Search NASA⌕ Search

SEARCH · Search NASA

Results for “Advanced Distribution Management System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Advanced Transmission Technologies – GETs and HPCs Session 2: Advanced Power Flow Control and Transmission Topology Optimization

The INL TADA GETs Cohort Session 2, held on November 7, 2025, conducted in collaboration with ScottMadden, focused on two core Advanced Transmission Technologies (ATTs): Advanced Power Flow Control (APFC) and Transmission Topology Optimization (TTO). These technologies are pivotal in enhancing grid flexibility, reliability, and cybersecurity resilience. APFC, particularly through modular FACTS devices like Modular Static Synchronous Series Compensators (M-SSSCs), enables dynamic voltage injection to reroute power flows. The session highlighted the deployment benefits of APFC, such as rapid installation, minimal civil works, and re-deployability. Regulatory drivers like FERC Order 2023 mandate the inclusion of Grid-Enhancing Technologies (GETs) in interconnection studies. Case studies from Central Hudson, CAISO, and National Grid (UK) demonstrated APFC’s effectiveness in congestion relief and cost savings. The session also addressed cybersecurity concerns, including firmware vulnerabilities, SCADA integration risks, and supply chain dependencies. Participants engaged in interactive exercises to rank cybersecurity and supply chain risks, emphasizing the need for robust digital assurance strategies. TTO involves software-based reconfiguration of transmission networks to optimize power flow without new infrastructure. The session showcased its operational value, with examples from SPP, PJM, and MISO showing significant congestion cost reductions. Cybersecurity vulnerabilities were discussed, particularly in API security and software supply chains, referencing incidents like SolarWinds and attacks on Danish utilities. Digital assurance exercises explored worst-case scenarios, attack paths, and mitigation responsibilities between vendors and utilities. Reliability challenges such as algorithm stability, vendor dependency, and operator trust were also examined. Cross-cutting themes emphasized the importance of digital assurance tools, including Software Bills of Materials (SBOMs) and hardware-in-loop testing. Human performance, training, and operational confidence were identified as critical enablers of technology adoption. The session concluded with a preview of Session 3, which will focus on High Performance Conductors (HPCs) and risk-based cybersecurity tools. Session 2 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Electrifying education: Exploring the electrification potential of U.S. School bus fleets

We analyze the operations of 270 diesel school buses across the United States to assess their electrification potential and evaluate the impact of various charging strategies on electricity demand. We find that school buses typically follow a two-route schedule on weekdays, featuring extended dwell times between morning and evening trips. Weekday trip distances average 25 miles, while weekend trips average 42 miles. Charging simulations indicate over 90% of the U.S. school bus fleet could be electrified using current technologies (300-mile range at 1.21 kWh/mile with 19.2-kW depot charging) without modifying existing operating patterns. Depot charging is a key enabler of school bus electrification, however, the strategic placement of charging stations at other locations (e.g., schools) can further increase electrification potential. Additionally, we find electric school bus charging to be highly flexible, with charge management capable of reducing peak charging loads at depots by up to 77%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mitigating Data Center Impact on Grid Stability: A Coordinated Control Strategy Using Verrus StabiliGrid Architecture

Large data centers, which now represent a significant and growing share of the total U.S. grid load, can inadvertently destabilize the electrical grid when they disconnect simultaneously during brief voltage disturbances. The July 10, 2024, Eastern Interconnection incident, in which a sub-100-millisecond transmission fault triggered the cascading loss of approximately 1,500 MW of data center load, illustrates this vulnerability. While commercial battery energy storage systems (BESS) deployed in data centers provide device-level fault ride-through per IEEE 1547, they lack coordination with facility protection logic and uninterruptible power supplies (UPS), limiting their effectiveness as grid-stabilizing assets. This report presents the Verrus StabiliGrid architecture, a coordinated control framework that integrates BESS, UPS, and point-of-interconnection (POI) protection settings to enable data centers to ride through both undervoltage and overvoltage grid contingencies without disconnecting. The four-step strategy encompasses: (1) high-resolution power quality monitoring to detect the grid state during events such as undervoltage, overvoltage, underfrequency, and overfrequency; (2) POI protection settings that allow for extended ride-through and grid-connected operation during grid contingencies; (3) grid state-driven autonomous dispatch of assets to improve grid resilience by reducing power draw during undervoltage or absorbing more power during overvoltage events; and (4) coordinated post-recovery dispatch of data center assets to restore firm load to pre-contingency levels. Validated through controller-hardware-in-the-loop (C-HIL) simulations at the National Laboratory of the Rockies, results show grid import restoration to pre-fault levels within 100 milliseconds of voltage recovery. This work advances the ability of data centers to transition from passive, disturbance-sensitive loads to active participants in grid stability, a capability increasingly required by emerging NERC and ERCOT regulatory frameworks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nonidealities in Rotating Detonation Engines

A rotating detonation engine (RDE) is a realization of pressure-gain combustion, wherein a traveling detonation wave confined in a chamber provides shock-based compression along with chemical heat release. Due to the high wave speeds, such devices can process high mass flow rates in small volumes, leading to compact and unconventional designs. RDEs involve unsteady and multiscale physics, and their operational characteristics are determined by an equilibrium between large- and small-scale processes. While RDEs can provide a significant theoretical gain in efficiency, achieving this improvement requires an understanding of the multiscale coupling. Specifically, unavoidable nonidealities, such as unsteady mixing, secondary combustion, and multiple competing waves associated with practical designs, need to be understood and managed. The secondary combustion processes arise from fuel/air injection and unsteady and incomplete mixing, and can create spurious losses. In addition, a combination of multiple detonation and secondary waves compete and define the dynamical behavior of mixing, heat release distribution, and the overall mode of operation of the device. This review discusses the current understanding of such nonidealities and describes the tools and techniques used to gain insight into the extreme unsteady environment in such combustors.

33 ADVANCED PROPULSION SYSTEMS↗

Future SDN-HPON Control Plane Architecture and Protocol for On-Demand Terabit End-to-End Extreme-Scale Science Applications

The UC Davis team conducted architecture, algorithm and experimental studies for next generation ultra-high-bandwidth optical networks in support of extreme-scale science applications. In particular, over the course of this 3-year project, the UC Davis team achieved the following main accomplishments: Designed a network architecture for automated multi-domain service provisioning: Designed information exchange schemes between autonomous systems (domains) Designed application programming interfaces to orchestrate resource reservation in data centers, high performance computation facilities, and communication networks belonging to different autonomous systems Experimentally assessed the multi-domain network architecture in a distributed field trial set-up connecting premises in three continents Designed a broker-based orchestrated multi-domain optical networking framework supporting observe-analyze-act cycle based cognitive inter-domain service provisioning: Designed an inter-domain operation mechanism, e.g., topology abstraction, for the broker plane and domain managers to collaboratively accomplish inter-domain service provisioning while respecting the autonomy of each administrative domain Designed an alien wavelength monitoring scheme and an artificial neural network based optical signal-to-noise ratio estimator for quality-of-transmission aware inter-domain service provisioning Developed a deep neural network based multi-domain traffic predictor and a cognitive routing and spectrum assignment algorithm to realize knowledge-based autonomous traffic engineering in multi-domain networks Implemented an optical signal-to-noise ratio estimator and traffic predictor with Google’s Tensor flow and assessed their performance using experimental and synthetic data Demonstrated the benefits of the proposed cognitive schemes with experiments ona two-domain elastic optical network testbed and evaluations on a six-domain simulation framework Built a two-domain software-defined networking control plane testbed using the ONOS platform and demonstrated the workflow of broker and domain manager cooperation, including hierarchical performance monitoring, topology abstraction and cognitive resource allocation. Designed self-learning cognitive service provisioning schemes using advanced machine learning technologies: Designed a self-taught anomaly detection framework for optical networks, including an unsupervised data clustering module for pattern recognition, a supervised data regression and classification module for online anomaly detection, and the system operation principle Experimentally validated the effectiveness of the self-taught anomaly detection framework with various failure/anomaly scenarios. Designed a self-learning autonomic routing, modulation and spectrum assignment (RMSA) provisioning framework for elastic optical networks with deep reinforcement learning. Designed effective modeling and training mechanisms for the self-learning RMSA framework Conducted extensive numerical simulations with various traffic patterns and topologies to verify the advantage of the self-learning RMSA framework.

42 ENGINEERING↗

A tool for assessing demand side management and operating strategies for isolated microgrids

Globally, power system operators are exploring ways to leverage the capabilities of smart meters to implement fine-grained demand side management (DSM). Here this paper presents a new simulation tool to evaluate operating strategies for smart-meter-enabled (SME) islanded microgrids being advanced for sustainable rural electrification in emerging economies. Based on MATLAB/Simulink, the tool's component-level models of small microgrids can be easily configured. Alternative rule-based operating strategies are implemented with controllable supply and storage components as well as other components driven by external factors (e.g., weather and time of day). To account for the wide range of possible operating conditions in real-world applications, statistical metrics can be evaluated using Monte Carlo (MC) methods based on user-defined, time-dependent probability distributions for demands, supplies, and environmental variables. Features of the tool are demonstrated with case studies for a representative microgrid in rural Rwanda.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ModuleOT: A Hardware Security Module for Operational Technology: Preprint

With increasing penetration levels of distributed energy resources (DERs) on the distribution grid, as well as new technological advancements in the cyber space, new cyberattack vectors are being introduced, and the available attack surface is constantly increasing. Despite this increasing risk, the standard IEEE 1547-2018 does not yet recommend cybersecurity measures for DERs. To address this and to better protect data on the distribution grid - from the standpoints information security as well as operational security - ModuleOT has been developed. The module aims to significantly reduce cyberattack vectors by improving data privacy for user applications. This is accomplished by performing the core functions of encryption, authentication, authorization, certificate management, and user access control. The module integrates a custom security application with hardware cryptographic acceleration. The application secures all communications using Transmission Control Protocol over Internet Protocol (TCP/IP). These include the three most commonly used communications protocols for power systems information exchange: Modbus, Distributed Network Protocol 3 (DNP3), and Smart Energy Profile 2.0 (SEP2.0). These three protocols are also supported by IEEE 1547-2018 for all DER devices. This paper tests the data encryption/decryption feature on a physical networking test bed with emulated Modbus devices reporting grid data and presents the results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impacts and emerging research opportunities in Vehicle-Grid Integration for transportation: A review

This review provides a comprehensive examination of Vehicle-Grid Integration (VGI) technologies and their impacts on transportation systems, with a particular emphasis on the transportation-energy nexus. It systematically explores how VGI affects key transportation applications such as charging infrastructure planning, electric vehicle (EV) routing, smart charging coordination, shared mobility, and dynamic pricing. By synthesizing recent literature from both transportation and energy systems perspectives, this study highlights how advanced methodologies, such as reinforcement learning, game theory, and optimization techniques, are used to model the complex interactions between EVs, mobility patterns, and distributed energy systems. Furthermore, the review also identifies critical challenges, including behavioral factors, data limitations, and system scalability. Drawing on these insights, the paper outlines emerging research opportunities to support the design of integrated, resilient, and user-centric VGI solutions that advance sustainable mobility and energy system efficiency.

Charging coordination↗

PR100: Estimated Medium- and Heavy-Duty Electric Vehicle Adoption and Load Estimation in Puerto Rico through 2050

The 2-year Puerto Rico Grid Resilience and Transition to 100% Renewable Energy Study analyzed stakeholder-driven pathways to Puerto Rico’s clean energy future. Outputs relating to electricity demand modeling were partially informed by estimates of electric vehicle adoption across all classes of medium- and heavy-duty vehicles (MHDVs), and the ensuing charging loads. To create these estimates, the team developed a transportation model for MHDVs in Puerto Rico to estimate the amount and geospatial distribution of energy used. Charging schedules for the different end uses of MHDVs were then used to construct electric load shapes assuming a portion of those vehicles would be replaced by battery electric counterparts. Study results showed that, by 2050, electric vehicles may constitute roughly 50% of the MHDV population in Puerto Rico. The resulting electrical demand curve attributable to MHDV charging showed that, for solar energy-based electrical systems with limited energy storage, this demand may create challenges unless appropriately managed either on the demand or supply side.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Adaptive Protection and Validated Models to Enable Deployment of High Penetrations of Solar PV (PV-MOD)

The availability and validation of various PV models in commercial tools differ, with some models not yet thoroughly validated for advanced inverter functionalities and reliable performance under weak system conditions. Many existing models do not fully incorporate new inverter control functions, which can affect system stability. The increasing deployment of solar PV and other inverter-based resources (IBRs), including distributed energy resources (DERs), is influencing the reliable operation of protection schemes in distribution systems and microgrids. Emerging adaptive protection schemes (APS) offer new opportunities for protecting these systems during varying configurations and DER operating conditions, though their demonstration and validation remain limited. Adaptive protection schemes face similar challenges, as they are typically designed for specific configurations. There is a growing need for tools and methodologies to streamline the deployment of adaptive protection for safe and reliable DER integration. The project main objective was to develop and validate high-fidelity generic models of solar PV facilities for stability, protection, EMT, and QSTS analyses. This objective was achieved, and these models can now be integrated into commercial software tools, enabling utilities, vendors, and developers to study high-penetration PV systems more confidently. The project also demonstrated advanced applications of these models, including the design and deployment of adaptive protection schemes in high-penetration field applications and microgrids, supporting grid safety and reliability. Several milestones were reached by the end of the project. A sophisticated inverter test plan was developed, and inverters representative of the North American marketplace were selected. EPRI and NREL tested various inverters, conforming to IEEE standards. Improvements were made to existing generic models of IBR units, IBR plants, and aggregated feeders for various analyses. The first generic electromagnetic transient (EMT) model for a solar PV plant was developed, conforming to IEEE Std 2800™-2022 and validated against laboratory measurements of a 2.2 MVA large-scale battery energy storage system (BESS) inverter. That model was then used to produce reference responses illustrating examples of validated and verified IBR plant models that pass or fail tests for technical minimum capability and performance as specified in the IEEE standard. The developed, tested, and validated generic models can be used for transmission planning, stability assessments, expansion planning, and evaluating potential future IBR interconnection requirements. They can also support interconnection screens and conformity assessments of IBR plants, including solar PV. The project significantly contributed to the ongoing standardization and model-based representation and verification of IBR responses. The project further addressed challenges of common distribution protection schemes with increasing deployment of DER by developing, validating, and demonstrating adaptive protection schemes (APS) that can improve the reliable and safe integration of DER into distribution systems. New APS were designed using improved DER models for three common distribution systems: a radial feeder, a meshed network, and a microgrid. Modeling and hardware-in-the-loop (HIL) testing of the APS were conducted, successfully showing their effectiveness and selectivity. Proof-of-concept field demonstration was achieved for two APS, i.e., one on a radial feeder and another one in a microgrid. Field demonstration could not be achieved for the APS on a meshed network, primarily due apprehension of one utility partner and also due to limited access to the protective algorithms in the network protectors. Guidelines developed from the lessons learned in the project lay out the general process followed in the design, installation, and commissioning of APS for various distribution systems. Distribution utility partners’ apprehension about field demonstration of the new APS were addressed—with varying success—by taking a stepped risk-management approach of modeling of a wide range of sensitivities first, performing in-depth proof-of-concept testing in the laboratory including HIL next, and finally deliberately implementing and commissioning the actual protection equipment and algorithms into parts of—or in parallel operation to—the three real distribution systems. Future work should include pilot projects that further show the acceptable performance of the developed APS before these schemes be rolled out more widely. Inclusion of both utility and original equipment manufacturers (OEMs) in future projects could increase chances of successful field demonstration. Despite challenges in achieving the field demonstration goal of the project for all three APS, the research significantly contributed to the innovation of adaptive protection solutions for scalable and reliable DER integration into distribution systems. This project significantly enhances the understanding of the impact of using appropriate inverter models on distribution and transmission (T&D) systems. By addressing the limitations of existing generic models, the project introduces high-fidelity models for stability, protection, electromagnetic transient (EMT), and quasi-static time series (QSTS) analyses. These models, integrated into commercial software tools, enable utilities, vendors, and developers to confidently study high-penetration PV systems. The project also demonstrates advanced applications, including adaptive protection schemes (APS) for distribution systems and microgrids, ensuring grid safety and reliability. The technical effectiveness and economic feasibility of the methods are evident through the development and validation of sophisticated inverter test plans and the selection of representative inverters. Testing by EPRI and NREL on retail, commercial, and utility-scale inverters, conforming to IEEE standards, underscores the robustness of the models. Improvements to existing generic models for various analyses further enhance their validity and applicability. The project also identifies gaps in common distribution protection schemes and designed new APS using improved DER models, demonstrating their effectiveness through modeling and hardware-in-the-loop (HIL) testing. The project’s benefits to the public are manifold. By advancing the standardization and model-based representation of IBR response, it supports transmission planning, stability assessments, and future IBR interconnection requirements. The generic models can facilitate better communication between transmission planners and developers, supporting expected IBR plant capability and performance. Additionally, the development of APS for radial feeders, meshed networks, and microgrids supports the integration of distributed energy resources (DERs) into distribution systems, enhancing grid reliability and safety. The project’s emphasis on thorough testing and simplicity in design ensures practical and scalable solutions for DER integration.

14 SOLAR ENERGY↗

Sodium Ion Expansion Power Block for Distributed CSP

The Sodium Ion Expansion Power Block for Distributed CSP was a three-plus-one-year effort under the Concentrating Solar Power: Advanced Projects Offering Low LCOE Opportunities (CSP: APOLLO) funding program within the U.S. Department of Energy Solar Energy Technologies Office. The primary objective of this project is to develop a dual-stage modular sodium thermal electrochemical converter (Na-TEC) heat engine power block, which can be potentially integrated with either a small-scale dish solar or large-scale heliostats and parabolic trough CSP. Na-TEC is a heat engine that generates electricity through the isothermal expansion of sodium ions. The Na-TEC is a closed system that can theoretically achieve conversion efficiencies above 45% when operating between thermal reservoirs at 1150 K and 550 K. However, thermal designs have confined previous single-stage devices to thermal efficiencies below 20%. To mitigate some of these limitations, we consider dividing the isothermal expansion into two stages; one at the evaporator temperature (1150 K) and another at an intermediate temperature (650 K –1050 K). This dual-stage Na-TEC takes advantage of regeneration and reheating, and could be amenable to better thermal management. In light of this, we first designed and developed a thermo-electrochemical model, and thermodynamically demonstrated how the dual-stage device can improve the efficiency by up to 8% points over the best performing single-stage device. We also established an application regime map for the single- and dual-stage Na-TEC in terms of the power density and the total thermal parasitic loss. Moreover, a thermal design of an axisymmetric dual-stage Na-TEC is developed to guide the scale-up and fabrication of sub-components of prototype module. A reduced-order finite-element model is used in conjunction with a Na-TEC thermodynamic model that was developed to determine the total parasitic heat loss of this dual-stage design. A number of simplifications are applied in the reduced-order model to decrease the computational time while maintaining acceptable accuracy. According to this analysis, a maximum efficiency of 29% and a maximum power output of 125 W can be achieved. Ultimately, we were able to demonstrate thermal efficiency improvements of the Na-TEC heat engine from 19% up to 40.3%, in a dual-stage (non-optimized) prototype module that we designed, fabricated, and tested with high temperature stage at 923 K. Furthermore, a cost-performance analysis for this improved dual-stage design was carried out for distributed-CSP systems. A high-level techno-economic analysis (TEA) explores four scenarios where a Na-TEC is used as the heat engine for a distributed-CSP system. Overnight capital cost and levelized cost of electricity (LCOE) are estimated for a system lifetime of 30 years, revealing that overnight capital costs in a range from $3.57 to $17.71 per We are feasible, which equate to LCOEs from 6.9 to 17.2 cents/kWh e -1 . This analysis makes a significant contribution by concurrently quantifying the efficiency and unit costs for a range of multistage configurations, and demonstrating that a Na-TEC may be a promising alternative to Stirling engines for distributed-CSP systems at residential scale of 1–5 kW e .

14 SOLAR ENERGY↗

A Real-Time Operations Manual for the IEEE 118 Bus Transmission Model

This document presents a sample operations manual for the IEEE 118 Bus Model, which is a synthetic test case developed in 1962 from a section of the transmission grid operated by American Electric Power (AEP). The model is one of the most used synthetic test cases for development of power system applications and is referenced by over 9000 papers. However, the model lacks any context for use with real-time energy management system (EMS) applications, including common considerations, such as generator ramp rates, reactive capabilities, operating limits, and other information typically used by power system operators for real-time decision making. This manual divides the IEEE 118 Bus Model into three operating areas, defines various operating limits, and sets recommended operating procedures for responding to a few types of emergency operating conditions. The manual can be used in support of a wide variety of human-in-the-loop evaluation methodologies for new advanced power applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantifying the Financial Impacts of Electric Vehicles on Utility Ratepayers and Shareholders [Slides]

Widespread electric vehicle (EV) adoption is critical for meeting economy-wide decarbonization goals and, as a result, states are considering enabling policies and rate designs to accelerate EV deployment. EVs can provide possible financial upside to electric utilities and ratepayers in several ways. For example, from the utility perspective, EVs could drive increased electricity sales and new earnings opportunities through increased capital investments. From the ratepayer perspective, increased electric loads from EVs could reduce average all-in retail rates. The degree to which there are net benefits or costs to shareholders and/or ratepayers depends on how EVs are integrated and managed through enabling grid investments and charging strategies. Using Berkeley Lab’s Financial Impacts of Distributed Energy Resources (FINDER) model that mimics the electric utility investment planning and ratemaking processes, we estimate the utility earnings and customer rate impacts of EVs using a bookend approach of “managed” (i.e., best case) and “mismanaged” (i.e., worst case) charging strategies for a generic summer-peaking, investor-owned, and vertically integrated utility. The analysis also examines the sensitivity of results to different assumptions of EV deployment characteristics, EV impacts on retail electricity sales, incremental distribution system costs, EV charging location, and utility EV enablement costs (i.e., utility costs to invest in EV charging, controls, and communication to deliver and administer EV programs). The results are intended to inform EV policies and deployment strategies that maximize utility system benefits and minimize ratepayer costs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Incentive-Based Control and Coordination of Distributed Energy Resources. Final Report

The rapid growth of low-inertia renewable energy resources represents an immense opportunity for the U.S. to minimize its carbon footprint, while presenting a challenge for system operators as traditional “spinning” generation resources are displaced. This transformation requires solutions to robustly and cost-effectively manage dynamic changes on the grid while ensuring quality of service. There is growing recognition that distributed energy resources (DERs – loads, distributed generation, storage, electric vehicles, etc.) represent a great potential to perform this function. This report details a scalable hierarchical control strategy for coordinating thousands of heterogeneous DERs in order to provide three ancillary gird services: 1) frequency response, a rapid (within 2 seconds) service used to maintain the grid at 60 Hz; 2) regulation response, a larger response used to balance on-going differences in supply and demand on the grid; and, 3) ramping reserve, used to bring on capacity to replace lost generation. The developed control architecture consists of 1) a Distribution Reliability Coordinator (DRC), 2) aggregator controllers, and finally, 3) DER controllers. The DRC coordinates all the flexible loads and distributed energy resources on the distribution system and bids the aggregate flexibility into the wholesale market. The DRC also performs resource allocation (deciding how the flexible devices on the distribution system will be dispatched) to meet the requirements for each of the three ancillary services. The aggregators control a collection of devices that are geographically co-located and provide a platform to aggregate their flexibility and mitigate uncertainty associated with a single flexible load by managing a large aggregation of similar loads (so that any stochastic effects average out). Finally, DER controllers (for example, thermostats for air conditioners, chargers for electric vehicles) adjust the power consumption of individual devices to ensure accurate and reliable delivery of the requested grid services. Evaluation and validation of this approach was conducted with a mixture of simulation and hardware testing for a range of DERs in residential (air conditioners and water heaters), commercial HVAC (ventilation fans and central chiller plants), and micro-grids (battery energy storage, solar PV etc.). This culminated in DER hardware and simulation models operating in conjunction with grid simulations as part of a large scale federated test-bed demonstration. Simulations of over 10,000 controllable residential devices (a combination of air conditioners, water heaters, batteries, and electric vehicles) demonstrated that this advanced control approach could simultaneously meet all three grid services. Furthermore, hardware-in-the-loop testing was performed with operational micro-grid and commercial building HVAC equipment. The micro-grid equipment (representing PV, battery storage, and back-up generators) demonstrated the ability to meet all frequency response requirements (except ramping time). The commercial building HVAC ventilation equipment successfully provided the regulating response service. An Industry Advisory Board (IAB) was formed and engaged throughout the project to get feed-back on project risks and potential commercialization barriers. Their input was invaluable in identify key risks stemming from regulatory and market access challenges, financial risks from under-performance, and competitive threats from utility-scale solutions such as integrated storage. A phased commercialization plan was developed that addresses continued risk reduction (value proposition refinement and performance uncertainty assessments), piloting through field demonstrations with key stakeholders, and finally, deployment as an emerging standard for DER control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Managed Fast-Charging Model for Electric Vehicle Fleets with High Utilization and Multiple Charge-Acceptance Curves

A predictive control/scheduling optimization model is proposed for managed charging of an electric vehicle (EV) fleet - under time-of-use energy and demand prices, high vehicle utilization frequency (short dwell times), multiple charge- acceptance curves (configurable charging rates), and flexible vehicle demand. This context is particularly relevant for flight schools (small electric aircraft) or other commercial facilities where an EV fleet performs multiple operating and fast-charging sessions on the same day. The proposed model performs both the operational and charging scheduling of the vehicles, which is not typically done for residential managed charging and significantly increases problem complexity. The problem is formulated as a MILP model and a case study of a small fast-charging station is presented. Results demonstrate a significant reduction in operating cost, mainly from peak shaving during high demand price periods, achieved by coordinating the operation of different vehicles, chargers and charging rates.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

Fast, Controllable, and Modular Solid-State Circuit Breaker Design for Battery Management Systems

Electric power grid is experiencing a growing number of distributed and inertia-free generation resources. To facilitate the growing generation and load demands, and ensure stable operation, energy storage systems, especially behind-themeter-storage (BTMS), have emerged as a potential candidate. BTMS plays a vital role in the grid storage sector and supports high power charging for EVs. However, the potential of thermal runaway and associated safety concerns in the batteries can hamper their widespread adoption. In this work, we provide a solution for a fast and controllable discharge of a cell that was identified as a stressful/faulty, in the battery pack, and fast circuit breaking leveraging the Solid-State Circuit Breaker (SSCB) technology which provides active control over the cell connection as opposed to conventional passive solutions. Testing on the simulation platform successfully validated the concept, demonstrating its efficacy. Controlled discharge testing with 20Ah LiFePO4 Lithium Iron Phosphate (LFP) cells from 1C-10C current rate on the hardware prototype corroborated simulation results, demonstrating design feasibility and providing essential data for its performance and thermal characteristics, while also revealing limitations that inform areas for further optimization.

33 ADVANCED PROPULSION SYSTEMS↗

Resilience Metrics and Framework for Distributed Wind Presentation

This presentation communicates information about the MIRACL project Resilience Metrics report and Resilience Framework report. It was created for the 2021 MIRACL advisory board meeting. We propose a three-tiered approach for the resilience framework. At the top level, we consider the time horizons on which resilience will be evaluated and executed. At the middle level, we consider the core functions of resilience, which span across the time horizons. At the lower level, we consider the process steps that correspond to implementing practices for resilience in each of the core functions. The framework considers three time horizons in order to enable organizations to assess and improve their system’s resilience throughout its lifecycle. We call these time horizons the planning, operational, and future stages. The planning stage uses organizational needs and current system evaluation to prepare for potential hazards. The operational stage seeks to execute responses to hazards as prudently and efficiently as possible to maintain system resilience. The future stage seeks to improve on current system resilience and feeds back into the planning stage to promote continuous improvement. While all three time horizons are important when considering a specific topic, the planning and evaluation phase (i.e., what is done in advance of the event) is critical in defining a system’s resilience characteristics and in outlining how a system responds to an event. This framework intentionally emphasizes the planning stage to highlight the overarching emphasis of this effort, not to imply that the other two time-related horizons (i.e., operational and change the future) are less important. The core functions in the framework are identify, prepare, detect, adapt, and recover. These five functions stem from a rigorous analysis of definitions used across the industry, and they represent the core capabilities that an organization must have to enable lifecycle resilience. Within each core function, process steps are described that help walk an organization through the information gathering, evaluation, decision-making, and implementation processes they will need to ensure their resilience goals are maintained throughout the system and the system lifecycle. Also highlighted in the figure is the concept that a resilience framework should be cyclical in nature. Because a system’s resilience is based on finite resources and time, it must continually evolve through this framework’s risk management and capital investment steps at an appropriate level of scope and pace.

17 WIND ENERGY↗

Advanced Load Forecasting

This presentation presents information about electric utility load forecasting in the U.S. It provides an overview of load forecasting and describes the current state of the industry. Current load forecasting challenges, opportunities, and interests are presented, including feedback from a 2024 workshop on Integrated Distribution System Planning. The presentation also describes a variety of NREL tools and capabilities that support utility load forecasting efforts. This was presented as part of NREL's Utility Planning Resources for Energy Transition Webinar Series.

24 POWER TRANSMISSION AND DISTRIBUTION↗