessment of Mid-Rise Buildings

Seismic fragility functions can be evaluated using the cloud analysis method with linear regression which makes three fundamental assumptions about the relation between structural response and seismic intensity: log-linear median relationship, constant standard deviation, and Gaussian distributed errors. While cloud analysis with linear regression is a popular method, the degree to which these individual and compounded assumptions affect the fragility and the risk of mid-rise buildings needs to be systematically studied. This paper conducts such a study considering three building archetypes that make up a bulk of the building stock: RC moment frame, steel moment frame, and wood shear wall. Gaussian kernel methods are employed to capture the data-driven variations in the median structural response and standard deviation and the distributions of residuals with the intensity level. With reference to the Gaussian kernels approach, it is found that while the linear regression assumptions may not affect the fragility functions of lower damage states, this conclusion does not hold for the higher damage states (such as the Complete state). In addition, the effects of linear regression assumptions on the seismic risk are evaluated. For predicting the demand hazard, it is found that the linear regression assumptions can impact the computed risk for larger structural response values. However, for predicting the loss hazard with downtime as the decision variable, linear regression can be considered adequate for all practical purposes.

58 GEOSCIENCES↗

Assessing the Use of SAR/Optical Data Fusion and TensorFlow for Improved Mangrove Mapping

Mangrove forests are found in intertidal zones of tropical regions around the world and provide important ecological and economic benefits – they are considered carbon sequesters, habitats for flora and fauna, and natural barriers to hurricanes and tsunamis. Wood from mangrove forests are used as fuel and building materials in surrounding coastal communities, therefore promoting local livelihoods. Despite the importance of these ecosystems, mangrove forests have historically been degraded in natural processes such as severe weather, and anthropogenic factors like conversion to agriculture and aquaculture. This study assesses change in mangrove forests in Nigeria and Mozambique from 2015 to 2018 using SAR and optical data fusion. Due to frequent cloud cover over the study area, SAR and optical data is fused to obtain gap-free imagery without clouds. Landsat-8 OLI and Sentinel-1 imagery is fused with TensorFlow, an open source platform used in developing machine learning models. The resulting images are classified to discriminate mangrove forest cover from other land cover types, and change is estimated using image differencing. Understanding the rates and magnitude of mangrove change across space and time can aid in identifying priority areas for forest regeneration, and can help construct sustainable management practices for the future.

Strattman, Katherine↗