Search NASA⌕ Search

SEARCH · Search NASA

Results for “AIR FLOW - COMPRESSIBILITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Assessment of the 3420 Building Filtered Exhaust Stack Sampling Probe Location: Stack Verification Following Fan and Air Blender Additions

The Pacific Northwest National Laboratory (PNNL) 3420 Building, which is part of the Physical Sciences Facility (PSF), houses radiological capabilities that results in the requirement that emissions monitoring must be conducted for potential radionuclides in the exhaust air discharge of this building. The air monitoring system is required to conform to Title 40 of the Code of Federal Regulations part 61 (40 CFR 61) Subpart H, which in turns requires a sampling probe in the exhaust stream to conform to the criteria of American National Standards Institute / Health Physics Society (ANSI/HPS) N13.1-2011, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. To support the air emissions permit for the 3420 Building on the PNNL campus, stack testing that used computational fluid dynamics (CFD) modeling as a surrogate stack and verification tests of velocity uniformity and flow angle on the retrofitted facility stack was performed. The ANSI/HPS N13.1-2011 criteria for the air monitoring probe location are that velocity uniformity, gaseous tracer uniformity, and particulate tracer uniformity must be less than or equal to 20%COV. Furthermore, no point in the sampling location may have a gaseous tracer concentration that varies from the mean concentration by more than 30%. Additionally, the flow angle at the sampling location must not be more than 20°. The CFD modeling of the stack, as reported by Recknagle et al. (2018) demonstrated that the stack meets the criteria at the probe location. The velocity uniformity and flow angle results from the 3420 stack verification tests, performed in October 2020, demonstrated that the CFD model results may be used to support the qualification of the stack sampling location. The measured velocity uniformity verification test result was 1.4%COV. This value is well within the uniformity criterion, which is that the velocity uniformity be =20%COV. Additionally, this value is well within the criterion that the actual stack measurement must be within 5% of the surrogate stack result of 2.1%COV when all four fans were operating. Additionally, the measured average flow angle at the 3420 stack monitor location was 15.5 degrees. Although this is higher than expected based on the CFD model, the result is =20 degrees, so the criterion is met. Based on these stack verification test results, the reconfigured 3420 Building filtered exhaust stack meets the qualification criteria given in the ANSI/HPS N13.1-2011 standard. Further changes to the system configuration or operating conditions that are outside the bounds described in this and the CFD report (Recknagle et al., 2018) may require additional tests and additional analysis to determine compliance with the standard.

3420 Building↗

Going mobile to address emerging climate equity needs in the heterogeneous urban environment

We report the Brookhaven National Laboratory Center for Multiscale Applied Sensing (CMAS) aims to address environmental equity needs in the context of a changing climate. As a first step towards this goal, the center developed a one-of-a-kind observatory tailored to the study of highly heterogeneous urban environments. This article describes the features of the mobile observatory that enable its rapid deployment either on or off the power grid, as well as its instrument payload. Beyond its unique design, the observatory optimizes data collection within the obstacle-laden urban environment using a new smart sampling paradigm. This setup facilitated the collection of previously poorly documented environmental properties including wind profiles throughout the atmospheric column. The mobile observatory captured unique observations during its first few intensive observation periods (IOPs).. Vertical air motion and infrared temperature measurements collected along the faces of the supertall One Vanderbilt skyscraper in Manhattan, NY reveal how solar and anthropogenic heating affect wind flow and thus the venting of heat, pollution, and contaminants in urban street canyons. Also, air temperature measurements collected during travel along a 150-km transect between Upton and Manhattan, NY offer a high-resolution view of the urban heat island and reveal that temperature disparities also exist within the city across different neighborhoods. Ultimately, the datasets collected by CMAS are poised to help guide equitable urban planning by highlighting existing disparities and characterizing the impact of urban features on the urban microclimate with the goal of improving human comfort.

54 ENVIRONMENTAL SCIENCES↗

Data used in manuscript "Quantifying Subsurface Flow and Solute Transport in a Snowmelt-recharged Hillslope with Multiyear Water Balance", submitted to Water Resources Research on 5-26-2022

Data in this package were used to calculate subsurface flow and solute (specifically dissolved nitrogen) transport in the Pumphouse Lower Montane (PLM) hillslope. These data are included in separate CSV files associated with each figure presented in the manuscript. The files describe site locations and elevations, weather data (air temperatures and precipitation), modeled evapotranspiration, time dependent groundwater elevations, calculated annual subsurface flow, hydraulic conductivity values, time trends in subsurface flow within different zones, pore water concentrations of total dissolve nitrogen (TDN), rates of TDN transport, soil water matric potentials following snowmelt, soil water contents during drainage, and evapotranspiration calculated by soil water mass balance versus by CLM4 model.

54 ENVIRONMENTAL SCIENCES↗

A review on the state of thermal hydraulics research on air ingress scenarios in High-Temperature Gas-cooled Reactors following a D-LOFC

With the expectation of near-immediate carbon neutrality, widespread implementation of proven High-Temperature Gas-cooled Reactors (HTGRs) embodies a viable solution pathway given their inherent, passive safety features and high thermal efficiency. This study provides an overview of the current state of research involving the thermal hydraulics associated with air ingress from a depressurized loss of forced cooling (D-LOFC) in HTGRs. Accurately characterizing and predicting the physical phenomena underlying air ingress is of paramount concern, as the integrity of the fuel and core graphite support structures are threatened by the presence of oxygen. Broadly speaking, the air ingress scenario can be delineated into three main stages: (1) Depressurization, (2) Density-Driven Flow, and (3) Natural Convection. In tandem with the underlying fundamental theory, this review collates and synthesizes the existing body of contemporary research concerning the air ingress scenario following a D-LOFC. As evinced by this review, our current understanding and predictive abilities have benefited from extensive research, predominantly concentrated on the rate of air ingestion into the core. Here, additional research is necessary to holistically capture the phenomenology of an air ingress scenario following a D-LOFC by considering an additional variable: the oxygen content of the ingressing air. The latter variable requires investigation into the complex interactions of the fully integrated system. Additionally, while numerical tools are evolving domestically through the Nuclear Energy Advanced Modeling and Simulation program, a sufficiently validated code remains absent.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Application of reference-free natural background–oriented schlieren photography for visualizing leakage sites in building walls

Air leakage in buildings can cause health and comfort concerns for occupants and can contribute to mold growth on building materials, or in extreme conditions, rot of building materials. Unwanted air leakage through the building envelope also contributes to approximately 4 quadrillion Btu (1172 TWh) of energy consumption per year in the building sector in the United States. Locating and sealing leakage sites can improve the energy efficiency, comfort, air quality, and moisture durability of the building stock. Typical methods of finding leakage sites, such as infrared imaging and smoke tracing, rely on concurrent blower door operation, which can also measure the total leakage rate of the building. Smoke tracing can be disruptive to occupants, and infrared imaging and smoke tracing cannot measure the contribution of individual leaks to prioritize sealing efforts. Here, an optical fluid flow imaging technique, reference-free natural background–oriented schlieren imaging, was adapted to visualize air exfiltration. This is the first step in developing a method to noninvasively locate and measure exfiltration or infiltration sites so that sealing efforts can be prioritized. Experimental results of this technique are presented, demonstrating the method's applicability to visualizing exfiltration through three common building claddings in an outdoor environment. Key variables impacting the performance of this technique when applied to building leakage are also discussed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Spatially Mapping the CO 2 Alkaline Sorbent Diffuse Microenvironment Using Operando Raman Spectroscopy

When designing a chemical process, the local balance of transport and kinetics, collectively referred to as the diffuse microenvironment, plays a critical role in performance but is difficult to directly observe. This work demonstrates a method of two-dimensional spatial chemical mapping of the diffuse microenvironment in the context of alkali metal hydroxide direct air capture of carbon dioxide using a custom operando gas-absorption flow cell along with confocal Raman spectroscopy. Notably, we observe the concentration boundary layer near the gas–liquid interface and elucidate the interplay of carbonate and bicarbonate ions within it while inferring local hydroxide depletion through continuum modeling. These first of their kind observations provide a technique to compare the performance of direct air capture solvents based on diffuse microenvironment dynamics while also providing metrics important for air contactor design such as boundary layer thickness. Overall, this work showcases a new experimental platform to study interfacial diffuse microenvironments in and outside of the field of direct air capture of carbon dioxide.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance study of the cross-flow Maisotsenko cycle in humid climate conditions

This paper presents a first numerical analysis of the cross-flow Maisotsenko cycle (M-Cycle) below dew-point evaporative cooler for humid climates with model including the water vapor condensation phenomenon. Proposed solution allows to cool ambient air below its dew-point temperature, by utilizing cooling energy in air extracted from the building, due to that it can be used as effective pre-cooling solution for traditional systems. Proposed unit has significant advantage over traditional counter and cross-flow units operating in heat recovery mode, hence it is almost insensitive on temperature of exhaust air. This is caused by effective pre-cooling of the exhaust air in its initial part. Operation in humid climates using cold extracted air results in condensation occurrence in the primary air channels, and hence partial dehumidification of the primary airflow (which allows to cool the air before its dew- point temperature). The Maisotsenko cycle exchanger used to recover heat in the air-conditioning system is compared with Maisotsenko exchanger that operates only on the ambient airflow and does not allow to recover heat from the exhaust airflow from a conditioned space. Achieved results showed that M-Cycle below dew-point air cooler can operate more effectively in humid climates than traditional cross-flow Maisotsenko cycle exchanger.

Condensation↗

Modeling and Optimization of a Rotating Packed Bed Contactor with a Tetraamine-Appended Metal−Organic Framework for CO 2 Capture

A potential contactor technology for sorbent-based CO 2 capture is the rotating packed bed that contains separate sections for continuous adsorption and desorption. A heat exchanger can be embedded to remove heat in the adsorption section and add heat in the desorption section. In this work, we develop a two-dimensional (2D) model of a rotating packed bed for use in CO 2 capture applications. Mass and energy balances for the model are developed based on a Ljungström-type air preheater, which accounts for the counter-current axial flow of gas phases in separate sections of the bed and the rotation of a solid sorbent, which cycles between adsorption and desorption sections. The sorbent used for this analysis is the tetraamine-appended metal−organic framework Mg 2 (dobpdc)(3−4− 3), chosen for its stability and affinity for CO 2 at low partial pressures, such as those from a natural gas power plant source. An optimization problem is solved that considers the trade-off between maximizing the productivity of the bed and minimizing energy consumption. Maximum productivity and minimum energy are found to be 8.53 kg/h/m 3 and 3.84 MJ/kg, respectively, when these objectives are optimized independently. It is observed that the flue gas pressure and bed rotational speed are the desired operating variables to vary for model-based design of experiments to reduce uncertainty in parameter estimation, as these two variables yielded the most information content based on the Fisher information matrix.

20 FOSSIL-FUELED POWER PLANTS↗

A low power flexible dielectric barrier discharge disinfects surfaces and improves the action of hydrogen peroxide

There is an urgent need for disinfection and sterilization devices accessible to the public that can be fulfilled by innovative strategies for using cold atmospheric pressure plasmas. Here, we demonstrate a successful novel combination of a flexible printed circuit design of a dielectric barrier discharge (flex-DBD) with an environmentally safe chemical reagent for surface decontamination from bacterial contaminants. Flex-DBD operates in ambient air, atmospheric pressure, and room temperature without any additional gas flow at a power density not exceeding 0.5 W/cm 2 . The flex-DBD activation of a 3% hydrogen peroxide solution results in the reduction in the bacterial load of a surface contaminant of > 6log 10 in 90 s, about 3log 10 and 2log 10 better than hydrogen peroxide alone or the flex-DBD alone, respectively, for the same treatment time. We propose that the synergy between plasma and hydrogen peroxide is based on the combined action of plasma-generated OH · radicals in the hydrogen peroxide solution and the reactive nitrogen species supplied by the plasma effluent. A scavenger method verified a significant increase in OH · concentration due to plasma treatment. Novel in-situ FTIR absorption spectra show the presence of O 3 , NO 2 , N 2 O, and other nitrogen species. Ozone dissolving in the H 2 O 2 solution can effectively generate OH · through a peroxone process. The addition of the reactive nitrogen species increases the disinfection efficiency of the hydroxyl radicals and other oxygen species. Hence, plasma activation of a low concentration hydrogen peroxide solution, using a hand-held flexible DBD device results in a dramatic improvement in disinfection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Routes to roots: direct evidence of water transport by arbuscular mycorrhizal fungi to host plants

Summary Arbuscular mycorrhizal fungi (AMF) can help mitigate plant responses to water stress, but it is unclear whether AMF do so by indirect mechanisms, direct water transport to roots, or a combination of the two. Here, we investigated if and how the AMF Rhizophagus intraradices transported water to the host plant Avena barbata , wild oat. We used two‐compartment microcosms, isotopically labeled water, and a fluorescent dye to directly track and quantify water transport by AMF across an air gap to host plants. Plants grown with AMF that had access to a physically separated compartment containing 18 O‐labeled water transpired almost twice as much as plants with AMF excluded from that compartment. Using an isotopic mixing model, we estimated that water transported by AMF across the air gap accounted for 34.6% of the water transpired by host plants. In addition, a fluorescent dye indicated that hyphae were able to transport some water via an extracytoplasmic pathway. Our study provides direct evidence that AMF can act as extensions of the root system along the soil–plant–air continuum of water movement, with plant transpiration driving water flow along hyphae outside of the hyphal cell membrane.

59 BASIC BIOLOGICAL SCIENCES↗

Process Failure Detection via Recurrence Quantification Analysis in a Slot-Rectangular Spouted Bed

A study was conducted to explore the applicability of recurrence and recurrence quantification analysis (RQA) to the detection of process failures in spouted bed reactor systems. Here, three different potential failure modes were examined in a transparent, cold flow slot-rectangular spouted bed. These being, a simulated air leak from a side wall of the reactor, a simulated gas leak from the top wall of the reactor, and simulated agglomeration of solids via introduction of larger “klinker” particles. Bed pressure drop time history data were collected and analyzed via generation of recurrence plots (RPs) and RQA parameters. In general, the simulated agglomeration case was quite easily detected via ever RQA Parameter examined, whereas the simulated air leaks were detected by only a single RQA parameter.

30 DIRECT ENERGY CONVERSION↗

Low Particulates Nitrogen Purge and Backfill During pHB650 Cryomodule String Assembly

A low particulate vacuum and purging system was developed to support PIP-II cryomodule string assembly. The overpressure can be controlled at a precision of 1 mbar above the atmospheric pressure regardless of the cavity or string assembly air volume. The system minimized the risk of uncontrolled nitrogen flow during the string assembly. Design features are presented.

Ring, T.↗

CFD simulations of electric motor end ring cooling for improved thermal management

Proper thermal management of an electric motor for vehicle applications extends its operating range. One cooling approach is to impinge Automatic Transmission Fluid (ATF) onto the rotor end ring. Increased ATF coverage correlates to enhanced heat transfer. Computational Fluid Dynamics (CFD) analytical tools provide a mechanism to assess motor thermal management prior to hardware fabrication. The complexity of the fluid flow (e.g., jet atomization, interface tracking, wall impingement) and heat transfer makes these simulations challenging. Computational costs are high when solving these flows on high-speed rotating meshes. Typically, a Volume-of Fluid (VOF) technique (i.e., two-fluid system) is used to resolve ATF dynamics within this rotating framework. Suitable numerical resolution of the relevant physics for thin films under strong inertial forces at high rotor speeds is computationally expensive, further increasing the run times. In this work, a numerical study of rotor-ring cooling by ATF is presented using a patent automated Cartesian cut-cell based method coupled with Automatic Mesh Refinement (AMR). This approach automatically creates the Cartesian mesh on-the-fly and can effectively handle complex rotating geometries by adaptively refining the mesh based on local gradients in the flow field which results in better resolution of the air-ATF interface. A Single non-inertial Reference Frame (SRF) approach is used to account for the rotating geometry and to further improve the overall computational efficiency. Quasi-steady state conditions are targeted in the analysis of the results. Important physics such as ATF jet structure, velocity detail near the air-jet interface, ATF coverage/accumulation on the ring surface, and cooling capacity are presented for a low-resolution Reynolds averaged Navier-Stokes (RANS), high-resolution RANS, and high-resolution Large-Eddy Simulation (LES) models. Computations are scaled over hundreds of cores on a supercomputer to maximize turnaround time. Each numerical approach is shown to capture the general trajectory of the oil jet prior to surface impingement. The high-resolution LES simulation, however, is superior in capturing small scale details and heat transfer between the free jet and surrounding air.

42 ENGINEERING↗

Low Particulates Nitrogen Purge and Backfill During Prototype HB650 Cryomodule String Assembly

A low particulate vacuum and purging system was developed to support PIP-II cryomodule string assembly. The overpressure can be controlled at a precision of 1 mbar above the atmospheric pressure regardless of the cavity or string assembly air volume. The system minimized the risk of uncontrolled nitrogen flow during the string assembly. Design features are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantification of trace iodine using laser-induced breakdown spectroscopy for real-time monitoring of nuclear off-gas streams

This study evaluated the potential of laser-induced breakdown spectroscopy (LIBS) for real-time monitoring of trace gas-phase iodine, which is an element of high significance in nuclear applications due to its long radioactive half-life (as iodine-129), volatility, and biological impact. In anticipation of iodine evolving into off-gas systems in molten salt reactor and nuclear fuel recycling applications, this research aimed to assess LIBS performance in flowing argon and helium matrices; optimize measurement parameters using a multichannel spectrometer; and perform calibrations to assess predictive capabilities and limits of detection (LODs). Experimental results successfully measured gas-phase iodine in flowing argon and helium; however, trace iodine was not detected in air. Optimal delay times were determined to be 10 µs for argon and 1 µs for helium, which are consistent with the expected shorter plasma lifetime in helium relative to argon. An emission line survey was provided with the 206.16, 804.37, 902.24, and 905.83 nm peaks, which were identified as the strongest emission peaks. Calibration models were successfully built in both helium and argon, achieving LODs down to 3 ppm in helium and 5 ppm in argon. The iodine emission at 905.83 nm emerged as the most robust for calibration and was subsequently applied to a time series dataset in argon. The predictive trace confirmed the feasibility of employing LIBS for continuous, online quantification of trace iodine in flowing gas systems.

Andrews, Hunter B. [Oak Ridge National Laboratory ↗

Evolution of Idealized Vortices in Monsoon-Like Shears: Application to Monsoon Depressions

Abstract This study examines processes fundamental to the development of South Asian monsoon depressions using an array of integrations of an idealized convection-permitting numerical model. In each integration, a wave of initially small amplitude is subjected to a different amount of vertical and meridional wind shear, with temperature and moisture fields constructed according to realistic constraints. Based on the evolution of this disturbance into monsoon depression–like vortices, two features of the background environment emerge as important: the low-level gradient of moist static energy (MSE) and the low-level meridional shear. As the low-level MSE gradient steepens, the disturbance becomes stronger and produces more rain. This strengthening results from the interaction of the vortex with latent heat release by convection that is in turn organized by positive MSE advection in the northerly flow west of the vortex. In this region of advection, moister air from the north ascends along upward-sloping isentropes, driving moist convection. The disturbance also becomes stronger with increasing meridional shear, which makes the environment more barotropically unstable. The absence of either of these two features of the background environment prevents substantial growth of the disturbance. Our results suggest that monsoon depression growth in South Asia is fostered by the coexistence of a strong low-level MSE gradient with strong meridional wind shear associated with the monsoon trough.

54 ENVIRONMENTAL SCIENCES↗

ORGANIC RANKINE CYCLE TURBINE AND HEAT EXCHANGER SIZING FOR LIQUID AIR COMBINED CYCLE

Cryogenic energy storage offers several opportunities to design turbomachinery and other equipment for novel cycles. This paper presents the design and analysis of turbomachinery and heat exchangers for an Organic Rankine Cycle (ORC) subsystem for a hybrid energy storage concept. The Liquid Air Combined Cycle is an energy storage system that stores air at cryogenic conditions at times with high variable renewable energy to be dispatched along with a gas turbine to recover the exhaust heat. In order to re-vaporize the air, the liquid air is coupled with an ORC as an additional bottoming cycle. The ORC turbine is expected to expand the fluid with a pressure ratio of nearly 30 and a flow rate of approximately 45 kg/s. Sizing calculations for both a radial and axial turbine solution were performed over a range of speeds and stages to determine the optimal design point. The results show that either an axial (8- or 9-stage) or radial (four stages at two shaft speeds) turbine are capable of handling the pressure ratios. Further trades of the two configurations would be required to determine the best option. The ORC system also incorporates five heat exchangers to distribute heat, vaporize the liquid air, or recover exhaust heat from the gas turbine. Three heat exchangers were analyzed to understand the size of heat exchangers and pressure drop for the overall system. Different types of heat exchangers were explored for the different purposes, including plate-fin heat exchangers, gasketed plate heat exchangers and shell-in-tube heat exchangers. It was determined that the ORC recuperator, liquid-air vaporizer, and vaporized air pre-heater would be counter-flow heat exchangers using a gasketed plate design. Keywords: Energy Storage, Liquid Air Energy Storage, Organic Rankine Cycle

Pryor, Owen↗

Computational Fluid Dynamics Modeling of Low Temperature Ignition Processes From a Nanosecond Pulsed Discharge at Quiescent Conditions

Recent interest in nonequilibrium plasma discharges as sources of ignition for the automotive industry has not yet been accompanied by the availability of dedicated models to perform this task in computational fluid dynamics (CFD) engine simulations. The need for a low-temperature plasma (LTP) ignition model has motivated much work in simulating these discharges from first principles. Most ignition models assume that an equilibrium plasma comprises the bulk of discharge kernels. LTP discharges, however, exhibit highly nonequilibrium behavior. In this work, a method to determine a consistent initialization of LTP discharge kernels for use in engine CFD codes like CONVERGE is proposed. The method utilizes first principles discharge simulations. Such an LTP kernel is introduced in a flammable mixture of air and fuel, and the subsequent plasma expansion and ignition simulation is carried out using a reacting flow solver with detailed chemistry. Finally, the proposed numerical approach is shown to produce results that agree with experimental observations regarding the ignitability of methane-air and ethylene-air mixtures by LTP discharges.

33 ADVANCED PROPULSION SYSTEMS↗