LIQUIDARMOR CM Flashing and Sealant, High Impact Technology Demonstration

Air leakage is responsible for about 1.1 quads of energy or 6% of the total energy used by commercial buildings in the US. Consequently, infiltration and exfiltration are among the largest envelope-related contributors to the heating, ventilation, and air conditioning loads in commercial buildings. New air sealing technologies have recently emerged that aim to improve the performance of air barrier systems by simplifying their installation procedure. LIQUIDARMORTM CM Flashing and Sealant is an example of these new advanced material technologies. This technology is a spray-applied sealant and liquid flashing and can span gaps that are up to ¼ in. wide without a supporting material. ORNL verified the performance of LIQUIDARMORTM CM with field tests and energy simulations from a building in which LIQUIDARMORTM CM was one of components of the air barrier system. The Homeland Security Training Center (HTC) at the College of DuPage in Glen Ellyn, IL, served as the demonstration site. Blower door test results show the average air leakage rate in the demonstration site to be 0.15 cfm/ft2 at 1.57 psf, or 63% lower than the 0.4 cfm at 1.57 psf specified in the 2015 International Energy Conservation Code (IECC). According to simulation results, HTC lowered its annual heating and cooling cost by about $3,000 or 9% compared to a similar building that lacked an air barrier system. This demonstration project serves as an example of the level of building envelope airtightness that can be achieved by using air barrier materials that are properly installed, and illustrates the energy and financial savings that such an airtight envelope could attain.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance of a multifunctional PV/T hybrid solar window

A building-integrated multifunctional PV/T solar window has been developed and evaluated. It is constructed of PV cells laminated on solar absorbers placed in a window behind the glazing. To reduce the cost of the solar electricity, tiltable reflectors have been introduced in the construction to focus radiation onto the solar cells. The reflectors render the possibility of controlling the amount of radiation transmitted into the building. The insulated reflectors also reduce the thermal losses through the window. A model for simulation of the electric and hot water production was developed. The model can perform yearly energy simulations where different features such as shading of the cells or effects of the glazing can be included or excluded. The simulation can be run with the reflectors in an active, up right, position or in a passive, horizontal, position. The simulation program was calibrated against measurements on a prototype solar window placed in Lund in the south of Sweden and against a solar window built into a single family house, Solgaarden, in Aelvkarleoe in the central part of Sweden. The results from the simulation shows that the solar window annually produces about 35% more electric energy per unit cell area compared to a vertical flat PV module. (author)

14 SOLAR ENERGY↗

Large-scale simulation-based parametric analysis of an optimal precooling strategy for demand flexibility in a commercial office building

Achieving success with grid-interactive efficient buildings (GEBs) is closely tied to the utilization of flexible loads. A valuable strategy involves the implementation of precooling techniques before high-demand events, such as peak hours, by adjusting zone air temperature setpoints. This leads to a reduction in thermal loads and peak electricity demand during these times, as the building’s thermal mass stores and subsequently releases thermal energy. However, the effectiveness of the pre-cooling optimization is highly contingent on specific conditions such as building thermal properties, weather conditions, utility rate structure, HVAC equipment sizing, etc. Therefore, investigating the impacts of these condition-specific factors is crucial, especially when considering precooling strategies that utilize thermal mass in commercial buildings. In this paper, we first devised a novel heuristic control approach that incorporates parameterized optimal precooling thermostat schedules to enhance demand flexibility in a commercial office building. Subsequently, we conducted a thorough performance evaluation of this control strategy. Here, the optimal thermostat schedule was parameterized using three optimization variables: the precooling start time, the precooling end time, and the precooling temperature setpoint. Utilizing the DOE medium-sized office building as the virtual testbed, we showed that the parameterized schedule effectively approximates model predictive control and requires drastically reduced computational overhead. In addition, we investigated the impact of different influencing factors on the optimal precooling strategy. These factors include building thermal mass, outdoor air conditions, and energy price profiles. Using high-performance computing, we simulated a total of 225 scenarios, consisting of three levels of thermal mass, five typical outdoor air temperature profiles, and fifteen time-of-use price plans. The results demonstrate that optimal thermostat scheduling could save substantial energy cost in medium-sized office buildings with heavy thermal mass but with some energy penalty. Although the potential for cost savings is lower in buildings with low and medium thermal mass, the energy penalty remains consistent in all three thermal mass scenarios. The study also highlights the need to account for zone diversity and recognize that a one-size-fits-all-zone setpoint schedule may not be suitable for all zones and can lead to unnecessary energy wastage. Furthermore, the results highlight that while outdoor air conditions play a role in cost and energy performance, the cooling load exerts a more immediate and substantial influence on cost savings in precooling strategies. Although cost savings are comparable under certain conditions with the same cooling load, observed deviations in energy penalty indicate potential disparities in the efficiency of the HVAC system during the load-shifting process. In addition, the duration of peak pricing and the ratio between peak and off-peak times exhibit clear correlations with cost savings and energy consumption, aligning with intuitive expectations. These findings offer valuable insights for optimizing precooling strategies in office buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A suite of benchmark and challenge problems for enhanced geothermal systems

A diverse suite of numerical simulators is currently being applied to predict or understand the performance of enhanced geothermal systems (EGS). To build confidence and identify critical development needs for these analytical tools, the United States Department of Energy, Geothermal Technologies Office sponsored a Code Comparison Study (GTO-CCS), with participants from universities, industry, and national laboratories. A principal objective for the study was to create a community forum for improvement and verification of numerical simulators for EGS modeling. Teams participating in the study were those representing U.S. national laboratories, universities, and industries, and each team brought unique numerical simulation capabilities to bear on the problems. Two classes of problems were developed during the study, benchmark problems and challenge problems. The benchmark problems were structured to test the ability of the collection of numerical simulators to solve various combinations of coupled thermal, hydrologic, geomechanical, and geochemical processes. This class of problems was strictly defined in terms of properties, driving forces, initial conditions, and boundary conditions. The challenge problems were based on the enhanced geothermal systems research conducted at Fenton Hill, near Los Alamos, New Mexico, between 1974 and 1995. The problems involved two phases of research, stimulation, development, and circulation in two separate reservoirs. The challenge problems had specific questions to be answered via numerical simulation in three topical areas: (1) reservoir creation/stimulation, (2) reactive and passive transport, and (3) thermal recovery. Whereas the benchmark class of problems were designed to test capabilities for modeling coupled processes under strictly specified conditions, the stated objective for the challenge class of problems was to demonstrate what new understanding of the Fenton Hill experiments could be realized via the application of modern numerical simulation tools by recognized expert practitioners. Lastly, we present the suite of benchmark and challenge problems developed for the GTO-CCS, providing problem descriptions and sample solutions.

15 GEOTHERMAL ENERGY↗

2011 EnergyValue Housing Award Report

This report details the simulation tool(s) and energy modeling methodology followed in making the energy efficiency estimates, and documents the estimated performance of the EVHA award-winning houses in comparison with the Building America Benchmark and the associated House Simulation Protocols. A summary of each building and its features is included with a brief description of the project and the judges’ comments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Computational Investigation of Melt Pool Process Dynamics and Pore Formation in Laser Powder Bed Fusion

In the laser powder bed fusion additive manufacturing process, the presence of porosity may result in cracks and significantly affects the part performance. A comprehensive understanding of the melt pool process dynamics and porosity evolution can help to improve build quality. In this study, a novel multi-physics computational fluid dynamics (CFD) model has been applied to investigate the fluid dynamics in melt pools and resultant pore defects. To accurately capture the melting and solidification process, major process physics, such as the surface tension, evaporation as well as laser multi-reflection, have been considered in the model. A discrete element method is utilized to model the generation of powder spreading upon build plate by additional numerical simulations. Multiple single track experiments have been performed to obtain the melt pool shape and cross-sectional dimension information. The predicted melt pool dimensions were found to have a reasonable agreement with experimental measurements, e.g., the errors are in the range of 1.3 to 10.6% for melt pool width, while they are between 1.4 and 15.9% for melt depth. Pores are captured by both CFD simulation and x-ray computed tomography measurement for the case with a laser power of 350 W and laser speed of 100 mm/s. The formation of keyholes maybe related to the melt pool front wall angle, and it is found that the front wall angle increases with the increase in laser line energy density. In addition, a larger laser power or smaller scanning speed can help to generate keyhole-induced pores; they also contribute to produce larger sized pores.

36 MATERIALS SCIENCE↗

Towards Digital and Performance-Based Supervisory HVAC Control Delivery

Upgrading supervisory HVAC control in commercial buildings is one of the most attractive decarbonization tools at our disposal. Modern controls are software programs and can in theory be deployed at scale and with a low up-front carbon "pulse". In practice, however, control delivery is a disjointed and inefficient process, dominated by manual handoffs of imprecise English language documents. A particularly high barrier exists between control implementation and building energy modeling (BEM) which results in control sequences typically not being tested for correctness or performance before implementation. Together with industry partners, DOE and the national labs are developing an ecosystem of tools and standards that can support fully digital performance-based control delivery workflows. This paper describes this ecosystem, which consists of three mutually supportive efforts. Semantic models of buildings and their systems enable automatic configuration and installation of control software. Platform-neutral control descriptions separate control algorithms from control platforms and enable the creation of libraries of reference control implementations. Dynamic whole-building energy-control simulation that can execute physically realistic control sequences makes it possible to test and evaluate the performance of control sequences and then directly compile them for installation and execution in control systems. In addition to digitizing and streamlining project-level control delivery, these standards and related software support benchmarking of control algorithms, both rule-based and optimization-based, and help to both advance the state of the art and to implement ratings and programs that encourage the adoption of high-performance control.

building controls↗

WASTE SOLIDIFICATION BUILDING BENCH SCALE HIGH ACTIVITY WASTE SIMULANT VARIABILITY STUDY FY2008

The primary objective of this task was to perform a variability study of the high activity waste (HAW) acidic feed to determine the impact of feed variability on the quality of the final grout and on the mixability of the salt solution into the dry powders. The HAW acidic feeds were processed through the neutralization/pH process, targeting a final pH of 12. These fluids were then blended with the dry materials to make the final waste forms. A secondary objective was to determine if elemental substitution for cost prohibitive or toxic elements in the simulant affects the mixing response, thus providing a more economical simulant for use in full scale tests. Though not an objective, the HAW simulant used in the full scale tests was also tested and compared to the results from this task. A statistically designed test matrix was developed based on the maximum molarity inputs used to make the acidic solutions. The maximum molarity inputs were: 7.39 HNO{sub 3}, 0.11618 gallium, 0.5423 silver, and 1.1032 'other' metals based on their NO{sub 3}{sup -} contribution. Substitution of the elements aluminum for gallium and copper for silver was also considered in this test matrix, resulting in a total of 40 tests. During the NaOH addition, the neutralization/pH adjustment process was controlled to a maximum temperature of 60 C. The neutralized/pH adjusted simulants were blended with Portland cement and zircon flour at a water to cement mass ratio of 0.30. The mass ratio of zircon flour to Portland cement was 1/12. The grout was made using a Hobart N-50 mixer running at low speed for two minutes to incorporate and properly wet the dry solids with liquid and at medium speed for five minutes for mixing. The resulting fresh grout was measured for three consecutive yield stress measurements. The cured grout was measured for set, bleed, and density. Given the conditions of preparing the grout in this task, all of the grouts were visually well mixed prior to preparing the grouts for measurements. All of the cured grouts were measured for bleed and set. All of the cured grouts satisfied the bleed and set requirements, where no bleed water was observed on any of the grout samples after one day and all had set within 3 days of curing. This data indicates, for a well mixed product, bleed and set requirement are satisfied for the range of acidic feeds tested in this task. The yield stress measurements provide both an indication on the mixability of the salt solution with dry materials and an indication of how quickly the grout is starting to form structure. The inability to properly mix these two streams into a well mixed grout product will lead to a non-homogeneous mixture that will impact product quality. Product quality issues could be unmixed regions of dry material and hot spots having high concentrations of americium 241. Mixes that were more difficult to incorporate typically resulted in grouts with higher yield stresses. The mixability from these tests will provide Waste Solidification Building (WSB) an indication of which grouts will be more challenging to mix. The first yield stress measurements were statistically compared to a list of variables, specifically the batched chemicals used to make the acidic solutions. The first yield stress was also compared to the physical properties of the acidic solutions, physical and pH properties of the neutralized/pH adjusted solutions, and chemical and physical properties of the grout.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A prototype cooling blanket for mitigating occupant overheating risk in a hot indoor environment: Modeling and assessments

Conventional ways of cooling a room or an entire house for occupant thermal comfort during summer consume a significant amount of energy and are vulnerable to overheating risk during power outages that lead to loss of cooling system operations. This study investigates a low-power cooling blanket, as a Personal Cooling System (PCS), that covers the upper human body for direct cooling during a five-day heat wave in a single-family house. A modeling framework is developed for evaluating the thermal and energy performance of the cooling blanket, which builds upon the co-simulation of three models: a house energy model, a personal thermal comfort model, and a cooling blanket model. Simulation results show that under the power outage scenario, the cooling blanket can greatly reduce the occupant heat stress with a reduction of daily hours of exceedance (discomfort hours defined as TSV>2) by up to 17.2 h (a 95.3 % improvement from the baseline power outage without the blanket). The cooling blanket, equipped with an innovative electrocaloric heat pump (COP as high as 10.1) consumes 6.31 W and can be operated by a portable battery for several days. The cooling blanket consumes only 0.28 % of the electricity of a central air-conditioning system running to provide cooling for the whole house during the five-day heatwave period. The findings justify further research of electrocaloric wearable PCS as low-power effective cooling to ensure thermal survivability of occupants during extreme indoor environments.

Electrocaloric heat pump↗

Technical Subtopic 2.1: Modeling Variable Refrigerant Flow Heat Pump and Heat Recovery Equipment in EnergyPlus

The University of Central Florida/Florida Solar Energy Center, in cooperation with the Electric Power Research Institute and several variable-refrigerant-flow heat pump (VRF HP) manufacturers, provided a detailed computer model for a VRF HP system in the United States Department of Energy’s (U.S. DOE) EnergyPlus™ building energy simulation tool. Detailed laboratory testing and field demonstrations were performed to measure equipment performance and compare this performance to both the manufacturer’s data and that predicted by the use of this new model through computer simulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NREL's OpenStudio Helps Design More Efficient Buildings (Fact Sheet)

The National Renewable Energy Laboratory (NREL) has created the OpenStudio software platform that makes it easier for architects and engineers to evaluate building energy efficiency measures throughout the design process. OpenStudio makes energy modeling more accessible and affordable, helping professionals to design structures with lower utility bills and less carbon emissions, resulting in a healthier environment. OpenStudio includes a user-friendly application suite that makes the U.S. Department of Energy's EnergyPlus and Radiance simulation engines easier to use for whole building energy and daylighting performance analysis. OpenStudio is freely available and runs on Windows, Mac, and Linux operating systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Third-Year Report of the Atmosphere to Electrons Mesoscale-to-Microscale Coupling Project

The goal of the mesoscale-to-microscale coupling (MMC) project is to build new high-performance-computing-based multiscale wind-plant simulation tools that couple a broad range of scales to enable the optimization of wind plants to ensure the efficient, reliable production and integration of future wind-generated electricity. To meet this goal, the project seeks to create, assess, and validate state-of-the-science atmospheric simulation methodologies to incorporate important mesoscale flow characteristics into microscale wind-plant simulations.

17 WIND ENERGY↗

Report of the Atmosphere to Electrons Mesoscale-to-Microscale Coupling Project (FY 2018)

The goal of the Mesoscale-to-Microscale Coupling (MMC) project is to build new high-performance-computing-based multiscale wind-plant simulation tools that couple a broad range of scales to enable the optimization of wind plants to ensure the efficient, reliable production and integration of future wind-generated electricity. To meet this goal, the project seeks to create, assess, and validate state-of-the-science atmospheric simulation methodologies to incorporate important mesoscale flow characteristics into microscale wind-plant simulations.

17 WIND ENERGY↗

Artificial Intelligence/Deep Learning FRNN Software for Prediction & Real-Time Control of DIII-D Plasma Control System (PCS)

This collaborative project integrated an improved version of the Artificial Intelligence/Deep Learning FRNN prediction and control software into the real-time DIII-D PCS (plasma control system). A key AI/DL software challenge is to build a modern high-performance computing (HPC) enabled “synthetic plasma simulator” capable of carrying out HPC-driven real-time plasma control applications. This involves development of a deep learning framework to train the surrogate model for a first-principles-based instability analysis simulator (“SGTC”) derived from the global gyrokinetic code GTC. The role of SGTC is to provide accurate and detailed plasma instability information from a real-time AI-based simulator capability to complement the deep learning prediction and control from experimentally-measured signals, such as ECE Imaging, supplemented by synthetic SGTC-ECEI.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using Models to Provide Predicted Ranges for Building-Human Interfaces: Preprint

Most building energy consumption dashboards provide only a snapshot of building performance; whereas some provide more detailed historic data with which to compare current usage. This paper will discuss the Building Agent(tm) platform, which has been developed and deployed in a campus setting at the National Renewable Energy Laboratory as part of an effort to maintain the aggressive energyperformance achieved in newly constructed office buildings and laboratories. The Building Agent(tm) provides aggregated and coherent access to building data, including electric energy, thermal energy, temperatures, humidity, and lighting levels, and occupant feedback, which are displayed in various manners for visitors, building occupants, facility managers, and researchers. This paper focuseson the development of visualizations for facility managers, or an energy performance assurance role, where metered data are used to generate models that provide live predicted ranges of building performance by end use. These predicted ranges provide simple, visual context for displayed performance data without requiring users to also assess historical information or trends. Several energymodelling techniques were explored including static lookup-based performance targets, reduced-order models derived from historical data using main effect variables such as solar radiance for lighting performance, and integrated energy models using a whole-building energy simulation program.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Interactive Visualization Tool for Large-Scale Building Stock Modeling

Recent advancements in data science and high-performance computing are making it easier to run millions of building simulations, but meaningful visualization of such large datasets remains a challenge. This paper presents a new tool developed to view the results of large-scale OpenStudio simulations of national, regional, or local building stocks. The tool processes millions of simulations to calculate measure savings, utility bills, carbon emissions, primary energy, and cost-effectiveness metrics at a high geographic resolution. Interactive visualizations of the building characteristics, consumption, and measure savings data include proportional symbol maps and histogram plots and can be filtered by any building characteristic.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Interactive Visualization Tool for Large-Scale Building Stock Modeling: Preprint

Recent advancements in data science and high-performance computing are making it easier to run millions of building simulations, but meaningful visualization of such large datasets remains a challenge. This paper presents a new tool developed to view the results of large-scale OpenStudio simulations of national, regional, or local building stocks. The tool processes millions of simulations to calculate measure savings, utility bills, carbon emissions, primary energy, and cost-effectiveness metrics at a high geographic resolution. Interactive visualizations of the building characteristics, consumption, and measure savings data include proportional symbol maps and histogram plots and can be filtered by any building characteristic.

big data↗

BacNet and Analog/Digital Interfaces of the Building Controls Virtual Testbed

This paper gives an overview of recent developments in the Building Controls Virtual Test Bed (BCVTB), a framework for co-simulation and hardware-in-the-loop. First, a general overview of the BCVTB is presented. Second, we describe the BACnet interface, a link which has been implemented to couple BACnet devices to the BCVTB. We present a case study where the interface was used to couple a whole building simulation program to a building control system to assess in real-time the performance of a real building. Third, we present the ADInterfaceMCC, an analog/digital interface that allows a USB-based analog/digital converter to be linked to the BCVTB. In a case study, we show how the link was used to couple the analog/digital converter to a building simulation model for local loop control.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗