Search NASA⌕ Search

SEARCH · Search NASA

Results for “ATMOSPHERIC HEATING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Estimation of the Surface Fluxes for Heat and Momentum in Unstable Conditions with Machine Learning and Similarity Approaches for the LAFE Data Set

Abstract Measurements of three flux towers operated during the land atmosphere feedback experiment (LAFE) are used to investigate relationships between surface fluxes and variables of the land–atmosphere system. We study these relations by means of two machine learning (ML) techniques: multilayer perceptrons (MLP) and extreme gradient boosting (XGB). We compare their flux derivation performance with Monin–Obukhov similarity theory (MOST) and a similarity relationship using the bulk Richardson number (BRN). The ML approaches outperform MOST and BRN. Best agreement with the observations is achieved for the friction velocity. For the sensible heat flux and even more so for the latent heat flux, MOST and BRN deviate from the observations while MLP and XGB yield more accurate predictions. Using MOST and BRN for latent heat flux, the root mean square errors (RMSE) are 107 Wm $$^{-2}$$ - 2 and 121 Wm $$^{-2}$$ - 2 , respectively, as well as the intercepts of the regression lines are $$\approx 110$$ ≈ 110 Wm $$^{-2}$$ - 2 . For the ML methods, the RMSEs reduce to 31 Wm $$^{-2}$$ - 2 for MLP and 33 Wm $$^{-2}$$ - 2 for XGB as well as the intercepts to just 4 Wm $$^{-2}$$ - 2 for MLP and $$-1$$ - 1 Wm $$^{-2}$$ - 2 for XGB with slopes of the regression lines close to 1, respectively. These results indicate significant deficiencies of MOST and BRN, particularly for the derivation of the latent heat flux. In fact, in contrast to the established theories, feature importance weighting demonstrates that the ML methods base their improved derivations on net radiation, the incoming and outgoing shortwave radiations, the air temperature gradient, and the available water contents, but not on the water vapor gradient. The results imply that further studies of surface fluxes and other turbulent variables with ML techniques provide great promise for deriving advanced flux parameterizations and their implementation in land–atmosphere system models.

54 ENVIRONMENTAL SCIENCES↗

The root-zone soil moisture spectrum in a mediterranean ecosystem

Storage of water within soil pores of the root zone introduce memory effects in the dynamics of soil moisture that are considerably longer than the integral timescale of many atmospheric processes. Thus, hydro-climatic states can be “sustained” through land-surface heat and water vapor fluxes primarily because they can “feed off” on this long-term soil moisture memory. Root-zone soil moisture memory is only but one feature characterizing the spectrum of soil moisture dynamics, which is analyzed here using a combination of long-term measurements and models. In particular, the spectrum of root-zone soil moisture content in a Mediterranean ecosystem is examined using 14-years of half-hourly measurements. A distinguishing hydro-climatic feature in such ecosystems is that sources (mainly rainfall) and sinks (mainly evapotranspiration) of soil moisture are roughly out of phase with each other. For over 4 decades of time scales and 7 decades of energy, the canonical shape of the measured soil moisture spectrum is shown to be approximately Lorentzian determined by the soil moisture variance and its memory but with two exceptions: the occurrences of a peak at diurnal-to-daily time scales and a weaker peak at near annual time scales. Model calculations and spectral analysis demonstrate that diurnal and seasonal variations in hydroclimate forcing responsible for variability in evapotranspiration had minor impact on the normalized shape of the soil moisture spectrum. However, their impact was captured by adjustments in the temporal variance. These findings indicate that precipitation and not evapotranspiration variability dominates the multi-scaling properties of soil moisture variability consistent with prior climate model simulations. Furthermore, the soil moisture memory inferred by the annual peak of soil moisture (340 d) is consistent with climate model simulations, while the memory evaluated from the loss function of a linearized mass balance approach leads to a smaller value (50 d), highlighting the effect of weak non-stationarity on soil moisture variability.

54 ENVIRONMENTAL SCIENCES↗

Nighttime electric power generation at a density of 50 mW/m 2 via radiative cooling of a photovoltaic cell

A large fraction of the world's population lacks access to the electric grid. Standard photovoltaic (PV) cells can provide a renewable off-grid source of electricity but only produce power from daytime solar irradiance and do not produce power at night. While there have been several theoretical proposals and experimental demonstrations of energy harvesting from the radiative cooling of a PV cell at night, the achieved power density is very low. Here, we construct a device, which incorporates a thermoelectric generator that harvests electricity from the temperature difference between the PV cell and the ambient surrounding. We achieve 50 mW/m 2 nighttime power generation with a clear night sky, with an open-circuit voltage of 100 mV, which is orders of magnitude higher as compared with previous demonstrations. During the daytime, the thermoelectric generator also provides additional power on top of the electric power generated directly from the PV cells. Our system can be used as a continuous renewable power source for both day- and nighttime in off-grid locations.

14 SOLAR ENERGY↗

Evaluation of Atmospheric Conditions Leading to a Fumigation Event

During the afternoon of 30 January 2022, the Savannah River Site experienced unusual temperature conditions leading to a fumigation event that triggered safety alarms and caused considerable confusion about the cause of the event. Normally, it is assumed that fumigation events occur early in the day once surface heating has begun. While most fumigation events are related to the breakup of a nocturnal inversion, this event was related to synoptic atmospheric conditions, which provided a more unique scenario that led to the fumigation event. The unusual synoptic atmospheric conditions led to the downwash and fumigation of the elevated plume, causing a pollutant to mix rapidly to the surface. These conditions could have potentially harmed workers within the facility, since the plume was directed toward a building air intake system. Here, we seek to outline the conditions that led to this unusual fumigation event and provide results of two-dimensional (2D) wind modeling of the event to characterize these conditions for future operational guidance of the facility air intake systems. This work sets the groundwork for future high-resolution modeling to explore the mechanisms and thresholds affecting fumigation on the facility-specific short distance scales and improve forecasting of non-standard fumigation events to protect human health.

54 ENVIRONMENTAL SCIENCES↗

Utah FORGE: EGS Reservoir Produced Fluids Geochemistry 2022-2024

This dataset contains geochemical analyses of produced fluids from the Utah FORGE site, specifically from wells 16A(78)-32, 16B(78)-32, and 58-32, collected during various stimulation, flowback, and circulation tests conducted between 2022 and 2024. The data contains element concentrations, pH, and dissolved gas compositions. Geochemical analyses for 2022 and 2023 were performed at the Brigham Young University geochemistry laboratory, while the 2024 results were obtained from Thermochem. Dry gas samples were collected using a mini-separator attached to the single-phase production line between the wellhead and separator, where fluid was flashed to atmospheric pressure. Gas concentrations were recalculated to a single phase reservoir liquid based on heat and mass balance expressions. Additional contextual information, including interpretations of geochemical trends and reservoir behavior, is available in the included report from Simmons et al. (2025), which was presented at the Stanford Geothermal Workshop in February 2025.

15 GEOTHERMAL ENERGY↗

Dielectric Resonator Design for Low Power and Low Temperature Microwave Plasma

Waveguide-based microwave plasmas generally operate at high temperatures (2000 - 6000K)[1], making it difficult to directly interface solid materials with the plasma without significant thermal damage. Dielectric microwave resonators (DMRs), long studied for wave-based manipulation of electromagnetic radiation for telecom and optics, can focus radiation to extremely small mode volumes, creating intense localized fields with low-power input.[2] This phenomenon can be used for applications ranging from efficient plasma electronics to near-ambient plasma-materials interactions. Such DMR-based plasmas have been demonstrated a handful of times in the literature, but the majority of research towards this utilize the lowest frequency resonance mode.[3], [4], [5] By carefully controlling the geometry of cylindrical resonators, a variety of electromagnetic modes can be excited. In this work, COMSOL Multiphysics simulations are used to study the electric field enhancement and absorption properties of CaTiO3 DMRs as a function of geometry and excitation frequency. Whereas previous studies have utilized the HEM111 resonance frequency to drive low power plasma excitation, we find that higher order resonance frequencies are more effective at field enhancement and result in less power loss within the dielectric material, hence less wasted heating. The effectiveness of these modes is also geometry dependent and can be computationally optimized for plasma generation. Complementing these computational efforts, we demonstrate a new closed-system reactor design built in a WR-650 waveguide and experimentally demonstrate the formation of atmospheric argon microwave plasma using < 30 W input power on DMR dimers. We observe a shifting resonance frequency as the DMRs heat in response to microwave excitation and develop a Python-based lock-in mechanism to effectively track the DMR resonance over time, leading to stable plasma operation. We use infrared thermal imaging to monitor the temperature of the DMR dimers and surrounding quartz chamber, demonstrating thermal temperatures < 60 degreesC. Finally, we utilize optical emission spectroscopy (OES) to probe the plasma properties as a function of the resonance mode.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Eddy Correlation Flux Measurement System (ECOR) Instrument Handbook

The eddy correlation (ECOR) flux measurement system provides in situ, half-hour measurements of the surface turbulent fluxes of momentum, sensible heat, latent heat, and carbon dioxide (CO 2 ) (and methane at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility’s North Slope of Alaska central facility [NSA Barrow], and at the ARM Mobile Facility (AMF) deployment at Oliktok Point). The fluxes are obtained with the eddy covariance technique, which involves correlation of the vertical wind component with the horizontal wind component, the air temperature, the water vapor density, and the CO 2 concentration. The instruments used are: a fast-response, three-dimensional (3D) wind sensor (sonic anemometer) to obtain the orthogonal wind components and the speed of sound (SOS) (used to derive the air temperature), an open-path infrared gas analyzer (IRGA) to obtain the water vapor density and the CO 2 concentration, and an open-path infrared gas analyzer (IRGA) to obtain methane density and methane flux at NSA Barrow and at the AMF deployment at Oliktok Point. The ECOR systems are deployed at the locations where other methods for surface flux measurements (e.g., energy balance Bowen ratio [EBBR] systems) are difficult to employ, primarily at the north edge of a field of crops. A surface energy balance system (SEBS) has been installed collocated with each deployed ECOR system in SGP, NSA, Tropical Western Pacific (TWP), and each of three ARM Mobile Facilities. The surface energy balance system consists of upwelling and downwelling solar and infrared radiometers within one net radiometer, a wetness sensor, and soil measurements. Finally, the SEBS measurements allow the comparison of ECOR sensible and latent heat fluxes with the energy balance determined from the SEBS and provide information on wetting of the sensors for data quality purposes.

47 OTHER INSTRUMENTATION↗

Investigation of Thermal-Hydraulic Effects of Dry Storage Canister Helium Backfill Loss Using the Horizontal Dry Cask Simulator

A previous investigation produced data sets that can be used to benchmark the codes and best practices presently used to determine cladding temperatures and induced cooling air flows in modern horizontal dry storage systems. The horizontal dry cask simulator (HDCS) was designed to generate this benchmark data and add to the existing knowledge base. The objective of the previous HDCS investigation was to capture the dominant physics of a commercial dry storage system in a well-characterized test apparatus for a wide range of operational parameters. The close coupling between the thermal response of the canister system and the resulting induced cooling air flow rate was of particular importance. The previous investigation explored these parameters using helium backfill at 100 kPa and 800 kPa pressure as well as air backfill with a series of simulated decay heats. The helium tests simulated a horizontal dry cask storage system at normal storage conditions with either atmospheric or elevated backfill pressure, while the air tests simulated horizontal storage canisters following a complete loss of helium backfill, in which case the helium would be replaced by air. The present HDCS investigation adds to the previous investigation by exploring steady-state conditions at various stages of the loss of helium backfill from a horizontal dry cask storage system. This is achieved by using helium/air blends as a backfill in the HDCS and running a series of tests using various simulated decay heats to explore the effects of relative helium/air molar concentration on the thermal response of a simulated horizontal dry cask storage system. A total of twenty tests were conducted where the HDCS achieved steady state for various assembly powers, representative of decay heat. The power levels tested were 0.50, 1.00, 2.50, and 5.00 kW. All tests were run at 100 kPa vessel pressure. The backfill gases used in these tests are given in this report as a function of mole fraction of helium (He), balanced by air: 1.0, 0.9, 0.5, 0.1, and 0.0 He. Steady-state conditions (where the steady-state start condition is defined as where the change in temperature with respect to time for the majority of HDCS components is less than or equal to 0.3 K/h) were achieved for all test cases.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Strong Coulomb coupling influences ion and neutral temperatures in atmospheric pressure plasmas

Molecular dynamics simulations are used to model ion and neutral temperature evolution in partially-ionized atmospheric pressure plasma at different ionization fractions. Results show that ion–ion interactions are strongly coupled at ionization fractions as low as 10 –5 and that the temperature evolution is influenced by effects associated with the strong coupling. Specifically, disorder-induced heating is found to rapidly heat ions on a timescale of the ion plasma period (~10 s ps) after an ionization pulse. This is followed by the collisional relaxation of ions and neutrals, which cools ions and heats neutrals on a longer (~ns) timescale. Slight heating then occurs over a much longer (~100 s ns) timescale due to ion-neutral three-body recombination. An analytic model of the temperature evolution is developed that agrees with the simulation results. Finally, a conclusion is that strong coupling effects are important in atmospheric pressure plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Image Characterization of Reactions Generated by an Aeroengine Micromixing Injector for Lean Direct Injection of Hydrogen and Hydrogen/Natural Gas Blend

An aeroengine micromixing injector, originally designed for lean direct injection of jet fuel, was adapted to work with hydrogen, natural gas, and any blend in between. The ultimate goal of the design was to achieve low NOx emissions when operated on pure hydrogen; to better characterize its performance, flame imaging diagnostics was implemented. Three types of cameras mounted parallel to the injector base and pointing towards the quartz combustor cylinder with the same angle were operated simultaneously: Nikon D90, Dynacolor FB-N9-U, and Phantom v7.1, to capture the visible spectrum, OH* chemiluminescence, and dynamic behavior of the flames, respectively. The current work also includes the overlapping of visible spectrum and OH* chemiluminescence, as an effort to qualitatively define the heat release over the flame area, i.e., UV over visible domain. Additionally, a z-type schlieren configuration was employed to reinforce the presence of some small-scale details occurring near the injector outlet ports. Using the airbox pressure drop, preheat temperature, fuel composition and flame temperature as the factors of study, a Box Behnken model was designed yielding into a 16-points matrix for the operability region, at atmospheric pressure. The main responses were extracted from the OH* images, because of its correlation with the flame heat release, these being the flame area and its average brightness, the heat release area and its center of gravity and leading edge. To assess the importance of the main factors and their interactions, an analysis of variance (ANOVA) was performed for each response, considering as significant each contributor with a p-value below 0.05. For these five responses it was found that all four main factors need to be included into the model (most of them because its own significance, others to ensure the model hierarchy), as well as some common interactions as the preheat and flame temperatures or pressure drop and fuel composition, and quadratic terms from fuel composition or flame temperature. Three of the five models presented R2 and coefficient of variance (C.V.) indicators around 0.97 and 5%, respectively; the leading edge ANOVA yielded into R2=0.78 and C.V.=18.88%; and the heat release area showed R2=0.91 and C.V.=24.13%. Lastly, the confinement ratio effect of the combustor over the flame structure was quantified, for three different conditions: the original 80 mm inner diameter and 200 mm length cylinder was compared against a shorter 150 mm tube (same inner diameter) and a narrower 47 mm inner diameter one (same 200 mm length). The length had a smaller effect than the inner diameter, even though both factors were not strong enough to make a significant deviation on most of the flame parameters: the difference was within the repeatability margin of error for the brightness, flame area, and center of gravity and leading edge of the heat release area.

Imaging diagnostics, flame characterization, OH* c↗

What is the long-term demand for liquid hydrocarbon fuels and feedstocks?

Liquid hydrocarbons made from crude oil serve many functions: (1) a dense, easy-to-store, easy-to-transport energy source, (2) a method for daily-to-seasonal energy storage, (3) a chemical feedstock, (4) a chemical reducing agent and (5) a method to enhance high-temperature heat transfer in many furnaces and industrial processes. Liquid hydrocarbons can be produced and used without increasing atmospheric carbon dioxide levels if made from non-fossil feedstocks such as carbon dioxide or biomass. Understanding future liquid hydrocarbon demand is the starting point in assessing the viability of such options. Our assessment is that U.S. demand for liquid hydrocarbons is unlikely to go below the equivalent of 10 million barrels per day of crude oil but could be as high as 20 million barrels per day. The costs to replace liquid hydrocarbons increases rapidly at lower liquid hydrocarbon consumption rates. Hydrocarbon biofuels from cellulosic feedstocks can meet such demands if produced with large external inputs of heat and hydrogen. Options based on more limited feedstocks (starches, plant oils, sugars, etc.) can’t meet such demands.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Subtropical Eastern North Pacific SST bias in earth system models

Karthik Balaguru (PNNL), Luke Van Roekel (LLNL), L. Ruby Leung (PNNL) and Milena Veneziani (LLNL) Abstract: This study systematically evaluates the warm SST bias in the Subtropical Eastern North Pacific (SENP), a problem plaguing most CMIP6 models, using the Energy Exascale Earth System Model version 1 (E3SM). Compared to the model at its standard resolution (1o atmosphere, 30-60 km ocean), the SST bias improves in several regions at high resolution (0.25o atmosphere, 18-6 km ocean) except in subtropical eastern boundary regions, such as the SENP. A mixed layer heat budget analysis reveals that errors in the surface radiative fluxes and horizontal heat advection are primarily responsible for the bias. Analysis of HighResMIP models indicates that the lack of improvement in the SENP SST bias with resolution is not native to E3SM alone. A larger CMIP6 inter-model correlation of SST bias with biases in surface winds than radiation highlights the important role of large-scale circulation biases in the SENP SST bias in coupled models.

Balaguru, Karthik↗

Merging flux-variance with surface renewal methods in the roughness sublayer and the atmospheric surface layer

In this article, Two micrometeorological methods utilizing high-frequency sampled air temperature were tested against eddy covariance (EC) sensible heat flux (𝐻) measurements at three sites representing agricultural, agro-forestry, and forestry systems. The two methods cover conventional and newly proposed forms of the flux-variance (FV) and surface renewal (SR) schemes of differing complexities. The sites represent measurements in surface, roughness, and roughness to surface transitional layers. Regression analyzes against EC show that the most reliable FV and SR forms estimate 𝐻 with slopes within ±10% from unity and coefficient of determination 𝑅2 > 0.9 across all the three sites. The best performance of both FV and SR was found at the agricultural site with measurements well within the surface layer, while the worst was found for the tall forest with measurements within the roughness sublayer where its thickness needed to be additionally estimated. The main variable driving 𝐻 in FV is the temperature variance, whereas in SR, it is the geometry of ramp-like structures. Since these structures are also responsible for most of the temperature variance, a novel FV-SR approach emerging from combining the methods is proposed and evaluated against EC measurements and conventional FV and SR schemes. The proposed FV-SR approach requiring only a single fast response thermocouple is potentially independent of calibration and ameliorates some of the theoretical objections that arise when combining ramp statistics with similarity arguments. The combination of methods also provides new insights into the contribution of coherent structures to the temperature variance and its dependence on atmospheric stratification. Other potential utility of the new method is to include it in multi-tool assessments of surface energy fluxes, since a convergence or divergence of the results has a high diagnostic value.

54 ENVIRONMENTAL SCIENCES↗

An experimental and chemical kinetic modeling study of 4-butoxyheptane combustion

Here, the combustion kinetics of a novel oxygenated bioblendstock for diesel, 4-butoxyheptane (4-BH), was investigated experimentally using a flow reactor and a heated, high-pressure shock tube. The flow reactor experiments employed oxygen as the oxidizer and helium as the diluent with oxidation conducted at atmospheric pressure and 10 bar for temperatures from 400 to 1000 K at 20-K intervals. The fuel, oxidizer, and diluent flow rates were varied at different temperatures to maintain a constant initial fuel mole fraction of 1000 ppm, with stoichiometric equivalence ratio, and a residence time of 2.0 s. The reacted gas was fed to two separate GC systems that could qualitatively and quantitatively detect product species. Additionally, real fuel-air ignition delay time (IDT) data were collected using a heated, high-pressure shock-tube facility. Fuel lean (φ = 0.5) and stoichiometric (φ = 1.0) mixtures were investigated at 10 atm as well as at 30 atm for the fuel lean case for temperatures between 847 and 1259 K. A detailed chemical kinetics mechanism was developed to model the product distribution from the flow reactor and IDTs from the shock tube. The proposed model was able to predict the double NTC behavior in flow reactor experiments reasonably well. Model predictions at low temperatures were observed to be highly sensitive to the rate constants of ketohydroperoxide (KHP) decomposition in the case of the OOH group in α position which were modeled based on existing literature studies on ethers. It was noted that in the absence of theoretical or experimental studies, the rate constants for KHP decomposition used in the literature were empirically set. Additional studies are required to address the gap in model prediction obtained in this study and to reduce the uncertainty in kinetics models for ether oxidation. Predicted product concentrations and IDTs showed some quantitative agreement with experimental data, but the overall reactivity of the IDTs is underpredicted. Additionally, significant deviation is observed for the IDT results at 10 atm for the stoichiometric case with minor deviations for the other cases. The reaction pathways to the missing products were then further analyzed theoretically through quantum-mechanical calculations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The De-Icing Comparison Experiment (D-ICE): a study of broadband radiometric measurements under icing conditions in the Arctic

Abstract. Surface-based measurements of broadband shortwave (solar) and longwave (infrared) radiative fluxes using thermopile radiometers are made regularly around the globe for scientific and operational environmental monitoring. The occurrence of ice on sensor windows in cold environments – whether snow, rime, or frost – is a common problem that is difficult to prevent as well as difficult to correct in post-processing. The Baseline Surface Radiation Network (BSRN) community recognizes radiometer icing as a major outstanding measurement uncertainty. Towards constraining this uncertainty, the De-Icing Comparison Experiment (D-ICE) was carried out at the NOAA Atmospheric Baseline Observatory in Utqiaġvik (formerly Barrow), Alaska, from August 2017 to July 2018. The purpose of D-ICE was to evaluate existing ventilation and heating technologies developed to mitigate radiometer icing. D-ICE consisted of 20 pyranometers and 5 pyrgeometers operating in various ventilator housings alongside operational systems that are part of NOAA's Barrow BSRN station and the US Department of Energy Atmospheric Radiation Measurement (ARM) program North Slope of Alaska and Oliktok Point observatories. To detect icing, radiometers were monitored continuously using cameras, with a total of more than 1 million images of radiometer domes archived. Ventilator and ventilator–heater performance overall was skillful with the average of the systems mitigating ice formation 77 % (many >90 %) of the time during which icing conditions were present. Ventilators without heating elements were also effective and capable of providing heat through roughly equal contributions of waste energy from the ventilator fan and adiabatic heating downstream of the fan. This provided ∼0.6 ∘C of warming, enough to subsaturate the air up to a relative humidity (with respect to ice) of ∼105 %. Because the mitigation technologies performed well, a near complete record of verified ice-free radiometric fluxes was assembled for the duration of the campaign. This well-characterized data set is suitable for model evaluation, in particular for the Year of Polar Prediction (YOPP) first Special Observing Period (SOP1). We used the data set to calculate short- and long-term biases in iced sensors, finding that biases can be up to +60 W m−2 (longwave) and −211 to +188 W m−2 (shortwave). However, because of the frequency of icing, mitigation of ice by ventilators, cloud conditions, and the timing of icing relative to available sunlight, the biases in the monthly means were generally less than the aggregate uncertainty attributed to other conventional sources in both the shortwave and longwave.

54 ENVIRONMENTAL SCIENCES↗

Unraveling the Pyrolytic Behavior and Kinetics of Single Polymers and Plastic-Rich Municipal Solid Waste Using Thermal Analysis

Pyrolysis is a highly promising thermochemical recycling technology for converting heterogenous plastic waste into sustainable fuels in a single step. Therefore, understanding the pyrolysis mechanism is essential for enabling rational reactor design and enhancing efficient recycling techniques. In this study, the thermal degradation behaviors and corresponding kinetics of pure polymers (PE, PP, and PET) and plastic-rich MSW were examined using simultaneous thermogravimetric analysis (TGA) and differential scanning calorimetry (DSC). Experiments were carried out in the temperature range of 30-800°C with variable heating rates from 5°C/min to 20°C/min in an ultra-high purity Argon atmosphere. Our results indicated that the plastic pyrolysis was an endothermic process, with varying decomposition temperature ranges depending on their structure and composition. Various iso-conversional model-free methods (Friedman, Flynn-Wall-Ozawa, Starink, and Kissinger-Akahira-Sunose) were utilized to determine the apparent activation energy of the plastic degradation, which increased in the following order: PET (214 kJ/mol), PP (218 kJ/mol), PE (245 kJ/mol), and MSW (249 kJ/mol). Finally, Criado’s master plots were employed to identify the best-fitting reaction model and the pre-exponential factor was subsequently determined.

Bashir, Muhammad Aamir↗

Numerical Investigation of the characteristics of pressurized biomass-oxy-combustion

As a second generation of oxy-fuel combustion technologies, pressurized oxy-combustion has a potential to improve the process efficiency and economy. With the modern decarbonization needs, biomass combustion is considered to be nearly CO2 neutral, and thus co-firing biomass with coal in an oxy-combustion process can achieve a negative CO2 balance. The size of the biomass fuel particles is a key parameter in an entrained flow combustor because large biomass particles, exceeding some threshold size, may only partially be burnt due to the restrictions on the heat transport, thereby diminishing the combustion efficiency. While such a threshold particle size has been scrutinized at an atmospheric pressure, the present study extends the analysis to elevated pressures. Specifically, two scenarios were set up, for experimental-scale and full-scale pressurized oxy-combustors, with the threshold sizes of biomass particles appearing 0.5 mm and 5 mm, respectively, without temperature gradient in biomass particles. With temperature gradient, the parametric study included the particles in the range from 0.15 mm to 5 mm. It is shown that the thermal-thin model is applicable to spherical biomass particles not exceeding 0.15 mm. The impact of the heating rate on biomass particle devolatilization was also investigated and the biomass devolatilization could happen in less than 1 second; the same amount of heat energy could induce different volatile release rates.

Li, Lei↗

Ultra-High Operation Temperature SiC-matrix Solar Thermal Air Receiver (HOTSSTAR) enabled by additive manufacturing: Test Facility & Performance Evaluations

Solar Heat for Industrial Processes (SHIP) cavity receivers are capable of generating electricity or industrial process heat by absorbing thermal energy from solar radiation, focused on a small area. The concentration of solar radiation on the small area of the receiver enables the achievement of high temperatures (ranging from 400°C to 1,100°C) of a working fluid, thus making the SHIP technology thermodynamically comparable with conventional power plants. A volumetric receiver consists of a porous structure-generally made of silicon carbide or metal, which absorbs solar radiation and converts it into heat energy. Heat energy from the porous materials is then transferred to the fluid following through them. A volumetric receiver acts as a convective heat exchanger, transferring heat to the fluid through convection. Open-loop volumetric receivers work with air at atmospheric pressure and are suitable for single-cycle or multi-cycle energy plants. A Model Based Systems Engineering (MBSE) approach was used to develop a test bed at Sandia national Laboratories (SNL) capable of demonstrating an open-loop volumetric air receiver developed by General Electric Aerospace (GE Aerospace). This paper presents the development of the various MBSE methods, test bed, and testing operations for the GE air receiver, which was experimentally demonstrated to achieve 1,350°C for over 3 hours of operation and an approximate 70% receiver efficiency. By being able to achieve such high temperatures >1,000°C, this work provides the potential to support many SHIP industrial use cases.

14 SOLAR ENERGY↗