Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D Design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

High‐Loaded Electrode Filaments for Additive Manufacturing of Structural Batteries

Abstract The unique capability of 3D printing to create geometric complex structures presents a promising avenue for producing 3D electrodes aimed at enhancing power and energy densities within constrained spaces, which is challenging to achieve through traditional slurry casting methods. However, despite advancements over the years, 3D‐printed batteries have faced limitations in terms of mechanical robustness to endure significant volume changes during cycling and restricted electrochemical performance due to the lack of adequate electrode feedstock development or post‐processing treatments. Herein, a high‐loaded electrode filament with ≈65 wt.% fillers, enabling the fabrication of structural electrodes with improved electrochemical performance and superior mechanical properties, is developed. Through a combination of 3D printing and post‐processing techniques, interdigitated structures with high areal‐loading density, resulting in a full cell with an enhanced areal capacity of ≈12.28 mAh cm −2 at ≈0.92 mA cm −2 is fabricated. Moreover, the structural batteries, treated through the carbonizing process, are integrated by the carbon coating generated during carbonization, exhibiting remarkable compressive properties (with a modulus of 18.5 MPa and a strength of 1.09 MPa). Overall, the findings demonstrate the promising potential of 3D printed batteries for practical applications, while showcasing the scalability and design flexibility offered by 3D printing technology.

Chemistry↗

Elevated‐Temperature 3D Printing of Hybrid Solid‐State Electrolyte for Li‐Ion Batteries

Abstract While 3D printing of rechargeable batteries has received immense interest in advancing the next generation of 3D energy storage devices, challenges with the 3D printing of electrolytes still remain. Additional processing steps such as solvent evaporation were required for earlier studies of electrolyte fabrication, which hindered the simultaneous production of electrode and electrolyte in an all‐3D‐printed battery. Here, a novel method is demonstrated to fabricate hybrid solid‐state electrolytes using an elevated‐temperature direct ink writing technique without any additional processing steps. The hybrid solid‐state electrolyte consists of solid poly(vinylidene fluoride‐hexafluoropropylene) matrices and a Li + ‐conducting ionic‐liquid electrolyte. The ink is modified by adding nanosized ceramic fillers to achieve the desired rheological properties. The ionic conductivity of the inks is 0.78 × 10 −3 S cm −1 . Interestingly, a continuous, thin, and dense layer is discovered to form between the porous electrolyte layer and the electrode, which effectively reduces the interfacial resistance of the solid‐state battery. Compared to the traditional methods of solid‐state battery assembly, the directly printed electrolyte helps to achieve higher capacities and a better rate performance. The direct fabrication of electrolyte from printable inks at an elevated temperature will shed new light on the design of all‐3D‐printed batteries for next‐generation electronic devices.

Cheng, Meng↗

Investigation of chemical stabilities and contact angle of 3D printed polymers with CO 2 capture solvents to enhance absorber performance

Increasing absorption rate in aqueous amine CCS systems is one avenue to decrease capital cost by reducing the overall size of the absorber column. One potential route is by replacing conventional steel packing with custom designed packing made from 3D printed polymers. 3D printing offers endless flexibility in packing designs to better enhance liquid/gas contact, increase CO 2 mass transfer and create compact absorber columns. Additionally, before exploring novel packing designs, it is necessary to identify polymer materials that can be 3D printed while also showing long-term physical and surface property stability upon exposure to corrosive amine solutions. Four polymers that are commonly used for 3D printing were evaluated using CO 2 -loaded amine solution at temperatures typically observed in the absorber column. Three polymers, high-density polystyrene (HDPS), acrylonitrile butadiene styrene (ABS) and nylon were found to be physically stable after 5000 hr of amine exposure at temperatures up to 60 °C. The contact angle (wetting) of water and CO 2 -loaded aqueous amine solution on the polymer surfaces were also stable after exposure to the CO2-loaded amine solution.

36 MATERIALS SCIENCE↗

Highly Symmetric, Self-Assembling 3D DNA Crystals with Cubic and Trigonal Lattices

The rational design of nanoscopic DNA tiles has yielded highly ordered crystalline matter in 2D and 3D. The most well-studied 3D tile is the DNA tensegrity triangle, which is known to self-assemble into macroscopic crystals. However, contemporary rational design parameters for 3D DNA crystals nearly universally invoke integer numbers of DNA helical turns and Watson–Crick (WC) base pairs. Here, in this study, 24-bp edges are substituted into a previously 21-bp (two helical turns of DNA) tensegrity triangle motif to explore whether such unconventional motif can self-assemble into 3D crystals. The use of noncanonical base pairs in the sticky ends results in a cubic arrangement of tensegrity triangles with exceedingly high symmetry, assembling a lattice from winding helical axes and diamond-like tessellation patterns. Reverting this motif to sticky ends with Watson–Crick pairs results in a trigonal hexagonal arrangement, replicating this diamond arrangement in a hexagonal context. These results showcase that the authors can generate unexpected, highly complex, pathways for materials design by testing modifications to 3D tiles without prior knowledge of the ensuing symmetry. This study expands the rational design toolbox for DNA nanotechnology; and it further illustrates the existence of yet-unexplored arrangements of crystalline soft matter.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

WE-H-206-00: Advances in Preclinical Imaging

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

WE-H-206-02: Recent Advances in Multi-Modality Molecular Imaging of Small Animals

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

WE-H-206-03: Promises and Challenges of Benchtop X-Ray Fluorescence CT (XFCT) for Quantitative in Vivo Imaging

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

WE-H-206-01: Photoacoustic Tomography: Multiscale Imaging From Organelles to Patients by Ultrasonically Beating the Optical Diffusion Limit

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

Impact of Timing in the Design Process on Students’ Application of Design for Additive Manufacturing Heuristics

The goal of this work is to study the way student designers use design for additive manufacturing (DfAM) rules or heuristics. It can be challenging for novice designers to create successful designs for additive manufacturing (AM), due to its recent surge in popularity and lack of formal education or training. A study was carried out to investigate the way novices apply DfAM heuristics when they receive them at different points in the design process. A design problem was presented to students, and three different groups of student participants were given a lecture on DfAM heuristics at three different points in the design process: before the initial design, between the initial design and redesign, and after the redesign. The novelty and quality of each of the resulting designs were evaluated. Results indicate that although the DfAM heuristics lecture had no impact on the overall quality of the designs generated, participants who were given the heuristics lecture after the initial design session produced designs that were better-suited for 3D printing in the second phase of the design activity. However, receiving this additional information appears to prevent students from creatively iterating upon their initial designs, as participants who received heuristic information between the design sessions experienced a decrease in novelty between the two sessions. Additionally, receiving the heuristics lecture increased all students’ perceptions of their ability to perform DfAM-related tasks. Furthermore, these results validate the practicality of design heuristics in lecture form as AM training tools while also emphasizing the importance of iteration in the design process.

computer-aided design↗

A Nickel-Decorated Carbon Flower/Sulfur Cathode for Lean-Electrolyte Lithium–Sulfur Batteries

Lithium–sulfur (Li–S) batteries involve a reversible conversion reaction between sulfur and lithium sulfide (Li 2 S) via a series of soluble lithium polysulfide intermediates (LiPSs), enabling a high theoretical specific capacity of 1675 mAh g –1 . However, this process exhibits large polarization and low sulfur utilization and suffers critical capacity fade. The primary approach to tackle the problem has so far been to infiltrate sulfur into nanostructured carbon. Furthermore, most studies using porous carbon as host materials have tested with high electrolyte to sulfur ratios (E/S) (generally > 15 µL mg –1 ) that compromise the cell-level energy density. Here, a flower-shaped porous carbon structure with nickel nanoparticles that can address the problems discussed above is designed. First, the 3D flower-shaped carbon structure enables short ionic transport lengths. Second, the small pore diameters <10 nm and high specific surface areas > 3300 m 2 g –1 with sufficient pore volume are ideal for charging performance for low E/S ratios. Finally, Ni nanoparticles are employed onto the flower-shaped network to improve the reaction kinetics. Collectively, it is successfully demonstrated that the batteries with a high mass loading of 5 mg cm –2 and a 5 µL mg –1 E/S ratio can retain cycle retention of 70% after 150 cycles.

25 ENERGY STORAGE↗

DIY XES-development of an inexpensive, versatile, and easy to fabricate XES analyzer and sample delivery system

The application of X-ray emission spectroscopy (XES) has grown substantially with the development of X-ray free-electron lasers, third and fourth generation synchrotron sources, and high-power benchtop sources. By providing the high X-ray flux required for XES, these sources broaden the availability and application of this method of probing electronic structure. As the number of sources increase, so does the demand for X-ray emission detection and sample delivery systems that are cost effective and customizable. In this work, we present a detailed fabrication protocol for von Hamos X-ray optics and give details for a 3D-printed spectrometer design. Additionally, we outline an automated, externally triggered liquid sample delivery system that can be used to repeatedly deliver nanoliter droplets onto a plastic substrate for measurement. These systems are both low cost, efficient, and easy to recreate or modify depending on the application. A low cost multiple X-ray analyzer system enables measurement of dilute samples, whereas the sample delivery limits sample loss and reproducibly replaces spent sample with fresh sample in the same position. While both systems can be used in a wide range of applications, the design addresses several challenges associated specifically with time-resolved XES (TRXES). As an example application, we show results from TRXES measurements of photosystem II, a dilute, photoactive protein.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Learning high-dimensional parametric maps via reduced basis adaptive residual networks

We propose a scalable framework for the learning of high-dimensional parametric maps via adaptively constructed residual network (ResNet) maps between reduced bases of the inputs and outputs. When just few training data are available, it is beneficial to have a compact parametrization in order to ameliorate the ill-posedness of the neural network training problem. By linearly restricting high-dimensional maps to informed reduced bases of the inputs, one can compress high-dimensional maps in a constructive way that can be used to detect appropriate basis ranks, equipped with rigorous error estimates. A scalable neural network learning framework is thus to learn the nonlinear compressed reduced basis mapping. Unlike the reduced basis construction, however, neural network constructions are not guaranteed to reduce errors by adding representation power, making it difficult to achieve good practical performance. Inspired by recent approximation theory that connects ResNets to sequential minimizing flows, we present an adaptive ResNet construction algorithm. This algorithm allows for depth-wise enrichment of the neural network approximation, in a manner that can achieve good practical performance by first training a shallow network and then adapting. We prove universal approximation of the associated neural network class for $L^2_v$ functions on compact sets. Our overall framework allows for constructive means to detect appropriate breadth and depth, and related compact parametrizations of neural networks, significantly reducing the need for architectural hyperparameter tuning. Numerical experiments for parametric PDE problems and a 3D CFD wing design optimization parametric map demonstrate that the proposed methodology can achieve remarkably high accuracy for limited training data, and outperformed other neural network strategies we compared against.

42 ENGINEERING↗

Shape memory behavior and recovery force of 4D printed textile functional composites

Four-dimensional (4D) printing of multi-directionally reinforced preforms has tremendous potential for the development of next generation functional composites by using the capabilities of 3D printing technology, 3D textile preform design, and polymer shape memory behavior. This paper demonstrates the shape memory behavior and recovery force of 4D printed circular braided tube preforms and their silicone elastomer matrix composites. The preforms were printed by fused deposition modeling using the shape memory polymer (SMP), polylactic acid (PLA). The effects of braiding angle, tube wall thickness, and shape recovery temperature on the shape memory behavior of 4D printed tube preforms and their silicone elastomer matrix composites have been characterized. Measurements of shape recovery forces of the preform and composite were conducted using dynamic mechanical analysis (DMA). The braided microstructural parameters and shape recovery temperature have a significant effect on the preform shape memory behavior. The introduction of the silicone elastomer matrix greatly enhances the shape recovery force, shape recovery ratio, as well as radial compressive failure load of the 4D printed preform/silicone elastomer matrix composite. Finally, building on these results, a potential application for 4D printed textile functional composites is presented.

42 ENGINEERING↗

A directional electrode separator improves anodic biofilm current density in a well-mixed single-chamber bioelectrochemical system

In this study, a directional electrode separator (DES) was designed and incorporated into a single-chamber bioelectrochemical system (BES) to reduce migration and reoxidation of hydrogen. This issue arises when H 2 , generated at the cathode, travels to the anode where anodic biofilms use H 2 . To test the feasibility of our design, a 3D-printed BES reactor equipped with a DES was inoculated with anaerobic digestor granules and operated under fed-batch conditions using fermented corn stover effluent. The DES equipped reactor achieved significantly higher current densities (~53 A/m²) compared to a conventional single-chamber BES without a separator (~16 A/m²), showing a 3.3 times improvement. Further, control abiotic electrochemical experiments revealed that the DES exhibited significantly higher proton conductivity (456±127 µS/mm) compared to a proton exchange membrane (67±21 µS/mm) with a statistical significance of P=0.03. The DES also effectively reduced H 2 migration to the anode by 21-fold relative to the control. Overall, incorporating a DES in a single-chamber BES enhanced anodic current density by reducing H 2 migration to the anode.

3D printed BES↗

Establishing a process-structure-property-performance framework for SLS additive manufacturing through integrated multiscale modeling

This study presents a comprehensive suite of high-fidelity computational models that integrate multiscale and multiphysics simulations to capture the full Selective Laser Sintering (SLS) additive manufacturing process—from initial melting and solidification to mechanical response under external loads. Process simulations are linked with mechanical analysis through Representative Volume Elements (RVEs), establishing a process-structure–property-performance framework. The interaction between laser light and polyamide 12 (PA12) powder is modeled, accounting for laser characteristics and the optical, thermal, and geometrical properties of the powder. The heat source is incorporated into a heat transfer model, coupled with crystallization kinetics and densification models to predict material density and crystallinity. The porosity distribution from the densification model and crystallinity interpolated from experimental data are used to construct the RVEs. A multi-mechanism constitutive model is then calibrated using mechanical tests to predict the stress–strain response. Simulation results show good agreement with experimental data in terms of porosity, crystallinity, and mechanical performance when sufficient laser power (62 W or higher) is used. This research supports the inverse design of 3D-printed structures by introducing a high-fidelity framework that combines multiscale and multiphysics modeling with experimental calibration for predictive and performance-driven additive manufacturing.

SLS↗

Elucidation of Active Oxygen Sites upon Delithiation of Li 3 IrO 4

Transformational increases in the storage capacity of battery cathodes could be achieved by tapping into the redox activity at oxide ligands in addition to conventional transition metal couples. However, the key signatures that govern such lattice oxygen redox (LOR) have not been ascertained. Li 3 IrO 4 has the largest reversible LOR, rendering it a unique model system. Here, X-ray spectroscopy and computational simulations reveal that LOR in Li 3 IrO 4 is selectively compensated via O sites with three lone pairs, which are activated by Li/Ir disorder. The two-electron LOR can be reversed to regenerate the initial state without unlocking competing bulk reactions observed in many other compounds. We uncover an intricate interplay between stoichiometry, O coordination, and nonbonding states in LOR and pinpoint spectroscopic signatures. This interplay is indispensable for designing materials with 3d metals that fulfill the promise of LOR to overcome the bottlenecks of current cathodes for future implementation in practical batteries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Large Scale Laser Two-Photon Polymerization Structuring for Fabrication of Artificial Polymeric Scaffolds for Regenerative Medicine

We present a femtosecond Laser Two-Photon Polymerization (LTPP) system of large scale three-dimensional structuring for applications in tissue engineering. The direct laser writing system enables fabrication of artificial polymeric scaffolds over a large area (up to cm in lateral size) with sub-micrometer resolution which could find practical applications in biomedicine and surgery. Yb:KGW femtosecond laser oscillator (Pharos, Light Conversion. Co. Ltd.) is used as an irradiation source (75 fs, 515 nm (frequency doubled), 80 MHz). The sample is mounted on wide range linear motor driven stages having 10 nm sample positioning resolution (XY--ALS130-100, Z--ALS130-50, Aerotech, Inc.). These stages guarantee an overall travelling range of 100 mm into X and Y directions and 50 mm in Z direction and support the linear scanning speed up to 300 mm/s. By moving the sample three-dimensionally the position of laser focus in the photopolymer is changed and one is able to write complex 3D (three-dimensional) structures. An illumination system and CMOS camera enables online process monitoring. Control of all equipment is automated via custom made computer software ''3D-Poli'' specially designed for LTPP applications. Structures can be imported from computer aided design STereoLihography (stl) files or programmed directly. It can be used for rapid LTPP structuring in various photopolymers (SZ2080, AKRE19, PEG-DA-258) which are known to be suitable for bio-applications. Microstructured scaffolds can be produced on different substrates like glass, plastic and metal. In this paper, we present microfabricated polymeric scaffolds over a large area and growing of adult rabbit myogenic stem cells on them. Obtained results show the polymeric scaffolds to be applicable for cell growth practice. It exhibit potential to use it for artificial pericardium in the experimental model in the future.

36 MATERIALS SCIENCE↗