Characterization of BNL and HPK AC-LGAD sensors with a 120 GeV proton beam

We present measurements of AC-LGADs performed at the Fermilab's test beam facility using 120 GeV protons. Here we studied the performance of various strip and pad AC-LGAD sensors that were produced by BNL and HPK. The measurements are performed with our upgraded test beam setup that utilizes a high precision telescope tracker, and a simultaneous readout of up to 7 channels per sensor, which allows detailed studies of signal sharing characteristics. These measurements allow us to assess the differences in designs between different manufacturers, and optimize them based on experimental performance. We then study several reconstruction algorithms to optimize position and time resolutions that utilize the signal sharing properties of each sensor. We present a world's first demonstration of silicon sensors in a test beam that simultaneously achieve better than 6–10 μm position and 30 ps time resolution. This represents a substantial improvement to the spatial resolution than would be obtained with binary readout of sensors with similar pitch.

47 OTHER INSTRUMENTATION↗

PHOTOMETRIC CONSTRAINTS ON THE REDSHIFT OF z {approx} 10 CANDIDATE UDFj-39546284 FROM DEEPER WFC3/IR+ACS+IRAC OBSERVATIONS OVER THE HUDF

Ultra-deep WFC3/IR observations on the HUDF from the HUDF09 program revealed just one plausible z {approx} 10 candidate, UDFj-39546284. UDFj-39546284 had all the properties expected of a galaxy at z {approx} 10 showing (1) no detection in the deep ACS+WFC3 imaging data blueward of the F160W band, exhibiting (2) a blue spectral slope redward of the break, and showing (3) no prominent detection in deep IRAC observations. The new, similarly deep WFC3/IR HUDF12 F160W observations over the HUDF09/XDF allow us to further assess this candidate. These observations show that this candidate, previously only detected at {approx}5.9{sigma} in a single band, clearly corresponds to a real source. It is detected at {approx}5.3{sigma} in the new H{sub 160}-band data and at {approx}7.8{sigma} in the full 85-orbit H{sub 160}-band stack. Interestingly, the non-detection of the source (<1{sigma}) in the new F140W observations suggests a higher redshift. Formally, the best-fit redshift of the source utilizing all the WFC3+ACS (and IRAC+K{sub s} -band) observations is 11.8 {+-} 0.3. However, we consider the z {approx} 12 interpretation somewhat unlikely, since the source would either need to be {approx}20 Multiplication-Sign more luminous than expected or show very high-EW Ly{alpha} emission (which seems improbable given the extensive neutral gas prevalent early in the reionization epoch). Lower-redshift solutions fail if only continuum models are allowed. Plausible lower-redshift solutions require that the H{sub 160}-band flux be dominated by line emission such as H{alpha} or [O III] with extreme EWs. The tentative detection of line emission at 1.6 {mu}m in UDFj-39546284 in a companion paper suggests that such emission may have already been found.

79 ASTRONOMY AND ASTROPHYSICS↗

Calculation of transition probabilities and ac Stark shifts in two-photon laser transitions of antiprotonic helium

Numerical ab initio variational calculations of the transition probabilities and ac Stark shifts in two-photon transitions of antiprotonic helium atoms driven by two counter-propagating laser beams are presented. We found that sub-Doppler spectroscopy is, in principle, possible by exciting transitions of the type (n,L){yields}(n-2,L-2) between antiprotonic states of principal and angular momentum quantum numbers n{approx}L-1{approx}35, first by using highly monochromatic, nanosecond laser beams of intensities 10{sup 4}-10{sup 5} W/cm{sup 2}, and then by tuning the virtual intermediate state close (e.g., within 10-20 GHz) to the real state (n-1,L-1) to enhance the nonlinear transition probability. We expect that ac Stark shifts of a few MHz or more will become an important source of systematic error at fractional precisions of better than a few parts in 10{sup 9}. These shifts can, in principle, be minimized and even canceled by selecting an optimum combination of laser intensities and frequencies. We simulated the resonance profiles of some two-photon transitions in the regions n=30-40 of the p{sup 4}He{sup +} and p{sup 3}He{sup +} isotopes to find the best conditions that would allow this.

74 ATOMIC AND MOLECULAR PHYSICS↗

Relation between ac Josephson effect and double-well Bose-Einstein-condensate oscillations

In this article we comment on the relation between the ac Josephson effect and the coherent oscillations of a Bose-Einstein condensate confined to a double-well potential. The goal is to elucidate the extent to which the latter is a realization of the former. We detail the correspondence between the two oscillation frequencies, that emerges in the high occupation limit of the double-well potential. We show that in the latter thermodynamic limit the effective one-particle interwell coupling vanishes with the system size, leading to oscillation frequency that depends only on the interwell imbalance, consistent with the ac Josephson effect frequency.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ac Stark gradient echo memory in cold atoms

The burgeoning fields of quantum computing and quantum key distribution have created a demand for a quantum memory. The gradient echo memory scheme is a quantum memory candidate for light storage that can boast efficiencies approaching unity, as well as the flexibility to work with either two- or three-level atoms. The key to this scheme is the frequency gradient that is placed across the memory. Currently, the three-level implementation uses a Zeeman gradient and warm atoms. In this article we model an alternate gradient-creation mechanism--the ac Stark effect--to provide an improvement in the flexibility of gradient-creation and field-switching times. We propose this scheme in concert with a move to cold atoms ({approx_equal}1 mK). These temperatures would increase the storage times possible, and the small ensemble volumes would enable large ac Stark shifts with reasonable laser power. We find that memory bandwidths on the order of MHz can be produced with experimentally achievable laser powers and trapping volumes, with high precision in gradient creation and switching times on the order of nanoseconds possible. By looking at the different decoherence mechanisms present in this system, we determine that coherence times on the order of tens of milliseconds are possible, as are delay-bandwidth products of approximately 50 and efficiencies over 90%.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Constructive and destructive interferences of Stark resonances induced by an ac field in atomic hydrogen

We study theoretically the problem of a hydrogen atom exposed both to a static dc field and to a monochromatic ac field. We show that, in the presence of an ac field, a constructive (or destructive) interference occurs between the excited (Rydberg) Stark resonance states and the hydrogenic ground state. This mechanism is responsible for dramatic enhancement (or suppression) of the corresponding photoionization rates.

74 ATOMIC AND MOLECULAR PHYSICS↗

ac Dynamics of Ferroelectric Domains from an Investigation of the Frequency Dependence of Hysteresis Loops

We investigated nonequilibrium domain wall dynamics under an ac field by measuring the hystere- sis loops of epitaxial ferroelectric capacitors at various frequencies and temperatures. Polarization switching is induced mostly by thermally activated creep motion at lower frequencies, and by vis- cous ow motion at higher frequencies. The dynamic crossover between the creep and ow regimes unveils two frequency-dependent scaling regions of hysteresis loops. Based on these findings, we constructed a dynamic phase diagram for hysteretic ferroelectric domain dynamics in the presence of ac fields.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Interaction-induced long-time tail of a nonlinear ac absorption in a localized system: A relay-race mechanism

In conventional solid-state electron systems with localized states the ac absorption is linear since the inelastic widths of the energy levels exceed the drive amplitude. The situation is different in the systems of cold atoms in which phonons are absent. Then even a weak drive leads to saturation of the ac absorption within resonant pairs, so that the population of levels oscillates with the Rabi frequency. We demonstrate that, in the presence of weak dipole-dipole interactions, the response of the system acquires a long-time component which oscillates with frequency much smaller than the Rabi frequency. The underlying mechanism of this long-time behavior is that the fields created in the course of the Rabi oscillations serve as resonant drive for the second-generation Rabi oscillations in pairs with level spacings close to the Rabi frequency. Here, the frequency of the second-generation oscillations is of the order of interaction strength. As these oscillations develop, they can initiate the next-generation Rabi oscillations, and so on. Formation of the second-generation oscillations is facilitated by the nondiagonal component of the dipole-dipole interaction tensor.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Regulation of Dynamical Systems to Optimal Solutions of Semidefinite Programs: Algorithms and Applications to AC Optimal Power Flow

This paper considers a collection of networked nonlinear dynamical systems, and addresses the synthesis of feedback controllers that seek optimal operating points corresponding to the solution of pertinent network-wide optimization problems. Particular emphasis is placed on the solution of semidefinite programs (SDPs). The design of the feedback controller is grounded on a dual e-subgradient approach, with the dual iterates utilized to dynamically update the dynamical-system reference signals. Global convergence is guaranteed for diminishing stepsize rules, even when the reference inputs are updated at a faster rate than the dynamical-system settling time. The application of the proposed framework to the control of power-electronic inverters in AC distribution systems is discussed. The objective is to bridge the time-scale separation between real-time inverter control and network-wide optimization. Optimization objectives assume the form of SDP relaxations of prototypical AC optimal power flow problems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Soft Switching Over the Entire Line Cycle for a Quadruple Active Bridge DCX in a DC to Three-Phase AC Module

This paper is focused on a transformer-isolated quadruple active bridge (QAB) dc-dc converter loaded by three full-bridge dc-ac inverters. The QAB functions as a "DC trans-former" (DCX) in the dc-to-three-phase ac module. The QAB outputs provide time-varying power at twice the line frequency, which presents challenges in maintaining zero voltage switching (ZVS) on the secondary sides during low-power portions of the line cycle. It is shown how ZVS can be achieved in a phase, even at zero-power transfer, using a relatively small circulating current provided by the magnetizing inductance of the high-frequency transformer. The approach is particularly effective in high-voltage applications using SiC MOSFETs, where reductions in switching loss outweigh additional conduction losses due to the circulating currents. A detailed analysis of ZVS switching waveforms at the zero power transfer is presented, including effects of nonlinear device capacitances. Analytical expressions are given for the optimal values of the magnetizing inductance and dead times of the QAB primary and secondary bridges. The approach is verified by experimental results on a 600 V, 4 kW prototype, demonstrating greater than 98.5% efficiency from 1 kW to 4 kW, with a peak efficiency of 99.0%. Compared to conventionally operated prototype, a 54% reduction in total loss is achieved at rated power.

41 EE - Solar Energy Technologies Office (EE-4S)↗

A Novel Three-Phase Oak Ridge AC / DC Converter for Wireless EV Charger Applications

In this paper, a novel three-phase converter is proposed for ac to dc wireless power transfer (WPT) systems for electric vehicle (EV) charging applications. The proposed innovative solution, called as Oak Ridge Converter, reduces the design complexity and cost by eliminating the front-end converter stage compared to the conventional systems. Additionally, grid side requirements can be met with the proposed creative concept. In this concept, the three-phase single-stage Oak Ridge Converter directly converts the 60 Hz grid frequency into high-frequency voltage and utilizes hybrid grid-source and high-frequency to realize power transfer from AC source through resonant network and coupling coils to the battery load. Simulation validation of the proposed three-phase system is currently being carried on and the results will be will be provided to validate the theoretical studies with the input of 277 VAC,RMS and output of 675 VDC at 35 kW power. The system current total harmonic distortion (THD) is measured 5% with a power factor (PF) of 0.98 and overall hardware development of the system that will be used for experiments is presented.

Asa, Erdem↗

Design and Demonstration of an 850 V dc to 13.8 kV ac 100 kW Three-phase Four-wire Power Conditioning System Converter Using 10 kV SiC MOSFETs

In this paper, an 850 V dc to 13.8 kV ac 100 kW modular multilevel three-phase four-wire dc/ac converter based on 10 kV SiC MOSFETs is designed and demonstrated. The design considerations of key components, including the dc-link, device cooling, gate driver, isolated gate driver power supply (GDPS), medium voltage (MV) ac filter inductor, MV and medium frequency transformer, and the mechanical design are discussed. Two converters are designed, and two prototypes are developed, to study the converter paralleling operation and scalability. Both converters are fully tested up to their voltage and power ratings. However, the two converters are not identical. Based on the design and test results of the first converter, the MV power stage, transformer design, GDPS, as well as the low voltage power stage in the second converter are improved for smaller size and/or higher efficiency. Compared to the version 1 converter, the version 2 converter achieves 49% volume reduction and 2 percentage point efficiency improvement, with a peak efficiency of 98.4% at the rated power.

Li, Haiguo↗

A 1MHz Oak Ridge AC / DC Converter for UAV Contactless Charger Implementation

In this paper, a 1 MHz single-phase Oak Ridge Converter (ORC) AC/DC wireless power transfer (WPT) system is introduced for unmanned air vehicle (UAV) charging applications. The proposed advanced solution eliminates the design, weight, volume, and the cost of the power factor correcting (PFC) front-end rectifier compared to the conventional practices. Additionally, grid power quality requirements can be achieved with the presented innovative idea. With this method, single stage WPT primary side uses the hybrid grid frequency and high frequency (60 Hz and 1 MHZ) from ac source through the coupler coils and to UAV battery with GaN FETs. Experimental results of the single-phase system is presented to confirm the mathematical analyses with the source voltage of 110 VAC, RMS and output voltage of 40 VDC at 1 kW power with 6 inches air gap between couplers. The primary coupler consists of a ferrite-backed single-turn coil with a radius of 1.5 ft, and the secondary coupler is made with an air-core single-turn coil with radius of 1.2 ft. The system overall ac to dc efficiency is measured 77 % acquiring 0.99 power factor (PF) and 3.3 % current total harmonic distortion (THD) at 1 kW power.

Asa, Erdem↗

Flexible Intelligent Real-time dc-ac grid Emulator (FIRE): Power Electronic Hardware-in-the-Loop (PE-HIL) Amplifier

Grid modernization efforts are leading to increased penetration of power electronics in the existing alternating current (ac) bulk power systems (BPS). Some examples of power electronics based applications that are being developed in BPS include high-voltage direct current (HVdc) systems, renewable generation systems, energy storage systems, and others. One of the requirements to succeed in the goals of grid modernization (like increased efficiency and reliability) is to setup a platform that can evaluate basic building blocks of such systems. For example, the basic building block of a modular multilevel converter (MMC)-based HVdc system is a submodule (SM). The evaluation platform will provide means to innovate new SM circuit architectures, new semiconductor devices in the SM, new gate-drivers, new controllers, and others. The flexible intelligent real-time dc-ac grid emulator (FIRE) platform incorporates the evaluation capability to evaluate the basic building blocks. The FIRE platform incorporates this evaluation capability through the power electronic hardware-in-the-loop (PE-HIL) concept. The PE-HIL for MMC-HVdc system can evaluate SMs in the MMC. In this paper, the design of amplifier required to perform PE-HIL simulation is presented. Experimental results of the amplifier and the simulation results of the PE-HIL concept utilizing the amplifier are presented.

Debnath, Suman↗

Net Load Redistribution Attacks on Nodal Voltage Magnitude Estimation in AC Distribution Networks

A high penetration level of smart devices and communication networks increases the threat of cyber-attacks in the distribution system. In this paper, we model a hidden, coordinated, net load redistribution attack (NLRA) in an AC distribution system. Based on local information of an attack region, the attacker’s goal is to create violations in nodal voltage magnitude estimation. Acting as a system operator equipped with global AC state estimation and bad data detection, we validate the stealthiness of the hidden NLRA in multiple attack cases. Simulation results on a modified PG&E 69-node distribution system show the validity of the proposed NLRA. The influence of NLRA on the distribution system is assessed and the impact of attack regions, attack timing, and system observability is also revealed.

Zhang, Hang↗

Calibrating Physical Parameters in House Models Using Aggregate AC Power Demand

For residential houses, the air conditioning (AC) units are one of the major resources that can provide significant flexibility in energy use for the purpose of demand response. To quantify the flexibility, the characteristics of all the houses need to be accurately estimated, so that certain house models can be used to predict the dynamics of the house temperatures in order to adjust the setpoints accordingly to provide demand response while maintaining the same comfort levels. In this paper, we propose an approach using the Reverse Monte Carlo modeling method and aggregate house models to calibrate the distribution parameters of the house models for a population of residential houses. Given the aggregate AC power demand for the population, the approach can successfully estimate the distribution parameters for the sensitive physical parameters based on our previous uncertainty quantification study, such as the mean of the floor areas of the houses.

Sun, Yannan↗

Experiences and Lessons from Field Demonstration of Grid-forming Inverter in An AC Microgrid

The validation of GFM control strategies through simulation and hardware demonstration is important before their large-scale deployments in the real grid. Considering the importance of testing and validation, several works have explored the GFM inverter’s capability to blackstart a microgrid, synchronize and share loads, and interact with various types of generation sources and loads present in the grid. Herein, this paper complements the existing works by presenting the results and analysis of a field demonstration in an actual AC microgrid. The capability of a three-level neutral point clamped (NPC) GFM inverter equipped with a recursive feedback type of non-linear device level control to operate with PV source on its DC input and off-the-shelf PVGFL inverters and EV chargers of different kinds on the AC side is explored. The analysis and conclusions drawn would inform the readers to make better decisions during the field demonstration process.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Comparison of Clipping Detection Techniques in AC Power Time Series

In this research, a variety of methods were developed to detect clipping periods in AC power time series. AC power data streams associated with 36 unique systems across the United States were collected, and data points representing clipping periods were manually labeled by experts. Using this data set for training and validation, novel logic-based and machine learning (ML) approaches were developed to classify time series values as clipping or non-clipping. These approaches were compared to the RdTools method for detecting clipping periods. The logic-based and ML XGBoost approaches achieved F-scores of 85.0 and 77.6, respectively, when cross-validated against the manually labeled data, as compared to the current RdTools approach (F-score of 56.4), indicating a significant improvement at detecting clipping periods. Additionally, the effects of each clipping filter when evaluating system degradation rates were assessed, using 31 unique systems across the United States. Results indicate that estimated system degradation rate can vary based on the type of clipping filter used, by up to 0.6% degradation rate for some cases.