Search NASA⌕ Search

SEARCH · Search NASA

Results for “AIR FLOW - AIRFOILS - OSCILLATING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Fractal Model for Drag Reduction on Multiscale Nonwetting Rough Surfaces

Rough surfaces in contact with a flow of fluid exhibit alternating no-slip and free shear boundary conditions at the solid–liquid and air–liquid interfaces, respectively, thereby potentially offering drag reduction benefits. The balance between the dynamic pressure in the flow and the restoring capillary pressure in the interasperity spaces determines the stability of the Cassie state of wettability and is a function of the relative extent of no-slip and free shear regions per unit surface area. In the present study, using a fractal representation of rough surface topography, an analytical model is developed to quantify the stability of the Cassie state of wettability as well as drag reduction and the friction factor for laminar flow in a rectangular channel between nonwetting multiscale rough surfaces. A systematic study is conducted to quantify the effects of fractal parameters of the surfaces and the flow Reynolds number on drag reduction and the friction factor. The studies are used to develop friction factor curves extending the classical Moody diagram to hydrophobic and superhydrophobic surfaces. On the basis of the studies, regime maps are derived for estimating the extent of drag reduction offered by hydrophobic and superhydrophobic surfaces, revealing that superhydrophobic surfaces do not always offer the best drag reduction performance. The application of the fractal model to practical topographies of nonwetting surfaces of copper, aluminum, and zinc oxide fabricated via electrodeposition and etching is also discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Novel Framework for Performance Evaluation and Design Optimization of PCM Embedded Heat Exchangers for the Built Environment

This research sheds light on the performance evaluation and design optimization of PCM-HXs for the built environment, addressing several barriers to practical issues to PCM-HX commercialization such as modeling aspects (i.e., modeling expertise and computational / time investment, etc.), manufacturing aspects (i.e., at-scale manufacturing, cost assessments, etc.) and experimental performance assessment (i.e., reliable experimental data, assessment of multiple PCM-working fluid combinations, etc.). We present a novel, comprehensive, and experimentally-validated design optimization framework for PCM-HXs capable of simulating any PCM-HX geometry with reasonable accuracy and significant computational time savings when compared to traditional CFD-based design practices. The framework was validated for a wide range of PCM-HX configurations, including a design optimization for a domestic hot water heater application where TES partially replaces electrical heating input. The resulting PCM-HXs were found to deliver 34-68% of the total daily hot water supply with only 5-10% package volume increase from the water heater, thus within U.S. DOE targets for TES systems. To identify the most promising HXs for PCM applications, first-order geometry and cost analyses were conducted based on off-the-shelf HX products. As part of this work, 9 PCM-HX prototypes were manufactured using additive and conventional manufacturing methods. Detailed economy-of-scale assessments were conducted for the most promising PCM-HXs and were found to have a good outlook for the next 5-10 years. The PCM-HX design optimization framework was validated through comprehensive in-house experimental testing using newly-developed PCM-to-fluid test facilities. In total,10 total in-house component-level experiments were conducted using these prototypes, including 9 with water and 1 with refrigerant (R410A) as the working fluid. It was found that the framework can successfully predict experimental thermal-hydraulic performance within ±10-20% the first time without manual design changes, eliminating the need for time-consuming and expensive prototyping efforts as part of the design process. As part of this work, a publicly-available PCM web tool was released which includes a PCM property database (531 PCMs) and PCM-HX modeling tool to assist the design community on common PCM-HX use-cases, e.g., single/multiple flow path(s) fluid-to-PCM and air-to-fluid-to-PCM configurations (https://ceeeweb.umd.edu/pcmapp/). This work will accelerate the design and time to market for next generation PCM-HXs.

25 ENERGY STORAGE↗

Hybrid Large Eddy Simulation/Reynolds-Averaged Navier–Stokes Analysis of a Premixed Ethylene-Fueled Dual-Mode Scramjet Combustor

Hydrocarbon fuels offer optimal high energy per volume for scramjet applications for sustained hypersonic flight but require additional residence time due to slower ignition delays (compared with hydrogen fuel). The injection of ethylene at the start of the isolator of a dual-mode scramjet combustor, operating in ramjet mode, allows sufficient mixing to achieve efficient premixed turbulent combustion. A cavity flameholder anchors the flame, supplying sufficient radicals to sustain a stable flame in the high-speed environment. This work investigates flame structure and stabilization limits of a new configuration with a scaled-down cavity embedded in the flow path of the combustor with a strut and insert. The cavity is reduced in size by one-third to enable eventual direct numerical simulations of the flame stabilization process. This work, however, focuses on modeling the full isolator/combustor geometry using a hybrid large eddy simulation/Reynolds-averaged Navier–Stokes simulation strategy. Additionally, particle image velocimetry, planar laser-induced fluorescence, coherent anti-Stokes Raman spectroscopy, and pressure measurements are compared with numerical predictions to analyze and characterize the conditions within the combustor, including flame structure, flow velocities, species composition, and wall pressure. An adjustable air throttle in the extender is able to control the placement of the shock train in the isolator and maintain a stable flame at various equivalence ratios. The simulations show reasonably good agreement with the experimental scalar and velocity data and predict a flame angle consistent with premixed turbulent flame-speed correlations.

42 ENGINEERING↗

DNS of a Simplified Gas Turbine Premixer: Auto-Ignition and Flame Stabilization

With the increasing need for fuel-flexibility, an understanding of auto-ignition inside gas turbine premixers is crucial. Direct numerical simulation (DNS) is a great tool to reveal the fine grain details of physics inside the premixer and guide the choice of the models to use for less expensive simulations. We present numerical simulations of a simplified and downscaled premixer, with multiple air jets in rich fuel crossflow. The simulations show intense fuel-air mixing and flame-turbulence interaction. We examine flow acceleration by the incoming jets, and the combustion within the device. We observe low-temperature and high-temperature combustion signatures, and compute the flame index to quantify local stabilization modes.

combustion↗

Performance evaluation of a Terry GS-2 steam impulse turbine with air-water mixtures

Terry steam turbines are widely used in various industries because of their robust design. Within the nuclear power generation industry, they are used in the Reactor Core Isolation Cooling System to remove decay heat during reactor isolation events. During the Fukushima Daiichi nuclear power station disaster in Japan in 2011, the Reactor Core Isolation Cooling System and associated Terry turbine operated for over 70 hours in Unit 2; this runtime is well beyond the expected operating duration. Theories suggest the turbine was subjected to a two-phase inlet flow, which could degrade the turbine performance. In this work, an experimental test rig was constructed to test a full-scale Terry model GS-2 steam turbine under two-phase air/water flows. Steady-state efficiency and torque performance maps of the turbine were developed over a range of turbine inlet pressures (1.38–4.83 bar or 20–70 psia), air mass fractions (0.05–1.0) and rotational speeds up to 4000 RPM. Furthermore, turbine performance followed expected trends with torque varying linearly and efficiency varying quadratically with rotational speed. In addition, high-speed images of the two-phase flow entering the turbine were also analyzed to understand how changes in inlet pressure and air mass fraction affect the flow regime and homogenization. The present tests with air–water two-phase mixtures are an important step towards providing an understanding of the full-scale Terry turbine’s behavior and performance curves under two-phase conditions. The results of this work will be combined with air/water and steam/water data gathered using a small-scale Terry ZS-1 steam turbine in order to understand the scaling relationship between large and small size Terry turbines and fluid pairs. The combined data set will enable further development of analytical models over a wide range of conditions and may be used to provide technical justification for expanded use of the Terry turbines in nuclear power plant safety systems and other systems.

42 ENGINEERING↗

Research and Development of a Ventilation-Integrated Comfort System

From an indoor air quality perspective, the best residential ventilation strategies include filtering outdoor air and distributing that air to all occupied parts of a home. From an energy standpoint, it's desirable that energy be transferred from the exhaust air to the incoming outdoor air to limit heating and cooling impacts. Heat or energy recovery ventilation systems (HRVs or ERVs) can provide these functions, but researchers have seen many poor installations related to design, installation, and operation and maintenance. More robust ventilation systems may involve an ERV with a dedicated duct distribution system and controls. Such a duct system can be costly to install, and many builders reduce these costs by connecting an ERV to a central heating and cooling duct system. While this can sometimes be done effectively, researchers have seen consistent challenges with low, inconsistent, or imbalanced flow rates; high electricity consumption; and - of greatest concern - outdoor air short-circuiting or not being delivered to occupied spaces at all. Most ERVs are designed to operate with their own duct system; they are not designed as an add-on to much larger HVAC systems. With support from the US DOE Building Technologies Office, Steven Winter Associates, Inc. (SWA) partnered with Mitsubishi Electric Trane US, CORE Energy Recovery Solutions, and Therma-Stor LLC to design and test VICS prototypes. A conceptual diagram is shown in Figure 1, and the latest prototype (shown in Figure 2) was manufactured by Therma-Stor and tested in SWA's facility in Norwalk, CT. The ERV heat exchanger was provided by CORE, and the VICS was installed in conjunction with a 1-ton, inverter heat pump provided by Mitsubishi.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A data engineering approach for sustainable chemical end-of-life management

The presence of chemicals causing significant adverse human health and environmental effects during end-of-life (EoL) stages is a challenge for implementing sustainable management efforts and transitioning towards a safer circular life cycle. Conducting chemical risk evaluation and exposure assessment of potential EoL scenarios can help understand the chemical EoL management chain for its safer utilization in a circular life-cycle environment. However, the first step is to track the chemical flows, estimate releases, and potential exposure pathways. Hence, this work proposes an EoL data engineering approach to perform chemical flow analysis and screening to support risk evaluation and exposure assessment for designing a safer circular life cycle of chemicals. This work uses publicly-available data to identify potential post-recycling scenarios (e.g., industrial processing/use operations), estimate inter-industry chemical transfers, and exposure pathways to chemicals of interest. Furthermore, a case study demonstration shows how the data engineering framework identifies, estimates, and tracks chemical flow transfers from EoL stage facilities (e.g., recycling and recovery) to upstream chemical life cycle stage facilities (e.g., manufacturing). Also, the proposed framework considers current regulatory constraints on closing the recycling loop operations and provides a range of values for the flow allocated to post-recycling uses associated with occupational exposure and fugitive air releases from EoL operations.

54 ENVIRONMENTAL SCIENCES↗

Measurement and analysis of clothes dryer air leakage

Each year clothes dryer appliances are sold globally in the tens of millions. Both vented and ventless types are common and are heated by combustion, electric resistance, or electric heat pumps. In the dyer air path, segments can be defined between components such as the drum, blower, filter, screens or grills, and heat exchangers (where applicable). In this work, a technique was developed to experimentally measure air leakage into and from the segments of a clothes dryer. Detailed leakage measurements were taken on two vented and one ventless residential clothes dryer. The measurements were quantified as a leakage flow coefficient for each segment. For two dryers (one vented and one ventless), these flow coefficients were combined with in situ operating pressure measurements to determine leakage flow rates for each segment. For these two units under normal operation with air pressures within 0.5 kPa (50 mm water column) of ambient pressure, volumetric system air leakage was found to be about 20–60% of the blower airflow. Furthermore, a quasi–steady state psychrometric analysis was conducted on vented dryers with negatively pressurized drums. The analysis revealed that leakage quantity, location, and direction are essential to achieving an acceptable energy balance and accurate modeling results for a vented heat pump clothes dryer but are of limited significance for vented electric resistance clothes dryers.

42 ENGINEERING↗

Vorticity-induced flow-focusing leads to bubble entrainment in an inkjet printhead: Synchrotron x-ray and volume-of-fluid visualizations

The oscillatory flows present in an inkjet printhead can lead to strong deformations of the air-liquid interface at the nozzle exit. Such deformations may lead to an inward directed air jet with bubble pinch-off and the subsequent entrainment of an air bubble, which is highly detrimental to the stability of inkjet printing. Understanding the mechanisms of bubble entrainment is therefore crucial to improving print stability. Here, in the present work, we use ultrafast x-ray phase-contrast imaging and direct numerical simulations based on the volume-of-fluid method to study the mechanisms underlying the bubble entrainment in a piezoacoustic printhead. We first demonstrate good agreement between experiments and numerics. We then show the different classes of bubble pinch-off obtained in experiments, and that those were also captured numerically. The numerical results are then used to show that the baroclinic torque, which is generated at the gas-liquid interface due to the misalignment of density and pressure gradients, results in a flow-focusing effect that drives the formation of the air jet from which a bubble can pinch off.

42 ENGINEERING↗

Flexible cryogenic air separation unit—An application for low-carbon fossil-fuel plants

In this study, the rapid integration of intermittent renewable sources into the electricity grid is driving the need for a flexible cryogenic air separation unit (ASU) coupled with a low-carbon fossil-fuel plant. However, the state-of-the-art ASU process is highly integrated and nonlinear, which can significantly restrict its ramping rate. In this work, we study the fundamental dynamics of a state-of-the-art double-column ASU, focusing on the dynamic characteristics of the highly integrated and nonlinear heat and mass transfers, and we propose basic control methods for achieving high process ramping rates. We found that the vapor–liquid countercurrent flows in the low-pressure column are critical to the cryogenic rectification of air, which governs the ramp rate of the ASU. This countercurrent flow structure is created through a complex heat integration process in the ASU. Here, this process is simplified as a countercurrent heat transfer to reduce the complexity of studying the ASU dynamics. To preserve this flow structure, the heat integration is maintained so that its heat duty follows the ASU load, using several basic controllers on the critical stream flowrates. A flow-driven dynamic ASU model is built in Aspen Plus Dynamics to capture the basic ramping dynamics. This model revealed a fundamental mismatch in the dynamics in the ASU column that causes a significant loss of O 2 product purity when ramping down the ASU and slightly increases the purity when ramping up. Based on these findings, we propose a basic control method for rapidly ramping down/up the ASU while maintaining O 2 product purity. Simulation results show the ASU basic dynamic process successfully ramps at a rate up to 10 %/min (40–100 % load) while maintaining the O 2 product purity at 95.2–95.6 mol%.

42 ENGINEERING↗

Assessment of the 3420 Building Filtered Exhaust Stack Sampling Probe Location: Stack Verification Following Fan and Air Blender Additions

The Pacific Northwest National Laboratory (PNNL) 3420 Building, which is part of the Physical Sciences Facility (PSF), houses radiological capabilities that results in the requirement that emissions monitoring must be conducted for potential radionuclides in the exhaust air discharge of this building. The air monitoring system is required to conform to Title 40 of the Code of Federal Regulations part 61 (40 CFR 61) Subpart H, which in turns requires a sampling probe in the exhaust stream to conform to the criteria of American National Standards Institute / Health Physics Society (ANSI/HPS) N13.1-2011, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. To support the air emissions permit for the 3420 Building on the PNNL campus, stack testing that used computational fluid dynamics (CFD) modeling as a surrogate stack and verification tests of velocity uniformity and flow angle on the retrofitted facility stack was performed. The ANSI/HPS N13.1-2011 criteria for the air monitoring probe location are that velocity uniformity, gaseous tracer uniformity, and particulate tracer uniformity must be less than or equal to 20%COV. Furthermore, no point in the sampling location may have a gaseous tracer concentration that varies from the mean concentration by more than 30%. Additionally, the flow angle at the sampling location must not be more than 20°. The CFD modeling of the stack, as reported by Recknagle et al. (2018) demonstrated that the stack meets the criteria at the probe location. The velocity uniformity and flow angle results from the 3420 stack verification tests, performed in October 2020, demonstrated that the CFD model results may be used to support the qualification of the stack sampling location. The measured velocity uniformity verification test result was 1.4%COV. This value is well within the uniformity criterion, which is that the velocity uniformity be =20%COV. Additionally, this value is well within the criterion that the actual stack measurement must be within 5% of the surrogate stack result of 2.1%COV when all four fans were operating. Additionally, the measured average flow angle at the 3420 stack monitor location was 15.5 degrees. Although this is higher than expected based on the CFD model, the result is =20 degrees, so the criterion is met. Based on these stack verification test results, the reconfigured 3420 Building filtered exhaust stack meets the qualification criteria given in the ANSI/HPS N13.1-2011 standard. Further changes to the system configuration or operating conditions that are outside the bounds described in this and the CFD report (Recknagle et al., 2018) may require additional tests and additional analysis to determine compliance with the standard.

3420 Building↗

Going mobile to address emerging climate equity needs in the heterogeneous urban environment

We report the Brookhaven National Laboratory Center for Multiscale Applied Sensing (CMAS) aims to address environmental equity needs in the context of a changing climate. As a first step towards this goal, the center developed a one-of-a-kind observatory tailored to the study of highly heterogeneous urban environments. This article describes the features of the mobile observatory that enable its rapid deployment either on or off the power grid, as well as its instrument payload. Beyond its unique design, the observatory optimizes data collection within the obstacle-laden urban environment using a new smart sampling paradigm. This setup facilitated the collection of previously poorly documented environmental properties including wind profiles throughout the atmospheric column. The mobile observatory captured unique observations during its first few intensive observation periods (IOPs).. Vertical air motion and infrared temperature measurements collected along the faces of the supertall One Vanderbilt skyscraper in Manhattan, NY reveal how solar and anthropogenic heating affect wind flow and thus the venting of heat, pollution, and contaminants in urban street canyons. Also, air temperature measurements collected during travel along a 150-km transect between Upton and Manhattan, NY offer a high-resolution view of the urban heat island and reveal that temperature disparities also exist within the city across different neighborhoods. Ultimately, the datasets collected by CMAS are poised to help guide equitable urban planning by highlighting existing disparities and characterizing the impact of urban features on the urban microclimate with the goal of improving human comfort.

54 ENVIRONMENTAL SCIENCES↗

Data used in manuscript "Quantifying Subsurface Flow and Solute Transport in a Snowmelt-recharged Hillslope with Multiyear Water Balance", submitted to Water Resources Research on 5-26-2022

Data in this package were used to calculate subsurface flow and solute (specifically dissolved nitrogen) transport in the Pumphouse Lower Montane (PLM) hillslope. These data are included in separate CSV files associated with each figure presented in the manuscript. The files describe site locations and elevations, weather data (air temperatures and precipitation), modeled evapotranspiration, time dependent groundwater elevations, calculated annual subsurface flow, hydraulic conductivity values, time trends in subsurface flow within different zones, pore water concentrations of total dissolve nitrogen (TDN), rates of TDN transport, soil water matric potentials following snowmelt, soil water contents during drainage, and evapotranspiration calculated by soil water mass balance versus by CLM4 model.

54 ENVIRONMENTAL SCIENCES↗

A review on the state of thermal hydraulics research on air ingress scenarios in High-Temperature Gas-cooled Reactors following a D-LOFC

With the expectation of near-immediate carbon neutrality, widespread implementation of proven High-Temperature Gas-cooled Reactors (HTGRs) embodies a viable solution pathway given their inherent, passive safety features and high thermal efficiency. This study provides an overview of the current state of research involving the thermal hydraulics associated with air ingress from a depressurized loss of forced cooling (D-LOFC) in HTGRs. Accurately characterizing and predicting the physical phenomena underlying air ingress is of paramount concern, as the integrity of the fuel and core graphite support structures are threatened by the presence of oxygen. Broadly speaking, the air ingress scenario can be delineated into three main stages: (1) Depressurization, (2) Density-Driven Flow, and (3) Natural Convection. In tandem with the underlying fundamental theory, this review collates and synthesizes the existing body of contemporary research concerning the air ingress scenario following a D-LOFC. As evinced by this review, our current understanding and predictive abilities have benefited from extensive research, predominantly concentrated on the rate of air ingestion into the core. Here, additional research is necessary to holistically capture the phenomenology of an air ingress scenario following a D-LOFC by considering an additional variable: the oxygen content of the ingressing air. The latter variable requires investigation into the complex interactions of the fully integrated system. Additionally, while numerical tools are evolving domestically through the Nuclear Energy Advanced Modeling and Simulation program, a sufficiently validated code remains absent.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Application of reference-free natural background–oriented schlieren photography for visualizing leakage sites in building walls

Air leakage in buildings can cause health and comfort concerns for occupants and can contribute to mold growth on building materials, or in extreme conditions, rot of building materials. Unwanted air leakage through the building envelope also contributes to approximately 4 quadrillion Btu (1172 TWh) of energy consumption per year in the building sector in the United States. Locating and sealing leakage sites can improve the energy efficiency, comfort, air quality, and moisture durability of the building stock. Typical methods of finding leakage sites, such as infrared imaging and smoke tracing, rely on concurrent blower door operation, which can also measure the total leakage rate of the building. Smoke tracing can be disruptive to occupants, and infrared imaging and smoke tracing cannot measure the contribution of individual leaks to prioritize sealing efforts. Here, an optical fluid flow imaging technique, reference-free natural background–oriented schlieren imaging, was adapted to visualize air exfiltration. This is the first step in developing a method to noninvasively locate and measure exfiltration or infiltration sites so that sealing efforts can be prioritized. Experimental results of this technique are presented, demonstrating the method's applicability to visualizing exfiltration through three common building claddings in an outdoor environment. Key variables impacting the performance of this technique when applied to building leakage are also discussed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Spatially Mapping the CO 2 Alkaline Sorbent Diffuse Microenvironment Using Operando Raman Spectroscopy

When designing a chemical process, the local balance of transport and kinetics, collectively referred to as the diffuse microenvironment, plays a critical role in performance but is difficult to directly observe. This work demonstrates a method of two-dimensional spatial chemical mapping of the diffuse microenvironment in the context of alkali metal hydroxide direct air capture of carbon dioxide using a custom operando gas-absorption flow cell along with confocal Raman spectroscopy. Notably, we observe the concentration boundary layer near the gas–liquid interface and elucidate the interplay of carbonate and bicarbonate ions within it while inferring local hydroxide depletion through continuum modeling. These first of their kind observations provide a technique to compare the performance of direct air capture solvents based on diffuse microenvironment dynamics while also providing metrics important for air contactor design such as boundary layer thickness. Overall, this work showcases a new experimental platform to study interfacial diffuse microenvironments in and outside of the field of direct air capture of carbon dioxide.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance study of the cross-flow Maisotsenko cycle in humid climate conditions

This paper presents a first numerical analysis of the cross-flow Maisotsenko cycle (M-Cycle) below dew-point evaporative cooler for humid climates with model including the water vapor condensation phenomenon. Proposed solution allows to cool ambient air below its dew-point temperature, by utilizing cooling energy in air extracted from the building, due to that it can be used as effective pre-cooling solution for traditional systems. Proposed unit has significant advantage over traditional counter and cross-flow units operating in heat recovery mode, hence it is almost insensitive on temperature of exhaust air. This is caused by effective pre-cooling of the exhaust air in its initial part. Operation in humid climates using cold extracted air results in condensation occurrence in the primary air channels, and hence partial dehumidification of the primary airflow (which allows to cool the air before its dew- point temperature). The Maisotsenko cycle exchanger used to recover heat in the air-conditioning system is compared with Maisotsenko exchanger that operates only on the ambient airflow and does not allow to recover heat from the exhaust airflow from a conditioned space. Achieved results showed that M-Cycle below dew-point air cooler can operate more effectively in humid climates than traditional cross-flow Maisotsenko cycle exchanger.

Condensation↗

Modeling and Optimization of a Rotating Packed Bed Contactor with a Tetraamine-Appended Metal−Organic Framework for CO 2 Capture

A potential contactor technology for sorbent-based CO 2 capture is the rotating packed bed that contains separate sections for continuous adsorption and desorption. A heat exchanger can be embedded to remove heat in the adsorption section and add heat in the desorption section. In this work, we develop a two-dimensional (2D) model of a rotating packed bed for use in CO 2 capture applications. Mass and energy balances for the model are developed based on a Ljungström-type air preheater, which accounts for the counter-current axial flow of gas phases in separate sections of the bed and the rotation of a solid sorbent, which cycles between adsorption and desorption sections. The sorbent used for this analysis is the tetraamine-appended metal−organic framework Mg 2 (dobpdc)(3−4− 3), chosen for its stability and affinity for CO 2 at low partial pressures, such as those from a natural gas power plant source. An optimization problem is solved that considers the trade-off between maximizing the productivity of the bed and minimizing energy consumption. Maximum productivity and minimum energy are found to be 8.53 kg/h/m 3 and 3.84 MJ/kg, respectively, when these objectives are optimized independently. It is observed that the flue gas pressure and bed rotational speed are the desired operating variables to vary for model-based design of experiments to reduce uncertainty in parameter estimation, as these two variables yielded the most information content based on the Fisher information matrix.

20 FOSSIL-FUELED POWER PLANTS↗