Search NASA⌕ Search

SEARCH · Search NASA

Results for “Bricks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Laser-matter Interaction with Submerged Samples

With the long-term goal in mind of investigating if one could possibly design a 'universal solid-sample comminution technique' for debris and rubble, we have studied pulsed-laser ablation of solid samples that were contained within a surrounding fluid. Using pulses with fluences between 2 J and 0.3 J, wavelengths of 351 and 527 nm, and samples of rock, concrete, and red brick, each submerged in water, we have observed conditions in which {micro}m-scale particles can be preferentially generated in a controlled manner, during the laser ablation process. Others have studied laser peening of metals, where their attention has been to the substrate. Our study uses non-metallic substrates and analyzes the particles that are ablated from the process. The immediate impact of our investigation is that laser-comminution portion of a new systems concept for chemical analysis has been verified as feasible.

36 MATERIALS SCIENCE↗

A fundamentally new approach to air-cooled heat exchangers.

We describe breakthrough results obtained in a feasibility study of a fundamentally new architecture for air-cooled heat exchangers. A longstanding but largely unrealized opportunity in energy efficiency concerns the performance of air-cooled heat exchangers used in air conditioners, heat pumps, and refrigeration equipment. In the case of residential air conditioners, for example, the typical performance of the air cooled heat exchangers used for condensers and evaporators is at best marginal from the standpoint the of achieving maximum the possible coefficient of performance (COP). If by some means it were possible to reduce the thermal resistance of these heat exchangers to a negligible level, a typical energy savings of order 30% could be immediately realized. It has long been known that a several-fold increase in heat exchanger size, in conjunction with the use of much higher volumetric flow rates, provides a straight-forward path to this goal but is not practical from the standpoint of real world applications. The tension in the market place between the need for energy efficiency and logistical considerations such as equipment size, cost and operating noise has resulted in a compromise that is far from ideal. This is the reason that a typical residential air conditioner exhibits significant sensitivity to reductions in fan speed and/or fouling of the heat exchanger surface. The prevailing wisdom is that little can be done to improve this situation; the 'fan-plus-finned-heat-sink' heat exchanger architecture used throughout the energy sector represents an extremely mature technology for which there is little opportunity for further optimization. But the fact remains that conventional fan-plus-finned-heat-sink technology simply doesn't work that well. Their primary physical limitation to performance (i.e. low thermal resistance) is the boundary layer of motionless air that adheres to and envelops all surfaces of the heat exchanger. Within this boundary layer region, diffusive transport is the dominant mechanism for heat transfer. The resulting thermal bottleneck largely determines the thermal resistance of the heat exchanger. No one has yet devised a practical solution to the boundary layer problem. Another longstanding problem is inevitable fouling of the heat exchanger surface over time by particulate matter and other airborne contaminants. This problem is especially important in residential air conditioner systems where often little or no preventative maintenance is practiced. The heat sink fouling problem also remains unsolved. The third major problem (alluded to earlier) concerns inadequate airflow to heat exchanger resulting from restrictions on fan noise. The air-cooled heat exchanger described here solves all of the above three problems simultaneously. The 'Air Bearing Heat Exchanger' provides a several-fold reduction in boundary layer thickness, intrinsic immunity to heat sink fouling, and drastic reductions in noise. It is also very practical from the standpoint of cost, complexity, ruggedness, etc. Successful development of this technology is also expected to have far reaching impact in the IT sector from the standpointpoint of solving the 'Thermal Brick Wall' problem (which currently limits CPU clocks speeds to {approx}3 GHz), and increasing concern about the the electrical power consumption of our nation's information technology infrastructure.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Towards an Understanding of the Role of Aragonite in the Mechanical Properties of Nacre

Nacre, also known as mother-of-pearl, is a biocomposite material that exhibits higher strength and fracture toughness than its component materials. It derives its strength from the brick-and-mortar layering of aragonite (CaCO{sub 3}) platelets and organic binder. It is believed that the protein binder helps redistribute the stress throughout all tablets for optimal mechanical performance. In this study, we attempt to measure the mechanical properties of aragonite within nacre and compare them to bulk aragonite and bulk nacre and understand the redistribution of stresses. Here we show that x-ray diffraction techniques are useful for isolating and measuring strain of crystallites within a composite material. Our results show that the apparent stiffness of aragonite varies with crystallographic directions and is higher than the stiffness of bulk nacre in all cases, meaning that aragonite tablets are exposed to less than the average bulk stress. The average force applied to the bulk sample is partitioned between the aragonite and the binder, so that the protein layer bears as much as 27.2% of the total applied force. Different crystallographic directions exhibit behaviors different than bulk aragonite or bulk nacre. These are related to texture of aragonite platelets (i.e. preferred orientations within nacre). By examining nacre, we can obtain a better understanding of the mechanical relationship between the ceramic and polymer in composite materials. We expect that x-ray diffraction will become the standard method for probing the mechanical properties of composite materials.

36 MATERIALS SCIENCE↗

Convergence and Quantum Advantage of Trotterized MERA for Strongly-Correlated Systems

Strongly-correlated quantum many-body systems are difficult to study and simulate classically. We recently proposed a variational quantum eigensolver (VQE) based on the multiscale entanglement renormalization ansatz (MERA) with tensors constrained to certain Trotter circuits. Here, we determine the scaling of computation costs for various critical spin chains which substantiates a polynomial quantum advantage in comparison to classical MERA simulations based on exact energy gradients or variational Monte Carlo. Algorithmic phase diagrams suggest an even greater separation for higher-dimensional systems. Hence, the Trotterized MERA VQE is a promising route for the efficient investigation of strongly-correlated quantum many-body systems on quantum computers. Furthermore, we show how the convergence can be substantially improved by building up the MERA layer by layer in the initialization stage and by scanning through the phase diagram during optimization. For the Trotter circuits being composed of single-qubit and two-qubit rotations, it is experimentally advantageous to have small rotation angles. We find that the average angle amplitude can be reduced considerably with negligible effect on the energy accuracy. Benchmark simulations suggest that the structure of the Trotter circuits for the TMERA tensors is not decisive; in particular, brick-wall circuits and parallel random-pair circuits yield very similar energy accuracies.

Miao, Qiang [Duke Quantum Center, Duke University,↗

Vanderbilt Alumni Hall

This dataset includes processed and raw data from the Vanderbilt Alumni Hall Building (VAH) located on the University of Vanderbilt Campus in Nashville, TN. VAH is a mixed use commercial building (LEED Gold Certified) that consists of classrooms, meeting rooms, office rooms, conference rooms, an exercise room, and others. This dataset spans one year of time-series data from 2019 and includes measurements corresponding to whole building electrical power, thermal power, zone level thermal power, set-point, indoor temperature, humidity, water and air side supply and return temperatures and flow rates as CSV files. In addition to the measurements, a metadata .json file, and a .ttl file to visualize the data as per BRICK schema are also included.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Processed data from the Building Management System for the System Engineering Building.

The dataset spans November 2018 to May 2020 and includes time-series measurements corresponding to supply and return temperatures of air and water, air, hot water and cold water flow rates, energy and power consumption, set-points etc. as a single CSV file. In addition to the measurements, a metadata .json file, and a .ttl file to visualize the data as per BRICK schema are also included.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

AlphaBuilding - Synthetic Buildings Operation Dataset

This is a synthetic building operation dataset which includes HVAC, lighting, miscellaneous electric loads (MELs) system operating conditions, occupant counts, environmental parameters, end-use and whole-building energy consumptions at 10-minute intervals. The data is created with 1395 annual simulations using the U.S. DOE detailed medium-sized reference office building, and 30 years' historical weather data in three typical climates including Miami, San Francisco, and Chicago. Three energy efficiency levels of the building and systems are considered. Assumptions regarding occupant movements, occupants' diverse temperature preferences, lighting, and MELs are adopted to reflect realistic building operations. A semantic building metadata schema - BRICK, is used to store the building metadata. The dataset is saved in a 1.2 TB of compressed HDF5 file. This dataset can be used in various applications, including building energy and load shape benchmarking, energy model calibration, evaluation of occupant and weather variability and their influences on building performance, algorithm development and testing for thermal and energy load prediction, model predictive control, policy development for reinforcement learning based building controls.

AlphaBuilding↗

Measure Guideline: Deep Energy Enclosure Retrofit for Interior Insulation of Masonry Walls and Flat Roofs

Measure Guideline: Deep Energy Enclosure Retrofit for Zero Energy Ready House Flat Roofs BSC TO5 Task 7.4 Deep Energy Enclosure Retrofit (DEER) for Interior Insulation of Masonry Walls Lawrence, MA 01840 This Measure Guideline describes a deep energy enclosure retrofit solution for insulating mass masonry buildings from the interior. It describes the retrofit assembly, technical details, and installation sequence for retrofitting masonry walls. Interior insulation of masonry retrofits might adversely affect the durability of the wall. This guideline includes a review of decision criteria pertinent to retrofitting masonry walls from the interior and the possible risk of freeze-thaw damage. This Measure Guideline is intended to support contractors who are implementing an interior insulation-based high-performance enclosure retrofit for masonry buildings and designers who are looking to design such retrofits. It may also be helpful to building owners who wish to learn more about strategies that are available for deep energy enclosure retrofit of masonry residential buildings on the interior. This Measure Guideline is important to the high-performance retrofit industry because the solution described here provides an opportunity to retrofit masonry buildings with ambitious energy performance goals by insulating them from the interior without disturbing their exterior appearance. BSC TO5 Task 7.4 Deep Energy Enclosure Retrofit (DEER) for Zero Energy Ready House (ZERH) Flat Roofs House Jamaica Plain, MA 02130 This Measure Guideline provides design and construction information for a deep energy enclosure retrofit solution of a flat roof assembly. It describes the strategies and procedures for an exterior retrofit of a flat wood-framed roof with brick masonry exterior walls using exterior and interior (framing cavity) insulation. The approach supported in this guide could also be adapted for use with flat wood-framed roofs with wood-framed exterior walls. Designers, contractors, and building code officials will benefit from the information contained in this Measure Guideline. The guide may also be helpful to building owners who wish to learn more about strategies for deep energy enclosure retrofit of flat roofs. This Measure Guideline is important to the high-performance retrofit industry because it demonstrates techniques for retrofitting flat roofs from the exterior, which is less disruptive to the living space and allows the structure to remain occupied during the project. It also illustrates a solution for preparing homes to become zero energy ready.

Array↗

Analysis of Joist Masonry Moisture Content Monitoring

BSC TO5 Task 7.2 Analysis of Joist Masonry Moisture Content Monitoring House - Lawrence, MA 01840 This work involved the field monitoring of embedded wood joist ends in a solid brick building in zone 5A that was retrofitted with interior insulation. Eleven joists throughout the building (which have a variety of orientations, exposures, and masonry wall types) were monitored for wood MCs at the embedded joist ends and for temperatures and RHs within the joist pocket. Indoor and outdoor conditions were also recorded. Results were collected for 28 months (December 2012-April 2015). One limitation was that the renovation was still ongoing; limited wintertime construction heating and no permanent occupancy were factors. Much of the building experienced cold interior temperatures (e.g., construction heating) during the winters. These were not typical interior heating set points. Because the building was essentially unoccupied, no significant interior moisture was generated. These boundary conditions are not normal service conditions. Overall, the RHs and MCs measured in joist pockets were higher than recommended for longterm durability. Many of the joist pockets had sustained conditions of 100% RH, and many wood MCs were in the 25%-35% range for extended periods. Typical guidance includes: (1) MCs lower than 20% are safe, and (2) decay fungi become active at MCs higher than 28%. ASHRAE xi 160 analysis showed that high RH levels coincided with temperatures that were high enough to support mold growth for most of the monitoring period (60%-70% of the hours) in most joists. However, no damage was seen at the joist ends when the instrumentation was installed or when a joist end sample was removed. This suggests that dense, old-growth framing might be able to survive these MCs without damage. Orientation has a significant effect on RH and MC levels: solar heating and drying kept all southfacing joist MCs well within the safe range. The east and west orientations had mixed results: some were in the safe range, but others exceeded the 20% MC level. The north side joists consistently had the highest MCs. Almost all the joists showed seasonal rises and falls; MC and RH conditions were higher during the summer and lower during the winter. This indicates the temperature gradient caused moisture to be driven inward during the summer. MC plots with driving rain showed no discernable correlations. In the parts of the building that had significant wintertime heating, many joists showed a drop in MC that coincided with the addition of heat, even after insulation and air sealing were installed. The joist ends showed a repeated pattern of MC measurements at their upper and lower ends. The lower joist end was consistently wetter than the upper joist end, which can be attributed to contact with the masonry pocket, gravity drainage of bulk water to the bottom of the pocket, greater drying at the top of the beam or deeper embedment at the bottom of the beam, and a larger air pocket at the top of the beam. The north-facing insulated and uninsulated joist ends were compared; a significant or consistent MC or RH difference was not seen between these cases. All three joist pockets essentially remained at a constant 100% RH.

Array↗

Evaluation of Crawlspace Retrofits in Multifamily Buildings

In 2011 and early 2012, Building Science Corporation (BSC) collaborated with Innova Services Corporation on a multifamily community un-vented crawlspace retrofit project at Oakwood Gardens in Lansdale, Pennsylvania. BSC provided design consulting services and pre- and post-retrofit evaluation, testing, and data monitoring.The existing condition was a vented crawlspace with an un-insulated floor between the crawlspace and the dwelling units above. The crawlspace was therefore a critically weak link in the building enclosure and was ripe for improvement. Saving energy was the primary interest and goal, but the greatest challenge in this un-vented crawlspace retrofit project was working through a crawlspace bulk water intrusion problem caused by inadequate site drainage, window well drainage, foundation wall drainage, and a rising water table during rainy periods.While the un-vented crawlspace retrofit was effective in reducing heat loss, and the majority of the bulk water drainage problems had been resolved, the important finding was that some of the wood joists embedded in masonry pockets behind the brick veneer were showing signs of moisture damage.

affordable housing↗

Simulation-Based Validation of An Open-Source, Scalable Framework for Building Energy Management in Small and Medium-Sized Commercial Buildings

Abstract: Small and medium-sized commercial buildings (SMCBs) represent 94% of U.S. commercial buildings but encounter substantial obstacles in adopting Building Energy Management (BEM) systems. Current approaches exhibit fundamental limitations: vendor-specific API platforms restrict interoperability through proprietary ecosystems; commercial automation software demands extensive technical expertise and licensing costs; open-source IoT solutions lack native support for building automation protocols and semantic models. This paper introduces a configuration-driven web interface framework addressing the gap between smart device advancements and accessible BEM software infrastructure for SMCBs. The framework leverages VOLTTRON middleware integrated with an automated converter that processes unified YAML configurations into heterogeneous system files, reducing required configuration artifacts from six separate files to a single unified specification. The system architecture enables vendor-agnostic operation through BACnet and Modbus protocols while supporting semantic building model integration via automated Brick Schema parsing. Configuration-driven interfaces automatically adapt to diverse HVAC types without custom development. Simulation-based validation using BOPTEST demonstrates automatic interface generation between fan coil and hydronic systems, with the automated converter successfully generating all platform-specific outputs from the single YAML input. The result demonstrates the framework's capability to streamline BEM system deployment through reduced configuration complexity. This work bridges simulation capabilities with operational deployment, demonstrating how virtual testbeds validate generalizable software frameworks for real-world building automation.

Chung, Jihoon [ORNL] (ORCID:0000000184880815)↗

Light Quantity Affects the Regulation of Cell Shape in Fremyella diplosiphon

In some cyanobacteria, the color or prevalent wavelengths of ambient light can impact the protein or pigment composition of the light-harvesting complexes. In some cases, light color or quality impacts cellular morphology. The significance of changes in pigmentation is associated strongly with optimizing light absorption for photosynthesis, whereas the significance of changes in light quality-dependent cellular morphology is less well understood. In natural aquatic environments, light quality and intensity change simultaneously at varying depths of the water column.Thus, we hypothesize that changes in morphology that also have been attributed to differences in the prevalent wavelengths of available light may largely be associated with changes in light intensity. Fremyella diplosiphon shows highly reproducible light-dependent changes in pigmentation and morphology. Under red light (RL), F. diplosiphon cells are blue-green in color, due to the accumulation of high levels of phycocyanin, a RL-absorbing pigment in the light-harvesting complexes or phycobilisomes (PBSs), and the shape of cells are short and rounded. Conversely, under green light (GL), F. diplosiphon cells are red in color due to accumulation of GL-absorbing phycoerythrin in PBSs, and are longer and brick-shaped. GL is enriched at lower depths in the water column, where overall levels of light also are reduced, i.e., to 10% or less of the intensity found at the water surface. We hypothesize that longer cells under low light intensities at increasing depths in the water column, which are generally also enriched in green wavelengths, are associated with greater levels of total photosynthetic pigments in the thylakoid membranes. To test this hypothesis, we grew F. diplosiphon under increasing intensities of GL and observed whether the length of cells diminished due to reduced pressure to maintain larger cells and the associated increased photosynthetic membrane capacity under high light intensity, independent of whether it is light of green wavelengths.

59 BASIC BIOLOGICAL SCIENCES↗

Module-Fluidics: Building Blocks for Spatio-Temporal Microenvironment Control

Generating the desired solute concentration signal in micro-environments is vital to many applications ranging from micromixing to analyzing cellular response to a dynamic microenvironment. We propose a new modular design to generate targeted temporally varying concentration signals in microfluidic systems while minimizing perturbations to the flow field. The modularized design, here referred to as module-fluidics, similar in principle to interlocking toy bricks, is constructed from a combination of two building blocks and allows one to achieve versatility and flexibility in dynamically controlling input concentration. The building blocks are an oscillator and an integrator, and their combination enables the creation of controlled and complex concentration signals, with different user-defined time-scales. We show two basic connection patterns, in-series and in-parallel, to test the generation, integration, sampling and superposition of temporally-varying signals. All such signals can be fully characterized by analytic functions, in analogy with electric circuits, and allow one to perform design and optimization before fabrication. Such modularization offers a versatile and promising platform that allows one to create highly customizable time-dependent concentration inputs which can be targeted to the specific application of interest.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-stress study of bioinspired multifunctional PEDOT:PSS/nanoclay nanocomposites using AFM, SEM and numerical simulation

Bioinspired design has been central in the development of hierarchical nanocomposites. Particularly, the nacre-mimetic brick-and-mortar structure has shown excellent mechanical properties, as well as gas-barrier properties and optical transparency. Along with these intrinsic properties, the layered structure has also been utilized in sensing devices. Here we extend the multifunctionality of nacre-mimetics by designing an optically transparent and electron conductive coating based on PEDOT:PSS and nanoclays Laponite RD and Cloisite Na + . We carry out extensive characterization of the nanocomposite using transmittance spectra (trans-parency), conductive atomic force microscopy (conductivity), contact-resonance force microscopy (mechanical properties), and SEM combined with a variety of stress-strain AFM experiments and AFM numerical simulations (internal structure). We further study the nanoclay’s response to the application of pressure with multifrequency AFM and conductive AFM, whereby increases and decreases in conductivity can occur for the Laponite RD composites. We offer a possible mechanism to explain the changes in conductivity by modeling the coating as a 1-dimensional multibarrier potential for electron transport, and show that conductivity can change when the separation between the barriers changes under the application of pressure, and that the direction of the change depends on the energy of the electrons. We did not observe changes in conductivity under the application of pressure with AFM for the Cloisite Na+ nanocomposite, which has a large platelet size compared with the AFM probe diameter. No pressure-induced changes in conductivity were observed in the clay-free polymer either.

59 BASIC BIOLOGICAL SCIENCES↗

The Atacama Cosmology Telescope: Microwave Intensity and Polarization Maps of the Galactic Center

Herein we present arcminute-resolution intensity and polarization maps of the Galactic center made with the Atacama Cosmology Telescope. The maps cover a 32 deg 2 field at 98, 150, and 224 GHz with |l| ≤ 4°, |b| ≤ 2°. We combine these data with Planck observations at similar frequencies to create coadded maps with increased sensitivity at large angular scales. With the coadded maps, we are able to resolve many known features of the Central Molecular Zone (CMZ) in both total intensity and polarization. We map the orientation of the plane-of-sky component of the Galactic magnetic field inferred from the polarization angle in the CMZ, finding significant changes in morphology in the three frequency bands as the underlying dominant emission mechanism changes from synchrotron to dust emission. Selected Galactic center sources, including Sgr A*, the Brick molecular cloud (G0.253+0.016), the Mouse pulsar wind nebula (G359.23-0.82), and the Tornado supernova remnant candidate (G357.7-0.1), are examined in detail. These data illustrate the potential for leveraging ground-based cosmic microwave background polarization experiments for Galactic science.

79 ASTRONOMY AND ASTROPHYSICS↗

High Contrast Pattern Projection To Enable Background Oriented Schlieren Based Air Leak Detection Through Any Interior Or Exterior Building Surface

Air leakage in buildings wastes an estimated 4 quads of energy per year in the United States. Finding and sealing leakage sites is critical in existing buildings. Previous work has shown that background oriented Schlieren (BOS) imaging can be used to visualize air leakage but requires the leak to exit through a high contrast surface like a brick wall. To remedy this, different techniques of projecting various high contrast patterns on low contrast building surfaces like interior gypsum walls or vinyl siding were investigated. For each technique, the background quality was measured and compared to an ideal printed random dot background. The background quality metrics were correlated with the measured visualization metrics to understand which metrics are most important for maximizing air leak visualization performance. In this work, leakage visualization performance is presented for these various projected backgrounds with an aim to expand the building surfaces suitable for the BOS leak detector.

Jatana, Gurneesh [ORNL] (ORCID:0000000288903225)↗

Extraction and Analysis of Time Series Data from Building Automation Systems Using Large Language Models

Semantic schemas like Haystack 4, Brick and ASHRAE standard 223 enable the structured, standardized, and machine-readable representation of building data, facilitating interoperability, data integration, and advanced analytics. However, extracting information from these models requires specialized expertise in SPARQL and other programming languages, skills that are not commonly found among building professionals. Recent advancements in Large Language Models (LLMs), such as ChatGPT, enable the construction of queries using natural language, making it easier for individuals to interact with these systems in a manner that resembles everyday speech. However, these methods have not yet been tested on building semantic ontologies. This paper introduces a novel workflow and tool for enabling users to ask questions about a specific building's data, using natural language and receive answers automatically generated by GPT-4o. Our approach integrates semantic ontologies with advanced LLM capabilities to automate three critical steps: (1) generating SPARQL queries to retrieve time series references from ontological models, (2) extracting the corresponding time series data from the Building Automation System, and (3) performing computations and visualizations tailored to the user's query. The proposed method simplifies access to BAS data, allowing both domain experts and non-specialists to conduct sophisticated analyses without needing extensive technical knowledge of semantic web technologies. By demonstrating this pipeline, we facilitate more accessible and scalable data-driven decision-making in building operations and management.

Mulayim, Ozan Baris↗