Search NASA⌕ Search

SEARCH · Search NASA

Results for “Absolute pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Lines of Fe XII sensitive to coronal electron density

Lines of Fe XII sensitive to coronal electron density are discussed. The lines appear in solar spectra obtained by the Naval Research Laboratory (NRL) slit spectograph flown on Skylab. These lines are due to transitions between levels of the 3s 2 3p 3 configuration and fall at the wavelengths 1242.03 A, 1349.38 A, 2169.03 A, 2405.71 A, and 2565.99 A. It is shown that the line at 2169.03 A is severely blended by a line of Ni II at heights less than 12 arcsec outside the solar limb. Above 12 arcsec the lines at 2169.03 and 2405.71 A are apparently unblended and can be used to derive electron densities. An average coronal electron pressure of 6 x 10 to the 14th/cu cm K is obtained. However, the emitting path lengths of the Fe XII lines, deduced using the electron densities and absolute intensities, are unrealistically large. The reason for this difficulty is unclear.

Feldman, U.↗

Tunable diode laser measurements of formaldehyde foreign-gas broadening parameters and line strengths in the 9-11-micron region

A tunable diode laser spectrometer has been used to determine pressure broadening coefficients due to collision with the foreign gases air, H2, O2, and N2 in the nu4 and nu6 bands of H2CO between 9 and 11 microns. Absolute line strengths for twenty-eight transitions have also been determined. The broadening coefficients are very similar to theoretical literature values in the cases of air, N2, and O2. The H2-H2CO values are in good agreement with earlier experimental millimeter-wave results.

Nadler, Shachar↗

CN radical reactions with hydrogen cyanide and cyanogen - Comparison of theory and experiment

The method of laser photolysis/laser-induced fluorescence is used to obtain absolute rate constants for CN radical reactions with HCN and C2N2. The rate constants were found to be temperature-dependent in the range 300-740 K and pressure independent in the range 100-600 Torr. Rice-Remsperger-Kassel-Marcus theory for both reactions employing the transition state parameters obtained by the BAC-MP4 method are made. These calculations yielded reasonable results for the CN + HCN reaction, predicting both the temperature dependence and pressure independence. No pressure effect was observed in the pressure range 100-1000 Torr at temperatures below 900 K, confirming the experimental results.

Yang, D. L.↗

Mesospheric and Upper Stratospheric Temperatures From OMPS-LP

We report the development of a temperature profile data set from the Ozone Mapping and Profiler Suite Limb Profiler (OMPS-LP) instrument on the Suomi NPP satellite. The data set covers a roughly 10 year period from 2012 to 2022, and temperatures are provided in the altitude range between 35 and 70 km. The algorithm uses daytime Rayleigh scattered radiation near 350 nm to estimate atmospheric density profiles, which are vertically integrated using the hydrostatic equation to estimate atmospheric pressure. Temperature profiles are then derived using the ideal gas law. Spectral structures in the OMPS-LP radiances are a source of systematic errors that limit the absolute accuracy to ±2 K. However, since the systematic errors do not change significantly over time, the relative accuracy is better than ±1 K. Our temperature data set has been designed to supplement global temperature maps produced by assimilation of data from traditional meteorological sensors, including GNSS radio occultation sensors, that provide high quality atmospheric temperature profiles up to 40–55 km. We show comparisons to other co-located temperature datasets to validate our product.

Observations of Mesospheric and Upper Stratospheri↗

Absolute rate constant of the reaction OH + HO2 yields H2O + O2

The absolute rate constant of the reaction OH + HO2 yields H2O + O2 was determined by using the discharge-flow resonance fluorescence technique at 299 K and 1-torr total pressure. Pseudo-first-order conditions were used with HO2 concentrations in large excess over OH. Secondary reactions of atomic oxygen and atomic hydrogen were shown not to interfere under the conditions used. The result is (6.4 plus or minus 1.5) x 10 to the -11th cu cm/molecule s where the error limits are twice the standard deviation. The overall experimental error is estimated to be plus or minus 30%.

Keyser, L. F.↗

FTIR Spectroscopy of HNO3 and NO2 Relevant to Stratospheric Wake Analysis

The Fourier Transform Infrared (FTIR) technique has been employed to measure absolute concentrations of nitric acid (HNO3) and nitrogen dioxide (NO2) with 1/cm resolution and an absorption pathlength of 4 m under quasi-static and flow conditions at atmospheric pressure and room temperature. Water features seen under quasi-static conditions diminished in intensity under flowing conditions. Nitric acid was observed in the 1660-1760/cm range, while nitrogen dioxide was detected both in the 1536-1660 and 1213-1400/cm ranges. Concentrations of nitrogen dioxide and nitric acid were determined to be 11.9 and 4.35 parts per million (ppm), respectively, with an uncertainty of 0.2 ppm. Experiments are underway with a 10 m cell to measure the absorption of nitric acid, water, sulfur dioxide, hydrochloric acid and ammonia on various materials such as glass, teflon, stainless steel and aluminum used for implementation of the flow system. Such materials will be used for the measurements of stratospheric trace gases by the Quartz Crystal Microbalance (QCM) and Surface Acoustic Wave (SAW) devices.

Abina, Rafiu A.↗

Effects of Mean Flow Profiles on Instability of a Low-Density Gas Jet Injected into a High-Density Gas

The objective of this study was to investigate the effects of the mean flow profiles on the instability characteristics in the near-injector region of low-density gas jets injected into high-density ambient gas mediums. To achieve this, a linear temporal stability analysis and a spatio-temporal stability analysis of a low-density round gas jet injected vertically upwards into a high-density ambient gas were performed by assuming three different sets of mean velocity and density profiles. The flow was assumed to be isothermal and locally parallel. Viscous and diffusive effects were ignored. The mean flow parameters were represented as the sum of the mean value and a small normal-mode fluctuation. A second order differential equation governing the pressure disturbance amplitude was derived from the basic conservation equations. The first set of mean velocity and density profiles assumed were those used by Monkewitz and Sohn for investigating absolute instability in hot jets. The second set of velocity and density profiles assumed for this study were the ones used by Lawson. And the third set of mean profiles included a parabolic velocity profile and a hyperbolic tangent density profile. The effects of the inhomogeneous shear layer and the Froude number (signifying the effects of gravity) on the temporal and spatio-temporal results for each set of mean profiles were delineated. Additional information is included in the original extended abstract.

Vedantam, Nanda Kishore↗

Thermophysical Properties of Cold and Vacuum Plasma Sprayed Cu-Cr-X Alloys, NiAl and NiCrAlY Coatings: Specific Heat Capacity - Part 2

Part I of the paper discussed the temperature dependencies of the electrical resistivities, thermal conductivities, thermal diffusivities and total hemispherical emissivities of several vacuum plasma sprayed (VPS) and cold sprayed copper alloy monolithic coatings, VPS NiAl, VPS NiCrAlY, extruded GRCop-84 and as-cast Cu-17(wt.%)Cr-5%Al. Part II discusses the temperature dependencies of the constant pressure specific heat capacities, CP, of these coatings. The data were empirically were regression-fitted with the equation: CP = AT4 + BT3 + CT2 + DT +E where T is the absolute temperature and A, B, C, D and E are regression constants. The temperature dependencies of the molar enthalpy, molar entropy and Gibbs molar free energy determined from experimental values of molar specific heat capacity are reported. Calculated values of CP using the Neumann-Kopp (NK) rule were in poor agreement with experimental data. Instead, a modification of the Neumann-Kopp rule was found to predict values closer to the experimental data with an absolute deviation less than 6.5%. The specific molar heat capacities for all the alloys did not agree with the Dulong-Petit law, and CP is greater than 3R, where R is the universal gas constant, were measured for all the alloys except NiAl for which CP is less than 3R at all temperatures.

Raj, S. V.↗

High resolution absorption coefficients for Freon-12

The ultra high resolution absorption coefficients of the Q-branch of Freon-12 obtained with tunable diode laser spectroscopy are presented. Continuous spectra are presented from 1155/cm to 1163/cm, and absolute wavelength calibration was obtained using SO2 spectra as a standard and a 5 cm Ge etalon for relative calibration between SO2 lines. The Freon-12 data obtained at a pressure of 0.05 torr showed a rich and highly structured spectra, but with the exception of three isolated features, collisional broadening reduces the spectra to a structureless continuum for nitrogen pressures greater than 20 torr. The spectra at 1161/cm continue to exhibit structure at atmospheric pressure.

Hoell, J. M.↗

Anomalous /C-13/H4:/C-12/H4 line strengths in 2 nu 3

Anomalous intensity ratios between 2 nu 3 singlet lines of C-13 methane and C-12 methane are reported. Absolute strengths of the Q1, R0 and R1 singlets were measured for essentially pure samples of (C-13)H4 and (C-12)H4 at a resolution of 0.035 kaysers at pressures of 10 and 20 Torr, using a computer controlled grating spectrometer. Line strength ratios between the isotopic species are presented which demonstrate a dramatic effect of isotopic substitution on line strengths. If this effect can be observed in the 3 nu 3 vibration-rotation band of methane, which is widely used in planetary atmosphere studies, revision of the (C-12)H4/(C-13)H4 abundance ratios of the outer planets will be necessary.

Fox, K.↗

A Kinetic and Product Study of the Cl + HO2 Reaction

Absolute rate data and product branching ratios for the reactions Cl + HO2 to HCl + O2 (k1a) and Cl + HO2 to OH + ClO (k1b) have been measured from 226 to 336 K at a total pressure of 1 Torr of helium using the discharge flow resonance fluorescence technique coupled with infrared diode laser spectroscopy. For kinetic measurements, pseudo-first-order conditions were used with both reagents in excess in separate experiments. HO2 was produced by two methods: through the termolecular reaction of H atoms with O2 and also by the reaction of F atoms with H2O2. Cl atoms were produced by a microwave discharge of Cl2 in He. HO2 radicals were converted to OH radicals prior to detection by resonance fluorescence at 308 nm. Cl atoms were detected directly at 138 nm also by resonance fluorescence. Measurement of the consumption of HO2 in excess Cl yielded k1a and measurement of the consumption of Cl in excess HO2 yielded the total rate coefficient, k1. Values of k1a and k1 derived from kinetic experiments expressed in Arrhenius form are (1.6 +/- 0.2) x 10-11 exp[(249 +/- 34)/T] and (2.8 +/- 0.1) x 10-11 exp[(123 +/- 15)/T] cm3 molecule-1 s-1, respectively. As the expression for k1 is only weakly temperature dependent, we report a temperature-independent value of k1 = (4.5 +/- 0.4) x 10-11 cm3 molecule-1 s-1. Additionally, an Arrhenius expression for k1b can also be derived: k1b = (7.7 +/- 0.8) x 10-11 exp[-(708 +/- 29)/T] cm3 molecule-1 s-1. These expressions for k1a and k1b are valid for 226 K T 336 and 256 K T 296 K, respectively. The cited errors are at the level of a single standard deviation. For the product measurements, an excess of Cl was added to known concentrations of HO2 and the reaction was allowed to reach completion. HCl product concentrations were determined by IR absorption yielding the ratio k1a/k1 over the temperature range 236 K T 296 K. OH product concentrations were determined by resonance fluorescence giving rise to the ratio k1b/k1 over the temperature range 226 K T 336 K. Both of these ratios were subsequently converted to absolute numbers. Values of k1a and k1b from the product experiments expressed in Arrhenius form are (1.5 +/- 0.1) x 10-11 exp[(222 +/- 17)/T] and (10.6 +/- 1.5) x 10-11 exp[-(733 +/- 41)/T] cm3 molecule-1 s-1, respectively. These expressions for k1a and k1b are valid for 256 K T 296 and 226 K T 336 K, respectively. A combination of the kinetic and product data results in the following Arrhenius expressions for k1a and k1b of (1.4 +/- 0.3) x 10-11 exp[(269 +/- 58)/T] and (12.7 +/- 4.1) x 10-11 exp[-(801 +/- 94)/T] cm3 molecule-1 s-1, respectively. Numerical simulations were used to check for interferences from secondary chemistry in both the kinetic and product experiments and also to quantify the losses incurred during the conversion process HO2 to OH for detection purposes.

rate constants↗

Ultraviolet atomic emission detector

A device and method are provided for performing qualitative and quantitative elemental analysis through the utilization of a vacuum UV chromatographic detector. The method involves the use of a carrier gas at low pressure. The gas carries a sample to a gas chromatograph column; the column output is directed to a microwave cavity. In this cavity, a low pressure microwave discharge produces fragmentation of the compounds present and generates intense atomic emissions in the vacuum ultraviolet. These emissions are isolated by a monochromator and measured by photometer to establish absolute concentration for the elements.

Braun, W.↗

Equilibration temperatures in enstatite chondrites

Equilibration temperatures for enstatite chondrites are calculated using a method suggested by Larimer (1968). The temperatures range from 640 to 840 C. The method yields temperatures which, in principle, are correct on a relative scale, but the absolute error may be as large as 150 C. There is a good correlation between the calculated temperatures and petrologic type as well as other mineralogic characteristics and bulk composition. Partial pressures of sulfur and oxygen at the time of equilibration ranged from about 10 to the minus 8th to 10 to the minus 12th atm and from about 10 to the minus 28th to 10 to the minus 37th atm, respectively.

Larimer, J. W.↗

Scaling of the beam plasma discharge for low magnetic fields

A theoretical analysis of the scaling law and the value of the threshold current for beam plasma discharge (BPD) is presented, based on the requirement for an absolute instability near the plasma frequency. It is shown that both the scaling law as well as the numerical values of Ic are consistent with the experimental data, in the low pressure regimes and for weak magnetic field experiments if the dominant particle loss mechanism is due to Bohm diffusion. The implications of the findings to electron injection in space are discussed.

Papadopoulos, K.↗

Insulation Test Cryostat with Lift Mechanism

A multi-purpose, cylindrical thermal insulation test apparatus is used for testing insulation materials and systems of materials using a liquid boil-off calorimeter system for absolute measurement of the effective thermal conductivity (k-value) and heat flux of a specimen material at a fixed environmental condition (cold-side temperature, warm-side temperature, vacuum pressure level, and residual gas composition). The apparatus includes an inner vessel for receiving a liquid with a normal boiling point below ambient temperature, such as liquid nitrogen, enclosed within a vacuum chamber. A cold mass assembly, including the upper and lower guard chambers and a middle test vessel, is suspended from a lid of the vacuum canister. Each of the three chambers is filled and vented through a single feedthrough. All fluid and instrumentation feedthroughs are mounted and suspended from a top domed lid to allow easy removal of the cold mass. A lift mechanism allows manipulation of the cold mass assembly and insulation test article.

Fesmire, James E.↗

Insulation Test Cryostat with Lift Mechanism

A multi-purpose, cylindrical thermal insulation test apparatus is used for testing insulation materials and systems of materials using a liquid boil-off calorimeter system for absolute measurement of the effective thermal conductivity (k-value) and heat flux of a specimen material at a fixed environmental condition (cold-side temperature, warm-side temperature, vacuum pressure level, and residual gas composition). An inner vessel receives liquid with a normal boiling point below ambient temperature, such as liquid nitrogen, enclosed within a vacuum chamber. A cold mass assembly, including upper and lower guard chambers and middle test vessel, is suspended from a lid of the vacuum canister. Each of the three chambers is filled and vented through a single feedthrough. All fluid and instrumentation feedthroughs are mounted and suspended from a top domed lid allowing easy removal of the cold mass. A lift mechanism allows manipulation of the cold mass assembly and insulation test article.

Fesmire, James E.↗

Absolute Position of Targets Measured Through a Chamber Window Using Lidar Metrology Systems

Lidar is a useful tool for taking metrology measurements without the need for physical contact with the parts under test. Lidar instruments are aimed at a target using azimuth and elevation stages, then focus a beam of coherent, frequency modulated laser energy onto the target, such as the surface of a mechanical structure. Energy from the reflected beam is mixed with an optical reference signal that travels in a fiber path internal to the instrument, and the range to the target is calculated based on the difference in the frequency of the returned and reference signals. In cases when the parts are in extreme environments, additional steps need to be taken to separate the operator and lidar from that environment. A model has been developed that accurately reduces the lidar data to an absolute position and accounts for the three media in the testbed air, fused silica, and vacuum but the approach can be adapted for any environment or material. The accuracy of laser metrology measurements depends upon knowing the parameters of the media through which the measurement beam travels. Under normal conditions, this means knowledge of the temperature, pressure, and humidity of the air in the measurement volume. In the past, chamber windows have been used to separate the measuring device from the extreme environment within the chamber and still permit optical measurement, but, so far, only relative changes have been diagnosed. The ability to make accurate measurements through a window presents a challenge as there are a number of factors to consider. In the case of the lidar, the window will increase the time-of-flight of the laser beam causing a ranging error, and refract the direction of the beam causing angular positioning errors. In addition, differences in pressure, temperature, and humidity on each side of the window will cause slight atmospheric index changes and induce deformation and a refractive index gradient within the window. Also, since the window is a dispersive media, the effect of both phase and group indices have to be considered. Taking all these factors into account, a method was developed to measure targets through multiple regions of different materials and produce results that are absolute measurements of target position in three-dimensional space, rather than simply relative position. The environment in which the lidar measurements are taken must be broken down into separate regions of interest and each region solved for separately. In this case, there were three regions of interest: air, fused silica, and vacuum. The angular position of the target inside the chamber is solved using only phase index and phase velocity, while the ranging effects due to travel from air to glass to vacuum/air are solved with group index and group velocity. When all parameters are solved simultaneously, an absolute knowledge of the position of each target within an environmental chamber can be derived. Novel features of this innovation include measuring absolute position of targets through multiple dispersive and non-dispersive media, deconstruction of lidar raw data from a commercial off-the-shelf unit into reworkable parameters, and use of group velocities to reduce range data. Measurement of structures within a vacuum chamber or other harsh environment, such as a furnace, may now be measured as easily as if they were in an ambient laboratory. This analysis permits transformation of the raw data into absolute spatial units (e.g., mm). This technique has also been extended to laser tracker, theodolite, and cathetometer measurements through refractive media.

Kubalak, David↗

Evidence-Based Approach to the Analysis of Serious Decompression Sickness with Application to EVA Astronauts

It is important to understand the risk of serious hypobaric decompression sickness (DCS) in order to develop procedures and treatment responses to mitigate the risk. Since it is not ethical to conduct prospective tests about serious DCS with humans, the necessary information was gathered from 73 published reports. We hypothesize that a 4-hr 100% oxygen (O2) prebreathe results in a very low risk of serious DCS, and test this through analysis. We evaluated 258 tests containing information from 79,366 exposures in attitude chambers. Serious DCS was documented in 918 men during the tests. Serious DCS are signs and symptoms broadly classified as Type II DCS. A risk function analysis with maximum likelihood optimization was performed to identify significant explanatory variables, and to create a predictive model for the probability of serious DCS [P(serious DCS)]. Useful variables were Tissue Ratio, the planned time spent at altitude (T(sub alt)), and whether or not repetitive exercise was performed at altitude. Tissue Ratio is P1N2/P2, where P1N2 is calculated nitrogen (N2) pressure in a compartment with a 180-min half-time for N2 pressure just before ascent, and P2 is ambient pressure after ascent. A prebreathe and decompression profile Shuttle astronauts use for extravehicular activity (EVA) includes a 4-hr prebreathe with 100% O2, an ascent to P2 = 4.3 lb per sq. in. absolute, and a T(sub alt) = 6 hr. The P(serious DCS) is: 0.0014 (0.00096 - 0.00196, 95% confidence interval) with exercise and 0.00025 (0.00016 - 0.00035) without exercise. Given 100 Shuttle EVAs to date and no report of serious DCS, the true risk is less than 0.03 with 95% confidence (Binomial Theorem). It is problematic to estimate the risk of serious DCS since it appears infrequently, even if the estimate is based on thousands of altitude chamber exposures. The true risk to astronauts may lie between the extremes of the confidence intervals (0.00016 - 0.00196) since the contribution of other factors, particularly exercise, to the risk of serious DCS during EVA is unknown. A simple model that only accounts for four important variables in retrospective data is still helpful to increase our understanding about the risk of serious DCS.

Conkin, Johnny↗