Search NASA⌕ Search

SEARCH · Search NASA

Results for “CFD results”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Preliminary Thermal-Hydraulic Analysis of the UTA–2 Subcritical Linear Accelerator–Driven System

The National Nuclear Security Administration’s mission includes establishing a reliable supply of 99 Mo without highly enriched uranium. Oak Ridge National Laboratory (ORNL) supports this objective through collaborative research and development with industrial partners. Niowave Inc., a current partner, is currently designing a subcritical linear accelerator-driven system (ADS) and preparing for the US Nuclear Regulatory Commission’s licensing process. Niowave’s system has the potential to efficiently supply medical radioisotopes. The technology includes a superconducting electron accelerator and a pile of both natural and low-enriched uranium (LEU) targets. The process fissions uranium and many valuable isotopes can then be extracted from the targets. Niowave is currently iterating through conceptual and detailed design processes for several system sizes. This report discusses UTA–2, which is at the demonstration stage. UTA–2 will validate numerical modeling results with experimental measurements before progressing to the detailed design of UTA–3, the commercial-sized ADS. The thermal-hydraulic behavior of the UTA–2 core design was numerically investigated using STAR-CCM+, as described in this report. STAR-CCM+, a state-of-the-art computational fluid dynamics (CFD) software that was commercially developed by Siemens, has an extensive user base and a set of validation studies. It is also compliant with the American Society of Mechanical Engineers’ Nuclear Quality Assurance 1 standard. Three cases are investigated in this report. Case 1 quantified the temperature field within the UTA–2 assembly and water tank using only conduction as the method of thermal energy transport. This simplified approach was overly conservative and yielded wetted cladding temperatures above the coolant saturation temperature. In this case, the maximum temperature of the wetted cladding surface of the highest power rod exceeded the saturation temperature of water by 63.8°C. Because of the overly conservative approach taken in Case 1 and its negative subcooled margin, buoyancy-driven natural circulation flow physics were implemented in Case 2. Adding coolant motion significantly distributed the thermal energy of the system through convective heat transfer. This relatively small amount of convective heat transfer significantly reduced system temperatures and increased the subcooled margin from –63.8 to 61.3°C. This margin confirmed that no boiling was expected during normal operation of UTA–2 at 230 W. Case 3 had no additional physics models but considered an overpower event during which the power of each LEU and natural uranium rod was at its respective peak values. This resulted in a study with the total assembly power equal to 176% of the nominal power of 230 W considered in Cases 1 and 2. The resulting natural circulation flows were slightly enhanced. The subcooled margin decreased slightly to 46.3°C, which is still a significant margin to local boiling of the water within the tank. This margin confirmed that no boiling was expected during an abnormal operation of UTA–2 at 406 W.

07 ISOTOPE AND RADIATION SOURCES↗

Experimental evaluation of thermal-fluids performance of Helium-Cooled Flat Plate (HCFP) divertor

Various helium (He)-cooled solid-tungsten (W) divertor concepts have been proposed for long-pulse magnetic fusion energy reactors. Among these concepts, the He-cooled flat plate divertor (HCFP) modules have the largest plasma-facing surface area of ~0.2 m 2 . Simulations have shown that the most recent version of the design can withstand heat fluxes as great as 8 MW/m 2 . Earlier experimental studies of a single shortened HCFP cooling unit with a slot length of 7.6 cm used air at ambient temperature and pressures below 0.6 MPa. Here, we present initial experimental studies of a copper alloy and steel test section modeling a shortened HCFP cooling unit using He at prototypical pressure of 10 MPa, inlet temperatures T i ≤ 200 °C and steady-state incident heat fluxes q" ≤ 1.2 MW/m 2 . Results for Nusselt number Nu as a function of Reynolds number Re were obtained for Re = 1.2×10 4 –3.4×10 4 , and used to develop a Nu(Re) correlation and validate numerical models of the test section using commercial computational fluid dynamics (CFD) software. Simulations with this model are performed to evaluate the effect of the shortened slot. Furthermore, these analyses are used to estimate the thermal-fluids performance of the HCFP under prototypical conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Large Eddy Simulation of Convective Heat Transfer in a Random Pebble Bed Using the Spectral Element Method

The development of fluoride-cooled high-temperature reactors has drastically increased the demand for an in-depth understanding of the heat transfer (HT) in packed beds cooled by liquid salts. The complex flow fields and space-dependent porosity found in a pebble bed require a detailed understanding to ensure the proper cooling of the reactor core during normal and accident conditions. As detailed experimental data are complicated to obtain for these configurations, high-fidelity simulation such as large eddy simulation and direct numerical simulation (DNS) can be employed to create a high-resolution heat transfer numerical database that can assist in addressing industrial-driven issues associated with the heat transfer behavior of fluoride-cooled high-temperature reactors. In this paper, we performed a series of large eddy simulation using computational fluid dynamics (CFD) code NekRS to investigate the heat transfer for a bed of 1741 pebbles. Further, the characteristics of the flow, such as average, rms, and time series of velocity and temperature, have been analyzed. Porous media averages have also been performed. The simulation results show a good agreement between non-conjugate heat transfer and conjugate heat transfer. The generated data will be used to benchmark heat transfer modeling methods and local maxima/minima of heat transfer parameters. It will also be used for supporting convective heat transfer quantification for Kairos Power and benchmarking lower fidelity models.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Large eddy simulation of a pressurized reactive fluid–particle system: single-particle dynamics analysis

Pressurized oxy-combustion (POC) is a promising candidate to reduce carbon emissions in power generation. Designing an effective burner plays a vital role in developing new combustion technologies. Because of the high pressure, the volume fraction of particles in a pressurized oxy-combustor could be higher than that in the conventional combustor, therefore, the particle dynamics in the pressurized vessel need to be evaluated accordingly. The present computational work is to predict the influence of the particle size and particle injection location on the particle trajectory. The Stokes number based on turbulence fluctuation, St, is adopted to evaluate the impact of the gas phase on the particulate phase. A large eddy simulation (LES) with the environment pressure of 15 bar and the thermal input of the fuel particle of 100 kWth has been performed by means of the commercial CFD package. It is shown that that in this pressurized environment St << 1 for the 25 µm particles, St ~ 1 for the 100 µm particles, while for the particles exceeding 200 µm St >> 1. The trajectories of the sampling particles from the LES results support this conclusion: the particles less than 100 µm tend to be uniformly distributed in the space while the particles exceeding 200 µm tend to concentrate in the combustor.

Li, Lei↗

Simulations of biomass pyrolysis using glued-sphere CFD-DEM with 3-D intra-particle models

The shape of biomass particles influences intra-particle heat transfer, particle-particle collisions, interphase momentum, heat transfer, and pyrolysis yield. In this research, the effects of these multi-scale phenomena are captured using a glued-sphere computational fluid dynamic discrete element method (CFD-DEM) with 3-D intra-particle models. The glued-spheres resolved the shapes of particles and intra-particle temperature and species distributions. The implementation was validated using the pyrolysis data of a spherical particle and a cylindrical particle. Then, the influences of biomass shapes and sizes on pyrolysis were investigated. The results revealed the significant influence of surface areas and mass distributions on interphase heat transfer and chemical reactions. The intra-particle heat transfer is neglectable for a Biot number smaller than 0.41. Finally, the pyrolysis of irregularly shaped biomass particles in a fixed bed, fluidized bed, and spouted bed was simulated. Analysis of conversion distributions showed the largest deviations in the fixed bed and the slowest conversion rate in the spouted bed. A good balance between uniform and fast conversion is achieved in the fluidized bed. The multi-scale method proposed in this research provides a tool for the evaluation of large irregular-shaped biomass particle pyrolysis in different types of reactors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Temperature Gas-Cooled Reactors Multiphysics Simulation Demonstration and Code Validation

This study presents a comprehensive benchmarking and verification effort of several thermal-hydraulic and multiphysics capabilities for high-temperature gas-cooled reactor applications. The first part of this effort focuses on the running-in verification of Griffin’s multiphysics capabilities, specifically for simulating the evolution of pebble-bed reactor cores from startup to equilibrium. Since Fiscal Year 2024, improvements and enhancements have been implemented in Griffin, including simplifying the process to specify streamlines and developing the online cross-section generation capability. In the absence of validation data, code-to-code comparisons are conducted with kugelpy, showing good agreement for integral quantities like k-eff predictions and predictions for maximum power density. However, accuracy issues are noted for more detailed quantities like the spatial distribution of fission rate densities which will require further work to address. The second part of this report presents an improved System Analysis Module (SAM) core channel model where the effects of cross flow are considered during the pressurized loss of forced cooling transient, resulting in an improved agreement of the predicted pebble temperature with respect to the predictions from the SAM 2D porous media model. Additionally, the wall channeling effect due to variable porosity at the near wall region of the core is also investigated. Furthermore, to demonstrate Griffin’s online cross-section generation capability, a Multiphysics simulation is performed by coupling Griffin to the SAM core channel model. In the third part of the report, as a part of the Organisation for Economic Co-operation and Development/Nuclear Energy Agency (OECD/NEA) thermal-hydraulic code validation benchmark activity for a high-temperature gas-cooled reactor, the High Temperature Test Facility (HTTF) is investigated first using the NekRS computational fluid dynamics (CFD) code to study the flow mixing phenomenon in the lower plenum of the facility. Then, code-to-code and code-to-data comparisons are performed for Test PG27, which is a pressurized conduction cooldown (PCC) test, using five different codes by six organizations from five countries. The different simulations show good agreements in terms of the general trend but there are differences in some results such as the peak temperatures of different regions and heat removal rate.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Reduced-order CFD modeling of cryogenic hydrogen isotope extrusion for pellet fueling

This study presents a reduced-order model (ROM) for computational fluid dynamics (CFD) simulations of cryogenic hydrogen isotope extrusions, focusing on protium (H₂) and deuterium (D₂) piston extruders. Using a 2D axisymmetric ROM in ANSYS-Polyflow, significant computational savings were achieved (runtime reduced from 9∼24 h to 3∼5 min), with extrusion force discrepancies between the 2D ROM and 3D models being on the order of 1%. Parametric studies identified optimal cutoff shear rates in the viscosity model (0.01/s for H₂ and 0.001/s for D₂), providing recommendations for future simulations. Finally, a comprehensive comparison of ROM results with experimental data was performed across varying geometries, cryogenic materials, temperatures, extrusion lengths, and piston velocities. Predictions at low extrusion temperatures met the objective of providing quick and efficient solutions with an acceptable extrusion force error of approximately 10% or less, validating the effectiveness of the 2D ROM approach. However, at high temperatures closer to the triple point, extrusion force error grows, which necessitates developing an improved model that accounts for temperature effects, e.g. melting. Nevertheless, the findings still represent a significant improvement in efficiency of CFD modeling of cryogenic hydrogenic extrusion. The ROM framework can also be extended to tritium (T2) and screw extruders, which will ultimately provide a fast and effective tool for optimizing pellet injector design for ITER and future reactor systems.

Fan, Joy [ORNL] (ORCID:0000000229751735)↗

Heat Exchanger Intensification Through Powder Processing and Enhanced Design (HIPPED)

High intensity, supercritical CO 2 heat exchangers capable of operating at temperatures between 800 and 1100 ˚C and pressures greater than 80 bar are considered a critical component for high efficiency power generation and a range of next-generation industrial processes. A novel heat exchanger concept was proposed in this project. The proposed concept involved a plate-type architecture with three-dimensional fins, called twisted s-shaped fins, that capitalize on additive manufacturing. Four manufacturing processes were studied to realize the complex envisioned design: press and sinter of metallic powders, directed energy deposition, laser powder bed fusion, and a novel powder bed process involving a photoreactive polymer called SEAM (scalable expeditious additive manufacturing), that later was developed at MSU. The team was able to manufacture subscale heat exchangers using laser powder bed fusion (LPBF) and SEAM. The team settled on using SEAM as a final manufacturing approach due to its very low cost. The SEAM-manufactured heat exchanger, however, when tested under pressure, exhibited leaks and the process still requires further development beyond the timeline of the project. To support the heat exchanger design and testing, the team developed a new high temperature flow loop allowing testing under high temperature and pressure. Computational modeling of the heat exchanger was also performed for the twisted s-shaped fins and the computations were validated with experimental data. The new twisted fins resulted in enhanced heat transfer and reduced pressure drop. To further minimize pressure drop in the plate heat exchanger, the team also developed a simplified model for flow maldistribution in the manifolds, providing a new tool for designers that eliminates the need for complex CFD calculations. A technoeconomic analysis was also developed to contrast SEAM with LPBF, this tool indicated that SEAM is several times less costly and offer significant promises as a rapid low cost additive manufacturing process for metallic systems.

30 DIRECT ENERGY CONVERSION↗

HYDRODYNAMIC ANALYSIS OF MACROALGAE LOCAL MODEL USING COMPUTATIONAL FLUID DYNAMICS

In this article, a local scale, fully nonlinear coupled fluid-structural interaction (FSI) sugar kelp model has been developed using a computational fluid dynamics (CFD) method. In this model, to be consistent with available experimental data, the sugar kelp is approximated as elongated rectangles with smoothed isosceles triangles at the ends and a single kelp model with one end fixed in a channel with constant current model is developed. Several different current speeds are simulated, and the resulting drag forces and calculated drag coefficients are validated by comparison with experimental data from the literature. In a previous study, a global scale model was developed using a computational structural dynamics (CSD) method to simulate macroalgae farming system and guide the system configuration design. In the global scale model, the hydrodynamic forces are calculated using Morison’s equation and the kinematics and dynamics of the sugar kelp are simplified and the group of kelps attached to the long line is modeled as a slender structure with the same length and an effective diameter such that the volumes are consistent with the real physical system. This simplified model matches the weight and buoyancy but adjusting the hydrodynamic properties when the general hydrodynamic coefficients are employed. Therefore, optimal hydrodynamic coefficients used in global scale model were determined to obtain the hydrodynamic force more accurately. The validated local scale model is then be applied to determine the hydrodynamic coefficients of the simplified sugar kelp model for global dynamic analysis.

hydrodynamic modeling, macroalgae, CFD model↗

CFD analysis of a solid pin-fueled small modular fluoride salt-cooled reactor

A computational fluid dynamics (CFD) study is performed for the pre-conceptual solid pin-fueled small modular fluoride salt-cooled reactor developed by the Oak Ridge National Laboratory (ORNL). The solid and fluid regions in a 1/12th section of a fuel assembly are modeled. The solid region includes fuel and non-fuel pins, with heat generation in the active region of the fuel pins. Two different power profiles, uniform and center-peaked, are considered. The FLiBe coolant flows from the bottom to the top of the core, parallel to the bank of fuel and non-fuel pins. The k-ω shear-stress transport (SST) model is chosen as the baseline turbulence model. The effects of grid refinement, inlet turbulence specification, and turbulence models on the temperature and pressure drop predictions are studied. Turbulence model sensitivity is investigated by comparing the results from the k-ω SST model with other two-equation models (k-ω baseline or BSL and k-ε realizable) as well as with anisotropic Reynolds stress transport models (linear pressure-strain and stress-BSL). Here the results show that the choice of turbulence model has a significant impact on the pin temperature and bundle pressure drop predictions. The results from the baseline turbulence model show good agreement between the fuel pin temperatures and bundle pressure drop values predicted using a subchannel model previously developed by the authors of the present study.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Investigation of fuel film formation and soot emissions in a GDI engine during cold-start with Split-injection strategies

This study investigates the impact of fuel-film formation on engine-out soot emissions in a gasoline direct injection (GDI) engine under cold-start conditions. Split-injection strategies were applied by varying the number of injections, injection duration, and total fuel quantity to affect wall wetting and control the average in-cylinder equivalence ratio. A combined experimental and numerical approach was employed to analyze fuel-film deposition, combustion efficiency, and engine-out soot and unburnt hydrocarbons (UHC) emissions. In particular, fuel film distribution estimated by means of non-reacting, 3-D, computational fluid dynamics (CFD) simulations, together with experimentally measured soot data, were used to investigate fuel film formation and its role in soot generation. In the experiments, a skip-fired engine control strategy was applied to mimic the transient nature of engine cold-start operation. The results indicate that, under the same total number of injections, increasing the average in-cylinder equivalence ratio through longer injection durations improves combustion stability, as indicated by the decrease of the coefficient of variation of IMEP n (Net Indicated Mean Effective Pressure) from 6.0 % to 0.6 %. However, this strategy leads to higher soot emissions, which increased by nearly an order of magnitude, primarily due to enhanced wall-film formation. In contrast, increasing the number of injections while maintaining a constant equivalence ratio significantly impacts fuel-film deposition and, consequently, soot emissions, with a fivefold reduction of the measured engine-out soot, decreasing from 3.5 mg to 0.7 mg. A soot-film correlation was developed and achieved a high coefficient of determination (r 2 = 0.95) and was further extended to account for spark timing effects. These findings confirm the effectiveness of split-injection for avoiding wall film formation and soot emissions, and the critical role of fuel film in soot generation, supporting the hypothesis that pool fires play a crucial role in contributing to soot formation under these cold-start conditions. In conclusion, the study also indicates the value of a predictive soot-film correlation for developing cold-start emission control strategies.

Engine Cold-start↗

A Study of Propane Combustion in a Spark-Ignited Cooperative Fuel Research (CFR) Engine

Liquefied petroleum gas (LPG), whose primary composition is propane, is a promising candidate for heavy-duty vehicle applications as a diesel fuel alternative due to its CO 2 reduction potential and high knock resistance. To realize diesel-like efficiencies, spark-ignited LPG engines are proposed to operate near knock-limit over a wide range of operating conditions, which necessitates an investigation of fuel-engine interactions that leads to end-gas autoignition with propane combustion. This work presents both experimental and numerical studies of stoichiometric propane combustion in a sparkignited (SI) cooperative fuel research (CFR) engine. Engine experiments are initially conducted at different compression ratio (CR) values, and the effects of CR on engine combustion are characterized. A three-pressure analysis (TPA) model based on the two-zone combustion concept is developed in GT-Power and validated using test results to estimate in-cylinder wall temperatures, residual gas fraction, etc. This model is further utilized to examine end-gas chemistry by enabling the SI turbulent flame combustion and unburned gas chemical kinetics modules. Finally, a three-dimensional (3D) computational fluid dynamic (CFD) model of the CFR engine is developed in CONVERGE, where the G-equation and SAGE detailed chemical kinetics models are implemented for combustion modeling. Here, a 153 species reduced chemical kinetics mechanism derived from the detailed NUIGMech1.1 mechanism based on the ignition delay and laminar flame speed (LFS) studies is used to generate an LFS lookup table and to describe end-gas autoignition chemistry. Multi-cycle Reynolds-averaged Navier-Stokes (RANS) simulations are then performed for the tested CRs, and the numerical model is shown to be capable of predicting the propane combustion characteristics, particularly the end-gas autoignition behavior.

20 FOSSIL-FUELED POWER PLANTS↗

Comparison of free vortex wake and blade element momentum results against large-eddy simulation results for highly flexible turbines under challenging inflow conditions

Abstract. Throughout wind energy development, there has been a push to increase wind turbine size due to the substantial economic benefits. However, increasing turbine size presents several challenges, both physically and computationally. Modeling large, highly flexible wind turbines requires highly accurate models to capture the complicated aeroelastic response due to large deflections and nonstraight blade geometries. Additionally, the development of floating offshore wind turbines requires modeling techniques that can predict large rotor and tower motion. Free vortex wake methods model such complex physics while remaining computationally tractable to perform key simulations necessary during the turbine design process. Recently, a free vortex wake model – cOnvecting LAgrangian Filaments (OLAF) – was added to the National Renewable Energy Laboratory's engineering tool OpenFAST to allow for the aerodynamic modeling of highly flexible turbines along with the aero-hydro-servo-elastic response capabilities of OpenFAST. In this work, free vortex wake and low-fidelity blade element momentum (BEM) results are compared to high-fidelity actuator-line computational fluid dynamics simulation results via the Simulator fOr Wind Farm Applications (SOWFA) method for a highly flexible downwind turbine for varying yaw misalignment, shear exponent, and turbulence intensity conditions. Through these comparisons, it was found that for all considered quantities of interest, SOWFA, OLAF, and BEM results compare well for steady inflow conditions with no yaw misalignment. For OLAF results, this strong agreement with the SOWFA results was consistent for all yaw misalignment values. The BEM results, however, deviated significantly more from the SOWFA results with increasing absolute yaw misalignment. Differences between OLAF and BEM results were dominated by the yaw misalignment angle, with varying shear exponent and turbulence intensity leading to more subtle differences. Overall, OLAF results were more consistent than BEM results when compared to SOWFA results under challenging inflow conditions.

17 WIND ENERGY↗

Hydrogen Leak Modeling for Development of Smart Distributed Monitoring Under Unintended Releases

Hydrogen is a versatile and clean energy carrier that can be produced from various renewable sources such as wind, solar, and hydropower. Hydrogen has the potential to play a crucial role in decarbonizing industrial processes that are currently reliant on fossil fuels and provide long-duration and/or seasonal energy storage to enable electricity decarbonization. Hydrogen can also be used as a fuel for fuel cell vehicles, providing a zero-emission alternative to traditional internal combustion engines. DOE launched the Hydrogen Energy Earthshot (Hydrogen Shot) in June 2021 to reduce the cost of clean hydrogen by 80% to $1 per 1 kilogram in 1 decade ("1 1 1"). While promising, Hydrogen is highly-flammable, and in the presence of oxygen, it can form explosive mixtures. . Therefore, understanding leak scenarios is essential to evaluate and mitigate the safety risks associated with potential hydrogen leaks. An increased understanding of leak behavior, and having tools to model leaks, can help assess how hydrogen would disperse in different environments, influencing emergency response plans and safety measures, and identify potential issues with materials and design systems that can withstand the challenges posed by hydrogen. Recently, researchers have attempted to study hydrogen leaks for development of risk management strategies. However, the focus has been on closed or semi-closed spaces like storage rooms, vehicles, garages, and fueling stations - all promising locations for future hydrogen infrastructure. In this presentation, the modeling environment extends the span of research further by modeling hydrogen leak in an outdoor, open space. We will present the key challenges with modeling hydrogen leaks in an uncontrollable environment, how they were handled, and how modeling results informed sensor selection and placement. A Hydrogen research facility at the National Renewable Energy Laboratory (NREL) was used as a case study to model hydrogen leaks. In the future, Hydrogen wide area detection methodologies will be developed and tested at this site to monitor for unintended and operational hydrogen releases. The data generated from modeling will be used to develop a predictive model to detect hydrogen leak location based on concentration measured by sensors in this open space. Furthermore, the facility was also chosen because controlled hydrogen releases can be performed. A computational fluid dynamics (CFD) based modeling approach was taken to model hydrogen leak. The full-scale hydrogen facility was modeled with a large ambient domain. The electrolyzer at the facility can produce a controlled release rate of 27 kg-H2/hr. Site-specific atmospheric and weather condition data such as wind direction, wind speed at various altitudes, and temperature were used as inputs to the model. To capture the variability of weather conditions, a subset of the weather conditions experienced during daytime hours without precipitation over the course of three months was generated; using established data clustering techniques, a total of 100 condition sets were chosen. The results show statistical distributions and ranges of hydrogen concentrations at locations throughout the domain. These distributions are compared to experimental data from a constant mass flow, controlled hydrogen release at the facility. The stochastic wind conditions of the release make direct validation difficult, therefore, statistical comparison approaches were used. Wind conditions are found to significantly impact the release behavior, including direction and concentration. Sensor selection and placement is proposed for the facility and is now based on release behavior predicted for the facility given its weather patterns; this is much more informed than without the modeling results. The methodology and analysis procedure can be translated to other facilities using modified geometries and site-specific weather conditions. Hydrogen holds great promise as a renewable energy fuel, but ensuring safety in its production, storage, and use is paramount. Studying potential leak scenarios in an open space will help develop sensors to detect hydrogen on a large spectrum of concentration and eventually build a smart distributed monitoring system.

CFD↗

Investigation of Gas Turbine Internal Cooling Using Supercritical CO 2 —Effect of Surface Roughness and Channel Aspect Ratio

In this paper, an experimental and numerical investigation of internal cooling channels with rib turbulators is presented with sCO 2 as the working fluid at process conditions (pressure-20.7 MPa and temperature up to 150 °C). The effect of channel aspect ratio up to 2:1 on thermal-hydraulic performance is explored in additively manufactured rectangular channels and square channels, both with and without 60 deg ribs on the top and bottom sides. The Wilson-plot method is employed to experimentally measure channel-averaged Nusselt number over a Reynolds number range up to 370,000. The friction factor is calculated from pressure drop and mass flow rate and additionally, the overall thermal performance factor (TPF) is reported. A companion computational fluid dynamics (CFD) simulation is performed for the rib turbulated cooling configurations reported in the experiments using the Reynolds average Navier–Stokes-based turbulence model. The objective of the numerical study is to gain insight into the local heat transfer augmentation in the ribbed channels as a result of varying the aspect ratio, channel configuration (square versus rectangular), operating conditions (Reynolds number) and the surface roughness, an inherent outcome of the additive manufacturing process. Surface roughness is simulated using sand grain roughness height (K S ) calculated from the experimental data, and a comparison is presented with the corresponding channel configuration with varying surface roughness heights starting from smooth surfaces (K S = 0). Experimental results indicate that the heat transfer augmentation is negligible in the rectangular channels with ribs on the long side compared to the square channel. However, it is enhanced by 60% in comparison to placing ribs on the shorter side. The TPF remains constant at around 1 for the entire range of Reynolds numbers consistent with prior work at the National Energy Technology Laboratory (NETL). Here, the simulation results highlight that increased surface roughness can have a favorable considerable influence on Nusselt number and overall thermal performance enhancement.

42 ENGINEERING↗

Aerosol Particle Deposition on a Spent Nuclear Fuel Assembly Spacer Grid

The flow and particle deposition patterns on surfaces in an idealized spacer grid for a 17x17 pressurized water reactor (PWR) assembly in a spent fuel canister are modeled using computational fluid dynamics (CFD) with laminar flow. The effects of gravitational settling, non-Stokesian flow, and particle slip are first rigorously analyzed. From the analysis, non-Stokesian effects and slip may be neglected for the particle sizes and conditions expected in a canister. For particles that do not settle out, a swirling flow pattern at the corners of a spacer grid channel directs particles to the leeward side of the flow vanes where much of the deposition occurs. Particle deposition increases with increasing particle diameter. Deposition also increases with decreasing flow velocity as this provides more time for particles to settle and deposit on the leeward side of the flow vanes. The fraction of particles that are transmitted through a spacer grid is determined as a function of inlet gas velocity and particle diameter by running the CFD calculation for each set of conditions and for each particle diameter. Curve fits of the transmission curve as a function of particle diameter for a specified spacer grid and flow velocity are applied to a lognormal particle mass density function for the inlet particles. The resulting mass density function and aerosol mass fraction that passes through the spacer grid can be determined analytically without resorting to numerical iteration. A sample calculation of the analytical solution is demonstrated for a lognormal particle mass density function.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Numerical Investigation of the Spark Discharge Process in a Crossflow

The present study numerically investigates the spark discharge process under crossflow conditions using a thermal equilibrium plasma solver that fully couples the electromagnetic physics and fluid dynamics in a computational framework. Numerical results are validated by the comparison with experimental data. Here, the spark discharge experiment is performed in a constant volume vessel using an inductive coil ignition system for automotive applications, and the evolution of the spark channel is measured using high-speed imaging. The crossflow in the gap between the spark-plug electrodes is generated by a rotating fan with two different fan speeds, and the flow velocity across the gap is characterized by particle image velocimetry (PIV) measurement. A computational fluid dynamics (CFD) solver is employed to simulate the crossflow and provide the flow field variables (velocity, pressure, temperature) to the plasma solver. The crossflow velocity predicted in the flow simulation agrees well with the PIV data in that the non-uniform velocity profiles at monitoring points are reproduced by the CFD code. With the crossflow initialization in the plasma solver, the simulated spark discharge process from the breakdown to spark discharge matches the experimental data, including the voltage and circuit waveforms and the high-speed images of the spark channel evolution. The stretch of spark channel captured by plasma simulations agrees with the measured data. The plasma simulation reveals that the mean temperature of the spark channel is maintained at 5000 K during the discharge phase, and the temperature varies along the spark channel so that the highest value is obtained at the spark root on the center electrode. Overall, the results presented in this paper are meant to provide valuable information about the properties of the plasma generated by the spark discharge.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enhancing $\phi$-sensitivity of ignition delay times through dilution of fuel-air mixture

The high $\phi$-sensitivity (η) of ignition delay time (τ IDT ) is one of the desirable fuel properties for the high-load extension of advanced compression ignition engine. Recent studies revealed the effectiveness of a high dilution rate (x D ) for enhancing η at the engine-relevant conditions. This study aims to quantify the effect of dilution on the η of isooctane using a combined experiment-simulation approach. The ignition delay of the isooctane/air mixture was measured with an Advanced Fuel Ignition Delay Analyzer (AFIDA) over the temperature range of 623 - 923 K at 10 bar pressure with global $\phi$ = 0.3 - 0.6, with and without 28.6% of additional N 2 dilution. For precise evaluation of experimental η, the facility effect of the AFIDA experiment was characterized with three-dimensional computational fluid dynamics (3-D CFD) simulation. The temperature in the combustion chamber from 3-D CFD indicated a substantial temporal dependency, varying up to ~52 K by charge-cooling of fuel injection and heat transfer from the wall. We introduced the dimensionless number θ(t) for characterizing the temporal profile of chamber temperature. Consideration of the facility effect using θ(t) resulted in better agreement between the experimental ..eta.. and zero-dimensional (0-D) kinetics simulation. The refined η were then further utilized to quantify the effectiveness of dilution to η The extent of η enhancement with dilution strategy was maximized at the low-temperature chemistry regime, increasing η by 77% with a 28.6% dilution rate. Further analysis on the dilution effect was carried out using 0-D kinetics simulation, revealing the critical dimensionless numbers relevant to the effectiveness of dilution to η enhancement. Here, this study is the first experiment-simulation combined research to quantify the effect of dilution on η, facilitating the kinetics model refinement for better reproduction of $\phi$-sensitivity.

33 ADVANCED PROPULSION SYSTEMS↗