Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Geometrically projected discrete dislocation dynamics

Three-dimensional discrete dislocation dynamics methods (3D-DDD) have been developed to explicitly track the motion of individual dislocations under applied stress. At present, these methods are limited to plastic strains of about one percent or less due to high computational cost associated with the interactions between large numbers of dislocations. This limitation motivates the construction of minimalistic approaches to efficiently simulate the motion of dislocations for higher strains and longer time scales. In the present study, we propose geometrically projected discrete dislocation dynamics (GP-DDD), a method in which dislocation loops are modeled as geometrical objects that maintain their shape with a constant number of degrees of freedom as they expand. We present an example where rectangles composed of two screw and two edge dislocation segments are used for modeling gliding dislocation loops. We use this model to simulate single slip loading of copper and compare the results with detailed 3D-DDD simulations. We discuss the regimes in which GP-DDD is able to adequately capture the variation of the flow stress with strain rate in the single slip loading condition. In conclusion, a simulation using GP-DDD requires ~40 times fewer degrees of freedom for a copper single slip loading case, thus reducing computational time and complexity.

36 MATERIALS SCIENCE↗

Three-dimensional paganica fault morphology obtained from hypocenter clustering (L'Aquila 2009 seismic sequence, Central Italy)

In seismic modelling, fault planes are normally assumed to be flat due to the lack of data which can constrain fault morphology. However, incorporating 3D fault morphology is important for modelling several phenomena, for example calculating mainshock induced stress changes. Here we utilize a data-analytical method to unveil the 3D rupture morphology of faults using unsupervised clustering techniques applied to earthquake hypocenters in seismic sequences. We apply this method to the 2009 L'Aquila seismic sequence which involved a M W 6.1 mainshock on April 6th. We use a dataset of about 50,000 relocated events, mostly microearthquakes, reaching magnitude of completeness equal to 0.7. Clustering distinguishes the earthquakes as occurring in three main clusters along with other minor fault segments. We then represent the morphology of the main Paganica fault system (responsible for the largest mainshock) using splines. This method shows promise as a step toward robustly and quickly obtaining 3D rupture morphologies where earthquake sequences have been monitored. The 3D model is presented interactively online, and the processing is presented in an interactive Jupyter Notebook (https://bit.ly/2MnCFdj).

58 GEOSCIENCES↗

Progress Update on Iterative Reconstruction of Neutron Tomographic Images, 2019

The fiscal year (FY) 2019 update of this report satisfies the technical deliverable “Simultaneous reconstruction of simultaneous observables” for project OR16-ML-3DTomography-PD3Jb, “3D Tomography and Image Processing Using Fast Neutrons.” At its inception, this project had two overall goals. The first of these goals was to extend associated-particle fast neutron transmission and, particularly, induced-reaction tomographic imaging algorithms to three dimensions. The second of these goals was to automatically segment the resultant tomographic images into constituent parts and then extract information about the parts, such as the class of shape and potentially shape parameters. This report addresses the component of the project concerned with three-dimensional (3D) image reconstruction and represents the cumulative progress to date. In particular, it addresses the ability to decompose neutrons arriving at times consistent with transmission into transmission and small-angle scattering. Because incremental progress in each year builds on the previous year’s progress and end-ofyear status, progress is most usefully recorded in a cumulative document where incremental progress is reported on a year-by-year basis. Consequently, this report constitutes an update of the last 3 years’ reports [1, 2, 14]. The present year’s progress is detailed in Section 7.

47 OTHER INSTRUMENTATION↗

Multimodal Nanoscale Tomographic Imaging for Battery Electrodes

Accurate representations of the 3D structure within a lithium-ion battery are key to understanding performance limitations. However, obtaining exact reconstructions of electrodes, where the active particles, the carbon black and polymeric binder domain, and the pore space are visualized is challenging. In this work, it is shown that multimodal imaging can be used to overcome this challenge. High-resolution ptychographic X-ray computed tomography are combined with lower resolution but higher contrast transmission X-ray tomographic microscopy to obtain 3D reconstructions of pristine and cycled graphite-silicon composite electrodes. This cross-correlation enables quantitative analysis of the surface of active particles, including the heterogeneity of carbon-black and binder domain and solid-electrolyte interphase coverage. Capturing the active particles as well as the carbon black-binder domain allows using these segmented structures for electrochemical simulations to highlight the influence of the particle embedding on local state of charge heterogeneities.

25 ENERGY STORAGE↗

VANO: a volume-object image annotation system

Volume-object annotation system (VANO) is a cross-platform image annotation system that enables one to conveniently visualize and annotate 3D volume objects including nuclei and cells. An application of VANO typically starts with an initial collection of objects produced by a segmentation computation. The objects can then be labeled, categorized, deleted, added, split, merged and redefined. VANO has been used to build high-resolution digital atlases of the nuclei of Caenorhabditis elegans at the L1 stage and the nuclei of Drosophila melanogaster’s ventral nerve cord at the late embryonic stage.

59 BASIC BIOLOGICAL SCIENCES↗

Modeling the Impact of Space Suit Components and Anthropometry on the Center of Mass of a Seated Crewmember

The Crew Impact Attenuation System (CIAS) is the energy-absorbing strut concept that dampens Orion Crew Exploration Vehicle (CEV) landing loads to levels sustainable by the crew. Significant COM variations across suited crew configurations would amplify the inertial effects of the pallet and potentially create unacceptable crew loading during launch and landing. The objective of this study was to obtain data needed for dynamic simulation models by quantifying the effects of posture, suit components, and the expected range of anthropometry on the COM of a seated individual. Several elements are required for the COM calculation of a suited human in a seated position: anthropometry, body segment mass, suit component mass, suit component location relative to the body, and joint angles defining the seated posture. Three-dimensional (3D) human body models, suit mass data, and vector calculus were utilized to compute the COM positions for 12 boundary manikins in two different seated postures. The analysis focused on two objectives: (1) quantify how much the wholebody COM varied from the smallest to largest subject and (2) quantify the effects of the suit components on the overall COM in each seat configuration. The location of the anterior-posterior COM varied across all boundary manikins by about 7 cm, and the vertical COM varied by approximately 9 to 10 cm. The mediolateral COM varied by 1.2 cm from the midline sagittal plane for both seat configurations. The suit components caused an anterior shift of the total COM by approximately 2 cm and a shift to the right along the mediolateral axis of 0.4 cm for both seat configurations. When the seat configuration was in the standard posture the suited vertical COM shifted inferiorly by as much as 1 cm, whereas in the CEV posture the vertical COM had no appreciable change. These general differences were due to the high proportion of suit mass located in the boots and lower legs and their corresponding distance from the body COM, as well as to the prevalence of suit components on the right side of the body.

Blackledge, Christopher↗

An Anisotropic Fluid-Solid Model of the Mouse Heart

A critical challenge in biomechanical simulations is the spatial discretization of complex fluid-solid geometries created from imaging. This is especially important when dealing with Lagrangian interfaces, as there must be at a minimum both geometric and topological compatibility between fluid and solid phases, with exact matching of the interfacial nodes being highly desirable. We have developed a solution to this problem and applied the approach to the creation of a 3D fluidsolid mesh of the mouse heart. First, a 50 micron isotropic MRI dataset of a perfusion-fixed mouse heart was segmented into blood, tissue, and background using a customized multimaterial connected fuzzy thresholding algorithm. Then, a multimaterial marching cubes algorithm was applied to produce two compatible isosurfaces, one for the blood-tissue boundary and one for the tissue-background boundary. A multimaterial smoothing algorithm that rigorously conserves volume for each phase simultaneously smoothed the isosurfaces. Next we applied novel automated meshing algorithms to generate anisotropic hybrid meshes with the number of layers and the desired element anisotropy for each material as the only input parameters. As the meshes are scale-invariant within a material and include boundary layer prisms, fluid-structure interaction computations would have a relative error equilibrated over the entire mesh. The resulting model is highly detailed mesh representation of the mouse heart, including features such as chordae and coronary vasculature, that is also maximally efficient to produce the best simulation results for the computational resources available

59 BASIC BIOLOGICAL SCIENCES↗

Augmented DNA Nanoarchitectures: A Structural Library of 3D Self-Assembling Tensegrity Triangle Variants

The DNA tensegrity triangle is known to reliably self-assemble into a 3D rhombohedral crystalline lattice via sticky-end cohesion. Here, in this study, the library of accessible motifs is expanded through covalent extensions of intertriangle regions and sticky-end-coordinated linkages of adjacent triangles with double helical segments using both geometrically symmetric and asymmetric configurations. The molecular structures of 18 self-assembled architectures at resolutions of 3.32–9.32 Å are reported; the observed cell dimensions, cavity sizes, and cross-sectional areas agree with theoretical expectations. These data demonstrate that fine control over triclinic and rhombohedral crystal parameters and the customizability of more complex 3D DNA lattices are attainable via rational design. It is anticipated that augmented DNA architectures may be fine-tuned for the self-assembly of designer nanocages, guest–host complexes, and proscriptive 3D nanomaterials, as originally envisioned. Finally, designer asymmetric crystalline building blocks can be seen as a first step toward controlling and encoding information in three dimensions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evolution of the nanoporous microstructure of sintered Ag at high temperature using in-situ X-ray nanotomography

Silver pastes sintering is a potential candidate for die bonding in power electronic modules. The joints, obtained by sintering, exhibit a significant pore fraction, thus reducing the density of the material compared to bulk silver. The mechanical properties (Young's modulus, yield strength and ultimate tensile stress) are then drastically altered. However, while careful analysis of the nanoporous structure has been reported in 2D, little is known about its quantitative spatial evolution during thermal aging and more specifically during temperature jumps endured by the assembly during operation. High temperature evolutions of the 3D nanoporous structure have been observed in-situ using a heater fitted into the beamline 6-2c at SLAC-SSRL. Segmentation of the porosity and subsequent statistical analysis of the tomographic dataset reveal a complex evolution of the porous nanostructure including growth, separation and coalescence at a constant density. Such an analysis provides insight into the microstructural evolution of sintered nanoporous Ag joints in-service.

36 MATERIALS SCIENCE↗

Evaluation and mitigation of lightning hazards to the space shuttle Solid Rocket Motors (SRM)

The objective was to quantify electric field strengths in the Solid Rocket Motor (SRM) propellant in the event of a worst case lightning strike. Using transfer impedance measurements for selected lightning protection materials and 3D finite difference modeling, a retrofit design approach for the existing dielectric grain cover and railcar covers was evaluated and recommended for SRM segment transport. A safe level of 300 kV/m was determined for the propellant. The study indicated that a significant potential hazard exists for unprotected segments during rail transport. However, modified railcar covers and grain covers are expected to prevent lightning attachment to the SRM and to reduce the levels to several orders of magnitude below 300 kV/m.

Rigden, Gregory J.↗

3D printable liquid crystalline elastomers with tunable shape memory behavior and bio-derived renditions

Described herein are liquid crystalline elastomer compositions comprising aromatic epoxy units crosslinked with alkylene diacid units having alkylene segments containing at least one methylene unit, and/or aromatic epoxy units crosslinked with polyphenolic units, wherein the aromatic epoxy units and alkylene diacid units and/or polyphenolic units are in a molar ratio that results in the liquid crystalline elastomer composition exhibiting a glass transition temperature (Tg) and a thermal stability of the liquid crystalline phase (Tlc) that make them particularly suitable as shape memory materials and for use in methods of additive manufacturing. Methods for producing these compositions and their use in additive manufacturing processes are also described.

36 MATERIALS SCIENCE↗

Falcon: Visual analysis of large, irregularly sampled, and multivariate time series data in additive manufacturing

Flexible visual analysis of long, high-resolution, and irregularly sampled time series data from multiple sensor streams is a challenge in several domains. In the field of additive manufacturing, this capability is critical for realizing the full potential of large-scale 3D printers. Here, we propose a visual analytics approach that helps additive manufacturing researchers acquire a deep understanding of patterns in log and imagery data collected by 3D printers. Our specific goals include discovering patterns related to defects and system performance issues, optimizing build configurations to avoid defects, and increasing production efficiency. We introduce Falcon, a new visual analytics system that allows users to interactively explore large, time-oriented data sets from multiple linked perspectives. Falcon provides overviews, detailed views, and unique segmented time series visualizations, all with adjustable scale options. To illustrate the effectiveness of Falcon at providing thorough and efficient knowledge discovery, we present a practical case study involving experts in additive manufacturing and data from a large-scale 3D printer. The techniques described are applicable to the analysis of any quantitative time series, though the focus of this paper is on additive manufacturing.

97 MATHEMATICS AND COMPUTING↗

3D microwave tomography of the breast using prior anatomical information

Purpose: The authors have developed a new 3D breast image reconstruction technique that utilizes the soft tissue spatial resolution of magnetic resonance imaging (MRI) and integrates the dielectric property differentiation from microwave imaging to produce a dual modality approach with the goal of augmenting the specificity of MR imaging, possibly without the need for nonspecific contrast agents. The integration is performed through the application of a soft prior regularization which imports segmented geometric meshes generated from MR exams and uses it to constrain the microwave tomography algorithm to recover nearly uniform property distributions within segmented regions with sharp delineation between these internal subzones. Methods: Previous investigations have demonstrated that this approach is effective in 2D simulation and phantom experiments and also in clinical exams. The current study extends the algorithm to 3D and provides a thorough analysis of the sensitivity and robustness to misalignment errors in size and location between the spatial prior information and the actual data. Results: Image results in 3D were not strongly dependent on reconstruction mesh density, and the changes of less than 30% in recovered property values arose from variations of more than 125% in target region size—an outcome which was more robust than in 2D. Similarly, changes of less than 13% occurred in the 3D image results from variations in target location of nearly 90% of the inclusion size. Permittivity and conductivity errors were about 5 times and 2 times smaller, respectively, with the 3D spatial prior algorithm in actual phantom experiments than those which occurred without priors. Conclusions: The presented study confirms that the incorporation of structural information in the form of a soft constraint can considerably improve the accuracy of the property estimates in predefined regions of interest. These findings are encouraging and establish a strong foundation for using the soft prior technique in clinical studies, where their microwave imaging system and MRI can simultaneously collect breast exam data in patients.

60 APPLIED LIFE SCIENCES↗

A bronchoscopic navigation system using bronchoscope center calibration for accurate registration of electromagnetic tracker and CT volume without markers

Purpose: Various bronchoscopic navigation systems are developed for diagnosis, staging, and treatment of lung and bronchus cancers. To construct electromagnetically navigated bronchoscopy systems, registration of preoperative images and an electromagnetic tracker must be performed. This paper proposes a new marker-free registration method, which uses the centerlines of the bronchial tree and the center of a bronchoscope tip where an electromagnetic sensor is attached, to align preoperative images and electromagnetic tracker systems. Methods: The chest computed tomography (CT) volume (preoperative images) was segmented to extract the bronchial centerlines. An electromagnetic sensor was fixed at the bronchoscope tip surface. A model was designed and printed using a 3D printer to calibrate the relationship between the fixed sensor and the bronchoscope tip center. For each sensor measurement that includes sensor position and orientation information, its corresponding bronchoscope tip center position was calculated. By minimizing the distance between each bronchoscope tip center position and the bronchial centerlines, the spatial alignment of the electromagnetic tracker system and the CT volume was determined. After obtaining the spatial alignment, an electromagnetic navigation bronchoscopy system was established to real-timely track or locate a bronchoscope inside the bronchial tree during bronchoscopic examinations. Results: The electromagnetic navigation bronchoscopy system was validated on a dynamic bronchial phantom that can simulate respiratory motion with a breath rate range of 0–10 min{sup −1}. The fiducial and target registration errors of this navigation system were evaluated. The average fiducial registration error was reduced from 8.7 to 6.6 mm. The average target registration error, which indicates all tracked or navigated bronchoscope position accuracy, was much reduced from 6.8 to 4.5 mm compared to previous registration methods. Conclusions: An electromagnetically navigated bronchoscopy system was constructed with accurate registration of an electromagnetic tracker and the CT volume on the basis of an improved marker-free registration approach that uses the bronchial centerlines and bronchoscope tip center information. The fiducial and target registration errors of our electromagnetic navigation system were about 6.6 and 4.5 mm in dynamic bronchial phantom validation.

60 APPLIED LIFE SCIENCES↗

TH-A-BRF-03: Evaluation of Synthetic CTs Generated Using MR-SIM Data

Purpose: To describe and evaluate a novel algorithm for generating synthetic CT images from MR-SIM data for dose calculations in MR-only treatment planning. Methods: A voxel-based weighted summation method was implemented to generate synthetic CT (synCT) images. MR data were acquired using Philips 1.0T Panorama high-field open MR-SIM. Retrospective patient data from seven prostate patients and one brain patient (three lesions) enrolled in an IRB-approved study were used. 3D T1-weighted fast field echo and 3D T2-weighted turbo spin echo sequences were utilized for all patients. A 3D balanced turbo field echo sequence using spectral presaturation with inversion recovery was acquired for prostate patients, but 3D ultra-short echo time (UTE)-DIXON was instead acquired for the brain patient to amplify bone signal for semi-automatic bone segmentation. Weight optimization was performed using a training subset of patients. HU value differences between planning CT and synCTs were analyzed using mean absolute error (MAE). Original patient CT-based treatment plans were mapped onto synCTs, dose was recalculated using original leaf motion and MU values, and DRRs were generated. Dosevolume metrics and gamma analysis were used for dosimetric evaluation. Results: Average whole-body MAE of synCTs across all patients was 75+12 HU. In prostate cancer patients, average HU difference between planning and synCTs was 0.9±1.0% for soft tissue structures and 4.3±2.5% for bony structures. DRRs were generated from synCTs and qualitatively showed good geometric agreement with planning CT-generated DRRs. D99, mean dose, and maximum dose to CTV calculated using the synCT remained within 1.2% of planning CT-based dose calculations. All gamma analysis evaluated at 2%/2mm dose difference/distance to agreement) pass rates were greater than 95% with an average of 99.9±0.1% for prostate patients and 98.4±2.2% for three brain lesions. Conclusion: SynCTs were generated with clinically acceptable accuracy comparable to planning CTs, enabling dose computations for MR-only simulation. Research supported in part by a grant from Philips HealthCare (Best, Netherlands)

60 APPLIED LIFE SCIENCES↗

Prostate CT segmentation method based on nonrigid registration in ultrasound-guided CT-based HDR prostate brachytherapy

Purpose: The technological advances in real-time ultrasound image guidance for high-dose-rate (HDR) prostate brachytherapy have placed this treatment modality at the forefront of innovation in cancer radiotherapy. Prostate HDR treatment often involves placing the HDR catheters (needles) into the prostate gland under the transrectal ultrasound (TRUS) guidance, then generating a radiation treatment plan based on CT prostate images, and subsequently delivering high dose of radiation through these catheters. The main challenge for this HDR procedure is to accurately segment the prostate volume in the CT images for the radiation treatment planning. In this study, the authors propose a novel approach that integrates the prostate volume from 3D TRUS images into the treatment planning CT images to provide an accurate prostate delineation for prostate HDR treatment. Methods: The authors’ approach requires acquisition of 3D TRUS prostate images in the operating room right after the HDR catheters are inserted, which takes 1–3 min. These TRUS images are used to create prostate contours. The HDR catheters are reconstructed from the intraoperative TRUS and postoperative CT images, and subsequently used as landmarks for the TRUS–CT image fusion. After TRUS–CT fusion, the TRUS-based prostate volume is deformed to the CT images for treatment planning. This method was first validated with a prostate-phantom study. In addition, a pilot study of ten patients undergoing HDR prostate brachytherapy was conducted to test its clinical feasibility. The accuracy of their approach was assessed through the locations of three implanted fiducial (gold) markers, as well as T2-weighted MR prostate images of patients. Results: For the phantom study, the target registration error (TRE) of gold-markers was 0.41 ± 0.11 mm. For the ten patients, the TRE of gold markers was 1.18 ± 0.26 mm; the prostate volume difference between the authors’ approach and the MRI-based volume was 7.28% ± 0.86%, and the prostate volume Dice overlap coefficient was 91.89% ± 1.19%. Conclusions: The authors have developed a novel approach to improve prostate contour utilizing intraoperative TRUS-based prostate volume in the CT-based prostate HDR treatment planning, demonstrated its clinical feasibility, and validated its accuracy with MRIs. The proposed segmentation method would improve prostate delineations, enable accurate dose planning and treatment delivery, and potentially enhance the treatment outcome of prostate HDR brachytherapy.

60 APPLIED LIFE SCIENCES↗

The Rule of Thirds: Controlling Junction Chirality and Polarity in 3D DNA Tiles

The successful self-assembly of tensegrity triangle DNA crystals heralded the ability to programmably construct macroscopic crystalline nanomaterials from rationally-designed, nanoscale components. This 3D DNA tile owes its “tensegrity” nature to its three rotationally-stacked double helices locked together by the tensile winding of a center strand segmented into 7 base pair (bp) inter-junction regions, corresponding to two thirds of a helical turn of DNA. All reported tensegrity triangles to date have employed [Z + 2/3] turn inter-junction segments, yielding right-handed, antiparallel, “J1” junctions. Here, we report here a minimal DNA triangle motif consisting of 3-bp inter-junction segments, or one third of a helical turn. Here, we find that the minimal motif exhibits a reversed morphology with a left-handed tertiary structure mediated by a locally-parallel Holliday junction—the L1 junction. This parallel junction yields a predicted helical groove matching pattern that breaks the pseudosymmetry between tile faces, and the junction morphology further suggests a folding mechanism. We identify a Rule of Thirds by which supramolecular chirality can be programmed through inter-junction DNA segment length. These results underscore the role that global topological forces play in determining local DNA architecture and ultimately point to an under-explored class of self-assembling, chiral nanomaterials for topological processes in biological systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗