Search NASA⌕ Search

SEARCH · Search NASA

Results for “APERTURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

A New Type of X-ray Condenser Lenses with Large Apertures Fabricated by Rolling of Structured Films

In order to meet the demand for X-ray lenses with large apertures and, hence, photon flux, a new type of X-ray lenses has been developed: Rolled prismatic X-ray lenses feature a vast number of refracting surfaces to increase transparency and aperture, respectively. Prototypes of such lenses have been fabricated by molding and rolling of a structured polyimide film. In this work, rolled prismatic X-ray lenses are pictured, and results of first tests performed at the ANKA storage ring in Karlsruhe are presented.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of beam limiting aperture and collector potential on multi-element focused ion beams

A compact microwave driven plasma based multi-element focused ion beam system has been developed. In the present work, the effect of reduced beam limiter (BL) aperture on the focused ion beam parameters, such as current and spot size, and a method of controlling beam energy independently by introducing a biased collector at focal point (FP) are investigated. It is found that the location of FP does not change due to the reduction of BL aperture. The location of FP and beam size are found to be weakly dependent on the collector potential in the range from -8 kV to -18 kV.

43 PARTICLE ACCELERATORS↗

Coded aperture imaging of fusion source in a plasma focus operated with pure D{sub 2} and a D{sub 2}-Kr gas admixture

The coded aperture imaging (CAI) technique has been used to investigate the spatial distribution of DD fusion in a 1.6 kJ plasma focus (PF) device operated in, alternatively, pure deuterium or deuterium-krypton admixture. The coded mask pattern is based on a singer cyclic difference set with 25% open fraction and positioned close to 90 Degree-Sign to the plasma focus axis, with CR-39 detectors used to register tracks of protons from the D(d, p)T reaction. Comparing the coded aperture imaging proton images for pure D{sub 2} and D{sub 2}-Kr admixture operation reveals clear differences in size, density, and shape between the fusion sources for these two cases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma electron source for the generation of wide-aperture pulsed beam at forevacuum pressures

This article reports on design and application of wide-aperture pulsed beam source, based on hollow cathode discharge. The source is intended for electron beam generation in pressure range 2-15 Pa. Multi-aperture extraction system, used in a source, provided beam cross-section uniformity of 10% on diameter 40 mm. The limiting values of the current density, pulse duration, and accelerating voltage are 350 mA/cm{sup 2}, 250 {mu}s, and 10 kV, respectively. These parameters are sufficient for surface modification of various materials, including non-conducting matters.

43 PARTICLE ACCELERATORS↗

Slanted annular aperture arrays as enhanced-transmission metamaterials: Excitation of the plasmonic transverse electromagnetic guided mode

We present here the fabrication and the optical characterization of slanted annular aperture arrays engraved into silver film. An experimental enhanced transmission based on the excitation of the cutoff-less plasmonic guided mode of the nano-waveguides (the transmission electron microscopy mode) is demonstrated and agrees well with the theoretical predicted results. By the way, even if it is less efficient (70% → 20%), an enhanced transmission can occur at larger wavelength value (720 nm–930 nm) compared to conventional annular aperture arrays structure by correctly setting the metal thickness.

36 MATERIALS SCIENCE↗

Design of large aperture superferric quadrupole magnets for an in-flight fragment separator

Superferric quadrupole magnets to be used for in-flight fragment separator have been designed. A quadrupole magnet triplet for beam focusing is placed in a cryostat together with superconducting correction coils. To maximize acceptance of rare isotope beams produced by projectile fragmentation, it is essential to use large-aperture quadrupole magnets. The pole tip radius is 17 cm in the current design, and we tried to enlarge the aperture with 3D analysis on magnetic fields. In the front end of the separator, where a target and beam dump are located, we plan to use two sets of quadrupole triplets made of high-Tc superconductor (HTS) operating at 20-50 K considering high radiation heat load. The HTS magnet will use warm iron poles. Both low-Tc and high-Tc superconductors are acquired for test winding, and two kinds of dewar and cryostat are under construction to perform the coil and magnet tests. The magnetic design of superferric quadrupole is mainly discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nonlinear optical characterization of graphite oxide thin film by open aperture Z-scan technique

In this paper we explore the structural characterization of graphite oxide powder prepared from graphite powder by oxidation via modified Hummers method. The nonlinear optical properties of the spin coated graphite oxide thin film is also explored by open aperture Z-Scan technique. Structural and physiochemical properties of the samples were investigated with the help of Fourier Transform Infrared Spectroscopy (FTIR) and Raman Spectroscopy (Raman).The results of FT-IR and Raman spectroscopy showed that the graphite is oxidized by strong oxidants and the oxygen atoms are introduced into the graphite layers forming C=C, O-H and –C-H groups. The synthesized sample has good crystalline nature with lesser defects. The nonlinear optical property of GO thin film was studied by open aperture Z-Scan technique using Q-switched Nd-Yag Laser at 532 nm. The Z-scan plot showed that the investigated GO thin film has saturable absorption behavior. The nonlinear absorption coefficient and saturation intensity were also estimated to explore its applications in Q switched mode locking laser systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Digital autofocusing of a coded-aperture Laue diffraction microscope

To provide optimal depth resolution with a coded-aperture Laue diffraction microscope, an accurate position of the coded-aperture and its scanning geometry need to be known. However, finding the geometry by trial and error is a time-consuming and often challenging process because of the large number of parameters involved. In this paper, we propose an optimization approach to automate the focusing process after data is collected. Here we demonstrate the robustness and efficiency of the proposed approach with experimental data taken at a synchrotron facility.

47 OTHER INSTRUMENTATION↗

Fibre Fabry - Perot cavity-based aperture probe for near-field optical microscopy systems

We report a theoretical analysis and experimental study of the possibility of producing a novel type of interferometric near-field aperture probe for near-field optical microscopy systems using a fibre Fabry - Perot microcavity with a nanometre-scale aperture made in one of its output mirrors. The probe ensures a spatial resolution no worse than {lambda}/14. (fibre optics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Localised plasmons on the aperture of a channel in a metal layer

Optical fields are studied in a planar channel inside a metal layer taking into account a complex dielectric function of the metal. An influence of an exit aperture on the incident field propagating along the channel is considered; a mathematical approach is developed for analysing the effect. Attention is paid to the fact that the incident field should not be assumed a priori known if the wave transformation at the exit is neglected. For a chosen dimension of the channel and parameters of a metal, the coefficients for the lowest mode transformation into higher modes are found. The spatial field structure at the exit aperture and on the exit surface of a metal is studied. Existence of domains possessing an anomalously high intensity is revealed. (electromagnetic fields)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Vertical-cavity surface-emitting lasers with intracavity contacts and a rhomboidal current aperture for compact atomic clocks

Single-mode vertical-cavity surface-emitting lasers (VCSELs) with intracavity contacts, composite distributed Bragg reflectors, and a rhomboidal selectively-oxidised current aperture are studied. It is shown that the use of a rhomboidal current aperture allows the light output polarisation to be fixed without using a special surface relief and leads to efficient narrowing of the emission line with retaining a high slope efficiency. The developed VCSELs have a high output power (exceeding 1 mW), a threshold current below 1 mA, an effective modulation frequency exceeding 5 GHz, and a linewidth smaller than 60 MHz at increased (65 – 75 °C) temperatures and are promising for application in compact Cs vapour cell atomic clocks. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

APODIZED PUPIL LYOT CORONAGRAPHS FOR ARBITRARY APERTURES. IV. REDUCED INNER WORKING ANGLE AND INCREASED ROBUSTNESS TO LOW-ORDER ABERRATIONS

The Apodized Pupil Lyot Coronagraph (APLC) is a diffraction suppression system installed in the recently deployed instruments Palomar/P1640, Gemini/GPI, and VLT/SPHERE to allow direct imaging and spectroscopy of circumstellar environments. Using a prolate apodization, the current implementations offer raw contrasts down to 10{sup –7} at 0.2 arcsec from a star over a wide bandpass (20%), in the presence of central obstruction and struts, enabling the study of young or massive gaseous planets. Observations of older or lighter companions at smaller separations would require improvements in terms of the inner working angle (IWA) and contrast, but the methods originally used for these designs were not able to fully explore the parameter space. We propose a novel approach to improve the APLC performance. Our method relies on the linear properties of the coronagraphic electric field with the apodization at any wavelength to develop numerical solutions producing coronagraphic star images with high-contrast region in broadband light. We explore the parameter space by considering different aperture geometries, contrast levels, dark-zone sizes, bandpasses, and focal plane mask sizes. We present an application of these solutions to the case of Gemini/GPI with a design delivering a 10{sup –8} raw contrast at 0.19 arcsec and offering a significantly reduced sensitivity to low-order aberrations compared to the current implementation. Optimal solutions have also been found to reach 10{sup –10} contrast in broadband light regardless of the aperture shape, with effective IWA in the 2-3.5 λ/D range, therefore making the APLC a suitable option for the future exoplanet direct imagers on the ground or in space.

79 ASTRONOMY AND ASTROPHYSICS↗

DESIGN OF PHASE INDUCED AMPLITUDE APODIZATION CORONAGRAPHS OVER SQUARE APERTURES

The purpose of this paper is to present the results of a theoretical study pertaining to the feasibility of Phase Induced Amplitude Apodization (PIAA) units using deformable mirrors (DMs). We begin by reviewing the general derivation of the design equations driving PIAA. We then show how to solve these equations for square apertures and show the performance of pure PIAA systems in the ray optics regime. We tie these design equations into the study of edge diffraction effects and provide a general expression for the field after a full propagation through a PIAA coronagraph. Third, we illustrate how a combination of pre- and post-apodizers yields a contrast of 10{sup -10} even in the presence of diffractive effects, for configuration with neither wavefront errors or wavefront control. Finally, we present novel PIAA configurations over square apertures which circumvent the constraints on the manufacturing of PIAA optics by inducing the apodization with two square DMs. Such solutions rely on pupil size smaller than currently envisioned static PIAA solutions and thus require aggressive pre- and post-apodizing screens in order to mitigate for diffractive effect between the two mirrors. As a result they are associated with significant loss in performance, throughput in particular.

79 ASTRONOMY AND ASTROPHYSICS↗

Spatial mode dynamics in wide-aperture quantum-dot lasers

We present a systematic theoretical study of spatial mode dynamics in wide-aperture semiconductor quantum-dot lasers within the Maxwell-Bloch formalism. Our opto-electro-thermal model self-consistently captures the essential dynamical coupling between field, polarization, and carrier density in both thermal and nonthermal regimes, providing detailed description of the complex spatiotemporal modal intensity structure and spectra in these novel devices and broad area edge-emitting lasers in general. Using linear stability analysis and high resolution adaptive-grid finite element numerical simulation, we show that in the nonthermal regime, the presence of inhomogeneous broadening in quantum-dot active media leads to suppressed filamentation and enhanced spatial coherence compared to conventional quantum well devices with comparable phase-amplitude coupling (alpha parameter). Increasing the degree of inhomogeneous broadening in the active medium leads to further improvement in spatial coherence. In the thermal regime, there is further suppression of filamentation in the inhomogeneously broadened quantum-dot active medium; however, the spatial coherence aided by inhomogeneous broadening is partly lost due to the effect of temperature on cavity detuning. We propose that device designs based on optimized inhomogeneous broadening of quantum-dot gain medium could ultimately lead to diffraction-limited outputs in the quasi-cw regime which are still very difficult to achieve in conventional wide-aperture designs.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Improved far-field optical trap for cold atoms (molecules) with phase-modulated circular aperture diffraction

We propose a scheme to trap cold atoms (or molecules) by using an improved red- or blue-detuned far-field optical trap, which is formed by an optical system composed of a binary phase plate and a circular aperture illuminated by a plane light wave. We calculate the relative intensity distribution of the far-field trap and study its dependence on the phase phi of the binary phase plate. Our study shows that the binary phase plate can be used to improve some geometric and optical parameters of the far-field optical trap, and realize the evolution of the far-field optical trap from a red-detuned trap to a blue-detuned one. In particular, when the phase phi of the binary phase plate is changed from 0 to -pi, the maximum intensity of the far-field trap and its well depth will be enhanced by approx4 times, and the corresponding trapping volume will be increased by approx8 times, with respect to a trapping beam obtained from the diffraction by a circular aperture.

74 ATOMIC AND MOLECULAR PHYSICS↗

Coherent hard x-ray diffractive imaging of nonisolated objects confined by an aperture

Coherent hard x-ray imaging of nonisolated weak phase objects is demonstrated by confining x-ray beam in a region of a few micrometers in cross section using a micrometer-sized aperture. Two major obstacles in the hard x-ray coherent diffraction imaging, isolating samples and obtaining central speckles, are addressed by using the aperture. The usefulness of the proposed method is illustrated by reconstructing the exit wave field of a nanoscale trench structure fabricated on silicon which serves as a weak phase object. The quantitative phase information of the exit wave field was used to reconstruct the depth profile of the trench structure. The scanning capability of this method was also briefly discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hexagonal Uniformly Redundant Arrays (HURAs) for scintillator based coded aperture neutron imaging

A series of Monte Carlo simulations have been conducted, making use of the EJ-426 neutron scintillator detector, to investigate the potential of using hexagonal uniformly redundant arrays (HURAs) for scintillator based coded aperture neutron imaging. This type of scintillator material has a low sensitivity to gamma rays, therefore, is of particular use in a system with a source that emits both neutrons and gamma rays. The simulations used an AmBe source, neutron images have been produced using different coded-aperture materials (boron- 10, cadmium-113 and gadolinium-157) and location error has also been estimated. In each case the neutron image clearly shows the location of the source with a relatively small location error. Neutron images with high resolution can be easily used to identify and locate nuclear materials precisely in nuclear security and nuclear decommissioning applications. (authors)

42 ENGINEERING↗

Fabrication and Analysis of 150-mm-Aperture Nb 3 Sn MQXF Coils

The U.S. LHC Accelerator Research Program (LARP) and CERN are combining efforts for the HiLumi-LHC upgrade to design and fabricate 150-mm-aperture, interaction region quadrupoles with a nominal gradient of 130 T/m using Nb 3 Sn. To successfully produce the necessary long MQXF triplets, the HiLumi-LHC collaboration is systematically reducing risk and design modification by heavily relying upon the experience gained from the successful 120-mm-aperture LARP HQ program. First generation MQXF short (MQXFS) coils were predominately a scaling up of the HQ quadrupole design allowing comparable cable expansion during Nb 3 Sn formation heat treatment and increased insulation fraction for electrical robustness. A total of 13 first generation MQXFS coils were fabricated between LARP and CERN. Systematic differences in coil size, coil alignment symmetry, and coil length contraction during heat treatment are observed and likely due to slight variances in tooling and insulation/cable systems. Analysis of coil cross sections indicate that field-shaping wedges and adjacent coil turns are systematically displaced from the nominal location and the cable is expanding less than nominally designed. Lastly, a second generation MQXF coil design seeks to correct the expansion and displacement discrepancies by increasing insulation and adding adjustable shims at the coil pole and midplanes to correct allowed magnetic field harmonics.

43 PARTICLE ACCELERATORS↗