Search NASA⌕ Search

SEARCH · Search NASA

Results for “CCD Camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Comparison of profile measurements and TRANSPORT beam envelope predictions along the 80-m LANSCE pRad beamline

Here in this paper we report a comparison between the simulation of beam phase-space and profile distributions with diagnostic measurements. TRANSPORT, a particle transport code, was used for the prediction of a 800MeV proton beam envelope from the end of the linac to the proton radiography (pRad) facility (a total length of 80 meters). The beam profile was measured at key positions along the beamline using wire scanners and gated CCD camera systems. These measurements were compared to their respective points along the simulated beamline. The predicted beam envelope and measured data correspond within expected errors.

47 OTHER INSTRUMENTATION↗

SN 2011dh: DISCOVERY OF A TYPE IIb SUPERNOVA FROM A COMPACT PROGENITOR IN THE NEARBY GALAXY M51

On 2011 May 31 UT a supernova (SN) exploded in the nearby galaxy M51 (the Whirlpool Galaxy). We discovered this event using small telescopes equipped with CCD cameras and also detected it with the Palomar Transient Factory survey, rapidly confirming it to be a Type II SN. Here, we present multi-color ultraviolet through infrared photometry which is used to calculate the bolometric luminosity and a series of spectra. Our early-time observations indicate that SN 2011dh resulted from the explosion of a relatively compact progenitor star. Rapid shock-breakout cooling leads to relatively low temperatures in early-time spectra, compared to explosions of red supergiant stars, as well as a rapid early light curve decline. Optical spectra of SN 2011dh are dominated by H lines out to day 10 after explosion, after which He I lines develop. This SN is likely a member of the cIIb (compact IIb) class, with progenitor radius larger than that of SN 2008ax and smaller than the eIIb (extended IIb) SN 1993J progenitor. Our data imply that the object identified in pre-explosion Hubble Space Telescope images at the SN location is possibly a companion to the progenitor or a blended source, and not the progenitor star itself, as its radius ({approx}10{sup 13} cm) would be highly inconsistent with constraints from our post-explosion spectra.

79 ASTRONOMY AND ASTROPHYSICS↗

X-Ray Imaging and Spectroscopy Mission

The X-Ray Imaging and Spectroscopy Mission (XRISM) is a joint mission between the Japan Aerospace Exploration Agency (JAXA) and the National Aeronautics and Space Administration (NASA) in collaboration with the European Space Agency (ESA). In addition to the three space agencies, universities and research institutes from Japan, North America, and Europe have joined to contribute to developing satellite and onboard instruments, data-processing software, and the scientific observation program. XRISM is the successor to the ASTRO-H (Hitomi) mission, which ended prematurely in 2016. Its primary science goal is to examine astrophysical problems with precise, high-resolution X-ray spectroscopy. XRISM promises to discover new horizons in X-ray astronomy. It carries a 6 × 6 pixelized X-ray microcalorimeter on the focal plane of an X-ray mirror assembly (Resolve) and a co-aligned X-ray CCD camera (Xtend) that covers the same energy band over a large field of view. XRISM utilizes the Hitomi heritage, but all designs were reviewed. The attitude and orbit control system was improved in hardware and software. The spacecraft was launched from the JAXA Tanegashima Space Center on 2023 September 6 (UTC). During the in-orbit commissioning phase, the onboard components were activated. Although the gate valve protecting the Resolve sensor with a thin beryllium X-ray entrance window was not yet opened, scientific observation started in 2024 February with the planned performance verification observation program. The nominal observation program commenced with the following guest observation program beginning in 2024 September.

Astronomy and AstroPhysics↗

Detecting antiferromagnetism of atoms in an optical lattice via optical Bragg scattering

Antiferromagnetism of ultracold fermions in an optical lattice can be detected by Bragg diffraction of light, in analogy to the diffraction of neutrons from solid-state materials. A finite sublattice magnetization will lead to a Bragg peak from the ((1/2)(1/2)(1/2)) crystal plane with an intensity depending on details of the atomic states, the frequency and polarization of the probe beam, the direction and magnitude of the sublattice magnetization, and the finite optical density of the sample. Accounting for these effects we make quantitative predictions about the scattering intensity and find that with experimentally feasible parameters the signal can be readily measured with a CCD camera or a photodiode and used to detect antiferromagnetic order.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Purely spatial coincidences of twin photons in parametric spontaneous down-conversion

We have measured sub-shot-noise quantum correlations of spatial fluctuations in the far-field image of the parametric fluorescence created in a type I {beta}-barium-borate nonlinear crystal, either between opposite angular sectors (nondegenerate configuration) or between opposite pixels (degenerate configuration). Imaging is performed at a very low light level (0.2 photons per pixel) with an electron-multiplying CCD camera, resulting in purely spatial coincidences between single photons when detecting on pixels. Experimental results overcome the standard quantum-limit-shot-noise level without subtraction of the variance of the detection noise. We compare these experimental results with numerical results given by the quantum Green's function method, which is proved to have strong advantages over stochastic simulations.

74 ATOMIC AND MOLECULAR PHYSICS↗

Type-I spontaneous parametric down-conversion with a strongly focused pump

We experimentally study the spatial properties of the field generated by spontaneous parametric down-conversion (SPDC) when the pump laser beam is strongly focused in the nonlinear crystal. Special attention is paid to classical intensity measurements with a CCD camera. We introduce the concept of a classical equivalent source that replicates all the coherence properties of SPDC light and explains all our experimental results. We show that, in contrast with experiments with a well-collimated pump, here both the phase-matching conditions and the position of the focusing plane determine the measured intensity profiles in the image plane of the crystal. The transition from the near-field regime to the far field is investigated. Measurements of two-photon correlations under strong focusing are also presented and the special features thereof are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Striated microdischarges in an asymmetric barrier discharge in argon at atmospheric pressure

The investigation of striated microdischarges in barrier discharges in argon at atmospheric pressure is reported. Microdischarges were investigated by means of electrical measurements correlated with intensified CCD camera imaging. The scaling law theory known from low-pressure glow discharge diagnostics was applied in order to describe and explain this phenomenon. The investigated microdischarge is characterized as a transient atmospheric-pressure glow discharge with a stratified column. It can be described by similarity parameters i/r{approx_equal}0.13 A/cm, pr{approx_equal}5 Torr cm, and 3<{lambda}/r<5 with the current i, pressure p, interval of subsequent striations {lambda}, and radius of the plasma channel r. An attempt to describe the mechanism of creation of a striated structure is given, based on an established model of the spatial electron relaxation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First demonstration of a scintillating xenon bubble chamber for detecting dark matter and coherent elastic neutrino-nucleus scattering

A 30-g xenon bubble chamber, operated at Northwestern University in June and November 2016, has for the first time observed simultaneous bubble nucleation and scintillation by nuclear recoils in a superheated liquid. This chamber is instrumented with a CCD camera for near-IR bubble imaging, a solar-blind photomultiplier tube to detect 175-nm xenon scintillation light, and a piezoelectric acoustic transducer to detect the ultrasonic emission from a growing bubble. The time of nucleation determined from the acoustic signal is used to correlate specific scintillation pulses with bubble-nucleating events. We report on data from this chamber for thermodynamic "Seitz" thresholds from 4.2 to 15.0 keV. The observed single- and multiple-bubble rates when exposed to a $^{252}$Cf neutron source indicate that, for an 8.3-keV thermodynamic threshold, the minimum nuclear recoil energy required to nucleate a bubble is $19\pm6$ keV (1$\sigma$ uncertainty). This is consistent with the observed scintillation spectrum for bubble-nucleating events. We see no evidence for bubble nucleation by gamma rays at any of the thresholds studied, setting a 90% C.L. upper limit of $6.3\times10^{-7}$ bubbles per gamma interaction at a 4.2-keV thermodynamic threshold. This indicates stronger gamma discrimination than in CF$_3$I bubble chambers, supporting the hypothesis that scintillation production suppresses bubble nucleation by electron recoils while nuclear recoils nucleate bubbles as usual. Finally, these measurements establish the noble-liquid bubble chamber as a promising new technology for the detection of weakly interacting massive particle dark matter and coherent elastic neutrino-nucleus scattering.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-throughput full-automatic synchrotron-based tomographic microscopy

At the TOMCAT (TOmographic Microscopy and Coherent rAdiology experimenTs) beamline of the Swiss Light Source with an energy range of 8-45 keV and voxel size from 0.37 {micro}m to 7.4 {micro}m, full tomographic datasets are typically acquired in 5 to 10 min. To exploit the speed of the system and enable high-throughput studies to be performed in a fully automatic manner, a package of automation tools has been developed. The samples are automatically exchanged, aligned, moved to the correct region of interest, and scanned. This task is accomplished through the coordination of Python scripts, a robot-based sample-exchange system, sample positioning motors and a CCD camera. The tools are suited for any samples that can be mounted on a standard SEM stub, and require no specific environmental conditions. Up to 60 samples can be analyzed at a time without user intervention. The throughput of the system is dependent on resolution, energy and sample size, but rates of four samples per hour have been achieved with 0.74 {micro}m voxel size at 17.5 keV. The maximum intervention-free scanning time is theoretically unlimited, and in practice experiments have been running unattended as long as 53 h (the average beam time allocation at TOMCAT is 48 h per user). The system is the first fully automated high-throughput tomography station: mounting samples, finding regions of interest, scanning and reconstructing can be performed without user intervention. The system also includes many features which accelerate and simplify the process of tomographic microscopy.

43 PARTICLE ACCELERATORS↗

Fast x-ray microdiffraction techniques for studying irreversible transformations in materials.

A pair of techniques have been developed for performing time-resolved X-ray microdiffraction on irreversible phase transformations. In one technique capillary optics are used to focus a high-flux broad-spectrum X-ray beam to a 60 {micro}m spot size and a fast pixel array detector is used to achieve temporal resolution of 55 {micro}s. In the second technique the X-rays are focused with Kirkpatrick-Baez mirrors to achieve a spatial resolution better than 10 {micro}m and a fast shutter is used to provide temporal resolution better than 20 {micro}s while recording the diffraction pattern on a (relatively slow) X-ray CCD camera. Example data from experiments are presented where these techniques are used to study self-propagating high-temperature synthesis reactions in metal laminate foils.

43 PARTICLE ACCELERATORS↗

Electron image contrast analysis of mosaicity in rutile nanocrystals using direct electron detection

Direct electron detection provides high detective quantum efficiency, significantly improved point spread function and fast read-out which have revolutionized the field of cryogenic electron microscopy. However, these benefits for high-resolution electron microscopy (HREM) are much less exploited, especially for in situ study where major impacts on crystallographic structural studies could be made. By using direct detection in electron counting mode, rutile nanocrystals have been imaged at high temperature inside an environmental transmission electron microscope. The improvements in image contrast are quantified by comparison with a charge-coupled device (CCD) camera and by image matching with simulations using an automated approach based on template matching. Together, these approaches enable a direct measurement of 3D shape and mosaicity (~1°) of a vacuum-reduced TiO 2 nanocrystal about 50 nm in size. Thus, this work demonstrates the possibility of quantitative HREM image analysis based on direct electron detection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Differential Multiphoton Laser Scanning Microscopy

Multifocal multiphoton laser scanning microscopy (mfMPLSM) in the biological and medical sciences has the potential to become a ubiquitous tool for obtaining high-resolution images at video rates. While current implementations of mfMPLSM achieve very high frame rates, they are limited in their applicability to essentially those biological samples that exhibit little or no scattering. In this paper, we report on a method for mfMPLSM in which whole-field detection with a single detector, rather than detection with a matrix of detectors, such as a charge-coupled device (CCD) camera, is implemented. This advance makes mfMPLSM fully compatible for use in imaging through scattering media. Further, we demonstrate that this method makes it possible to simultaneously obtain multiple images and view differences in excitation parameters in a single scan of the specimen.

47 OTHER INSTRUMENTATION↗

Development of a 100 kV pulse generator for driving an electron scanner used in proton beam profile measurements

The Spallation Neutron Source (SNS) utilizes an electron scanner in the accumulator ring for nondestructive transverse profiling of the proton beam. The electron scanner consists of a high voltage pulse generator driving an electron gun, a medium voltage ramp generator, and a CCD camera. A new high voltage pulse generator that provides negative 100 kV pulses with rise times of less than 200 ns, +/-0.5% flattop of greater than 100 ns has been designed, delivered, and undergone extensive testing. The pulse generator has been operationally verified with the existing control system and simulated loads. Full system testing with the actual electron scanner is planned. This paper details the requirements, design, setup, and test results of the high voltage pulse generator.

Morris, B↗

Fabrication and testing of diamond-machined gratings in ZnSe, GaP, and bismuth germanate for the near infrared and visible

High quality immersion gratings for infrared applications have been demonstrated in silicon and germanium. To extend this technology to shorter wavelengths other materials must be investigated. We selected three materials, zinc selenide, gallium phosphide and bismuth germanate (Bi{sub 4}Ge{sub 3}O{sub 12}), based on high refractive index, good visible transmission and commercial availability in useful sizes. Crystal samples were diamond turned on an ultra-precision lathe to identify preferred cutting directions. Using this information we diamond-flycut test gratings over a range of feed rates to determine the optimal cutting conditions. For both ZnSe and GaP good surface quality was achieved at feed rates up to 1.0 cm/minute using a special compound angle diamond tool with negative rake angles on both cutting surfaces. The surface roughness of the groove facets was about 4 nm. A Zygo interferometer measured grating wavefront errors in reflection. For the ZnSe the RMS error was < {lambda}/20 at 633nm. More extensive testing was performed with a HeNe laser source and a cooled CCD camera. These measurements demonstrated high relative diffraction efficiency (> 80%), low random groove error (2.0 nm rms), and Rowland ghost intensities at < 0.1%. Preliminary tests on bismuth germanate show high tool wear.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design, Assembly, and Testing of the Neutron Imaging Lens for the National Ignition Facility

The National Ignition Facility will begin testing DT fuel capsules yielding greater than 10^13 neutrons during 2010. Neutron imaging is an important diagnostic for understanding capsule behavior. Neutrons are imaged at a scintillator after passing through a pinhole. The pixelated, 160-mm square scintillator is made up of ¼ mm diameter rods 50 mm long. Shielding and distance (28 m) are used to preserve the recording diagnostic hardware. Neutron imaging is light starved. We designed a large nine-element collecting lens to relay as much scintillator light as reasonable onto a 75 mm gated microchannel plate (MCP) intensifier. The image from the intensifier’s phosphor passes through a fiber taper onto a CCD camera for digital storage. Alignment of the pinhole and tilting of the scintillator is performed before the relay lens and MCP can be aligned. Careful tilting of the scintillator is done so that each neutron only passes through one rod (no crosstalk allowed). The 3.2 ns decay time scintillator emits light in the deep blue, requiring special glass materials. The glass within the lens housing weighs 26 lbs, with the largest element being 7.7 inches in diameter. The distance between the scintillator and the MCP is only 27 inches. The scintillator emits light with 0.56 NA and the lens collects light at 0.15 NA. Thus, the MCP collects only 7% of the available light. Baffling the stray light is a major concern in the design of the optics. Glass cost considerations, tolerancing, and alignment of this lens system will be discussed.

47 OTHER INSTRUMENTATION↗

Effects On Beam Alignment Due To Neutron-Irradiated CCD Images At The National Ignition Facility

The 192 laser beams in the National Ignition Facility (NIF) are automatically aligned to the target-chamber center using images obtained through charged coupled device (CCD) cameras. Several of these cameras are in and around the target chamber during an experiment. Current experiments for the National Ignition Campaign are attempting to achieve nuclear fusion. Neutron yields from these high energy fusion shots expose the alignment cameras to neutron radiation. The present work explores modeling and predicting laser alignment performance degradation due to neutron radiation effects, and demonstrates techniques to mitigate performance degradation. Camera performance models have been created based on the measured camera noise from the cumulative single-shot fluence at the camera location. We have found that the effect of the neutron-generated noise for all shots to date have been well within the alignment tolerance of half a pixel, and image processing techniques can be utilized to reduce the effect even further on the beam alignment.

42 ENGINEERING↗

The Dark Energy Survey Data Processing and Calibration System

The Dark Energy Survey (DES) is a 5000 deg2 grizY survey reaching characteristic photometric depths of 24th magnitude (10 sigma) and enabling accurate photometry and morphology of objects ten times fainter than in SDSS. Preparations for DES have included building a dedicated 3 deg2 CCD camera (DECam), upgrading the existing CTIO Blanco 4m telescope and developing a new high performance computing (HPC) enabled data management system (DESDM). The DESDM system will be used for processing, calibrating and serving the DES data. The total data volumes are high (~2PB), and so considerable effort has gone into designing an automated processing and quality control system. Special purpose image detrending and photometric calibration codes have been developed to meet the data quality requirements, while survey astrometric calibration, coaddition and cataloging rely on new extensions of the AstrOmatic codes which now include tools for PSF modeling, PSF homogenization, PSF corrected model fitting cataloging and joint model fitting across multiple input images. The DESDM system has been deployed on dedicated development clusters and HPC systems in the US and Germany. An extensive program of testing with small rapid turn-around and larger campaign simulated datasets has been carried out. The system has also been tested on large real datasets, including Blanco Cosmology Survey data from the Mosaic2 camera. In Fall 2012 the DESDM system will be used for DECam commissioning, and, thereafter, the system will go into full science operations.

79 ASTRONOMY AND ASTROPHYSICS↗

The DosiMap, a new 2D scintillating dosimeter for IMRT quality assurance: Characterization of two Cerenkov discrimination methods

New radiation therapy techniques such as IMRT present significant efficiency due to their highly conformal dose distributions. A consequence of the complexity of their dose distributions (high gradients, small irradiation fields, low dose distribution, ...) is the requirement for better precision quality assurance than in classical radiotherapy in order to compare the conformation of the delivered dose with the planned dose distribution and to guarantee the quality of the treatment. Currently this control is mostly performed by matrices of ionization chambers, diode detectors, dosimetric films, portal imaging, or dosimetric gels. Another approach is scintillation dosimetry, which has been developed in the last 15 years mainly through scintillating fiber devices. Despite having many advantages over other methods it is still at an experimental level for routine dosimetry because the Cerenkov radiation produced under irradiation represents an important stem effect. A new 2D water equivalent scintillating dosimeter, the DosiMap, and two different Cerenkov discrimination methods were developed with the collaboration of the Laboratoire de Physique Corpusculaire of Caen, the Comprehensive Cancer Center Francois Baclesse, and the ELDIM Co., in the frame of the MAESTRO European project. The DosiMap consists of a plastic scintillating sheet placed inside a transparent polystyrene phantom. The light distribution produced under irradiation is recorded by a CCD camera. Our first Cerenkov discrimination technique is subtractive. It uses a chessboard pattern placed in front of the scintillator, which provides a background signal containing only Cerenkov light. Our second discrimination technique is colorimetric. It performs a spectral analysis of the light signal, which allows the unfolding of the Cerenkov radiation and the scintillation. Tests were carried out with our DosiMap prototype and the performances of the two discrimination methods were assessed. The comparison of the dose measurements performed with the DosiMap and with dosimetric films for three different irradiation configurations showed discrepancies smaller than 3.5% for a 2 mm spatial resolution. Two innovative discrimination solutions were demonstrated to separate the scintillation from the Cerenkov radiation. It was also shown that the DosiMap, which is water equivalent, fast, and user friendly, is a very promising tool for radiotherapy quality assurance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗