Design Simulations for a Combined Shaker-Acoustic Vibration Test Technique.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Nondestructive test method detects faulty electrical connections in inaccessible or hidden portions of electronic harness assemblies and connectors. Method employs readily available commercial equipment.
Explore the source record for details and available documents.
Sound pressure levels in the test facility were studied that are caused by varying: (1) microphone positions; (2) equalizer setting; and (3) panel clamping forces. Measurements were done by using a Beranek tube or this Beranek tube in combinations with an extension tube and a special test section. In all configurations tests were executed with and without a test panel installed. The influence of the speaker back panel and the back panel of the Beranek tube on the sound pressure levels inside the test tube were also investigated. It is shown that the definition of noise reduction is more useful in relation to this test facility than transmission loss.
A suppression prediction program based on the method of modal analysis for spinning mode propagation in a circular duct was used in the analytical design of optimized, multielement, Kevlar bulk-absorber treatment configurations for an inlet duct. The NASA-Langley ANRL anechoic chamber using the spinning mode synthesizer as a sound source was used to obtain in-duct spinning mode measurements, radial mode measurements, and far-field traverses, as well as aerodynamic measurements. The measured suppression values were compared to predicted values, using the in-duct, forward-traveling, radial-mode content as the source for the prediction. The performance of the treatment panels was evaluated from the predicted and measured data. Although experimental difficulties were encountered at the design condition, sufficient information was obtained to confirm the expectation that it is the panel impedance components which are critical to suppression at a single frequency, not the particular construction materials. The agreement obtained between measurement and prediction indicates that the analytical program can be used as an accurate, reliable, and useful design tool.
Several arrays were designed and tested. Tests included vibrational and acoustical tests, radiant heating tests, and thermal conductivity tests. A feasible manufacturing technique was established for producing the protection system panels.
A 2.1-m-diam, one-sixth-scale model helicopter main rotor was tested in hover at the NASA Ames Outdoor Aerodynamic Research Facility. It had previously been tested in hover in the NASA Ames 40- by 80-Foot Wind Tunnel test section. The primary objective of the tests was to obtain acoustic and performance data on a medium-scale rotor at various thrust coefficients and tip Mach numbers to compare to similar existing data on a full-scale helicopter main rotor. Information is presented on the effects of thrust- and tip-speed variation, the effects of boundary-layer trip strips, and the effects of wind conditions. In addition, a preliminary evaluation of the scaling of helicopter main-rotor noise in hover is presented. A secondary objective was to contribute to a data base that will permit the estimation of facility effects on acoustic testing.
Adult male Sprague-Dawley rats were exposed to chronic applied sound (74 to 79 dB, SPL) with octave band center frequencies of either 8, 16 or 32 kHz for up to 60 days. Control cages had ambient sound levels of about 62 dB (SPL). Groups of rats (test vs. control; N=9 per group) were euthanized after 0. 5. 14, 30, and 60 days. On each euthanasia day, objective evaluation of their physiology and behavior was performed using a Stress Assessment Battery (SAB) of measures. In addition, rat hearing was assessed using the brain stem auditory evoked potential (BAER) method after 60 days of exposure. No statistically significant differences in mean daily food use could be attributed to the presence of the applied test sound. Test rats used 5% more water than control rats. In the 8 kHz and 32 kHz tests this amount was statistically significant(P less than .05). This is a minor difference of questionable physiological significance. However, it may be an indication of a small reaction to the constant applied sound. Across all test frequencies, day 5 test rats had 6% larger spleens than control rats. No other body or organ weight differences were found to be statistically significant with respect to the application of sound. This spleen effect may be a transient adaptive process related to adaptation to the constant applied noise. No significant test effect on differential white blood cell counts could be demonstrated. One group demonstrated a low eosinophil count (16 kHz experiment, day 14 test group). However this was highly suspect. Across all test frequencies studied, day 5 test rats had 17% fewer total leukocytes than day 5 control rats. Sound exposed test rats exhibited 44% lower plasma corticosterone concentrations than did control rats. Note that the plasma corticosterone concentration was lower in the sound exposed test animals than the control animals in every instance (frequency exposure and number of days exposed).
No abstract available
Abstract not provided.
Silicon carbide fiber reinforced silicon carbide (SiC/SiC) composites are candidate materials for various high temperature turbine engine applications because of their high specific strength and good creep resistance at temperatures of 1400 C (2552 F) and higher. Chemical vapor infiltration (CVI) SiC/SiC ceramic matrix composites (CMC) incorporating Sylramic-iBN SiC fiber were evaluated via fast fracture tensile tests (acoustic emission damage characterization to assess cracking behavior), tensile creep testing, and microscopy. The results of this testing and observed material behavior degradation mechanisms are reviewed.
Outline: Acoustics and NDT; Nonlinear Acoustics; Time Reversal ; 3-Component Excitation; Non Contact Excitation; More Applications; Composite Materials; Metallic Samples; Concrete Evaluation; Geophysics.
Experimental results are presented for static acoustic tests of a 1/12 scale model over-the-wing target type thrust reverser. The model configuration simulates a design that is applicable to the over-the-wing short-haul advanced technology engine. Aerodynamic screening tests of a variety of reverser designs identified configurations that satisfied a reverse thrust requirement of 35 percent of forward thrust at a nozzle pressure ratio of 1.29. The variations in the reverser configuration included, blocker door angle, blocker door lip angle and shape, and side skirt shape. Acoustic data are presented and compared for the various configurations. The model data scaled to a single full size engine show that peak free field perceived noise levels at a 152.4 meter sideline distance range from 98 to 104 PNdB.
NASA Lewis Research Center recently led a multi-organizational effort to develop and test verify new acoustic blankets. These blankets support NASA's goal in reducing the Titan-4 payload fairing internal acoustic environment to allowable levels for the Cassini spacecraft. To accomplish this goal a two phase acoustic test program was utilized. Phase One consisted of testing numerous blanket designs in a flat panel configuration. Phase Two consisted of testing the most promising designs out of Phase One in a full scale cylindrical payload fairing. This paper will summarize this highly successful test program by providing the rationale and results for each test phase, the impacts of this testing on the Cassini mission, as well as providing some general information on blanket designs.
Test plan for vibration and acoustic tests on experimental shroud and payload