Search NASA⌕ Search

SEARCH · Search NASA

Results for “xenon isotopes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Spectrum of carbonaceous-chondrite fission xenon

Estimations of the fission spectrum in xenon isotopes from the progenitor of the strange carbonaceous-chondrite xenon must take account of p-process nucleosynthesis if the latter is the source of anomalous Xe-124, 126. Sample calculations of the p-process yields illustrate the magnitude of the effect, which can greatly increase the estimated Xe-132 fission yield.

Clayton, D. D.↗

Comets and carbonaceous chondrites delivered noble gases to the Moon

Trapped xenon isotopes in two Apollo 17 mare basalt fragments are similar to those in primitive meteorites. Xenon would have been effectively excluded from the Moon in the aftermath of its formation in a giant impact. As such, lunar mantle xenon trapped in the mare basalts is best explained as being derived from late accretion occurring before or concurrent with the formation of the lunar crust. Here, the isotopic composition indicates that a combination of comets and carbonaceous chondrites delivered this xenon to the lunar mantle. The inferred mass of accreted cometary ice would have delivered significantly less than a part per million of water to the lunar mantle. The inferred mass of accreted carbonaceous chondrites would have supplied at least a half of a part per million of water. The data further indicate that enstatite chondrites are unlikely to have supplied the majority of late accreted mass.

Chemistry↗

Measurements of radioxenon activities during periods of gaseous release from an advanced gas-cooled reactor

Activities of radioxenon isotopes are reported from an Advanced Gas-cooled Reactor (AGR) during periods of gaseous release. Xenon isotopes are relevant to the monitoring regime of the Comprehensive Nuclear-Test-Ban Treaty (CTBT). These releases may affect detections from the International Monitoring System (IMS) by influencing the radioxenon background. Time series activity plots have been produced from both in-core monitoring and direct measurement at the point of release using a stack monitor system. Ratio plots using both data sets have been produced with results compared with a commonly chosen nuclear explosion “discrimination line.” The reported results improve the understanding of radionuclide emissions from civil nuclear power plants. This work is being performed as part of the Xenon Environmental Nuclide Analysis at Hartlepool (XENAH) collaboration between the Atomic Weapons Establishment (AWE, UK), EDF Energy (UK), Pacific Northwest National Laboratory (PNNL, USA), and the Swedish Defence Research Agency (FOI).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Alternative hypothesis for the origin of CCF xenon

The relative abundances and origins of the xenon isotopes found in carbonaceous meteorites are discussed. It is proposed that carbonaceous-chondrite-fission (CCF) xenon is not caused by fission, but is the direct result of a modified r-process nucleosynthesis which produces a peak at Z = 54 and N = 82. The xenon produced in this way would have been trapped in dust grains which were subsequently incorporated in the solar system with minimal degassing.

Black, D. C.↗

Direct Simulation Monte Carlo Studies of the Gas Sampling for the VATMOS-SR Mission Concept

VATMOS-SR (Venus ATMOSpheric - Sample Return) is a small spacecraft mission concept which would return a gas sample from the upper atmosphere of Venus to Earth for scientific analysis. This could be the first sample return mission for an extra-terrestrial atmosphere, and potentially the first sample return from an Earth-sized planet. The VATMOS-SR mission concept consists of a SmallSat atmospheric sampling probe (45 deg. sphere/cone geometry, <1 m diameter) that is designed to skim through the Venus upper atmosphere and acquire gas samples below the homopause altitude (around ~110 km altitude), where the different atmospheric gases are mixed. The velocity of the spacecraft where sampling would occur is expected to be between ~10.5 km/s and ~13.1 km/s, depending on the trajectory chosen. This presentation will discuss hypervelocity sampling in the upper atmosphere of Venus, with respect to the VATMOS-SR mission concept. VATMOS-SR would enable critical atmospheric measurements to form a full picture of how, why, and when Venus evolved to be so different from Earth and Mars. The abundances and isotopic compositions of volatile elements (such as N, C, S, O and the noble gases) in planetary atmospheres record volatile delivery during accretion, outgassing from planetary interiors, and atmospheric loss to space. Precise and accurate determinations of atmospheric volatile signatures are the key to understanding the origins and geodynamical evolution of Venus compared to the other terrestrial planets. Hypersonic sampling poses unique technical and scientific challenges. To ensure it is possible to relate the composition of the sampled gases to the free stream atmospheric composition, large-scale numerical simulations are employed to model the flow through the VATMOS-SR sampling system. In particular, an emphasis is placed on quantifying noble gas isotopic fractionation that occurs during the sample acquisition and transfer process in order to determine how measured isotopic ratios of noble gases in the sample compare to actual isotopic ratios in the Venusian atmosphere. The Direct Simulation Monte Carlo (DSMC) code SPARTA, an open source software package developed by Sandia National Laboratories, is used in this work. SPARTA, based on Bird’s DSMC method, is a molecular-level gas-kinetic technique. As SPARTA is able to model hypervelocity reacting flows in strong chemical and thermal non-equilibrium, this software package is well suited to determine relevant flow properties for the VATMOS-SR mission concept, and to numerically quantify the expected level of elemental and/or isotopic fractionation in the sample acquired by VATMOS-SR. This presentation will show results from 3D simulations correlating the noble gas isotopic fractionation in the gas acquired at hypervelocity speeds to its ambient atmosphere value. In particular, emphasis will be placed at Xenon isotopes of masses 128 and 130, as precise measurements of that ratio would yield a comparison to Earth’s atmosphere. Additionally, sensitivity studies that quantify the uncertainties due to the freestream parameters as well as the modeling parameters will be performed.

direct simulation Monte Carlo↗

The VATMOS-SR Mission Concept: DSMC Studies of the Gas Sampling

VATMOS-SR (Venus ATMOSpheric - Sample Return) is a small spacecraft mission concept that would return a gas sample from the upper atmosphere of Venus to Earth for scientific analysis. This could be the first sample return mission for an extra-terrestrial atmosphere and potentially the first sample return from an Earth-sized planet. The VATMOS-SR mission concept consists of a SmallSat atmospheric sampling probe (45 deg. sphere/cone geometry, <1 m diameter) that is designed to skim through the Venus upper atmosphere and acquire gas samples below the homopause altitude (around ~110 km altitude), where the different atmospheric gases are mixed. The velocity of the spacecraft where sampling would occur is expected to be between ~10.5 km/s and ~13.1 km/s, depending on the trajectory chosen. This presentation will discuss hypervelocity sampling in the upper atmosphere of Venus with respect to the VATMOS-SR mission concept. VATMOS-SR would enable critical atmospheric measurements to form a complete picture of how, why, and when Venus evolved to be so different from Earth and Mars. The abundances and isotopic compositions of volatile elements (such as N, C, S, O, and the noble gases) in planetary atmospheres record volatile delivery during accretion, outgassing from planetary interiors, and atmospheric loss to space. Precise and accurate determinations of volatile atmospheric signatures are the key to understanding the origins and geodynamical evolution of Venus compared to the other terrestrial planets. Hypersonic sampling poses unique technical and scientific challenges. To ensure it is possible to relate the composition of the sampled gases to the free stream atmospheric composition, large-scale numerical simulations are employed to model the flow through the VATMOS-SR sampling system. In particular, an emphasis is placed on quantifying noble gas isotopic fractionation that occurs during the sample acquisition and transfer process to determine how measured isotopic ratios of noble gases in the sample compared to actual isotopic ratios in the Venusian atmosphere. The Direct Simulation Monte Carlo (DSMC) code SPARTA, an open-source software package developed by Sandia National Laboratories, is used in this work. SPARTA, based on Bird’s DSMC method, is a molecular-level gas-kinetic technique. As SPARTA is able to model hypervelocity reacting flows in strong chemical and thermal non-equilibrium, this software package is well suited to determine relevant flow properties for the VATMOS-SR mission concept and to numerically quantify the expected level of elemental and/or isotopic fractionation in the sample acquired by VATMOS-SR. This presentation will show results from 3D simulations correlating the noble gas isotopic fractionation in the gas acquired at hypervelocity speeds to its ambient atmosphere value. In particular, emphasis will be placed on Xenon isotopes of masses 128 and 130, as precise measurements of that ratio would yield comparison to Earth’s atmosphere. Additionally, sensitivity studies that quantify the uncertainties due to the freestream parameters, as well as the modeling parameters, will be performed.

direct simulation Monte Carlo↗

Comets, impacts, and atmospheres

Studies of element abundances and values of D/H in the atmospheres of the giant planets and Titan have emphasized the important role of icy planetesimals in the formation of these bodies. In these atmospheres, C/H and D/H increase as the relative masses of the 'cores' of the planets increase. N/H appears to deviate from this trend in an interesting way. In the inner solar system, the traditional approach of using carbonaceous chondrites as the source of planetary volatiles is in serious trouble because of the depletion of xenon and the unusual pattern of xenon isotopes found in the atmospheres of Earth and Mars, and because of the solar-type abundance ratios of argon, krypton and xenon and the large amounts of neon and argon on Venus. Recent studies of elemental abundances in comets, especially P/Halley, coupled with laboratory studies of the trapping of gas in ice formed at low temperatures by A. Bar-Nun et al. provide a consistent interpretation of all of these results. This interpretation emphasizes the fundamental importance of icy planetesimals (comets) and the randomness of early impacts in the formation of planetary systems. Cometary delivery by itself will not explain the noble gas abundances on the inner planets. There is good evidence for at least one additional source, which presumably consists of the rocky material making up the bulk of the planets. The existence of this rocky reservoir is manifested in the nucleogenic isotopes and in the neon which is found in all these atmospheres and is also present in the Earth's mantle. This neon may well be a relic of the planets' earliest, accretional atmospheres.

Owen, Tobias↗

Implications of Underground Nuclear Explosion Cavity Evolution for Radioxenon Isotopic Composition

Abstract Isotopic ratios of radioxenons sampled in the atmosphere or subsurface can be used to verify the occurrence of an underground nuclear explosion (UNE). Differences in the half-lives of radioactive xenon precursors and their decay-chain networks produce different time-dependent concentration profiles of xenon isotopes allowing isotopic ratios to be used for tracking UNE histories including estimating the time of detonation. In this study, we explore the potential effects of post-detonation cavity processes: precipitation of iodine precursors, gas seepage, and prompt venting on radioxenon isotopic evolution which influences UNE histories. Simplified analytical models and closed-form solutions yielding a potentially idealized radioactive decay/ingrowth chain in a closed and well-mixed system typically have limited application by not including the partitioning of the radionuclide inventory between a gas phase and rock melt created by the detonation and by ignoring gas transport from the cavity to host rock or ground surface. In reality, either subsurface transport or prompt release that is principally responsible for gas signatures violates the closed-system (or batch-mode) assumption. A closed-form solution representing time-dependent source-term activities is extended by considering the cavity partitioning process, slow seepage, and/or prompt release of gases from the cavity and applied to realistic systems.

Sun, Yunwei (ORCID:0000000194801439)↗

Lunar and Planetary Science XXXV: Isotopes in Meteorites

The session"Isotopes in Meteorites" consisted of the following presentations:The Common Property of Isotopic Anomalies in Meteorites; Revised Production Rates for 22Na and 54Mn in Meteorites Using Cross Sections Measured for Neutron-induced Reactions; Modeling of 14C and 10Be Production Rates in Meteorites and Lunar Samples; Investigating Xenon Isotopic Fractionation During Rayleigh-type Distillation; The Mean Life Squared Relationship for Abundances of Extinct Radioactivities; and Magnesium Isotopic Fractionation of Forsterite During Evaporation from Different Crystallographic Surfaces.

Source record↗

Gas diffusion through variably-water-saturated zeolitic tuff: Implications for transport following a subsurface nuclear event

Noble gas transport through geologic media has important applications in the characterization of underground nuclear explosions (UNEs). Without accurate transport models, it is nearly impossible to distinguish between xenon signatures originating from civilian nuclear facilities and UNEs. Understanding xenon transport time through the earth is a key parameter for interpreting measured xenon isotopic ratios. One of the most challenging aspects of modeling gas transport time is accounting for the effect of variable water saturation of geological media. In this study, we utilize bench-scale laboratory experiments to characterize the diffusion of krypton, xenon, and sulfur hexafluoride (SF6) through intact zeolitic tuff under different saturations. Here, we demonstrate that the water in rock cores with low partial saturation dramatically affects xenon transport time compared to that of krypton and SF6 by blocking sites in zeolitic tuff that preferentially adsorb xenon. This leads to breakthrough trends that are strongly influenced by the degree of the rock saturation. Xenon is especially susceptible to this phenomenon, a finding that is crucial to incorporate in subsurface gas transport models used for nuclear event identification. We also find that the breakthrough of SF6 diverges significantly from that of noble gases within our system. When developing field scale models, it is important to understand how the behavior of xenon deviates from chemical tracers used in the field, such as SF6 (Carrigan et al., 1996). These new insights demonstrate the critical need to consider the interplay between rock saturation and fission product sorption during transport modeling, and the importance of evaluating specific interactions between geomedia and gases of interest, which may differ from geomedia interactions with chemical tracers.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Fission gas trapped in Chornobyl fuel microparticles reveals details of reactor operations

The isotopic ratios of fission gas would provide important source information of a nuclear fuel sample found in the environment. However, it is believed that during a reactor accident like Chornobyl all fission gas is lost and that the radioactive particles found in the Chornobyl Exclusion Zone today are depleted in gases by the initial explosion and subsequent fire. We disprove this hypothesis by detection and analysis of trapped krypton and xenon in these particles. Our analysis of krypton and xenon isotopes by noble gas mass spectroscopy in combination with resonance ionization mass spectrometry establishes that important information about reactor operations like age, neutron flux and plutonium fission fraction can still be reconstructed from individual micrometer-sized particles even after decades of weathering in the environment.

Chornobyl↗

Energy resolution of the LZ detector for high-energy electronic recoils

The LUX-ZEPLIN (LZ) detector is a dual-phase liquid xenon time projection chamber (TPC) installed at the Sanford Underground Research Facility (Lead, South Dakota) at a depth of 1478 meters. Although the main objective of LZ is the direct detection of dark matter, its low background environment allows for the search of other rare processes, such as the neutrinoless double beta decay of xenon isotopes 134 Xe and 136 Xe with the respective Q-values of 826 keV and 2458 keV. The sensitivity of the detector to these decays is directly determined by the energy resolution, which, in turn, is degraded by non-uniformities in detector response. In this work, we present a novel method to correct, in the data, the non-uniformity of the light collected by an array of photosensors in a scintillation detector. This method is based on the knowledge of the light response functions of individual photosensors. With these techniques, we report, at a very early phase of the detector operations, a state-of-the-art energy resolution (σ/μ) of (0.67 ± 0.01)% at 2614 keV for the fiducial volume of 5.6 tonnes of liquid xenon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An NMR study of microvoids in polymers

An understanding of polymer defect structures, like microvoids in polymeric matrices, is crucial to their fabrication and application potential. In this project guest atoms are introduced into the microvoids in PMR-15 and NMR is used to determine microvoid sizes and locations. Xenon is a relatively inert probe that would normally be found naturally in polymer or in NMR probe materials. There are two NMR active xenon isotopes, Xe-129 and Xe-131. The Xe atom has a very high polarizability, which makes it sensitive to the intracrystalline environment of polymers. Interactions between the Xe atoms and the host matrix perturb the Xe electron cloud, deshielding the nuclei, and thereby expanding the range of the observed NMR chemical shifts. This chemical shift range which may be as large as 5000 ppm, permits subtle structural and chemical effects to be studied with high sensitivity. The Xe(129)-NMR line shape has been found to vary in response to changes in the pore symmetry of the framework hosts line Zeolites and Clathrasil compounds. Before exposure to Xe gas, the PMR-15 samples were dried in a vacuum oven at 150 C for 48 hours. The samples were then exposed to Xe gas at 30 psi for 72 hours and sealed in glass tubes with 1 atmosphere of xenon gas. Xenon gas at 1 atmosphere was used to tune up the spectrometer and to set up the appropriate NMR parameters. A single Xe-129 line at 83.003498 Mhz (with protons at 300 Mhz) was observed for the gas. With the xenon charged PMR-15 samples, a second broader line is observed 190 ppm downfield from the gas line (also observed). The width of the NMR line from the Xe-129 absorbed in the polymer is at least partially due to the distribution of microvoid sizes. From the chemical shift (relative to the gas line) and the line width, we estimate the average void sizes to be 2.74 +/- 0.20 angstroms. Since Xe-129 has such a large chemical shift range (approximately 5000 ppm), we expect the chemical shift anisotropy to contribute to the line width (delta upsilon = 2.5 kHz).

Toy, James↗

An NMR Study of Microvoids in Polymers

An understanding of polymer defect structures, like microvoids in polymeric matrices, is most crucial to their fabrication and application potential. In this project guest atoms are introduced into the microvoids in PMR-15 and NMR is used to determine microvoid sizes and locations. Xenon is a relatively inert probe that would normally not be found naturally in polymer or in NMR probe materials. There are two NMR active Xenon isotopes, Xe-129 and Xe-131. The Xe atom has a very high polarizability, which makes it sensitive to the intracrystalline environment of polymers. Interactions between the Xe atoms and the host matrix perturb and Xe electron cloud, deshielding the nuclei, and thereby expanding the range of the observed NMR chemical shifts. This chemical shift range which may be as large as 5000 ppm, permits subtle structural and chemical effects to be studied with high sensitivity. The Xe-129-NMR line shape has been found to vary in response to changes in the pore symmetry of the framework hosts in Zeolites and Clathrasil compounds. Before exposure to Xe gas, the PMR-15 samples were dried in a vacuum oven at 150 C for 48 hours. The samples were then exposed to Xe gas at 30 psi for 72 hours and sealed in glass tubes with 1 atmosphere of Xenon gas. Xenon gas at 1 atmosphere was used to tune up the spectrometer and to set up the appropriate NMR parameters. A series of spectra were obtained interspersed with applications of vacuum and heating to drive out the adsorbed Xe and determine the role of Xe-Xe interactions in the observed chemical shift.

Toy, James↗

A theoretical investigation of isotopic anomalies of xenon in terrestrial and extra-terrestrial samples

The abundance and isotopic composition of noble gases in meteorites is discussed in relation to the composition of the early solar system. Carbonaceous chondrites contain a unique Xenon-X, which is rich in heavy and light isotopes. Variations in the occurrence of type-X and type-Y (the normal component) noble gases are of such magnitude that neither the injection of material from a nearby supernova nor presence of presolar grains can account for the anomalies in meteorites. Therefore, it is suggested that the entire solar system may have condensed from the debris of a single local supernova.

Sabu, D. D.↗

Comparison of source-location algorithms for atmospheric samplers

Numerous algorithms have been developed to determine the source characteristics for an atmospheric release, e.g., (Bieringer et al., 2017). This study compares three models that have been applied to the data collected by the International Monitoring System operated by the Comprehensive Nuclear-Test-Ban Treaty Preparatory Commission to estimate source event parameters. Each model uses a different approach to estimate the parameters. A deterministic model uses a possible source region (PSR) approach (Ringbom et al., 2014) that is based on the correlation between predicted and measured sample values. An unnamed model developed at Pacific Northwest National Laboratory (herein called BAYEST) uses a Bayesian formulation (Eslinger et al., 2019; Eslinger et al., 2020; Eslinger and Schrom, 2016). The FREAR model uses a different Bayesian formulation (De Meutter and Hoffman, 2020; De Meutter et al., 2021; Pieter De Meutter, 2021). The performance of the three source-location models is evaluated with 100 synthetic release cases for the single xenon isotope, 133 Xe. The release cases resulted in detections in a fictitious network with 120 noble gas samplers. All three source-location models use the same sampling data. The two Bayesian models yield more accurate location estimates than the deterministic PSR model, with FREAR having slightly better location performance than BAYEST. Samplers with collection periods of 3, 6, 8, 12, and 24-h were used. Results from BAYEST show that location accuracy improves with each reduction in sample collection length. The BAYEST model is slightly better for estimating the start time of the release. The PSR model has about the same spread in start times as the FREAR model, but the PSR results have a better average start time. The Bayesian source-location algorithms give more accurate results than the PSR approach, and provide release magnitude estimates, while the base PSR model does not estimate the release magnitude. This investigation demonstrates that a reasonably dense sampling grid will sometimes yield poor location and time estimates regardless of the model. The poor estimates generally coincide with cases where there is a much larger distance between the release point and the first detecting sampler than the average sampler spacing.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Detecting 127 Xe in an atmospheric tracer experiment

The Xcounts algorithm for calculating air concentrations of radioactive xenon isotopes (Eslinger et al., 2023) has been extended to estimate 127 Xe in addition to 131m Xe, 133m Xe, 133 Xe, and 135 Xe. The algorithm was applied to 119 samples collected with a SAUNA Q B system (Ringbom et al., 2023) during a two-month atmospheric tracer release experiment. Finally, the algorithm identified two samples with 127 Xe present from a single 1.5 h release about 3.5 km upwind of the sampler and no false detections of 127 Xe were observed in the other samples.

127Xe calibration↗