Search NASA⌕ Search

SEARCH · Search NASA

Results for “x-ray absorption spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Spectral variability in the X-ray pulsar GX 1+4

Observations of the galactic center region, hard X-ray source GX 1+4 by the GSFC X-ray spectroscopy experiment on OSO-8 confirm that GX 1+4 is a slow X-ray pulsar. The amount of absorption by cold matter in the spectrum of GX 1+4 varies significantly within a 24 hour period, behavior typical of many X-ray binary systems. The light curve for the pulsations from GX 1+4 appears to be energy dependent.

Becker, R. H.↗

Spectral variability in the X-ray pulsar GX 1 + 4

Observations of the galactic-center-region hard X-ray source GX 1 + 4 by the GSFC X-ray spectroscopy experiment on OSO-8 confirm that GX 1 + 4 is a slow X-ray pulsar. The amount of absorption by cold matter in the spectrum of GX 1 + 4 varies significantly within a 24-hour period, which is typical of many X-ray binary systems. The light curve for the pulsations from GX 1 + 4 appears to be energy-dependent.

Becker, R. H.↗

Thermal detectors as X-ray spectrometers

Sensitive thermal detectors should be useful for measuring very small energy pulses, such as those produced by the absorption of X-ray photons. The measurement uncertainty can be very small, making the technique promising for high resolution nondispersive X-ray spectroscopy. The limits to the energy resolution of such thermal detectors are derived and used to find the resolution to be expected for a detector suitable for X-ray spectroscopy in the 100 eV to 10,000 eV range. If there is no noise in the thermalization of the X-ray, resolution better than 1 eV full width at half maximum is possible for detectors operating at 0.1 K. Energy loss in the conversion of the photon energy to heat is a potential problem. The loss mechanisms may include emission of photons or electrons, or the trapping of energy in long lived metastable states. Fluctuations in the phonon spectrum could also limit the resolution if phonon relaxation times are very long. Conceptual solutions are given for each of these possible problems.

Moseley, S. H.↗

Thermal detectors as X-ray spectrometers

Sensitive thermal detectors should be useful for measuring very small energy pulses, such as those produced by the absorption of X-ray photons. The measurement uncertainty can be very small, making the technique promising for high resolution nondispersive X-ray spectroscopy. The limits to the energy resolution of such thermal detectors are derived and used to find the resolution to be expected for a detector suitable for X-ray spectroscopy in the 100 eV to 10,000 eV range. If there is no noise in the thermalization of the X-ray, resolution better than 1 eV full width at half maximum is possible for detectors operating at 0.1 K. Energy loss in the conversion of the photon energy to heat is a potential problem. The loss mechanisms may include emission of photons or electrons, or the trapping of energy in long lived metastable states. Fluctuations in the phonon spectrum could also limit the resolution if phonon relaxation times are very long. Conceptual solutions are given for each of these possible problems.

Moseley, S. H.↗

A portable x-ray analyzer for wearmetal particles in lubricants

An extensive program exists for the systematic sampling and analysis of lubricants in U.S. Air Force aircraft engines. The sudden development of excessive engine wear can usually be detected on the basis of monitoring the concentration of several key metallic elements for each aircraft engine. In many cases even the specific fault within an engine can be recognized. The two types of equipment which are currently being employed for the conduction of oil analyses make use of atomic emission or atomic absorption spectroscopy. In both cases, heavy, large, and relatively fragile pieces of equipment are involved. Difficulties concerning the transportation of these devices have led to the development of a small, sturdy, and easily portable wearmetal analyzer. The analyzer makes use of an X-ray fluorescence technique.

Clark, B. C.↗

X-ray and UV spectroscopy of Cygnus X-1 = HDE226868

Observations are presented of Cygnus X-1 with the solid-state spectrometer on the Einstein Observatory. The X-ray spectra of two intensity dips viewed near superior conjunction did not exhibit increased photoelectric absorption. Rather the data support a model in which an increase in the electron scattering optical depth modifies both the observed spectrum and the intensity. The characteristic temperature of the intervening material is greater than 5 x 10 to the 7th power K. These measurements were in part simultaneous with observations by IUE. The ultra violet spectrum and intensity remained relatively constant during an X-ray intensity dip.

Pravdo, S. H.↗

X-ray and ultraviolet spectroscopy of Cygnus X-1 = HDE 226868

Observations of Cygnus X-1 with the solid-state spectrometer on the Einstein Observatory are presented. The X-ray spectra of two intensity dips viewed near superior conjunction did not exhibit increased photoelectric absorption. Rather, the data support a model in which an increase in the electron-scattering optical depth modifies both the observed spectrum and the intensity. The characteristic temperature of the intervening material is greater than about 50 million K. These measurements were in part simultaneous with observations by IUE. The ultraviolet spectrum and intensity remained relatively constant during an X-ray intensity dip.

Pravdo, S. H.↗

Proportional counter for X-ray analysis of lunar and planetary surfaces

A position sensitive proportional scintillation detector was developed and evaluated for use in applications involving X-ray imaging as well as spectroscopy. Topics covered include limitations of the proportional scintillation counter for use in space; purification of the xenon gas in the detector, and the operation of the detector system. Results show that the light signal in a proportional scintillation detector remains well localized. With modest electric fields in xenon, the primary electrons from a photoelectric absorption of an X-ray can be brought a distance of a few millimeters to a higher field region without spreading more than a millimeter or so. Therefore, it is possible to make a proportional scintillation detector with good position sensitivity that could be used to calibrate out the difference in light collection over its sensitive volume.

Source record↗

Interaction of hydrogen chloride with alumina

The influence of temperature, pressure, and outgas conditions on the absorption of hydrogen chloride and water vapor on both alpha and gamma alumina was studied. Characterization of the adsorbents was performed using X-ray powder diffraction, scanning electron microscopy (SEM), low temperature nitrogen adsorption desorption measurements, BET nitrogen surface area measurements and electron spectroscopy for chemical analysis (ESCA). Water vapor adsorption isotherms at 30, 40, and 50 C were measured on alpha and gamma alumina after outgassing at 80, 200, and 400 C. Both outgas temperature and adsorption temperature influenced the adsorption of water vapor on the aluminas. The water vapor adsorption was completely reversible. Alpha alumina absorbed more water per unit area than gamma alumina. Differences in the adsorption capacity for water vapor of the two aluminas were explained on the basis of ideal surface models of alpha and gamma alumina. Isosteric heats of adsorption for water vapor on the aluminas were determined over a limited range of surface coverage.

Bailey, R. R.↗

Soft X-ray spectroscopy of three extragalactic sources

Soft X-ray spectra (0.5 to 5 KeV) acquired with a rocket-borne argon-methane proportional counter are reported for M87, 3C 273, and NGC 4151. The counter sensitivity range allowed derivation of simultaneous information on the magnitude of soft X-ray absorption and the slope of the hard X-ray spectrum. Error estimation techniques for the free parameters of X-ray spectra are analyzed, and the results are applied to the spectra previously reported for these sources. It is shown that the technique used to analyze the previous spectra can drastically underestimate the magnitude of errors, and it is concluded that the proposed division of extragalactic X-ray sources into two groups according to the magnitude of absorption in their spectra is premature.

Margon, B.↗

Cosmic X-ray observations with OSO-8

The GSFC Cosmic X-ray Spectroscopy experiment aboard OSO-8 has operated successfully since launch providing spectral and temporal data on X-ray sources in tha energy range 2-60 keV. Analysis of quick look data shows a variety of spectral features, some stable, others variable, which will increase understanding of the nature of individual sources. In particular, observed emission and absorption features that can be attributed to iron will result in abundance measures of this important element in sources such as some X-ray binaries, the supernova remnant Cas A, and the nucleus of the galaxy Cen A.

Serlemitsos, P. J.↗

X ray spectra of X Per

The cosmic X-ray spectroscopy experiment on OSO-8 observed X Per for twenty days during two observations in Feb. 1976 and Feb. 1977. The spectrum of X Per varies in phase with its 13.9 min period, hardening significantly at X-ray minimum. Unlike other X-ray binary pulsar spectra, X Per's spectra do not exhibit iron line emission or strong absorption features. The data show no evidence for a 22 hour periodicity in the X-ray intensity of X Per. These results indicate that the X-ray emission from X Per may be originating from a neutron star in a low density region far from the optically identified Be star.

Becker, R. H.↗

X-ray spectra of X Persei

The GSFC cosmic X-ray spectroscopy experiment on OSO 8 observed X Per for 20 days during two observations in 1976 February and 1977 February. The spectrum of X Per varies in phase with its 13.9 minute period, hardening significantly at X-ray minimum. Unlike other X-ray binary pulsar spectra, those of X Per do not exhibit iron line emission or strong absorption features. Our data show no evidence for a 22 hour periodicity in the X-ray intensity of X Per. These results indicate that the X-ray emission from X Per may be originating from a neutron star in a low-density region far from the optically identified Be star.

Becker, R. H.↗

Accretion powered X-ray pulsars

The current theoretical understanding of the properties of X-ray pulsars is assessed through a comparison with unified descriptions of 14 such systems, extending over six orders of magnitude in luminosity, in whose phase averaged spectra the only notable trend is a less abrupt high energy cutoff in the lower luminosity systems. Detailed pulse phase spectroscopy is given for five of the systems. A reexamination of the pulse phase spectra of 4U 0115 + 63 has uncovered electron cyclotron lines at 11.5 and 23 keV that appear to be in absorption at pulse peak and in emission during an interpulse. Spectral hardening regions such as those from Her X-1 are a common feature in the low energy pulse of many pulsars, and may represent the passage of the magnetic axis through the observer's line of sight. Attention is given to the nature of the beaming from Her X-1, and it is concluded that a pencil beam configuration represents the simplest explanation of the overall properties of the pulse.

White, N. E.↗

X-ray photometry and spectroscopy of T Tauri stars

Follow-up Einstein X-ray observations of four fields containing pre-main-sequence stars are presented. A search has been made for evidence of variability on time scales of hours and of 1 year. A large, slow flare in AS 205, and the X-ray disappearance of AA Tau are reported. Otherwise, T Tauri stars appear no more variable in X-rays than do active solar-like stars. An attempt has been made to determine spectral parameters for a number of the brighter sources. X-ray absorption column densities are consistent with those inferred from A(v), and T(x) of about 10-million K, in all cases. The importance of these observations for models of T Tauri stars and their coronae is considered.

Walter, F. M.↗

Phase resolved optical spectroscopy of the compact X-ray binary 2A1822-371

The optical, X-ray, and ultraviolet emissions of the X-ray system 2A1822-371 are modulated with a period of 5.57 hr. The 5.57 hr modulation is believed to reflect orbital motion about a mass donating companion star. The modulation at high energies is caused by the combined effects of an occultation by the companion and by a bulge on the accretion disk. The present investigation is concerned with an extension of the study of 2A1822-371, taking into account medium resolution optical spectroscopy of the system covering the 5.57 hr cycle. Broad shallow absorption lines are observed in the optical spectrum of 2A1822-371. These lines are similar to the rotationally broadened lines which are found in the spectra of disk accreting cataclysmic variables. Their presence in 2A1822-371 is, therefore, strong confirmation that it is a disk accreting star. The He II 4686 A and H-alpha emission lines have a breadth comparable to the absorption lines at all phases in the 5.57 hr cycle.

Mason, K. O.↗

Observations of Absorption Lines from Highly Ionized Atoms

In the ultraviolet spectra of hot stars, absorption lines can be seen from highly ionized species in the interstellar medium. Observations of these features which have been very influential in revising the perception of the medium's various physical states, are discussed. The pervasiveness of O 6 absorption lines, coupled with complementary observations of a diffuse background in soft X-rays and EUV radiation, shows that there is an extensive network of low density gas (n approx. fewX 0.001/cucm) existing at coronal temperatures, 5.3 or = log T or = 6.3. Shocks created by supernova explosions or mass loss from early-type stars can propagate freely through space and eventually transfer a large amount of energy to the medium. To create the coronal temperatures, the shocks must have velocities in excess of 150 km/sec; shocks at somewhat lower velocity 9v or = 100 km/sec) can be directly observed in the lines of Si3. Observations of other lines in the ultraviolet, such as Si 4V and C 5, may highlight the widespread presence of energetic uv radiation from very hot, dward stars. More advanced techniques in visible and X-ray astronomical spectroscopy may open up for inspection selected lines from atoms in much higher stages of ionization.

Jenkins, E. B.↗

Stellar crystal X-ray spectroscopy on OSO-8

The large-area graphite crystal X-ray spectrometer on the OSO-8 satellite is described, and its response to stellar line and continuum radiation is discussed. A high resolution X-ray spectrum of Sco X-1 obtained from a preliminary analysis of quick look data shows a strong, smooth continuum with an absence of emission or absorption features over the energy range 2.2 to 8 keV. Upper limits are set on narrow line emission from highly ionized states of S, Ca, and Fe.

Kestenbaum, H. L.↗