Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D image processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Calculation of grain boundary normals directly from 3D microstructure images

The determination of grain boundary normals is an integral part of the characterization of grain boundaries in polycrystalline materials. These normal vectors are difficult to quantify due to the discretized nature of available microstructure characterization techniques. The most common method to determine grain boundary normals is by generating a surface mesh from an image of the microstructure, but this process can be slow, and is subject to smoothing issues. A new technique is proposed, utilizing first order Cartesian moments of binary indicator functions, to determine grain boundary normals directly from a voxelized microstructure image. In order to validate the accuracy of this technique, the surface normals obtained by the proposed method are compared to those generated by a surface meshing algorithm. Specifically, the local divergence between the surface normals obtained by different variants of the proposed technique and those generated from a surface mesh of a synthetic microstructure constructed using a marching cubes algorithm followed by Laplacian smoothing is quantified. Next, surface normals obtained with the proposed method from a measured 3D microstructure image of a Ni polycrystal are used to generate grain boundary character distributions (GBCD) for Σ3 and Σ9 boundaries, and compared to the GBCD generated using a surface mesh obtained from the same image. Finally, the results show that the proposed technique is an efficient and accurate method to determine voxelized fields of grain boundary normals.

36 MATERIALS SCIENCE↗

Using resonant soft x-ray scattering to image patterns on undeveloped resists

Copyright © 2018 SPIE. Extreme ultraviolet lithography is one of the most promising printing techniques for high volume semiconductor manufacturing at the 14 nm half-pitch device node and beyond. However, key challenges around EUV photoresist materials such as the exposure-dose sensitivity or the line-width roughness continue to impede the full adoption into industrial nanofab facilities. New metrology tools are required to address these challenges by helping to determine the impact of the EUV materials' properties and processing conditions on the roughness through the different step of the process. Here, we apply the resonant soft x-ray scattering (RSOXS) technique to gain insights into the structure of patterned EUV resists before the development step takes place. By using energies around the carbon absorption edge to take advantage of small differences in chemistry, the electronic density contrast between the exposed and unexposed regions of the resists could be enhanced in order to image the patterns with sub-nm precision. Critical-dimension grazing incidence small-angle X-ray scattering (CDGISAXS) was then performed at energies where the contrast was maximized, enabling the reconstruction of the 3D shape of the latent image. This demonstrates the potential of RSOXS to provide a high-resolution heightsensitive profile of patterned EUV resists, which will help to quantify the evolution of critical features, such as the line edge roughness, at each step of the nanofabrication process.

Pandolfi, Ronald J↗

Temporal and spatial resolution of magnetosome degradation at the subcellular level in a 3D lung carcinoma model

Magnetic nanoparticles offer many exciting possibilities in biomedicine, from cell imaging to cancer treatment. One of the currently researched nanoparticles are magnetosomes, magnetite nanoparticles of high chemical purity synthesized by magnetotactic bacteria. Despite their therapeutic potential, very little is known about their degradation in human cells, and even less so of their degradation within tumours. In an effort to explore the potential of magnetosomes for cancer treatment, we have explored their degradation process in a 3D human lung carcinoma model at the subcellular level and with nanometre scale resolution. We have used state of the art hard X-ray probes (nano-XANES and nano-XRF), which allow for identification of distinct iron phases in each region of the cell. Our results reveal the progression of magnetite oxidation to maghemite within magnetosomes, and the biosynthesis of magnetite and ferrihydrite by ferritin.

36 MATERIALS SCIENCE↗

Enabling dynamic 3D coherent diffraction imaging via adaptive latent space tuning of generative autoencoders

Abstract Coherent diffraction imaging (CDI) is an advanced non-destructive 3D X-ray imaging technique for measuring a sample’s electron density. The main challenge of CDI is loss of phase information in diffraction intensity measurements, resulting in lengthy iterative reconstruction processes that can return non-unique solutions, which pose challenges for experiments attempting to track dynamic sample evolution through multiple states. As the increased brightness of fourth-generation light sources enables faster sample measurements and drives operando experiments with Bragg CDI, there is a growing need for faster reconstruction techniques that can keep pace. We have developed an adaptive generative autoencoder approach for uniquely tracking a sample’s electron density as it dynamically evolves. Our approach adaptively tunes the low-dimensional latent embedding of a generative autoencoder, enabling a computationally efficient manner to account for time-varying shifting distributions in real-time. Analytic proof of convergence is provided as well as numerical demonstration of sample tracking with noisy measurements.

97 MATHEMATICS AND COMPUTING↗

Spatial emission tomography reconstruction using Pitman-Yor process

In this paper, we address the problem of emission tomography spatial reconstruction in three dimensions following a Bayesian nonparametric approach. Our model makes use of a generalization of the Dirichlet process called Pitman-Yor process. The problem in this approach is to deal with the infinite representation of the distribution in the inference. So we propose an efficient Markov Chain Monte-Carlo sampling scheme which is able to generate samples from the posterior distribution of the activity distribution. An application to 3D-PET reconstruction is presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MO-C-17A-03: A GPU-Based Method for Validating Deformable Image Registration in Head and Neck Radiotherapy Using Biomechanical Modeling

Purpose: Deformable image registration (DIR) plays a pivotal role in head and neck adaptive radiotherapy but a systematic validation of DIR algorithms has been limited by a lack of quantitative high-resolution groundtruth. We address this limitation by developing a GPU-based framework that provides a systematic DIR validation by generating (a) model-guided synthetic CTs representing posture and physiological changes, and (b) model-guided landmark-based validation. Method: The GPU-based framework was developed to generate massive mass-spring biomechanical models from patient simulation CTs and contoured structures. The biomechanical model represented soft tissue deformations for known rigid skeletal motion. Posture changes were simulated by articulating skeletal anatomy, which subsequently applied elastic corrective forces upon the soft tissue. Physiological changes such as tumor regression and weight loss were simulated in a biomechanically precise manner. Synthetic CT data was then generated from the deformed anatomy. The initial and final positions for one hundred randomly-chosen mass elements inside each of the internal contoured structures were recorded as ground truth data. The process was automated to create 45 synthetic CT datasets for a given patient CT. For instance, the head rotation was varied between +/− 4 degrees along each axis, and tumor volumes were systematically reduced up to 30%. Finally, the original CT and deformed synthetic CT were registered using an optical flow based DIR. Results: Each synthetic data creation took approximately 28 seconds of computation time. The number of landmarks per data set varied between two and three thousand. The validation method is able to perform sub-voxel analysis of the DIR, and report the results by structure, giving a much more in depth investigation of the error. Conclusions: We presented a GPU based high-resolution biomechanical head and neck model to validate DIR algorithms by generating CT equivalent 3D volumes with simulated posture changes and physiological regression.

60 APPLIED LIFE SCIENCES↗

Controlled activation of ZnTe:Cu contacted CdTe solar cells using rapid thermal processing

Back contacts can significantly limit CdTe solar cell performance, reducing both open circuit voltage (Voc) and fill factor (FF). Copper is an essential component of effective back contacts, but its presence in the CdTe absorber creates detrimental recombination centers. Rapid thermal processing (RTP) is demonstrated as a highly effective approach for reducing back contact barriers in CdTe solar cells contacted with ZnTe:Cu buffer layers, substantially improving both FF (473%) and V oc (4850 mV). Current density and quantum efficiency remain essentially unchanged, but a five-fold increase in minority carrier lifetime is observed which is attributed to passivation of recombination sites in the back contact region. Quantitative analysis of secondary ion mass spectrometry shows that the majority of Cu segregates to the Au metallization layer and that the ZnTe buffer appears to inhibit the Cu diffusion into CdTe. 3D imaging of the back contact region using atom probe tomography shows that optimized devices are characterized by preferential segregation of copper to both the Au|ZnTe and CdTe|ZnTe interfaces, perhaps in the form of Cu x Te. Finally, with its low thermal budget the RTP process has been successfully applied to multiple device architectures.

36 MATERIALS SCIENCE↗

SU-F-T-61: Treatment Planning Observations for the CivaSheet Directional Brachytherapy Device Using VariSeed 9.0

Purpose: The VariSeed 9.0 brachytherapy TPS is recently available and has new features such as ability to rotate a brachytherapy source away from normal to the imaging plane. Consequently, a dosimetric analysis was performed for a directional brachytherapy source (CivaSheet) with tests of this functionality and experiences from clinical treatment planning were documented. These observations contribute to safe, practical, and accurate use of such new software features. Methods: Several tests were established to evaluate the new rotational feature, specific to the CivaSheet for the first patients treated using this new brachytherapy device. These included suitability of imaging slice-thickness and in-plane resolution, window/level adjustments for brachytherapy source visualization, commissioning the source physical length for performing rotations, and using different planar and 3D window views to identify source orientation. Additional CivaSheet-specific tests were performed to determine the dosimetric influence on target coverage: changing the source tilt angle, source positioning in the treatment plan based on the CivaSheet rectangular array of CivaDots, and influence of prescription depth on the necessary treatment margin for adequate target coverage. Results: Higher imaging-resolution produced better accuracy for source orientation and positioning, with sub-millimeter CT slice-thickness and in-plane resolution preferred. Source rotation was possible only in sagittal or coronal views. The process for validating source orientation required iteratively altering rotations then checking them in the 3D view, which was cumbersome given the absence of quantitative plan documentation to indicate orientation. Given the small Pd-103 source size, influence of source tilt within 30° was negligible for <1.0 cm. Influence of source position was important when the source was positioned in/out of the adjacent source plane, causing changes of 15%, 7%, and 3% at depths of 0.5, 0.7, and 1.0 cm. Conclusion: The new TPS rotational feature worked well, but several issues were identified to improve the treatment planning process. Research supported in part by CivaTech Oncology, Inc. for Dr. Rivard.

60 APPLIED LIFE SCIENCES↗

Morphological and Electrochemical Characterization of Nanostructured Li 4 Ti 5 O 12 Electrodes Using Multiple Imaging Mode Synchrotron X-ray Computed Tomography

In this study, synchrotron X-ray computed tomography has been utilized using two different imaging modes, absorption and Zernike phase contrast, to reconstruct the real three-dimensional (3D) morphology of nanostructured Li 4 Ti 5 O 12 (LTO) electrodes. The morphology of the high atomic number active material has been obtained using the absorption contrast mode, whereas the percolated solid network composed of active material and carbon-doped polymer binder domain (CBD) has been obtained using the Zernike phase contrast mode. The 3D absorption contrast image revealed that some LTO nano-particles tend to agglomerate and form secondary micro-sized particles with varying degrees of sphericity. The tortuosity of electrode’s pore and solid phases were found to have directional dependence, different from Bruggeman’s tortuosity commonly used in macro-homogeneous models. The electrode’s heterogeneous structure was investigated by developing a numerical model to simulate galvanostatic discharge process using the Zernike phase contrast mode. The inclusion of CBD in the Zernike phase contrast results in an integrated percolated network of active material and CBD that is highly suited for continuum modeling. As a result, the simulation results highlight the importance of using the real 3D geometry since the spatial distribution of physical and electrochemical properties have a strong non-uniformity due to microstructural heterogeneities.

25 ENERGY STORAGE↗

Facile hermetic TEM grid preparation for molecular imaging of hydrated biological samples at room temperature

Abstract Although structures of vitrified supramolecular complexes have been determined at near-atomic resolution, elucidating in situ molecular structure in living cells remains a challenge. Here, we report a straightforward liquid cell technique, originally developed for real-time visualization of dynamics at a liquid-gas interface using transmission electron microscopy, to image wet biological samples. Due to the scattering effects from the liquid phase, the micrographs display an amplitude contrast comparable to that observed in negatively stained samples. We succeed in resolving subunits within the protein complex GroEL imaged in a buffer solution at room temperature. Additionally, we capture various stages of virus cell entry, a process for which only sparse structural data exists due to their transient nature. To scrutinize the morphological details further, we used individual particle electron tomography for 3D reconstruction of each virus. These findings showcase this approach potential as an efficient, cost-effective complement to other microscopy technique in addressing biological questions at the molecular level.

59 BASIC BIOLOGICAL SCIENCES↗

Nanotomography for Quantitative 3D Particle Reconstruction

Particulates are ubiquitous across fuel cycle operations and carry critical information about particle formation, processing, and potential proliferation-related activities. Traditional analytical techniques, including micro-Raman spectroscopy and standard electron microscopy, are often limited in spatial resolution or dimensionality, particularly when used to examine metallic or submicron-scale features. Understanding particle morphology, phase distribution, and internal porosity is essential for constraining formation conditions, thermodynamic environments, and material transport behavior. In this report, we demonstrate the application of plasma focused ion beam nanotomography to reconstruct micron-scale particulates at nanoscale resolution. Using high-resolution backscattered electron imaging and Avizo software, we obtained 3D reconstructions that enabled quantitative analysis of particle morphology, phase composition, and internal voids. Representative examples include a Ta particle with a large central void and a composite particle with embedded tetrahedral crystalline structures. These reconstructions reveal structural and compositional details that are inaccessible through conventional 2D imaging. The results demonstrate that nanotomography provides both qualitative and quantitative insights into particle formation and behavior. Using nanotomography, porosity and phase distributions can be quantified to inform models of particle density, transport, and solidification conditions. Beyond technical insights, the workflow developed here establishes a transferable capability for analyzing heterogeneous particles and has potential applications in bulk materials studies via x-ray computed tomography or other volumetric imaging modalities. Ongoing efforts are focused on optimizing the workflow to process multiple particles simultaneously, increasing throughput and statistical robustness. Overall, this work illustrates the power of nanotomography as a tool for connecting particulate morphology to formation mechanisms, composition, and transport, thereby strengthening analytical capabilities for nuclear forensics, fuel cycle analysis, and related scientific investigations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Synthetic fossilization of soft biological tissues and their shape-preserving transformation into silica or electron-conductive replicas

Structural preservation of complex biological systems from the subcellular to whole organism level in robust forms, enabling dissection and imaging while preserving 3D context, represents an enduring grand challenge in biology. Here we report a simple immersion method for structurally preserving intact organisms via conformal stabilization within silica. This self-limiting process, which we refer to as silica bioreplication, occurs by condensation of water-soluble silicic acid proximally to biomolecular interfaces throughout the organism. Conformal nanoscopic silicification of all biomolecular features imparts structural rigidity enabling the preservation of shape and nano-to-macroscale dimensional features upon drying to form a biocomposite and further high temperature oxidative calcination to form silica replicas or reductive pyrolysis to form electrically conductive carbon replicas of complete organisms. Ultimately, the simplicity and generalizability of this approach should facilitate efforts in biological preservation and analysis and could enable the development of new classes of biomimetic composite materials.

59 BASIC BIOLOGICAL SCIENCES↗

A large expert-curated cryo-EM image dataset for machine learning protein particle picking

Cryo-electron microscopy (cryo-EM) is a powerful technique for determining the structures of biological macromolecular complexes. Picking single-protein particles from cryo-EM micrographs is a crucial step in reconstructing protein structures. However, the widely used template-based particle picking process is labor-intensive and time-consuming. Though machine learning and artificial intelligence (AI) based particle picking can potentially automate the process, its development is hindered by lack of large, high-quality labelled training data. To address this bottleneck, we present CryoPPP, a large, diverse, expert-curated cryo-EM image dataset for protein particle picking and analysis. It consists of labelled cryo-EM micrographs (images) of 34 representative protein datasets selected from the Electron Microscopy Public Image Archive (EMPIAR). The dataset is 2.6 terabytes and includes 9,893 high-resolution micrographs with labelled protein particle coordinates. The labelling process was rigorously validated through 2D particle class validation and 3D density map validation with the gold standard. The dataset is expected to greatly facilitate the development of both AI and classical methods for automated cryo-EM protein particle picking.

42 ENGINEERING↗

The initial appraisal of buried DAS system in CO2CRC Otway Project: the comparison of buried standard fibre-optic and helically wound cables using 2D imaging

This study aims to assess the ability of shallow distributed acoustic sensing (DAS) to serve as a cost-effective seismic sensor array for permanent monitoring applications. To this end, as part of the CO2CRC seismic monitoring program, a fibre-optic DAS array was deployed alongside a permanently buried geophone array at the Otway Project site (Victoria, Australia). The DAS array consisted of a standard commercially available tactical fibre-optic cable, which was deployed in 0.8m deep trenches. A custom-designed helically wound (HW) cable was also deployed in one of the DAS trenches for comparison of the cable designs. Simultaneous acquisition of the seismic data was carried out using 3000 vibroseis source points and geophones, DAS standard and HW cables. For initial assessment of the seismic images acquired with DAS and to compare different cable designs, preliminary 2D seismic reflection processing is conducted on both DAS cables and geophone data along a single 2D line. The geophone data processing guided processing of the DAS data. Several shallow structures (100-450ms) and some important reflectors at 450-600ms are observed on the final DAS images. Comparison of the two different DAS cable types demonstrated that seismic imaging would benefit DAS technology. However, the benefit of utilising HW cable is modest compared with the standard cable. The workflows and results of this study pave the way for processing of the 3D seismic data set acquired with the DAS array, as well as further detailed analysis of the DAS cables and the system itself.

47 OTHER INSTRUMENTATION↗

Large-Format, Fully-Depleted, Back-Illuminated CMOS Imaging Technology

A Voxtel-led team has developed a new class of large-area, high-performance, backside-illuminated CMOS imaging sensor for low-light-level surveillance applications, specifically designed for both low-noise and high near-infrared (NIR) response. The imager integrates two technologies: 1) large-area backside-illuminated (BSI) imaging; and 2) high-density 3D via-less electrical interconnection and wafer bonding. In this program, Voxtel, in collaboration with Jazz Semiconductor, Sharp Labs and Ziptronix Inc., developed and fabricated a wafer-scale imaging platform. We integrated the design rules necessary for large-area photocomposition using a sub-field stitched reticle at Jazz, and wafer-scale 3D stacked electrical connect using the Ziptronix process. The Jazz CA25QFES process was shown to be ideal for use in the Ziptronix process because of its compatibility with the last via back end of line (BEOL) process used to create tungsten vias up to the wafer surface. To accomplish program goals, Voxtel integrated and fabricated a stitched CMOS ROIC design, and bonded the ROIC to an array of thick, high-resistivity, fully depleted pinned silicon photodiodes, fabricated in a silicon-on-insulator (SOI) wafer. By fabricating the detector and ROIC separately, the silicon used to fabricate the circuits from the ROIC and the fully depleted, high-resistivity silicon detector array are optimized for their respective tasks, improving their performance, increasing yield, and reducing cost.

14 SOLAR ENERGY↗

Slycat Enables Synchronized 3D Comparison of Surface Mesh Ensembles [Brief]

In support of analyst requests for Mobile Guardian Transport studies, researchers at Sandia National Laboratories have expanded data types for the Slycat ensemble-analysis and visualization tool to include 3D surface meshes. This new capability represents a significant advance in our ability to perform detailed comparative analysis of simulation results. Analyzing mesh data rather than images provides greater flexibility for post-processing exploratory analysis.

36 MATERIALS SCIENCE↗

Peregrine

The purpose of “Peregrine” is to perform in-situ quality control of the additive manufacturing process in powder bed systems. The software is an AI-based method to automatically detect and map multiple classes of defects present in the top layer of a powder bed system, either after material deposition, i.e. raking, or after printing the layer. Relying on image data or sensing modalities that can be converted into image data, the code allows for: (1) various steps of pre-processing of the data (registration, distortion correction, etc), (2) annotation of training datasets, (3) processing of data inline or offline, (4) creating 3D rendering of the defect map, and (5) implementation of corrective actions if allowed by the manufacturing platform.

Paquit, Vincent C↗