Search NASA⌕ Search

SEARCH · Search NASA

Results for “Atmospheric Radiation Measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Prediction and measurement of direct-normal solar irradiance: A closure experiment

Direct-Normal Solar Irradiance (DNSI), the total energy in the solar spectrum incident on a plane perpendicular to the Sun's direction on a unit area at the earth's surface in unit time, depends only on the atmospheric extinction of sunlight without regard to the details of extinction-whether absorption or scattering. Here the authors describe a set of closure experiments performed in north-central Oklahoma, wherein measured atmospheric composition is input to a radiative transfer model, MODTRAN-3, to predict DNSI, which is then compared to measured values. Thirty six independent comparisons are presented; the agreement between predicted and measured values falls within the combined uncertainties in the prediction (2%) and measurement (0.2%) albeit with a slight bias ((approximately) 1% overprediction) that is independent of the solar zenith angle. Thus these results establish the adequacy of current knowledge of the solar spectrum and atmospheric extinction as embodied in MODTRAN-3 for use in climate models. An important consequence is the overwhelming likelihood that the atmospheric clear-sky absorption is accurately described to within comparable uncertainties.

Halthore, R. N.↗

Titan Atmospheric Entry Radiative Heating

Detailed spectrally and spatially resolved radiance has been measured in the Electric Arc Shock Tube for conditions relevant to Titan entry, varying atmospheric composition, free-stream density (equivalent to altitude) and shock velocity. Permutations in atmospheric composition include 1.1, 2, 5 and 8.6 CH4 by mole with a balance of N2 and 1.5 CH4 0.5 Ar 98 N2 by mole, which is consistent with the current understanding of Titan's atmosphere. The effect of gas impurities identified in previous shock tube studies were also examined by testing in pure N2 and deliberate addition of air to the CH4N2 mixtures. The test campaign measured radiation at velocities from 4.7 kms to 8 kms and free-stream pressures from 0.1 to 0.47 Torr. These conditions cover a range of potential trajectories for flight missions, including a direct ballistic trajectory, a fly by or an extremely high speed entry. Radiances measured in this work are substantially larger compared to that reported both in past EAST test campaigns and other shock tube facilities. Depending on the metric used for comparison, the discrepancy can be as high as an order of magnitude. Potential causes for the discrepancy, such as the effect of oxygen due to Air leakage, gas composition and purity are discussed. The present work provides a new benchmark set of data to replace those published in previous studies.

Earth↗

Titan Atmospheric Entry Radiative Heating

Detailed spectrally and spatially resolved radiance has been measured in the Electric Arc Shock Tube for conditions relevant to Titan entry, varying atmospheric composition, free-stream density (equivalent to altitude) and shock velocity. Permutations in atmospheric composition include 1.1, 2, 5 and 8.6 CH4 by mole with a balance of N2 and 1.5 CH4 0.5 Ar 98 N2 by mole, which is consistent with the current understanding of Titan's atmosphere. The effect of gas impurities identified in previous shock tube studies were also examined by testing in pure N2 and deliberate addition of air to the CH4N2 mixtures. The test campaign measured radiation at velocities from 4.7 kms to 8 kms and free-stream pressures from 0.1 to 0.47 Torr. These conditions cover a range of potential trajectories for flight missions, including a direct ballistic trajectory, a fly by or an extremely high speed entry. Radiances measured in this work are substantially larger compared to that reported both in past EAST test campaigns and other shock tube facilities. Depending on the metric used for comparison, the discrepancy can be as high as an order of magnitude. Potential causes for the discrepancy, such as the effect of oxygen due to Air leakage, gas composition and purity are discussed. The present work provides a new benchmark set of data to replace those published in previous studies.

Brandis, A. M↗

The microwave limb sounder for the Upper Atmosphere Research Satellite

The Microwave Limb Sounder was designed to map the concentrations of trace gases from the stratosphere to the lower thermosphere, to improve understanding of the photochemical reactions which take place in this part of the atmosphere. The instrument will measure the intensity of thermal radiation from molecules in the atmosphere at frequencies corresponding to rotational absorption bands of chlorine monoxide, ozone, and water vapor. Molecular concentration profiles will be determined over a height range of 15 to 80 km (20 to 45 km for C10). The 57 deg inclination orbit proposed for the Upper Atmosphere Research Satellite will allow global coverage.

Waters, J. W.↗

Validation of the CERES Shortwave Measurements over Desert and Cloud Scenes

The Clouds and the Earth's Radiant Energy System (CERES) broadband shortwave channel, 0.3 - 5 micron, measures atmosphere and surface reflected solar radiation. CERES provides an in-flight tungsten lamp to monitor the shortwave radiometric stability over the lifetime of the instrument. Initial Tropical Rainfall Measurement Mission (TRMM) tungsten calibration results indicate a 0.6% change over the first six months of mission life. The three channel intercomparison technique and the solar diffuser calibration results show shortwave stabilities of 0.2% and 0.3% for the same time period. Current belief is that the tungsten lamp, not the radiometer, has drifted. Radiometers, optics, and onboard calibrators exposed to the harsh space environment often degrade. Independent validation studies based on bright Earth viewing measurements are necessary to support the in-flight filtered calibration results. Instrument measurements of filtered radiances are

Currey, Chris↗

Galileo Net Flux Radiometer experiment

The Galileo Net Flux Radiometer (NFR) is a probe instrument designed to measure the vertical profile of upward and net radiation fluxes in five spectral bands spanning the range from solar to far infrared wavelengths. These unique measurements within Jupiter's atmosphere, from which radiative heating and cooling profiles will be derived, will contribute to our understanding of Jovian atmospheric dynamics, to the detection of cloud layers and determination of their opacities, and to the estimation of water vapor abundance. The NFR uses an array of pyroelectric detectors and individual bandpass filters in a sealed detector package. The detector package and optics rotate as a unit to provide chopping between views of upward and downward radiation fluxes. This arrangement makes possible the measurement of small net fluxes in the presence of large ambient fluxes. A microprocessor-controlled electronics package handles instrument operation.

Sromovsky, L. A.↗

Radiation in the atmosphere

Questions of radiative transfer in realistic atmospheres are considered along with aspects related to radiative energy budgets and the solar constants, the radiative properties of atmosphere and surfaces, radiation instruments and measurements, and radiative interactions in dynamical systems. A number of special topics are discussed, taking into account remote sensing, air pollution, and the effect of turbulence on the propagation of light through the atmosphere. It is pointed out that numerous recent studies have been conducted of the properties and effects of atmospheric aerosols.

Coulson, K. L.↗

Multifrequency dial sensing of the atmospheric gaseous constituents using the first and second harmonics of a tunable CO2 laser radiation

The results of field measurements of concentration of some gaseous components of the atmosphere along the paths, in Sofia, Bulgaria, using a gas analyzer based on the use of a CO2 laser radiation frequency-doubled with ZnGeP2 monocrystals are presented. The gas analyzer is a traditional long path absorption meter. Radiation from the tunable CO2 laser of low pressure and from an additional He-Ne laser is directed to a colliminating hundredfold Gregori telescope with a 300 mm diameter of the principal mirror. The dimensions of the mirrors of a retroreflector 500 x 500 mm and a receiving telescope allow one to totally intercept the beam passed through the atmospheric layer under study and back.

Zuev, V. E.↗

Recent Developments in DAO's Finite-Volume Data Assimilation System

The Physical-space/Finite-volume Data Assimilation System (fvDAS) is the next generation global atmospheric data assimilation system in development at the Data Assimilation Office at NASA's Goddard Space Flight Center. It is based on a new finite-volume general circulation model jointly developed by NASA and NCAR and on the Physical-Space Statistical Analysis System (PSAS) developed at the DAO. The data assimilation method implemented in CODAS incorporates a simplified version of the model bias estimation and correction algorithm, as described by Dee and da Silva (1998). In this talk we will briefly describe the general system formulation, and focus on the impact of 3 data types recently introduced, namely: 1) cloud tracks winds from the Multi-angle Imaging Spectrometer by the US Air Force, and 3) temperature and moisture information derived from GPS refractivity occultation measurements. The impact of these data types on observation-minus-6hr forecast (O-F) statistics, as well as 5-day forecast skills will be discussed. In addition we will assess the impact of cloud assimilation on top of the atmosphere radiation fields estimated from CERES measurements.

daSilva, Arlindo↗

Diurnal variability of the planetary albedo - An appraisal with satellite measurements and general circulation models

An atmospheric radiation model is used here to illustrate several features associated with modeling the diurnal cycle of the planetary albedo. It is found that even for clear regions there appear to be deficiencies in our knowledge of how to model this quantity. The diurnal amplitude factor, defined as the ratio of the diurnally averaged planetary albedo to that at noon, between two GCMs and measurements made from a geostationary satellite. While reasonable consistency is found, the comparisons underscore difficulties associated with converting local-time albedo measurements, as made from sun-synchronous satellites, to diurnally averaged albedos.

Potter, G. L.↗

MOPITT - A gas correlation spectrometer for tropospheric Earth observations

MOPITT (Measurement of Pollution in the Troposphere) is an instrument that will fly on the EOS AM-1 Polar Orbiting Platform, to be launched in mid-1998. The instrument accurately measures the concentration of carbon monoxide (CO) and methane (CH4) gas in the troposphere, using novel and conventional gas correlation spectroscopy techniques. These techniques are used to measure both the column amount and the vertical profile of the two gases in the troposphere. The instrument is nadir viewing and has cross-track scanning ability. It measures upwelling IR radiation through the atmosphere in the 4.6-micron and 2.3-micron bands for CO detection, and 2.2-micron for CH4. The instrument performance is enhanced using Stirling cycle mechanical coolers to maintain the IR detectors at less than 100 K. MOPITT has a total of eight detector channels to measure the total column of atmospheric CH4 gas to a precision of 1 percent, and to measure CO profiles to a precision of 10 percent. The instrument is self-calibrating to ensure data validity using internal targets and an external cold space view.

Drummond, James R.↗

Effective UV radiation from model calculations and measurements

Model calculations have been made to simulate the effect of atmospheric ozone and geographical as well as meteorological parameters on solar UV radiation reaching the ground. Total ozone values as measured by Dobson spectrophotometer and Brewer spectrometer as well as turbidity were used as input to the model calculation. The performance of the model was tested by spectroradiometric measurements of solar global UV radiation at Potsdam. There are small differences that can be explained by the uncertainty of the measurements, by the uncertainty of input data to the model and by the uncertainty of the radiative transfer algorithms of the model itself. Some effects of solar radiation to the biosphere and to air chemistry are discussed. Model calculations and spectroradiometric measurements can be used to study variations of the effective radiation in space in space time. The comparability of action spectra and their uncertainties are also addressed.

Feister, Uwe↗

Comparison of mesospheric ozone measurements using the LRIR and UVMCS satellite instruments

A comparison between mesospheric ozone profiles determined by two radically different satellite-borne instruments is presented for the period of July to November, 1975. The Limb Radiance Inversion Radiometer measured 9.6-micron O3 emission, while the Ultraviolet Multiple Channel Spectrometer measured the atmospheric attenuation of solar ultraviolet radiation during passage of the OSO-8 satellite across the terminator. Only nine near coincident measurements were found. The individual instruments have estimated precision errors of + or - 10 to 15 percent. Agreement between ozone values as measured by the two techniques for specific cases varies between 10 and 20 percent. The statistical correlation is positive and significant at all altitudes where both instruments had reasonable signal-to-noise ratio. A maximum correlation of 0.76 occurred at 0.3 mb (about 59 km).

Millier, F.↗

The Limb Infrared Monitor of the Stratosphere /LIMS/ experiment - Temperature and nitrogen dioxide results

The Limb Infrared Monitor of the Stratosphere (LIMS) is a satellite-borne radiometer which scans across the earth's limb, measuring infrared radiation emitted by specific atmospheric gases in a number of broad channels. Instrumentation includes a folded telescope, which focuses the radiation from the limb onto an array of six mercury-cadmium-telluride detectors. A scan mirror within the telescope sweeps the fields of view across the horizon, with each up or down scan lasting 12 seconds. The measurements are inverted to yield distributions of temperature and nitrogen dioxide. The temperature is determined from two channels covering the intervals 595-739 per cm and 645-673 per cm of the 15 micron bands of CO2, with maximum signal to noise ratio of 500-1000. Nitrogen dioxide is determined from measurements in a channel from 1580-1613 per cm, with an S/N of approximately 100. Results show that the LIMS temperature and nitrogen dioxide data are characterized by high precision.

Gille, J. C.↗