Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAM PROFILES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Direct spectral measurements of midinfrared radiation from a laser wakefield accelerator

The formation of plasma waves during laser wakefield acceleration (LWFA) produces time-dependent frequency shifts in the driving laser pulse, extending its spectral content to the infrared. We present direct spectral measurements of multi-mJ infrared pulses from an LWFA. Experimental beam profile measurements and three-dimensional particle-in-cell simulations suggest high focusability of these pulses. Further, particle-in-cell simulations demonstrate that the measurement of side-scattered infrared radiation may serve as a diagnostic of plasma waves and the efficiency of spectral broadening during LWFA.

43 PARTICLE ACCELERATORS↗

Source size measurement options for low-emittance light sources

Radiation-based techniques for measuring electron source sizes are widely used as emittance diagnostics at existing synchrotron sources. Three of these techniques, namely, pinhole imaging, double-slit interferometry, and a K-edge filter-based beam position and size monitor system (ps-BPM), are evaluated for measuring source sizes at low-emittance storage rings. Each technique is reviewed with a detailed system description, design optimization, and practical considerations targeted for small source sizes. Pinhole imaging has the simplest setup and gives the beam profile in both transverse dimensions but with limited resolution. Double-slit interferometry has the highest resolution but with a limited detectable size range. The ps-BPM system shows reasonable resolution for monitoring small source sizes and divergence and can give real-time information of the source position and angle. New facilities may consider an integrated system that combines some or all of these techniques.

43 PARTICLE ACCELERATORS↗

Model-Based Iterative Reconstruction for One-Sided Ultrasonic Nondestructive Evaluation

One-sided ultrasonic nondestructive evaluation (UNDE) is extensively used to characterize structures that need to be inspected and maintained from defects and flaws that could affect the performance of power plants, such as nuclear power plants. Most UNDE systems send acoustic pulses into the structure of interest, measure the received waveform, and use an algorithm to reconstruct the quantity of interest. The most widely used algorithm in UNDE systems is the synthetic aperture focusing technique (SAFT) because it produces acceptable results in real time. Thus, a few regularized inversion techniques with linear models have been proposed which can improve on SAFT, but they tend to make simplifying assumptions that do not address how to obtain reconstructions from large real datasets. In this paper, we propose a model-based iterative reconstruction (MBIR) algorithm designed for scanning UNDE systems. To further reduce some of the artifacts in the results, we enhance the forward model to account for the transmitted beam profile, the occurrence of direct arrival signals, and the correlation between scans from adjacent regions. Next, we combine the forward model with a spatially variant prior model to account for the attenuation of deeper regions. Moreover, we also present an algorithm to jointly reconstruct measurements from large datasets. Finally, using simulated and extensive experimental data, we show MBIR results and demonstrate how we can improve over SAFT as well as existing regularized inversion techniques.

47 OTHER INSTRUMENTATION↗

Feasibility of Lead Fast Reactor Heat Exchanger Tube Online Monitoring

Within virtually all reactor systems with heat exchangers, the thinnest barriers between primary and secondary fluids are the heat exchanger tubes. Consistent with light water reactor experience, the advanced reactor heat exchangers are the most susceptible regions for corrosion and leakage (NRC, 2019). Moreover, traditional inspections and repairs using robotics will be expensive or impractical. On-line structural health corrosion monitoring (OLSHM) is therefore desirable to detect tube degradation prior to leaks that may allow mixing of heat exchanger fluids. Rhetorically many molten salt reactor (MSR) designers plan for on-line monitoring of critical reactor components including heat exchangers but there are no proven OLSHM sensors or systems for MSR heat exchangers. Guided wave ultrasound from the tube-end or ID using conventional low-temperature piezoelectric sensors has been shown to be sensitive to pits and cracks less than 50% through-wall in long pipes and tubes (Narayanan M.M., 2019) . Mode and frequency selection are important for practical sensor design decisions and ultimate performance. The L-0 wave-mode is easily excited by L-mode transducers but they have surface normal wave motion that will be sensitive to and more attenuative because of fluid interaction with the tube surface (Rose J.L., 1994). Shear Horizontal (SH) wave modes have material motion parallel to the tube surface therefore are virtually unaffected by fluid interaction. For SH-0 to be nondispersive in steel, the frequency-thickness product (MHz-mm) must be less than approximately 1.5. SH mode transducers must be coupled by a material that can support shear stress; a thin layer of honey works well for temporary sensors and an adhesive or a brazed metallurgical bond for permanent sensors. If sensors are incorporated into the fabrication process, the same kinds of SH-0 waves can be generated from the stagnant flow area of the tube OD without compromising the heat-exchange tube function. Piezoelectric materials are also available that can withstand harsh temperatures of molten salt heat exchangers (Stevenson T., 2015) (Machura et al., 2008). Though they may not have as high-performance characteristics, their performance only needs to be good enough to detect flaws of interest. This project attempts to demonstrate feasibility to develop a sensor that can be sensitive to flaws of interest and perform long-term monitoring of a molten salt reactor heat exchanger. Benefits to the advanced reactor system include: • Minimizing the expense of a reactor shut down for periodic inspection—only shutdown for cause. • Reduce risk of unexpected tube rupture by detecting flaws before they grow to through-wall leaks. • Cost reduction by minimizing need to design for manual/robotic inspectability. Transducer design, characterization of the beam profile, wedges vs. direct application of piezoelectric sensors, and ultrasonic pulse-echo responses from a representative heat exchange tube with fabricated flaw types are discussed.

On-Line Tube Monitor, Guided Wave Ultrasound, SH-0↗

High-efficiency, large-aperture fifth-harmonic: Generation of 211-nm pulses in ammonium dihydrogen phosphate crystals for fusion diagnostics

High-energy ultraviolet (UV) sources are required to probe hot dense plasmas from fusion experiments by using Thomson scattering resulting from the lower self-generated background from the plasma in the 180 to 230-nm spectral region. Although recently we demonstrated efficient, joule-class fifth harmonic conversion of 1053-nm pulses using a cesium lithium borate (CLBO) crystal, larger crystals are necessary for increased UV energy. This paper presents an alternative approach for fifth-harmonic generation of a large-aperture neodymium laser using ammonium dihydrogen phosphate (ADP). An Nd:YLF laser was optimized to produce square pulses with a flattop, square beam profile (1053 nm, 1 to 2.8 ns, 12 x 12 mm, ≤1.5 J, ≤5 Hz). Noncritical phase matching in ADP suitable for sum–frequency mixing the fourth harmonic with residual fundamental light was achieved by cooling the crystal (65 x 65 x 10 mm) in a two-chamber cryostat to 200 K. The crystal chamber used helium (1 atm) as the thermally conductive medium between the crystal and the crystal chamber, which in turn was surrounded by a high-vacuum chamber that contained a liquid nitrogen reservoir to cool the crystal chamber. Temperature variation of 0.4 K across the crystal aperture was obtained using two 50-W heaters with active feedback. The total conversion efficiency from the fundamental to the fifth harmonic, including surface losses and absorption, was 26%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A highly efficient, 10-J output signal amplifier for ultra-intense all-OPCPA systems

Optical parametric chirped-pulse amplification (OPCPA) using high-energy Nd:glass lasers has the potential to produce ultra-intense pulses (>10 23 W/cm 2 ). We report on the performance of the final high-efficiency amplifier in an OPCPA system based on large-aperture (63 x 63-mm 2 ) partially deuterated potassium dihydrogen phosphate (DKDP) crystals. Here, the seed beam (170 nm, 240 mJ) was provided by the preceding OPCPA stages. The maximum pump-to-signal conversion efficiency of 37% was achieved with a 52-mm-long DKDP crystal and 40-J pump energy at 527 nm due to the flattop super-Gaussian pump beam profile and flat-in-time pulse shape. The 11.8-J output signal was compressed to 19 fs.

42 ENGINEERING↗

SU-E-P-31: Quantifying the Amount of Missing Tissue in a Digital Breast Tomosynthesis

Purpose: To automatically quantify the amount of missing tissue in a digital breast tomosynthesis system using four stair-stepped chest wall missing tissue gauges in the Tomophan™ from the Phantom Laboratory and image processing from Image Owl. Methods: The Tomophan™ phantom incorporates four stair-stepped missing tissue gauges by the chest wall, allowing measurement of missing chest wall in two different locations along the chest wall at two different heights. Each of the four gauges has 12 steps in 0.5 mm increments rising from the chest wall. An image processing algorithm was developed by Image Owl that first finds the two slices containing the steps then finds the signal through the highest step in all four gauges. Using the signal drop at the beginning of each gauge the distance to the end of the image gives the length of the missing tissue gauge in millimeters. Results: The Tomophan™ was imaged in digital breast tomosynthesis (DBT) systems from various vendors resulting in 46 cases used for testing. The results showed that on average 1.9 mm of 6 mm of the gauges are visible. A small focus group was asked to count the number of visible steps for each case which resulted in a good agreement between observer counts and computed data. Conclusion: First, the results indicate that the amount of missing chest wall can differ between vendors. Secondly it was shown that an automated method to estimate the amount of missing chest wall gauges agreed well with observer assessments. This finding indicates that consistency testing may be simplified using the Tomophan™ phantom and analysis by an automated image processing named Tomo QA. In general the reason for missing chest wall may be due to a function of the beam profile at the chest wall as DBT projects through the angular sampling. Research supported by Image Owl, Inc., The Phantom Laboratory, Inc. and Raforninn ehf; Mallozzi and Healy employed by The Phantom Laboratory, Inc.; Goodenough is a consultant to The Phantom Laboratory, Inc.; Fredriksson, Kristbjornsson, Olafsson, Oskarsdottir and Olafsdottir are employed by Raforninn, Ehf.

60 APPLIED LIFE SCIENCES↗

SU-E-T-250: Determining VMAT Machine Limitations of An Elekta Linear Accelerator with Agility MLC for Accurate Modeling in RayStation and Robust Delivery

Purpose: To implement VMAT in RayStation with the Elekta Synergy linac with the new Agility MLC, and to utilize the same vendor softwares to determine the optimum Elekta VMAT machine parameters in RayStation for accurate modeling and robust delivery. Methods: iCOMCat is utilized to create various beam patterns with user defined dose rate, gantry, MLC and jaw speed for each control point. The accuracy and stability of the output and beam profile are qualified for each isolated functional component of VMAT delivery using ion chamber and Profiler2 with isocentric mounting fixture. Service graphing on linac console is used to verify the mechanical motion accuracy. The determined optimum Elekta VMAT machine parameters were configured in RayStation v4.5.1. To evaluate the system overall performance, TG-119 test cases and nine retrospective VMAT patients were planned on RayStation, and validated using both ArcCHECK (with plug and ion chamber) and MapCHECK2. Results: Machine output and profile varies <0.3% when only variable is dose rate (35MU/min-600MU/min). <0.9% output and <0.3% profile variation are observed with additional gantry motion (0.53deg/s–5.8deg/s both directions). The output and profile variation are still <1% with additional slow leaf motion (<1.5cm/s both direction). However, the profile becomes less symmetric, and >1.5% output and 7% profile deviation is seen with >2.5cm/s leaf motion. All clinical cases achieved comparable plan quality as treated IMRT plans. The gamma passing rate is 99.5±0.5% on ArcCheck (<3% iso center dose deviation) and 99.1±0.8% on MapCheck2 using 3%/3mm gamma (10% lower threshold). Mechanical motion accuracy in all VMAT deliveries is <1°/1mm. Conclusion: Accurate RayStation modeling and robust VMAT delivery is achievable on Elekta Agility for <2.5cm/s leaf motion and full range of dose rate and gantry speed determined by the same vendor softwares. Our TG-119 and patient results have provided us with the confidence to use VMAT clinically.

60 APPLIED LIFE SCIENCES↗

SU-E-T-566: Neutron Dose Cloud Map for Compact ProteusONE Proton Therapy

Purpose: To establish the base line of neutron cloud during patient treatment in our new compact Proteus One proton pencil beam scanning (PBS) system with various beam delivery gantry angles, with or without range shifter (RS) at different body sites. Pencil beam scanning is an emerging treatment technique, for the concerns of neutron exposure, this study is to evaluate the neutron dose equivalent per given delivered dose under various treatment conditions at our proton therapy center. Methods: A wide energy neutron dose equivalent detector (SWENDI-II, Thermo Scientific, MA) was used for neutron dose measurements. It was conducted in the proton therapy vault during beam was on. The measurement location was specifically marked in order to obtain the equivalent dose of neutron activities (H). The distances of 100, 150 and 200 cm at various locations are from the patient isocenter. The neutron dose was measured of proton energy layers, # of spots, maximal energy range, modulation width, field radius, gantry angle, snout position and delivered dose in CGE. The neutron dose cloud is reproducible and is useful for the future reference. Results: When distance increased the neutron equivalent dose (H) reading did not decrease rapidly with changes of proton energy range, modulation width or spot layers. For cranial cases, the average mSv/CGE was about 0.02 versus 0.032 for pelvis cases. RS will induce higher H to be 0.10 mSv/CGE in average. Conclusion: From this study, neutron per dose ratio (mSv/CGE) slightly depends upon various treatment parameters for pencil beams. For similar treatment conditions, our measurement demonstrates this value for pencil beam scanning beam has lowest than uniform scanning or passive scattering beam with a factor of 5. This factor will be monitored continuously for other upcoming treatment parameters in our facility.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-C-BRC-04: Efficient Dose Calculation Algorithm for FFF IMRT with a Simplified Bivariate Gaussian Source Model

Purpose: To develop an efficient and accurate independent dose calculation algorithm with a simplified analytical source model for the quality assurance and safe delivery of Flattening Filter Free (FFF)-IMRT on an Elekta Versa HD. Methods: The source model consisted of a point source and a 2D bivariate Gaussian source, respectively modeling the primary photons and the combined effect of head scatter, monitor chamber backscatter and collimator exchange effect. The in-air fluence was firstly calculated by back-projecting the edges of beam defining devices onto the source plane and integrating the visible source distribution. The effect of the rounded MLC leaf end, tongue-and-groove and interleaf transmission was taken into account in the back-projection. The in-air fluence was then modified with a fourth degree polynomial modeling the cone-shaped dose distribution of FFF beams. Planar dose distribution was obtained by convolving the in-air fluence with a dose deposition kernel (DDK) consisting of the sum of three 2D Gaussian functions. The parameters of the source model and the DDK were commissioned using measured in-air output factors (Sc) and cross beam profiles, respectively. A novel method was used to eliminate the volume averaging effect of ion chambers in determining the DDK. Planar dose distributions of five head-and-neck FFF-IMRT plans were calculated and compared against measurements performed with a 2D diode array (MapCHECK™) to validate the accuracy of the algorithm. Results: The proposed source model predicted Sc for both 6MV and 10MV with an accuracy better than 0.1%. With a stringent gamma criterion (2%/2mm/local difference), the passing rate of the FFF-IMRT dose calculation was 97.2±2.6%. Conclusion: The removal of the flattening filter represents a simplification of the head structure which allows the use of a simpler source model for very accurate dose calculation. The proposed algorithm offers an effective way to ensure the safe delivery of FFF-IMRT.

60 APPLIED LIFE SCIENCES↗

MO-FG-202-04: Gantry-Resolved Linac QA for VMAT: A Comprehensive and Efficient System Using An Electronic Portal Imaging Device

Purpose: To automate gantry-resolved linear accelerator (linac) quality assurance (QA) for volumetric modulated arc therapy (VMAT) using an electronic portal imaging device (EPID). Methods: A QA system for VMAT was developed that uses an EPID, frame-grabber assembly and in-house developed image processing software. The system relies solely on the analysis of EPID image frames acquired without the presence of a phantom. Images were acquired at 8.41 frames per second using a frame grabber and ancillary acquisition computer. Each image frame was tagged with a gantry angle from the linac’s on-board gantry angle encoder. Arc-dynamic QA plans were designed to assess the performance of each individual linac component during VMAT. By analysing each image frame acquired during the QA deliveries the following eight machine performance characteristics were measured as a function of gantry angle: MLC positional accuracy, MLC speed constancy, MLC acceleration constancy, MLC-gantry synchronisation, beam profile constancy, dose rate constancy, gantry speed constancy, dose-gantry angle synchronisation and mechanical sag. All tests were performed on a Varian iX linear accelerator equipped with a 120 leaf Millennium MLC and an aS1000 EPID (Varian Medical Systems, Palo Alto, CA, USA). Results: Machine performance parameters were measured as a function of gantry angle using EPID imaging and compared to machine log files and the treatment plan. Data acquisition is currently underway at 3 centres, incorporating 7 treatment units, at 2 weekly measurement intervals. Conclusion: The proposed system can be applied for streamlined linac QA and commissioning for VMAT. The set of test plans developed can be used to assess the performance of each individual components of the treatment machine during VMAT deliveries as a function of gantry angle. The methodology does not require the setup of any additional phantom or measurement equipment and the analysis is fully automated to allow for regular routine testing.

60 APPLIED LIFE SCIENCES↗

Visualization of the microwave beam generated by a plasma relativistic microwave amplifier

A method based on the detection of emission of a dielectric screen with metal microinclusions in open air is applied to visualize the transverse structure of a high-power microwave beam. In contrast to other visualization techniques, the results obtained in this work provide qualitative information not only on the electric field strength, but also on the structure of electric field lines in the microwave beam cross section. The interpretation of the results obtained with this method is confirmed by numerical simulations of the structure of electric field lines in the microwave beam cross section by means of the CARAT code.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of $\pi ^\pm $, $K^\pm $ and proton double differential yields from the surface of the T2K replica target for incoming 31 GeV/c protons with the NA61/SHINE spectrometer at the CERN SPS: NA61/SHINE Collaboration

Measurements of the $\pi^{\pm}$, $K^{\pm}$, and proton double differential yields emitted from the surface of the 90-cm-long carbon target (T2K replica) were performed for the incoming 31 GeV/c protons with the NA61/SHINE spectrometer at the CERN SPS using data collected during 2010 run. The double differential $\pi^{\pm}$ yields were measured with increased precision compared to the previously published NA61/SHINE results, while the $K^{\pm}$ and proton yields were obtained for the first time. A strategy for dealing with the dependence of the results on the incoming proton beam profile is proposed. Furthermore, the purpose of these measurements is to reduce significantly the (anti)neutrino flux uncertainty in the T2K long-baseline neutrino experiment by constraining the production of (anti)neutrino ancestors coming from the T2K target.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

PyEmittance

PyEmittance is a tool for the adaptive measurement of beam emittance (e.g. of an electron beam at OTR/YAG beam profile monitors) using a single quadrupole scan developed at SLAC National Accelerator Laboratory. The Twiss parameters and the 'Bmag' match parameter can also be obtained. It can be used in different beamlines/machines by defining machine-specific configuration files.

Miskovich, Sara A.↗

Incident beam simulations for the CNCS instrument

This data set contains incident beam simulations for the 100 most frequently used configurations of the cold neutron chopper spectrometer (CNCS) instrument at the Spallation Neutron Source. A mcpl output was placed 0.2 m upstream of the sample position. Each file provides enough events to sufficiently sample the beam profile and intensity incident on the sample for that configuration. They can then be used for sample simulations.

47 OTHER INSTRUMENTATION↗

Progress Toward Molten Salt Reactor Heat Exchanger On-Line Monitoring

Within virtually all reactor systems with heat exchangers, the thinnest barriers between primary and secondary fluids are the heat exchanger tubes. Consistent with light water reactor experience, the advanced reactor heat exchangers are the most susceptible regions for corrosion and leakage (NRC, 2019). Moreover, traditional inspections and repairs using robotics will be expensive or impractical. On-line structural health corrosion monitoring (OLSHM) is therefore desirable to detect tube degradation prior to leaks that may allow mixing of heat exchanger fluids. Rhetorically many molten salt reactor (MSR) designers plan for on-line monitoring of critical reactor components including heat exchangers but there are no proven OLSHM sensors or systems for MSR heat exchangers. Guided wave ultrasound from the tube-end or ID using conventional low-temperature piezoelectric sensors has been shown to be sensitive to pits and cracks less than 50% through-wall in long pipes and tubes (Narayanan M.M., 2019) . Mode and frequency selection are important for practical sensor design decisions and ultimate performance. The L-0 wave-mode is easily excited by L-mode transducers but they have surface normal wave motion that will be sensitive to and more attenuative because of fluid interaction with the tube surface (Rose J.L., 1994). Shear Horizontal (SH) wave modes have material motion parallel to the tube surface therefore are virtually unaffected by fluid interaction. For SH-0 to be nondispersive in steel, the frequency-thickness product (MHz-mm) must be less than approximately 1.5. SH mode transducers must be coupled by a material that can support shear stress; a thin layer of honey works well for temporary sensors and an adhesive or a brazed metallurgical bond for permanent sensors. If sensors are incorporated into the fabrication process, the same kinds of SH-0 waves can be generated from the stagnant flow area of the tube OD without compromising the heat-exchange tube function. Piezoelectric materials are also available that can withstand harsh temperatures of molten salt heat exchangers (Stevenson T., 2015) (Machura et al., 2008). Though they may not have as high-performance characteristics, their performance only needs to be good enough to detect flaws of interest. This project attempts to demonstrate feasibility to develop a sensor that can be sensitive to flaws of interest and perform long-term monitoring of a molten salt reactor heat exchanger. Benefits to the advanced reactor system include: • Minimizing the expense of a reactor shut down for periodic inspection—only shutdown for cause. • Reduce risk of unexpected tube rupture by detecting flaws before they grow to through-wall leaks. • Cost reduction by minimizing need to design for manual/robotic inspectability. Transducer design, characterization of the beam profile, and ultrasonic pulse-echo responses from a representative heat exchange tube with fabricated flaw types are discussed.

On-Line Tube Monitor, Guided Wave Ultrasound, SH-0↗

Four-dimensional dynamics of multirotational transition stimulated rotational Raman scattering in air

Stimulated rotational Raman scattering in air is a powerful parasitic process that degrades high intensity laser beams and pulses propagated over significant distances. Conversely, it is used beneficially in the context of Raman lasers. Through this inelastic scattering process, laser photons are converted to higher (anti-Stokes) or lower (Stokes) energies, according to rotational mode transitions in nitrogen and oxygen diatomic molecules. The full wave-mixing problem involves numerous frequencies, and it is consistently assumed that only one rotational mode contributes to the conversion process. We instead present a dynamic 4D multirotational model that is implemented in a parallelized manner within the Virtual Beamline++ optical modeling package allowing high-resolution 4D studies. We highlight the effect that spontaneous emission plays in large and small beam-width setups, even in the highly saturating regime. The weaker transition modes play a large role in the persistent dynamics and can lead to complex spatiotemporal coupling through nonlinear competition of the modes. We highlight how and why these weaker modes persist, how the size and shape of speckle patterns depends highly on the initial beam profile, and how weaker modes can transiently become stronger as a result of such competition.

47 OTHER INSTRUMENTATION↗

Fiber-amplifier-pumped, 1-MHz, 1-µJ, 21-µm, femtosecond OPA with chirped-pulse DFG front-end

High-repetition-rate, high-power, few-cycle mid-infrared lasers with carrier-envelope phase (CEP) stabilization are ideal driving sources for studying strong-field nonlinear processes, such as strong-field driven electron emission, solid-state high-harmonic generation, and nonlinear microscopy. Here, we report on a 1-MHz, 1-μJ, femtosecond, 2.1-µm optical parametric amplifier (OPA), pumped by a Yb-doped fiber chirped-pulse amplifier (CPA) and seeded by a chirped-pulse difference-frequency generation (DFG) front-end providing positively chirped 2.1-μm signal pulses. The home-built multi-stage 1030-nm Yb-doped fiber CPA pump laser generates >55-μJ near-transform-limited (245-fs) pulses at 1 MHz repetition rate using a novel 4-pass all-fiber stretcher/front-end for careful dispersion/spectral management. The chirped-pulse DFG scheme is achieved by wave-mixing the 1030 nm pump pulse with a dispersive wave at 645–735 nm generated in a photonic crystal fiber, allowing passive CEP stability of the 2.1-µm pulses. The 2.1-μm pulse is amplified to 1 μJ in a two-stage dispersion-managed optical parametric amplifier (OPA) with a pump energy of ~21 μJ resulting in 95-fs pulses with nice beam profile without additional pulse compression. Multi-μJ, sub-30 fs pulses can be obtained at full pump energy and additional dispersion compensation. The fiber-amplifier-based mid-infrared OPA can be directly applied to high-harmonic generation in solids and optical-field-driven nanophotonic devices and is a compact front-end for a future high-power, high-repetition-rate, long wavelengths CEP-stabilized source for gas-phase high-order harmonic generation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗