Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D Scanning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

SU-F-BRB-05: Collision Avoidance Mapping Using Consumer 3D Camera

Purpose: To develop a fast and economical method of scanning a patient’s full body contour for use in collision avoidance mapping without the use of ionizing radiation. Methods: Two consumer level 3D cameras used in electronic gaming were placed in a CT simulator room to scan a phantom patient set up in a high collision probability position. A registration pattern and computer vision algorithms were used to transform the scan into the appropriate coordinate systems. The cameras were then used to scan the surface of a gantry in the treatment vault. Each scan was converted into a polygon mesh for collision testing in a general purpose polygon interference algorithm. All clinically relevant transforms were applied to the gantry and patient support to create a map of all possible collisions. The map was then tested for accuracy by physically testing the collisions with the phantom in the vault. Results: The scanning fidelity of both the gantry and patient was sufficient to produce a collision prediction accuracy of 97.1% with 64620 geometry states tested in 11.5 s. The total scanning time including computation, transformation, and generation was 22.3 seconds. Conclusion: Our results demonstrate an economical system to generate collision avoidance maps. Future work includes testing the speed of the framework in real-time collision avoidance scenarios. Research partially supported by a grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-F-BRF-14: Increasing the Accuracy of Dose Calculation On Cone-Beam Imaging Using Deformable Image Registration in the Case of Prostate Translation

Purpose: Artifacts can reduce the quality of dose re-calculations on CBCT scans during a treatment. The aim of this project is to correct the CBCT images in order to allow for more accurate and exact dose calculations in the case of a translation of the tumor in prostate cancer. Methods: Our approach is to develop strategies based on deformable image registration algorithms using the elastix software (Klein et al., 2010) to register the treatment planning CT on a daily CBCT scan taken during treatment. Sets of images are provided by a 3D deformable phantom and comprise two CT and two CBCT scans: one of both with the reference anatomy and the others with known deformations (i.e. translations of the prostate). The reference CT is registered onto the deformed CBCT and the deformed CT serves as the control for dose calculation accuracy. The planned treatment used for the evaluation of dose calculation is a 2-Gy fraction prescribed at the location of the reference prostate and assigned to 7 rectangular fields. Results: For a realistic 0.5-cm translation of the prostate, the relative dose discrepancy between the CBCT and the CT control scan at the prostate's centroid is 8.9 ± 0.8 % while dose discrepancy between the registered CT and the control scan lessens to −2.4 ± 0.8 %. For a 2-cm translation, clinical indices like the V90 and the D100 are more accurate by 0.7 ± 0.3 % and 8.0 ± 0.5 cGy respectively when using registered CT than when using CBCT for dose calculation. Conclusion: The results show that this strategy gives doses in agreement within a few percents with those from calculations on actual CT scans. In the future, various deformations of the phantom anatomy will allow a thorough characterization of the registration strategies needed for more complex anatomies.

60 APPLIED LIFE SCIENCES↗

TU-F-CAMPUS-I-02: Contrast Enhanced Cone Beam CT Imaging with Dual- Gantry Image Acquisition and Constrained Iterative Reconstruction-a Simulation Study for Liver Imaging Application

Purpose: Contrast time-density curves may help differentiate malignant tumors from normal tissues or benign tumors. Repetitive scans using conventional CT or cone beam CT techniques, which Result in unacceptably high dose, may not achieve the desired temporal resolution. In this study we describe and demonstrate a 4D imaging technique for imaging and quantifying contrast flows requiring only one or two 360° scans. Methods: A dual-gantry system is used to simultaneously acquire two projection images at orthogonal orientations. Following the scan, each or both of the two 360° projection sets are used to reconstruct an average contrast enhanced image set which is then segmented to form a 3D contrast map. Alternatively, a pre-injection scan may be made and used to reconstruct a pre-injection image set which is subtracted from the post-injection image set to form the 3D contrast map. Each of the two 360° projection sets is divided into 12 subsets, thus creating 12 pairs of 30° limited angle projection sets, each corresponding to a time spanning over 1/12 of the scanning time. Each pair of the projection sets are reconstructed as a time specific 3D image set with the maximum likelihood estimation iterative algorithm using the contrast map as the constraint. As a demonstration, a 4D abdominal phantom was constructed from clinical CT images with blood flow through the normal tissue and a tumor modeled and imaging process simulated. Results: We have successfully generated a 4D image phantom, and calculated the projection images. The time density curves derived from the reconstructed image set matched well with the flow model used to generate the phantom. Conclusion: Dual-gantry image acquisition and constrained iterative reconstruction algorithm may help to obtain time-density curves of contrast agents in blood flows, which may help differentiate malignant tumors from normal tissues or benign tumors.

60 APPLIED LIFE SCIENCES↗

Samarium electrodeposited acetate and oxide thin films on stainless steel substrate characterized by XPS

Characterization of a samarium thin film deposited on a stainless steel substrate using molecular electrodeposition was carried out using a Thermo Scientific K-Alpha X-ray photoelectron spectrometer. We studied two types of samarium electrodeposition samples, one as-deposited and one heated to 700 °C in an air flow. Survey scans include peaks coming from the stainless steel substrate, such as Fe and Cr. An X-ray photoelectron spectroscopy (XPS) survey spectrum, Sm 3d, C 1s, and O 1s narrow scans are shown. It was determined that the heating process decomposed the deposited Sm acetate to Sm 2 O 3 using XPS.

36 MATERIALS SCIENCE↗

Southern Great Plains (SGP) Three-Dimensional Observations of Fair-Weather Cumuli Field Campaign Report

The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility Southern Great Plains (SGP) Three-Dimensional (3D) Observations of Fair-Weather Cumuli (SGP3DOBS) experiment employed scanning Doppler lidar and the recently installed stereo camera ring to conduct a one-month intensive operational period (IOP) of fair-weather cumuli in a 3D domain at the ARM SGP Central Facility (CF). The SGP3DOBS is part of the Climate Model Development and Validation (CMDV) “Coupling Mechanistically the Convective Motions and Cloud Macrophysics in a Climate Model” (CM4) project and provides advanced observational analyses for improving physical understanding of shallow cumulus and supporting model parameterization evaluation. For the CM4 project, cloud macroscale and dynamical properties are determined using vertically pointing active remote-sensing measurements (e.g., lidar and radar), which provide a 2D view of fair-weather cumuli (FWC). It is critical to evaluate how well the 2D observations represent 3D cloud fields. The objectives of SGP3DOBS include: 1) evaluate the 3D gridded cloud field from stereo photogrammetry with scanning Doppler lidar measurements; 2) retrieve sub-cloud-layer turbulence (vertical velocity and mass flux) in a 3D domain; 3) estimate shallow cumulus lateral entrainment rate and its relation to environment conditions. The SGP3DOBS IOP was held at the SGP Central Facility from August 31 to September 30, 2017, as the fair-weather nonprecipitating shallow cumuli are prevalent during summertime over land (Lamer and Kollias, 2015). A weather forecast team conducted a short-range forecast of weather conditions in the early morning each day to determine whether it was favorable for FWC. For each IOP day, the Doppler lidar at the SGP Central Facility ran under the range height indicator (RHI) scanning mode in the cross-wind direction. Occasionally, plan position indicator (PPI) scanning mode was run for updated wind directions. During each RHI scanning, the Doppler lidar run continuously between 30- and 150-degree elevation angles. The scanning rate was approximately 10 degree/s, corresponding to a transverse resolution of 111 m at 2 km of a typical FWC height. The newly established three pairs of stereo cameras ran concurrently during the IOP.

Southern Great Plains, Doppler lidar, fair-weather↗

Few-view image reconstruction

A CT image reconstruction system is provided that provides a solution to a few-view problem by generating a 3D image from measurements and a forward projection matrix for a CT scan of an object that tends to minimize streaks and other artifacts. The system initially receives measurements and a forward projection matrix for the CT scan. The system during an initial stage generates an initial 3D image based on various constraints so that (1) the reconstruction of the initial 3D image can be perform quickly and (2) the difference between the measurements and the forward projection of the initial 3D image has significantly lower contrast and high frequency content as compared the measurements themselves. The system then during a final stage applies an iterative algorithm to reconstruct the 3D image with the 3D image initialized to the initial 3D image at the beginning of the iterative algorithm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-571: Objective Assessment of 3D Dosimetry for Flattened and Flattened Filter Free Stereotactic Rotational Delivery Using 729-Array Detector with Octavius 4D Phantom

Purpose: The purpose of this study was to assess the potential of 3D dosimetry for flattened and flattened filter free stereotactic rotational delivery in high definition MLC using 729-detector array with Octavius 4D phantom Methods: Twenty rapid arc plans were assessed for this study. For each patient two plans for 6X and 6FFF photon beams were generated with same prescription and critical organ constraints in Eclipse TPS version 13.0 using high definition MLC. Verification plans were generated in scanned Octavius 4D phantom in TPS. 3D dose measurements were collected from 729-ion chamber detector array in Octavius 4D phantom using verisoft software v 6.0. TPS calculated dose was compared with measured 3D dose in verisoft using the following gamma analysis parameters such as 3D volumetric, 3D planar and 2D global gamma in transverse, sagittal and coronal planes for 3mm/3% and 2mm/2% distance to agreement criteria.Passing rate and arithmetic mean of global gamma were analysed for 2D and 3D global gamma in all planes. Results: The average number of dose points passing rate for 2D global gamma with 3mm/3% criteria in transverse, sagittal and coronal planes was 99.06%±2.89%, 98.8%±0.88% and 99.06%±91%, respectively. For 2mm/2% criteria 97.86%±2.26%, 94.49± 2.64% and 94.34%±2.9% was observed. In 3D planar global gamma with 3mm/3% was 99.53%±0.49%, 98.93%±1.03% and 99.29%±1.29%, for 2mm 2% criteria was 97.50%±2.24%, 94.5%±2.5% and 95.38%±4.5%. The maximum arithmetic mean gamma deviation of 0.505%±0.13% was observed in coronal plane for 2D global gamma with 2mm/2% criteria. The 3D volumetric gamma passing rate was observed as 99.61%±0.433% for 3mm /3% and 95.91%±2.51% for 2mm/2%. Conclusion: The objective assessment of 3D dosimetry have demonstrated that the rotational delivery accuracy for flattened and flattened filter free stereotactic plans can be verified by using Octavius system comprising with 729 ion chamber array and Octavius 4D phantom.

60 APPLIED LIFE SCIENCES↗

Accelerated deep self-supervised ptycho-laminography for three-dimensional nanoscale imaging of integrated circuits

Three-dimensional inspection of nanostructures such as integrated circuits is important for security and reliability assurance. Two scanning operations are required: ptychographic to recover the complex transmissivity of the specimen, and rotation of the specimen to acquire multiple projections covering the 3D spatial frequency domain. Two types of rotational scanning are possible: tomographic and laminographic. For flat, extended samples, for which the full 180° coverage is not possible, the latter is preferable because it provides better coverage of the 3D spatial frequency domain compared to limited-angle tomography. It is also because the amount of attenuation through the sample is approximately the same for all projections. However, both techniques are time consuming because of extensive acquisition and computation time. Here, we demonstrate the acceleration of ptycho-laminographic reconstruction of integrated circuits with 16 times fewer angular samples and 4.67 times faster computation by using a physics-regularized deep self-supervised learning architecture. We check the fidelity of our reconstruction against a densely sampled reconstruction that uses full scanning and no learning. As already reported elsewhere [ Opt. Express 28 , 12872 ( 2020 ) OPEXFF 1094-4087 10.1364/OE.379200 ], we observe improvement of reconstruction quality even over the densely sampled reconstruction, due to the ability of the self-supervised learning kernel to fill the missing cone.

47 OTHER INSTRUMENTATION↗

Feasibility study of a high-spatial resolution x-ray computed tomography using sub-pixel shift method

A high-spatial resolution X-ray computed tomography (CT) adopting a sub-pixel shift method has been developed. By calculating sectional images, using plural CT datasets obtained by scanning the X-ray imager, the spatial resolution can be reduced relative to the sub-pixel size of an X-ray imager. Feasibility observations of a biomedical sample were performed using 12-keV monochromatic synchrotron radiation and a photon-counting X-ray imager 174-μm pixels in size. Four CT measurements were performed to obtain datasets at different positions of the X-ray imager. Fine sectional images were obtained successfully, and the spatial resolution was estimated as 80-μm, which corresponds to just under half the pixel size of the imager. In addition, a fine 3D image was also obtained by scanning the imager two-dimensionally.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

XEDS STEM Tomography For 3D Chemical Characterization Of Nanoscale Particles

We present a tomography technique which couples scanning transmission electron microscopy (STEM) and X-ray energy dispersive spectrometry (XEDS) to resolve 3D distribution of elements in nanoscale materials. STEM imaging when combined with a symmetrically arranged XEDS detector design around the specimen overcomes many of the obstacles in 3D spectroscopic tomography of nanoscale materials and successfully elucidate the 3D chemical information in a large field of view of the TEM sample. We employed this technique to investigate 3D distribution of Nickel (Ni), Manganese (Mn) and Oxygen (O) in Li(NiMn)O2 battery cathode material. For this purpose, 2D elemental maps were acquired for a range of tilt angles and reconstructed to obtain 3D elemental distribution in an isolated Li(NiMnO2) nanoparticle. The results highlight the strength of this technique in 3D chemical analysis of nanoscale materials by successfully resolving Ni, Mn and O elemental distributions in 3D and discovering the new phenomenon of Ni surface segregation in this material. Furthermore, the comparison of simultaneously acquired HAADF STEM and XEDS STEM tomography results show that XEDS STEM tomography provides additional 3D chemical information of the material especially when there is low atomic number (Z) contrast in the material of interest.

Environmental Molecular Sciences Laboratory↗

Computational multiphysics modeling of radioactive aerosol deposition in diverse human respiratory tract geometries

The evaluation of aerosol exposure relies on generic mathematical models that assume uniform particle deposition profiles over the human respiratory tract and do not account for subject-specific characteristics. Here we introduce a hybrid-automated computational workflow that generates personalized particle deposition profiles in 3D reconstructed human airways from computed tomography scans using Computational Fluid and Particle Dynamics simulations. This is the first large-scale study to consider realistic airways variability, where 380 lower and 40 upper human respiratory tract 3D geometries are reconstructed and parameterized. The data is clustered into nine groups using random forest regression. Computational fluid and particle dynamics simulations are conducted on these representative geometries using a realistic heavy-breathing respiratory cycle and radioactive iodine-131 as a source term. Monte Carlo radiation transport simulations are performed to obtain detailed energy deposition maps. Our findings emphasize the importance of personalized studies, as minor respiratory tract variations notably influence deposition patterns rather than global parameters of the lower airways, observing more than 30% variance in the mass deposition fraction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Creation of a prototype biomimetic fish to better understand impact trauma caused by hydropower turbine blade strikes

Biomimetic model organisms could be useful surrogates for live animals in many applications if the models have sufficient biofidelity. One such application is for use in field and laboratory tests of fish mortality associated with passage through hydropower turbines. Laboratory trials suggest that blade strikes are especially injurious and often causes mortality when fish are struck by thinner blades moving at higher velocities. Dose-response relationships have been created from these data, but the exact relationship between fish mortality and the actual forces enacted on fish during simulated blade strike testing remains unknown. Here, we describe the methods used to create a prototype biomimetic model fish composed of ballistic gelatin and covered with a surrogate skin to better approximate the biomechanical properties of a fish body. Frozen fish were scanned with high-fidelity laser scanners, and a 3D-printed, reusable mold was created from which to cast our gelatin model. Computed tomography scan data, imaged directly or taken from online data repositories, were also successfully used to create CAD models for use in additive manufacturing of molds. One 3-axis accelerometer was embedded into the gelatin to compare accelerometer data to dose-response data from previous laboratory research on live fish. The resulting model ( i.e. , Gelfish) had a statistically indistinguishable tissue durometer to that of real fish tissue and preliminary blade strike impact testing suggested its overall flexibility was similar to that of live fish. Gelfish was designed with biofidelity as its guiding principle and our results suggest initial experimentation was successful. Future research will include replication of initial Gelfish test results, quantitative measurement of model flexibility relative to real fish, and inclusion of surrogate skeletal structures to enhance biofidelity. Use of more sophisticated sensors would also better quantify the physical forces of blade strike impact and help determine how said forces correlate with rates of mortality observed during tests on live fish.

36 MATERIALS SCIENCE↗

Three-dimensional scanning transmission electron microscopy of biological specimens

A three-dimensional (3D) reconstruction of the cytoskeleton and a clathrin-coated pit in mammalian cells has been achieved from a focal-series of images recorded in an aberration-corrected scanning transmission electron microscope (STEM). The specimen was a metallic replica of the biological structure comprising Pt nanoparticles 2 - 3 nm in diameter, with a high stability under electron beam radiation. The 3D dataset was processed by an automated deconvolution procedure. The lateral resolution was 1.1 nm, set by pixel size. Particles differing by only 10 nm in vertical position were identified as separate objects with greater than 20% dip in contrast between them. We refer to this value as the axial resolution of the deconvolution or reconstruction, the ability to recognize two objects, which were unresolved in the original data set. The precision of the height determination was 0.2 nm. The resolution of the reconstruction is comparable to that achieved by tilt-series transmission electron microscopy (TEM). However, the focal-series method does not require mechanical tilting and is therefore much faster. 3D STEM images were also recorded of the Golgi ribbon in conventional thin sections containing 3T3 cells with a comparable axial resolution in the deconvolved data set.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In Situ Synthesis of 3D Interconnected Graphene-Reinforced Copper Composites

Graphene shows great potential in composite applications, but the performance of traditional graphene-metal composites is poorer than desired due to the uneven dispersion of graphene in the matrix. This study provides an effective method to grow high-quality graphene on the surface of 3D porous copper using a combination of chemical vapor deposition and spark plasma sintering to obtain a dense 3D-interconnected graphene/Cu composite. Transmission electron microscopy and scanning electron microscopy showed that graphene-coated copper and Raman analysis showed high-quality graphene. The tensile strength of the 3D graphene/Cu composite was 425 MPa, which is ~ 25% higher than that of pure Cu, and the coefficient of friction (0.33) is about 45% lower than that of pure Cu (0.58). The formation of high-quality 3D graphene interconnects in the Cu matrix results in a higher mechanical strength, better friction properties and superior electrical and thermal conductivity of the composite compared to those of pure Cu.

36 MATERIALS SCIENCE↗

Statistical 3D morphology characterization of vaterite microspheres produced by engineered Escherichia coli

Hollow vaterite microspheres are important materials for biomedical applications such as drug delivery and regenerative medicine owing to their biocompatibility, high specific surface area, and ability to encapsulate a large number of bioactive molecules and compounds. We demonstrated that hollow vaterite microspheres are produced by an Escherichia coli strain engineered with a urease gene cluster from the ureolytic bacteria Sporosarcina pasteurii in the presence of bovine serum albumin. We characterized the 3D nanoscale morphology of five biogenic hollow vaterite microspheres using 3D high-angle annular dark field scanning transmission electron microscopy (HAADF-STEM) tomography. Using automated high-throughput HAADF-STEM imaging across several sample tilt orientations, we show that the microspheres evolved from a smaller more ellipsoidal shape to a larger more spherical shape while the internal hollow core increased in size and remained relatively spherical, indicating that the microspheres produced by this engineered strain likely do not contain the bacteria. The statistical 3D morphology information demonstrates the potential for using biogenic calcium carbonate mineralization to produce hollow vaterite microspheres with controlled morphologies.

3D morphology↗

Field evaluation of remote wind sensing technologies: Shore-based and buoy mounted LIDAR systems

In developing a national energy strategy, the United States has a number of objectives, including increasing economic growth, improving environmental quality, and enhancing national energy security. Wind power contributes to these objectives through the deployment of clean, affordable and reliable domestic energy. To achieve U.S. wind generation objectives, the Wind and Water Power Program within the Department of Energy’s (DOE) Office of Energy Efficiency and Renewable Energy (EERE) instituted the U.S. Offshore Wind: Removing Market Barriers Program in FY 2011. Accurate and comprehensive information on offshore wind resource characteristics across a range of spatial and temporal scales is one market barrier that needs to be addressed through advanced research in remote sensing technologies. There is a pressing need for reliable offshore wind-speed measurements to assess the availability of the potential wind energy resource in terms of power production and to identify any frequently occurring spatial variability in the offshore wind resource that may impact the operational reliability and lifetime of wind turbines and their components and to provide a verification program to validate the “bankability” of the output of these alternative technologies for use by finance institutions for the financing of offshore wind farm construction. The application of emerging remote sensing technologies is viewed as a means to cost-effectively meet the data needs of the offshore wind industry. In particular, scanning and buoy mounted LIDAR have been proposed as a means to obtain accurate offshore wind data at multiple locations without the high cost and regulatory hurdles associated with the construction of offshore meteorological towers. However; before these remote sensing technologies can be accepted the validity of the measured data must be evaluated to ensure their accuracy. The proposed research will establish a unique coastal ocean test-bed in the Mid-Atlantic for the evaluation of LIDAR-based wind measurement systems to validate the accuracy of remotely measured wind data in marine applications. Specifically, the test-bed will be utilized to systematically evaluate the capability of emerging scanning LIDAR and buoy mounted vertically profiling LIDAR by: (1) Evaluating a fixed scanning LIDAR against land-based 50 and 60 meter high meteorological masts fitted with research quality cup-vane and/or sonic anemometers; (2) Evaluating a buoy mounted vertically profiling LIDAR fixed on land and floating in a sheltered bay against a co-located 60 meter high meteorological mast fitted with a research quality cup-vane and/or sonic anemometers and the fixed scanning LIDAR; and (3) Offshore field evaluation of both LIDAR platforms through a comparison of the fixed scanning LIDAR data and data obtained by the buoy mounted LIDAR located 10 miles offshore. The proposed research will systematically validate Light Detection and Ranging (LIDAR) based wind measurement systems and assess the temporal and spatial variability of the offshore wind resource in the Mid-Atlantic east of New Jersey. The goal of the proposed project is to address the technical and commercial challenges of the offshore wind energy industry by validating and assessing cost-effective, over ocean wind resource characterization technologies. The objective is to systematically evaluate the capability of both scanning and vertically profiling LIDARs to accurately measure 3D wind fields through comparison with fixed met masts and intercomparison among LIDAR platforms. Once validated, data collected by both buoy mounted vertically profiling LIDARs and shore-based, pulsed horizontally scanning LIDARs can be used to accurately assess offshore wind resources and to quantify the spatial and temporal variability in the offshore wind fields. One of the fundamental research questions to be addressed in phase 1 is the assessment of various measurement and data processing schemes to retrieve accurate wind vectors in the marine environment over large sampling ranges (10 to 12 km) and varying atmospheric aerosol levels. Atmospheric conditions and aerosol content within the coastal ocean region of the Mid-Atlantic seaboard of the US can vary significantly over short time periods in response to frontal passages and extratropical and tropical low pressure system passage offshore of the coast. Since aerosols provide the scattering medium for the determination of LIDAR Doppler shifts in the atmosphere the accuracy and range of LIDAR derived velocity measurements as a function of variation in aerosol content in the marine environment is a key research question to be addressed. In phase 1, it is desired to capture as much variation in atmospheric conditions and aerosol content as possible. To this end, collocated measurements of LIDAR and standard anemometer wind fields will be captured by the project PIs over all four seasons and during specific events (e.g., coastal low pressure system passage) in year 1. Additionally, since the meteorological masts are permanent structures, additional events can be captured over the three year duration of the field research project. All research instruments are owned by Fishermen’s Energy and made available to the PIs though a lease agreement as part of the DOE grant. Energy Fishermen’s Energy will be responsible for the operation and maintenance of the scanning LIDAR and met mast anemometers. On a daily basis, environmental data and systems performance indicators will be transmitted from each measurement station to the Fishermen’s project team consisting of both in-house personnel and equipment manufacturer engineers. Data sets include compiled LIDAR files as well as data sets from ancillary sensors. Diagnostic parameters to be monitored include standard deviations of measured values, battery levels and charging systems output, and the operational status. Once data have been confirmed as complete and reliable, files will be transferred to the Garrad Hassan (a subcontractor to Fishermen’s Energy) for incorporation in to the validation database, which is accessible to other scientific team members. Data collection times and durations will be determined by the PI and Co-PIs in consultation with instrument engineers to ensure the capture of data representative of the expected range of mid-Atlantic atmospheric conditions (e.g., temperature, moisture, coastal low pressure systems, tropical systems, rain, snow, fog). The collection and processing of the data is a function of site specific measurement requirements (Kelley et.al. 2007; Hannon et.al. 2008). To determine the optimal profiles of wind speed and direction from the LIDAR radial velocities as a function of azimuth angle, rigorous estimates of the bias and random error of each radial velocity estimate are required. Lockheed Martin Coherent Technologies, Inc., under contract with Fishermen’s Energy, will provide analyses of raw and processed data using various scan patterns to determine optimal performance settings for the pulsed scanning LIDAR. Once optimized, appropriate processing and analyses techniques will be evaluated by Garrad Hassan for use in validating the accuracy of the LIDAR wind field measurements against the standard anemometer measurements from the meteorological masts. The most attractive capability of the scanning LIDAR is the ability to provide high spatial resolution observations in a three-dimensional volume which provides superior statistical accuracy due to the large number of samples obtained. Each radial scan provides measurements in 100 range gates over a distance of 10 to 12 km at an update rate of 5 to 10 Hz and rotation of 2.5° per second. Each rotation at a fixed azimuth requires 2.4 minutes. Depending on the number of azimuths desired a complete scan can take up to 10 minutes or longer to complete. Once collected the radial velocities are processed to produce vector wind velocity estimates based on a set of data distributed in angle and range around points of interest, typically a standard grid within the radial wind map. To calculate wind vectors over a limited spatial area of interest for the comparison of data with other measurement platforms a localized least-squares approach has been applied by Hannon et.al. (2008) and a Variation Assimilation (VAR) processing technique has been applied by Chan and al Assimilation (VAR) processing technique has been applied by Chan and Shao (2006). Additionally, Kelley et.al. (2007) applied a “stare” technique that fixed a scanning LIDAR in both azimuth and elevation angles to measure over collocated sampling volumes of the LIDAR and a 3D sonic anemometer mounted to a fixed mast. Although the stare technique is limited to wind directions aligned with the sampling radial of the LIDAR, it does provide a direct comparison of sampling volumes. Each of the processing techniques described above (and possibly others) will be evaluated to determine the validity of the LIDAR derived wind fields in the marine environment. Numerical methods such as linear regression and comparison of probability density functions of wind fields measured by each instrument platform will be used to assess the processing techniques. Linear regression has the advantage of directly evaluating corresponding pairs of wind data measured by each instrument and can lend insight into deviations and bias between instruments as a function of wind speed. Assessment of the coherency between the probability density function of the wind measured by each instrument provides insight into processes that may not be accurately resolved by each instrument at specific frequencies. Once processed and assessed the most appropriate technique will be utilized to provide valid wind measurements from the pulsed scanning LIDAR. A detailed analysis of the measurement data from the LIDAR and the three meteorological towers and comparison of the coastal wind characteristics from the different systems will be performed by the CO_PI at NREL. This analysis will evaluate how the WT LIDAR performance and measurement of the wind characteristics vary with distance from the LIDAR and by atmospheric conditions; using the tower measurements at different distances (4.8, 9.6, and 19 km) from the LIDAR as a reference. The comparative analysis will include, to the extent possible, evaluation of parameters such as wind speed and direction distributions, wind shear, turbulence intensity and their variations by atmospheric conditions, month or season, and time of day.

17 WIND ENERGY↗

ADDITIVE MANUFACTURING AND REGULATORY TESTING OF CANISTERS FOR SPENT NUCLEAR FUEL MANAGEMENT

The back end of the fuel cycle focuses on the interim storage, transportation, and final disposition of the spent nuclear fuel from nuclear reactors. Commercial light water nuclear power stations across the United States operate with fuel assemblies being irradiated for up to 6 years (planned) in the reactor pressure vessel. After their planned irradiation, the fuel assemblies are moved to a spent fuel pool within the facility complex. After the spent nuclear fuel is removed from the fuel pool, it is typically inserted into a welded metal canister that can be transferred between overpacks for storage, transportation and possibly disposal. Most dry storage systems being used by industry today use dual purpose canisters (DPCs), designed for use in storage and transportation overpacks, but not specifically designed for disposal. Triple purpose-canisters, designed for disposal in addition to storage and transportation, have also been researched. Traditional manufacturing methods for spent fuel canisters involve fusion welding along the length or circumference of the canister which results in high tensile residual stresses in the joint weld zone (WZ) and heat affected zone (HAZ). In this paper, spent fuel canister designs were printed by wire arc additive manufacturing (AM) using the 316L SS welding wire to demonstrate: 1. Feasibility of spent nuclear fuel canister fabrication using this advanced manufacturing method, 2. Dynamic response of the additive manufacture canister design when subjected to the federally mandated Normal Conditions of Transport (NCT) and Hypothetical Accident Conditions (HAC) physical tests for Type B packages. This paper will focus on the canister printing design and structural tests. The AM 3D printed design, regulatory testing, and post-test evaluation of the canister tested to the 10 CFR 71.71 and 10 CFR 71.73 requirements will be presented. One AM canister design was subjected to the penetration, free drop, and puncture test. Before and after the dynamic structural tests, the AM canister design was scanned with a handheld scanner to capture a 3D CAD geometry to compare to the 3D printed canister design in the deformed shape. The scanned geometry was sectioned in areas with deformation and the cross-section profile was measured to determine accurate and repeated results of the deformed shape of the AM canister design.

Martinez, Oscar↗

TH-AB-209-12: Tissue Equivalent Phantom with Excised Human Tissue for Assessing Clinical Capabilities of Coherent Scatter Imaging Applications

Purpose: Previously we reported the development of anthropomorphic tissue-equivalent scatter phantoms of the human breast. Here we present the first results from the scatter imaging of the tissue equivalent breast phantoms for breast cancer diagnosis. Methods: A breast phantom was designed to assess the capability of coded aperture coherent x-ray scatter imaging to classify different types of breast tissue (adipose, fibroglandular, tumor). The phantom geometry was obtained from a prone breast geometry scanned on a dedicated breast CT system. The phantom was 3D printed using the segmented DICOM breast CT data. The 3D breast phantom was filled with lard (as a surrogate for adipose tissue) and scanned in different geometries alongside excised human breast tissues (obtained from lumpectomy and mastectomy procedures). The raw data were reconstructed using a model-based reconstruction algorithm and yielded the location and form factor (i.e., momentum transfer (q) spectrum) of the materials that were imaged. The measured material form factors were then compared to the ground truth measurements acquired by x-ray diffraction (XRD) imaging. Results: Our scatter imaging system was able to define the location and composition of the various materials and tissues within the phantom. Cancerous breast tissue was detected and classified through automated spectral matching and an 86% correlation threshold. The total scan time for the sample was approximately 10 minutes and approaches workflow times for clinical use in intra-operative or other diagnostic tasks. Conclusion: This work demonstrates the first results from an anthropomorphic tissue equivalent scatter phantom to characterize a coherent scatter imaging system. The functionality of the system shows promise in applications such as intra-operative margin detection or virtual biopsy in the diagnosis of breast cancer. Future work includes using additional patient-derived tissues (e.g., human fat), and modeling additional organs (e.g., lung).

60 APPLIED LIFE SCIENCES↗