Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAMS, RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Simulation of X-ray Hartmann wavefront sensing with the Synchrotron Radiation Workshop

X-ray wavefront measurement is an important beam diagnostic tool, especially for the diffraction-limited X-ray beam. These in situ diagnostics give a better understanding of beam imperfections, and they enable feedback for possible corrections and/or optical alignment improvements. Hartmann wavefront sensing is one of the promising techniques to perform in situ X-ray wavefront measurements. In this work, a simulation tool of the X-ray Hartmann Wavefront Sensor (HWS) is developed under the Synchrotron Radiation Workshop (SRW) framework. Using this new simulation capability, one can take advantage of the full SRW package to simulate Hartmann wavefront sensing with the beam traveling from the X-ray source to the sample through different X-ray optical components. This SRW HWS simulation tool can help to optimize the wavefront sensor parameters for a specific X-ray energy range. It can also simulate an in situ wavefront measurement experiment with a particular beamline optical layout and predict the expected results of the wavefront measurement under different beamline configurations.

36 MATERIALS SCIENCE↗

Parametric study of high-energy ring-shaped electron beams from a laser wakefield accelerator

Abstract Laser wakefield accelerators commonly produce on-axis, low-divergence, high-energy electron beams. However, a high charge, annular shaped beam can be trapped outside the bubble and accelerated to high energies. Here we present a parametric study on the production of low-energy-spread, ultra-relativistic electron ring beams in a two-stage gas cell. Ring-shaped beams with energies higher than 750 MeV are observed simultaneously with on axis, continuously injected electrons. Often multiple ring shaped beams with different energies are produced and parametric studies to control the generation and properties of these structures were conducted. Particle tracking and particle-in-cell simulations are used to determine properties of these beams and investigate how they are formed and trapped outside the bubble by the wake produced by on-axis injected electrons. These unusual femtosecond duration, high-charge, high-energy, ring electron beams may find use in beam driven plasma wakefield accelerators and radiation sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MARSAME Radiological Release Report for Metal Items from Technical Area 53, Set 28

Environmental Protection and Compliance, Environmental Stewardship Group (EPC-ES) has evaluated the survey results for metal items from the Los Alamos Neutron Science Center (LANSCE) at Technical Area 53 (TA-53) and found that the metal items described in Table 1 of this report (identified by Radiation Protection [RP] Tracking Numbers) meet the criteria for unrestricted release under Department of Energy (DOE) Order 458.1 Chg 4, Radiation Protection of the Public and the Environment (DOE 2020) and can be recycled. This conclusion is based on the known history of the metal items and radiation survey data (see the completed RP-Form-031 LANSCE Metals Clearance Log [LANL 2021a] for each item in Attachment 1). Process knowledge indicates that items were released from radiological areas, including radiation areas, prior to the implementation of the 2000 metals moratorium. Therefore, the items are considered unencumbered and are not subject to the moratorium suspension on metal recycling from DOE facilities. Additionally, Los Alamos National Laboratory (LANL) has determined that there is no practical opportunity for internal DOE reuse of this metal. Process knowledge indicates that these metal items were unlikely to ever be in direct contact with the beam and thus are unlikely to have become activated. Surface contamination measurements (both total and removable) showed either no detectable radioactivity or activity levels within the range of background. All measurements for volumetric contamination were indistinguishable from background based on calculated decision limits. Additionally, all gamma isotopic surveys conducted for defense-in depth showed no identifiable gamma radiation from beam activation.

61 RADIATION PROTECTION AND DOSIMETRY↗

High-precision mass measurement of Si 24 and a refined determination of the r p process at the A = 22 waiting point

We report a high-precision mass measurement of 24 Si, performed with the Low Energy Beam and Ion Trap (LEBIT) facility at the National Superconducting Cyclotron Laboratory. The atomic mass excess, 10 753.8 (37) keV, is a factor of 5 more precise than previous results. This substantially reduces the uncertainty of the 23 Al(p ,γ) 24 Si reaction rate, which is a key part of the rapid proton capture (rp) process powering type I x-ray bursts. Furthermore, the updated rate constrains the onset temperature of the (α,p) process at the 22 Mg waiting point to a precision of 9%.

20 ≤ A ≤ 38↗

Progress in the design of the future circular collider FCC-ee interaction region

In this paper we discuss the latest developments for the FCC-ee interaction region layout, which represents one of the key ingredients to establish the feasibility of the FCC-ee. The collider has to achieve extremely high luminosities over a wide range of center-of-mass energies with two or four interaction points. The complex final focus hosted in the detector region has to be carefully designed, and the impact of beam losses and of any type of synchrotron radiation generated in the interaction region, including beamstrahlung, have to be evaluated in detail with simulations. We give an overview of the progress of the whole machine-detector-interface-related studies, among which are the updated mechanical model of the interaction region, the plans for a novel R&D activity of a IR mockup which is just starting, the collimation scheme and evaluation of beam induced backgrounds in the detectors, evaluation of radiation dose in the experimental area, and MDI integration with the detector.

43 PARTICLE ACCELERATORS↗

Optical Spectrometer With a Pulse-to-Pulse Resolution for Terahertz and mm-Wave Signals

The development of ultra-compact particle accelerators and accelerator-based high-power THz generators are some of the top priorities for research and development programs around the world. These tools require the development of accelerating structures, operating in the mm-Wave and THz range, where diagnostics are not available or are insufficient. This article presents the design of a pulse-to-pulse THz spectrometer, primarily developed for diagnostics of accelerating structures and THz radiation sources. In particular, this spectrometer can be used to detect RF pulse shortening caused by vacuum breakdown and beam misalignment in THz accelerators, as well as for bunch length monitoring and radiation source diagnostics. The spectrometer is based on a diffraction grating and is capable of covering a frequency range where RF-based breakdown measurements are not possible. We have built and tested the first prototype with different sources in a frequency range of 0.1-1.0 THz. In this article, we present the physical design, supported numerical simulations, electronics development, and test results.

47 OTHER INSTRUMENTATION↗

Air attenuation of high power XFEL beams

The Linac Coherent Light Source-II, a high-repetition-rate x-ray free electron laser, produces high average power as well as high peak power. Air is a key radiation safety element, helping to contain the FEL beams from reaching accessible areas. At high average power, air absorption can produce a high temperature and low-density channel along the x-ray beam path. In this case, the x-ray attenuation no longer follows the Beer-Lambert equation, e-μx . Air attenuation measurements were performed with x-rays focused into a gas cell at the LCLS Time-resolved AMO instrument. The air transmission was observed to significantly increase with x-ray power. Simulations were also performed, which include the thermal processes related to the high average power. In comparison to the measurements, the calculated air transmission is higher, confirming that the simulations are conservative and suitable for radiation safety analyses.

42 ENGINEERING↗

Aqueous harvesting of 88 Zr at a radioactive-ion-beam facility for cross-section measurements

Isotope harvesting is a method of collecting the long-lived radioisotopes that build up during the operation of ion-beam facilities in a way that is useful for subsequent research. As a demonstration of this method for the collection of a group IV metal at a fragmentation facility, the high-energy Zr 88 secondary beam produced from a 140-MeV/u Mo 92 primary beam at the National Superconducting Cyclotron Laboratory (NSCL) was stopped in a water target. The setup aimed to mimic the aqueous beam dump that will be implemented at the Facility for Rare Isotope Beams (FRIB). The collected Zr 88 and accompanying Y 88 decay daughter were radiochemically extracted from the solution and made into target samples suitable for neutron-capture cross-section measurements. These samples were then irradiated at two reactor facilities, and the Zr 88 average thermal-neutron-capture cross section ( σ T ) and resonance integral ( I ) were determined to be σ T = ( 8.04 ± 0.63 ) × 10 5 b and I = ( 2.53 ± 0.28 ) × 10 6 b. The σ T value agrees well with previous results and I , determined for the first time here, was found to be the largest measured resonance integral by two orders of magnitude. The Y 88 thermal-neutron-capture cross section was determined to be less than 1.8 × 10 4 b. This work demonstrates the steps needed to make cross-section measurements with samples produced via aqueous isotope harvesting.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Characterization of self-magnetic pinch (SMP) radiographic diode performance on RITS-6 at Sandia National Laboratories. I. Diode dynamics, DC heating to extend radiation pulse

Radiographic diodes focus on an intense electron beam to a small spot size to minimize the source area of energetic photons for radiographic interrogation. The self-magnetic pinch (SMP) diode has been developed as such a source and operated as a load for the six-cavity radiographic integrated test stand (RITS-6) inductive voltage adder driver. While experiments support the generally accepted conclusion that a 1:1 aspect diode (cathode diameter equals anode–cathode gap) delivers optimum SMP performance, such experiments also show that reducing the cathode diameter, while reducing spot size, also results in reduced radiation dose, by as much as 50%, and degraded shot reproducibility. Analysis of the effective electron impingement angle on the anode converter with time made possible by a newly developed dose-rate array diagnostic indicates that fast-developing oscillations of the angle are correlated with early termination of the radiation pulse on many of the smaller-diameter SMP shots. This behavior as a function of relative cathode size persists through experiments with output voltages and currents up to 11.5 MV and 225 kA, respectively, and with spot sizes below approximately few millimeters. Since simulations to date have not predicted such oscillatory behavior, considerable discussion of the angle behavior of SMP shots is made to lend credence to the inference. We report there is clear anecdotal evidence that DC heating of the SMP diode region leads to stabilization of this oscillatory behavior. This is the first of two papers on the performance of the SMP diode on the RITS-6 accelerator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Single-nucleon knockout cross sections for reactions producing resonance states at or beyond the drip line

Single-nucleon knockout cross sections from fast secondary beams of the proton-drip-line nuclei 9 C, 13 O, and 17 Ne on a 9 Be target have been studied with emphasis on the production of resonance states. These states were identified by their invariant mass, and resonances with two-, three-, and five-body exit channels were examined. The measured cross sections for these states were compared with eikonal-model predictions using shell-model or variational Monte Carlo spectroscopic factors. The experimental yields were found to be suppressed relative to the model predictions, especially when a well-bound neutron or proton is removed. This suppression exceeds that found systematically in measured inclusive cross sections to particle-bound final states. In neutron knockout from 9 C and 13 O projectiles, this suppression of the unbound ground-state residuals yield is a factor of two to three times larger than that found in the bound final-state studies. Modifications to the structure of these systems due to coupling of the shell-model configurations to the continuum is expected to contribute to this extra suppression, especially when the final state is a near-threshold resonance. Furthermore, other considerations including the role of nuclear dynamics may be required to explain all the observed trends.

6 ≤ A ≤ 19↗

Influence of fabrication on microstructure and heat affected zone width in weldments of nuclear reactor pressure vessel steel

Advanced manufacturing routes such as electron beam welding and powder metallurgy with hot isostatic pressing are increasingly used across energy and aerospace industries, where the reliable prediction of weld behavior and heat affected zone (HAZ) evolution is critical. This study examines how fabrication routes and post-weld heat treatments influence phase distribution, crystallite size, microstrain, and dislocation density in nuclear reactor pressure vessel steels using synchrotron X-ray diffraction (SXRD). Retained austenite occurs only in samples that did not undergo austenitization, whereas an austenitizing heat treatment fully eliminates retained austenite and produces a more uniform microstructure across the weldment in terms of phase fraction, dislocation density, and microstrain. The Rosenthal solution underestimates the HAZ width for powder metallurgy samples. A newly proposed modified Rosenthal solution, reducing density by accounting for porosity, matches the SXRD-measured HAZ width with a 0.65% error. Structure–property correlations reveal that dislocation density correlates strongly with nanohardness in homogenous microstructures, while in heterogenous weldments nanohardness is further influenced by the presence of dissimilar phase boundaries. These findings provide new insight into the thermal and microstructural response of powder metallurgy fabricated steels and offer a framework for optimizing welding procedures and heat treatments in advanced manufacturing applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the Ground State Spin and Parity of 22 Al Disfavors Halo Formation

We report the decisive resolution of the ground state spin and parity of the proton–drip line nucleus 22 Al, a prime candidate for a proton halo. The resolution stems from the first 𝛽-delayed charged particle emission experiment in the gas stopping area at the Facility for Rare Isotope Beams (FRIB), leveraging high-intensity, low-energy beams extracted from the Advanced Cryogenic Gas Stopper (ACGS). The pristine beam quality from FRIB and the ACGS enabled a sensitive particle identification technique using thin silicon detectors, allowing for the suppression of the dominant proton background and the first observation of the weak 𝛽-delayed 𝛼 transition from the isobaric analog state in 22 Mg to the 18 Ne ground state. This observation uniquely fixes the 22 Al ground state as 4 + . The valence proton is confined by a dominant 𝑑-wave centrifugal barrier which, combined with the Coulomb repulsion, hinders the tunneling required for halo formation despite the exceptionally low proton separation energy of 22 Al.

20 ≤ A ≤ 38↗

Proton Shell Gaps in N = 28 Nuclei from the First Complete Spectroscopy Study with FRIB Decay Station Initiator

The first complete measurement of the $β$-decay strength distribution of $_{17}^{45}$Cl 28 was performed at the Facility for Rare Isotope Beams (FRIB) with the FRIB Decay Station Initiator during the second FRIB experiment. The measurement involved the detection of neutrons and $γ$ rays in two focal planes of the FRIB Decay Station Initiator in a single experiment for the first time. This enabled an analytical consistency in extracting the $β$-decay strength distribution over the large range of excitation energies, including neutron unbound states. Here, we observe a rapid increase in the $β$-decay strength distribution above the neutron separation energy in $_{18}^{45}$Ar 27 . This was interpreted to be caused by the transitioning of neutrons into protons excited across the Z = 20 shell gap. The SDPF-MU interaction with reduced shell gap best reproduced the data. The measurement demonstrates a new approach that is sensitive to the proton shell gap in neutron rich nuclei according to SDPF-MU calculations.

39 ≤ A ≤ 58↗

Radiation shielding analysis of the concrete hutch of a long beamline of the Advanced Photon Source Upgrade project

The radiation shielding analysis of the external concrete enclosure of a feature long beamline of the Advanced Photon Source Upgrade project is described in this work. The beamline has 2 undulators that can operate in two different configurations and the source terms are estimated for the worst configuration using the SRW code in the OASYS package as well as the STAC8 code. The shielding analysis is carried out using the STAC8 code, and for the case of pink beam, with the FLUKA code also. Effective dose rates on contact with the outside surface of the concrete walls for pink, reflected full spectrum and monochromatic beams are calculated. For the monochromatic beams, 2 sets of discrete bandwidths (BW) from the Double Crystal Monochromator (DCM) and the full reflectance of the Double Multilayer Monochromator (DMM) are used. Further, due to the size of the direct beam and the energy domain of interest in the direct and scattered fields, the importance of the equivalent dose to the lens of the eye is discussed with respect to the shielding calculations of such facilities. The dose rates outside the concrete hutch in the lateral directions calculated using STAC8 is about 50% higher than the FLUKA results for the case of pink beam but may be considered as a reasonable agreement due to the differences in the calculational methodologies. Those dose rates in the lateral and forward directions are higher for the pink beam to allow full occupancy from the radiation protection point of view. For the full spectrum after 3 reflections, the effective dose rates are less than 0.5 Sv/h in the lateral direction but is higher in the forward region below about 22° with respect to the beam direction. For the DCM beams, except for the scenario with one mirror and 0.1%BW, all dose rates are less than 0.5 Sv/h outside the concrete hutch in the lateral directions. Here, the higher harmonics are what contributes to the dose outside the shield and the bandwidths assumed to derive the photon flux thus becomes important. The dose rates with the DMM are generally lower compared to the 0.1% BW DCM beam but are higher than the results obtained with XOP calculated bandwidths.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Effect of Radiation Damage on the Charge Collection Efficiency of Silicon Avalanche Photodiodes

Understanding radiation effects on avalanche photodiodes (APDs) is important because they are used in several applications involving harsh radiation environments. APDs are used as photosensors in applications where speed and detection efficiency are critical. Proton irradiation experiments on a commercial off-the-shelf APD demonstrated that the irradiation flux and applied reverse bias have a strong influence on the severity of radiation effects. This is measured using the ion beam induced charge (IBIC) technique in which charge collection efficiency (CCE) describes the signal response from a device. CCE can degrade substantially due to radiation damage, but recent measurements show that certain combinations of irradiation flux and reverse bias can lead to increases in CCE up to 186% ± 24% for irradiations with 2 MeV protons at a fluence of 6.4 × 10 11 cm –2 . This defect-enhanced charge multiplication (DECM) only appeared when the reverse bias during irradiation ranged from 170 to 1830 V out of a maximum operating bias of 2000 V and the proton flux ranged from 9.8 × 10 7 to 3.4 × 10 9 cm –2 s –1 . Furthermore values outside of either range led to losses in CCE. It is expected that DECM should be encountered in other devices, especially those with sufficiently high electric fields to cause impact ionization.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MARSAME Radiological Release Report for Metal Items from TA 53, Set 20

EPC-ES has evaluated the survey results for metal items from the Los Alamos Neutron Science Center (LANSCE) and found that the metal items described in Table 1 of this report (identified by RP Tracking Numbers) meet the criteria for unrestricted release under DOE Order 458.1 Radiation Protection of the Public and the Environment (DOE 2020) and can be recycled. This conclusion is based on the known history of the metal items and on radiation survey data (see the completed RP-Form-031 LANSCE Metals Clearance Log for each item). None of the items in this report are located within radiological areas. Therefore, the items are considered unencumbered and are not subject to the moratorium suspension on metal recycling from Department of Energy facilities. Additionally, LANL has determined that there is no practical opportunity for internal DOE reuse or recycling of this metal. Process knowledge indicates that these metal items were unlikely to ever be in direct contact with the beam and thus are unlikely to have become activated. Surface contamination measurements (both total and removable) showed either no detectable radioactivity or activity levels within the range of background. All measurements for volumetric contamination were indistinguishable from background based on calculated decision limits. Additionally, all gamma isotopic surveys conducted for defense-in-depth showed no identifiable gamma radiation from beam activation.

54 ENVIRONMENTAL SCIENCES↗

Synchrotron-based Characterization Techniques for Radiation Detection Materials and Devices: An Overview

High-performance room-temperature radiation detectors (high energy resolution for spectrometers, high spatial resolution for imaging devices, and low defect-density for high flux applications) are needed for photon energies (>20 keV) that are not well suited for silicon detectors. Applications for such radiation detectors include nonproliferation, synchrotron, medical, astrophysics, and homeland security. Material- and device- characterization to understand and solve the limiting factors of radiation detection materials and devices is a core element of a radiation detector development R&D program. This presentation will give an overview on the two main synchrotron-based characterization techniques that have been employed by the authors in the last ~20 years: (1) White Beam X-ray Diffraction Topography and (2) Micron-scale detector mapping. A perfect (one domain) crystal (radiation detection material) is a requirement to achieve a highperformance radiation detector. White Beam X-ray Diffraction Topography (WBXDT) allows the rapid screening of the crystallinity of the detector material. With WBXDT we can quickly screen CZT and other crystals to make sure they have only one domain, and to see the presence of extended defects and strain fields.

Camarda, Giuseppe S.↗

Near-Infrared Noise in Intense Electron Beams

Requirements for the noise in electron beams (NEB) have recently approached the Shot-noise level in some new applications. The density fluctuations of intense beams in the near-infrared (NIR) region are being measured at the Fermilab Accelerator Science and Technology (FAST) facility. The main goal of the experiment is to accurately compare the Shot-noise model with the observations of optical transition radiation (OTR) generated by a relativistic electron beam ($\gamma \approx 63$), transiting an Aluminium metal surface. In addition, some evidence for longitudinal space-charge-induced microbunching for the chicane-compressed beam was obtained with coherent enhancements up to 100 in the various bandwidth-filtered NIR OTR photodiode signals. With micropulse charges up to 1 nC, the beam parameters are close to those proposed for a stage in an Electron-Ion Collider (EIC) with coherent electron cooling (CEC). In this paper we present the current progress of the NEB project and compare the low electron energy measurements with ImpactX simulations.

43 PARTICLE ACCELERATORS↗