Solar concentrating properties of truncated hexagonal, pyramidal and circular cones

The solar concentrating properties of specularly reflecting truncated pyramidal, hexagonal, and circular cones are evaluated. Pyramidal and hexagonal configurations are discussed with reference to the concentration factor as a function of half apex angle and the length of the side over the width, and to the irradiance distribution. Expressions are derived for the concentration factor and the irradiance at the base of a circular cone when the sunlight is incident normal to the aperture and for oblique incidence.

Burkhard, D. G.↗

Performance characteristics of a 1.8 by 3.7 meter Fresnel lens solar concentrator

Line-focusing acrylic Fresnel lenses with application potential in the 200 to 370 C range were analytically and experimentally investigated. The measured solar concentration characteristics of a 1.8 by 3.7 m lens and its utilization in a solar collection mode are presented. A measured peak concentration ratio of 62 with 90 percent of the transmitted energy focused into a 5.0cm width was achieved. A peak concentration of 59 and a 90 percent target width of 4.3 cm were analytically computed. The experimental and analytical lens transmittance was 78 percent and 86 percent, respectively. The lens was also interfaced with a nonevacuated receiver assembly and operated in the collection mode. With a natural oxide absorber tube coating (alpha/epsilon = 0.79/0.10), the measured collection efficiency ranged from 43 percent to 200 C to 34 percent at 260 C. Efficiency improvements to the 40 to 50 percent range can be achieved with second generation lenses and higher performance absorptive coatings.

Hastings, L. J.↗

Test of concentrator solar array model for SEPS

The use of concentrators to improve the performance of solar arrays in deep space was tested in a simulated deep space environment. The results of these tests are presented and discussed. Areas of discussion include cell temperature performance in a low temperature, low illumination environment with and without concentration, concentration ratios, and theoretical analysis versus test results. Tests were conducted on a series/parallel configuration and individual cells.

Huie, H. H.↗

Effects of yttrium, aluminum, and chromium concentrations in bond coatings on the performance of zirconia-yttria thermal barriers

A cyclic furnace study was conducted between 990 - 280 C and 1095 - 280 C to evaluate the effects of yttrium, chromium, and aluminum concentrations in nickel base alloy bond coatings and also the effect of the bond coating thickness on the performance of yttria-stabilized zirconia thermal barrier coatings. The presence and the concentration of yttrium is very critical. Without yttrium, rapid oxidation of Ni-Al, Ni-Cr, and Ni-Cr-Al bond coatings causes zirconia thermal barrier coatings to fail very rapidly. Concentrations of chrominum and aluminum in Ni-Cr-Al-Y bond coating have a very significant effect on the thermal barrier coating life. This effect, however, is not as great as that due to yttrium. Furthermore, the thickness and the thickness uniformity also have a very significant effect on the life of the thermal barrier system.

Stecura, S.↗

Performance characteristics of the electrochemical concentration cell ozonesonde

A large number of electrochemical concentration cell (ECC) ozonesondes were calibrated in relation to a UV photometric absorption ozone instrument prior to using the ozonesondes in atmospheric soundings. The two methods of measuring ozone were in reasonable agreement on the average, but there was considerable variation from one ozonesonde to another. Averaging the individual linear regressions gives an ECC ozone concentration equal to 0 + or - 8 nbar plus (0.96 + or - 0.10) times the concentration determined with the UV instrument, where uncertainties represent 90% confidence limits. Applying individual calibration corrections to atmospheric sounding data reduced the mean difference between Dobson spectrophotometric measurements of total ozone overburdens and corresponding values obtained from ozonesonde data from -8.5 + or - 8.2 to -1.4 + or - 7.3% for a series of measurements carried out in 1977. Corresponding uncorrected and corrected differences averaged 3.2 + or - 9.7 and 1.9 + or - 10.6%, respectively, for soundings carried out in 1976.

Torres, A. L.↗

Estimates of ground-level mercury vapor concentrations from postulated launch-pad accidents of NASA space transportation systems

NASA has considered the use of mercury ion bombardment engines as extra-terrestrial propulsion systems where low thrust must be provided for long periods of time. However, the mercury fuel in these engines may pose a hazard if it is accidentally released to the troposphere. A description is presented of diffusion-model estimates of maximum 10-minute and 24-hour ground-level concentrations that could result from the accidental release of mercury from Titan/Centaur and Space Shuttle/Tug transportation systems. Three types of accidental release modes have been considered in the concentration calculations. For all three modes, the diffusion-model calculations were made for a variety of meteorological conditions in an effort to obtain estimates of the maximum credible concentrations under 'worst-case' conditions.

Dumbauld, R. K.↗

Concentrations of condensation nuclei in the vicinity of jetstream maxima

Ozone and condensation nuclei were measured on March 29, 1977 (and March 30, GMT) from a Sabreliner in a frontal zone south of Denver, Colo. The ozone served as a tracer for stratospheric air and the condensation nuclei as a tracer for tropospheric air. Both the Langer condensation nucleus counter and the Rich-100 counter can be used to measure condensation nucleus concentrations in the vicinity of the tropopause. However, the former counter is more sensitive to low concentrations. The nuclei measured were found to be almost entirely larger than 0.005 micron in radius, consisting of thousands of molecules. The mesostructure of the ozone and condensation nucleus concentrations agreed well with a double structure of the frontal zone that became apparent from a detailed analysis of radiosonde data.

Cadle, R. D.↗

Low cost point focus solar concentrator, phase 1

Design concepts and plans for mass-production facilities and equipment, field installation, and maintenance were developed and used for cost analysis of a pneumatically stabilized plastic film point focus solar concentrator which has potential application in conjunction with Brayton cycle engines or supply of thermal energy. A sub-scale reflector was fabricated and optically tested by laser ray tracing to determine focal deviations of the surface slope and best focal plane. These test data were then used for comparisons with theoretical concentrator performance modeling and predictions of full-scale design performance. Results of the economic study indicate the concentrator design will have low cost when mass-produced and has cost/performance parameters that fall within current Jet Propulsion Laboratory goals.

Source record↗

Line-focus concentrating collector program

The Line-Focus Concentrating Collector Program has emphasized the development and dissemination of concentrating solar technology in which the reflected sunlight is focused onto a linear or line receiver. Although a number of different types of line-focus concentrators were developed, the parabolic trough has gained the widest acceptance and utilization within the industrial and applications sectors. The trough is best applied for application scenarios which require temperatures between 140 and 600 F. Another concept, the bowl, is investigated for applications which may require temperatures in the range between 600 and 1200 F. Current technology emphases are upon the reduction of system installation cost and the implementation of production oriented engineering.

Dugan, V. L.↗

A cellular glass substrate solar concentrator

The design of a second generation point focusing solar concentration is discussed. The design is based on reflective gores fabricated of thin glass mirror bonded continuously to a contoured substrate of cellular glass. The concentrator aperture and structural stiffness was optimized for minimum concentrator cost given the performance requirement of delivering 56 kWth to a 22 cm diameter receiver aperture with a direct normal insolation of 845 watts sq m and an operating wind of 50 kmph. The reflective panel, support structure, drives, foundation and instrumentation and control subsystem designs, optimized for minimum cost, are summarized. The use of cellular glass as a reflective panel substrate material is shown to offer significant weight and cost advantages compared to existing technology materials.

Bedard, R.↗

Temperature and species concentration measurements in a swirl-stabilized combustor

An experimental evaluation of a swirl-stabilized combustor is presented. The combustor is composed of two confined, concentric, swirling jets. The inner jet flow is lean premixed methane and air; the outer flow is air. Combustion is stabilized on a swirl-induced recirculation zone. Mean temperature and mean concentrations of major species are measured throughout the combustor, including the recirculation zone. Fine wire thermocouples are used to measure temperature. A gas chromatograph and a chemi-luminescence analyzer are employed to analyze samples extracted by a water-cooled gas-sampling probe. Results are presented in the form of isotherms and isopleths of species concentration in the combustor for two swirl conditions: co-swirl and counter-swirl. The effects of swirl on the combustion are discussed in light of flame quenching due to rapid dilution and cooling of the reacting inner jet flow by mixing with the outer flow. Evidence for probe induced perturbations of the combustion process is observed.

Oven, M. J.↗

Determination of carrier concentration and compensation microprofiles in GaAs

Simultaneous microprofiling of semiconductor free carrier, donor, and acceptor concentrations was achieved for the first time from the absolute value of the free carrier absorption coefficient and its wavelength dependence determined by IR absorption in a scanning mode. Employing Ge- and Si-doped melt-grown GaAs, striking differences were found between the variations of electron concentration and those of ionized impurity concentrations. These results showed clearly that the electronic characteristics of this material are controlled by amphoteric doping and deviations from stoichiometry rather than by impurity segregation.

Jastrzebski, L.↗

Ice nucleus concentrations measured during the 1975 Florida Area Cumulus Experiment /FACE/

Ice nuclei measurements were made aboard a cloud-base aircraft during the 1975 Florida Area Cumulus Experiment. Two techniques were used to obtain the ice nuclei concentrations; membranes were collected and analyzed using the NCAR membrane development chamber and continuous ice nuclei concentrations were obtained using the NCAR acoustical counter. Results showed that the membrane technique failed to effectively detect ice nuclei in this maritime tropical area. However, the concentrations recorded by the acoustical counter showed natural afternoon diurnal increases which may have ramifications on cloud development and seeding potential within the particular study area.

Wisniewski, J.↗

Flat plate vs. concentrator solar photovoltaic cells - A manufacturing cost analysis

The choice of which photovoltaic system (flat plate or concentrator) to use for utilizing solar cells to generate electricity depends mainly on the cost. A detailed, comparative manufacturing cost analysis of the two types of systems is presented. Several common assumptions, i.e., cell thickness, interest rate, power rate, factory production life, polysilicon cost, and direct labor rate are utilized in this analysis. Process sequences, cost variables, and sensitivity analyses have been studied, and results of the latter show that the most important parameters which determine manufacturing costs are concentration ratio, manufacturing volume, and cell efficiency. The total cost per watt of the flat plate solar cell is $1.45, and that of the concentrator solar cell is $1.85, the higher cost being due to the increased process complexity and material costs.

Granon, L. A.↗

Production of NO2/-/ and N2O by nitrifying bacteria at reduced concentrations of oxygen

The influence of oxygen concentration on the production of NO2(-) and N2O by nitrifying marine bacteria of the genus Nitrosomonas is investigated. Pure cultures of the ammonium-oxiding bacteria isolated from the Western Tropical Atlantic Ocean were grown at oxygen partial pressures from 0.005 to 0.2 atm, and concentrations of N2O in the air above the growth medium and dissolved NO2(-) were determined. Decreasing oxygen concentrations are observed to induce a marked decrease in NO2(-) production rates and increase in N2O evolution, leading to an increase of the relative yield of N2O with respect to NO2(-) from 0.3% to nearly 10%. Similar yields of N2O at atmospheric oxygen levels are found for nitrifying bacteria of the genera Nitrosomonas, Nitrosolobus, Nitrosospira and Nitrosococcus, while nitrite-oxydizing bacteria and a dinoflagellate did not produce detectable quantities of N2O. Results support the view that nitrification is a major source of N2O in the environment.

Goreau, T. J.↗

Concentration of hydrocarbons associated with particles in the shelf waters adjacent to the entrance of Chesapeake Bay

Particulate hydrocarbon concentrations were measured in 94 water samples. The concentrations ranged from below the detection limit ( 0.7 micro-G/L) to 32 micro-g/l. The mean for all samples was 5.6 micro-g/l. Particulate hydrocarbon concentrations are higher in the Bay mouth and lower in the shelf waters adjacent to the entrance of Chesapeake Bay. No coherent particulate hydrocarbon distribution is seen with depth in the water column. The Bay is postulated as one of the possible chronic sources of particulate hydrocarbons for the adjacent shelf waters.

Wade, T. L.↗

Calibration of a turbidity meter for making estimates of total suspended solids concentrations and beam attenuation coefficients in field experiments

Management of water resources such as a reservoir requires using analytical models which describe such parameters as the suspended sediment field. To select or develop an appropriate model requires making many measurements to describe the distribution of this parameter in the water column. One potential method for making those measurements expeditiously is to measure light transmission or turbidity and relate that parameter to total suspended solids concentrations. An instrument which may be used for this purpose was calibrated by generating curves of transmission measurements plotted against measured values of total suspended solids concentrations and beam attenuation coefficients. Results of these experiments indicate that field measurements made with this instrument using curves generated in this study should correlate with total suspended solids concentrations and beam attenuation coefficients in the water column within 20 percent.

Usry, J. W.↗

Compilation of atmospheric gas concentration profiles from 0 to 50 km

A set of 52 atmospheric gas concentration profiles between 0 and 50 km was compiled as a convenient reference data set for calculation of atmospheric infrared absorption or emission signals and for initialization of iterative procedures for retrieval of gas concentrations from measured data. The distributions of volume mixing ratio as a function of altitude generally correspond to typical diurnally averaged, seasonally averaged Northern Hemisphere midlatitude gas concentration profiles. Profiles are given for all gases included in current infrared atmospheric absorption line parameter compilations, and for a number of additional important trace gases.

Smith, M. A. H.↗