At least 361 records · Page 20

Interim Report on Concrete Degradation Mechanisms and Online Monitoring Techniques

The existing nuclear power plants in the United States have initial operating licenses of 40 years, though most of these plants have applied for and received license extensions. As plant structures, systems, and components age, their useful life—considering both structural integrity and performance—is reduced as a result of deterioration of the materials. The research on online monitoring of concrete structures conducted under the Advanced Instrumentation, Information, and Control Systems Technologies Pathway of the Light Water Reactor Sustainability Program at Idaho National Laboratory will develop and demonstrate concrete structures health monitoring capabilities. Assessment and management of aging concrete structures in nuclear plants require a more systematic approach than simple reliance on existing code margins of safety. Therefore, structural health monitoring is required to produce actionable information regarding structural integrity that supports operational and maintenance decisions. Through this research project, several national laboratories and Vanderbilt University propose to develop a framework of research activities for the health monitoring of nuclear power plant concrete structures that includes the integration of four elements—damage modeling, monitoring, data analytics, and uncertainty quantification. This report briefly discusses available techniques and ongoing challenges in each of the four elements of the proposed framework with emphasis on degradation mechanisms and online monitoring techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Simple Demonstration of Concrete Structural Health Monitoring Framework

Assessment and management of aging concrete structures in nuclear power plants require a more systematic approach than simple reliance on existing code margins of safety. Structural health monitoring of concrete structures aims to understand the current health condition of a structure based on heterogeneous measurements to produce high confidence actionable information regarding structural integrity that supports operational and maintenance decisions. This ongoing research project is seeking to develop a probabilistic framework for health diagnosis and prognosis of aging concrete structures in a nuclear power plant subjected to physical, chemical, environment, and mechanical degradation. The proposed framework consists of four elements—damage modeling, monitoring, data analytics, and uncertainty quantification. This report describes a proof-of-concept example on a small concrete slab subjected to a freeze-thaw experiment that explores techniques in each of the four elements of the framework and their integration. An experimental set-up at Vanderbilt University’s Laboratory for Systems Integrity and Reliability is used to research effective combination of full-field techniques that include infrared thermography, digital image correlation, and ultrasonic measurement. The measured data are linked to the probabilistic framework: the thermography, digital image correlation data, and ultrasonic measurement data are used for Bayesian calibration of model parameters, for diagnosis of damage, and for prognosis of future damage. The proof-of-concept demonstration presented in this report highlights the significance of each element of the framework and their integration.

36 MATERIALS SCIENCE↗

Development of Nano-Modified Concrete for Next Generation of Storage Systems

The goal of the research was to develop a superior concrete for the long-term storage of used nuclear fuel by engineering concrete at the nanoscale through the incorporation of nano-sized and nano-structured particles based on enhanced reactivity (not fiber reinforcement). The specific objectives were to determine for nano-modified concrete: 1. The effects of environmental weathering (i.e., wet/dry and ingress of reactive species such as chloride and sulfate from the marine environment or other sources) and exposure to radiation and thermal environments on the structural stability and microstructural evolution of the material; 2. How microstructural and morphological changes from environmental weathering and thermal and radiation damage affect the long-term, macroscale performance of the material; and, 3. Identify formulation envelopes for nanoparticle content and combinations to achieve superior concrete criteria for dry storage systems by integrating and extending existing predictive modeling approaches that couple reactive transport and thermo- chemo- and radiation induced damage. The major findings of this work are summarized as follows. The results are being processed and compiled in manuscripts for peer-reviewed publication. Due to the late access to the gamma irradiation facility, material characterization is continuing. Dispersion/agglomeration of nanoparticles in cement pastes. The dispersion/agglomeration of nanoparticles (NPs) of SiO 2 , TiO 2 , Al 2 O 3 , Fe 2 O 3 , and clay (bentonite and halloysite) in water, with and without polycarboxylate-based high range water reducer (P-HRWR), and in the environment of hydrating cement have been investigated. The intrinsic particle characteristics, surface charge, pH, monovalent and divalent ion concentrations in solution, and modes of interaction of the NPs with P-HRWR influenced the NP behavior in solution.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Enhancements to Concrete Modeling Capabilities in Grizzly 2.0

The Grizzly code has been under development for several years with the goal of modeling aging effects in a variety of nuclear power plant systems, components, and structures. Version 2.0 of Grizzly was recently released, including both major improvements to its probabilistic fracture mechanics capabilities for evaluation of irradiated reactor pressure vessels, as well as multiple improvements to its capability for modeling degradation of concrete structures. This report summarizes recent development in the Grizzly code specific to concrete modeling that are included in this release. Major highlights of this work include the release of much of the concrete modeling capabilities of Grizzly in an open-source code called BlackBear, modernization of the models and documentation of the code, support for including nonlinear mechanical constitutive models, including creep and damage, re-architecting the anisotropic expansion model to allow its use for modeling both expansion due to alkali-silica reaction and radiation-induced volumetric expansion, and developing a preliminary capability for modeling connection of reinforcing bars to a concrete matrix.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Vibration-Based Techniques for Concrete Structural Health Monitoring. Light Water Reactor Sustainability Program report

The objectives of this ongoing research project focus on health monitoring and data analytics of concrete slabs containing reactive aggregates and thus subjected to degradation due to alkali-silica reaction (ASR). A controlled concrete slab with four pockets of reactive aggregates (pure silica, and reactive aggregates from three different quarries) was cast at Vanderbilt University and cured in representative conditions to accelerate degradation due to ASR. A set of four concrete samples were also cast and cured at the University of Alabama for ASR testing. Of these four samples, two slabs contained reactive aggregates while the other two had the non-reactive aggregate counterparts mixed throughout the samples. Four additional slabs were cast and cured at the University of Nebraska- Lincoln. Of these four samples; one contained non-reactive aggregates and no reinforcement, one contained reactive aggregates and no reinforcement, one contained reactive aggregates and rebar reinforcement in one direction, and the last contained reactive aggregates and reinforcement in two directions. Single frequency and dual frequency tests were used on these slabs to locate ASR damage within the specimens containing reactive aggregates. The vibration tests were conducted with different sensor and actuator configurations to facilitate damage detection and localization. The results from the data analysis of the dynamic testing on concrete slabs are discussed in detail in this report. Results for damage localization are dependent on multiple parameters used in the tests. This report investigates different methods of data fusion including voting, raw averaging, damage index averaging, and Bayesian fusion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress on Grizzly Development for Reactor Pressure Vessels and Reinforced Concrete Structures

The Grizzly code has been under development for the U.S. Department of Energy’s Light Water Reactor Sustainability program to provide predictive tools for the evolution of material degradation in critical light water reactor structural components due to long-term exposure to the environmental conditions of normal reactor operation, and for the effects of this degradation on the safety of these components. This development has primarily targeted reactor pressure vessels and reinforced concrete structures. Work performed during Fiscal Year 2019 added important features for both of these types of structures. For probabilistic fracture mechanics analysis of reactor pressure vessels, capabilities were added to account for the effects of warm prestressing and residual stresses, as well as to model crack initiation, growth, and arrest. For modeling microstructure evolution in reactor pressure vessels, a cluster dynamics model for evolution of Mn-Ni-Si phases has been implemented. For modeling degraded reinforced concrete structures, capabilities to consider the combined effects of damage and creep in the concrete constitutive model and model nonlinear behavior of reinforcing bars has been added. These newly-developed features fill important gaps in Grizzly’s feature set for engineering-scale analysis of degraded reactor pressure vessels and reinforced concrete structures. Grizzly development in both of these areas has reached a point where it is ready for extensive testing on relevant engineering problems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Concrete Thermal Energy Storage Enabling Flexible Operation without Coal Plant Cycling

The work described in this report is responsive to the Office of Fossil Energy program “Energy Storage for Fossil Power Generation.” The pilot plant built as a result of this project demonstrated the feasibility and performance of a concrete thermal energy storage (CTES) system integrated with a supercritical coal power plant. The 10 MWh electrical (>25 MWh thermal) CTES unit, developed by Storworks Power, was designed to enable flexible operation of coal plants without cycling damage. The project's key technical achievements showcase a significant advancement in energy storage technology. A modular CTES system using 42 “Bolderblocs” units was successfully designed and constructed at Alabama Power’s Plant Gaston Unit 5, with each block containing embedded stainless-steel coils in specialized, cost-effective high-temperature concrete. The system interfaced seamlessly with the plant's 3500 psig (241 barg), 1000°F (538°C) supercritical steam, demonstrating operational flexibility. Over 86 full cycles, the CTES exhibited rapid charging and discharging capabilities, effectively mimicking steam turbine feed conditions and handling varying load profiles and storage durations. Performance validation confirmed the system's ability to consistently meet design target steam conditions of 75 bar-a and ~400°C for nominal baseline discharge. The concrete material withstood repeated thermal cycling without degradation, validating earlier lab-scale tests. Integration of balance of plant components, including a condensate management system with storage tank and air-cooled condenser, minimized plant interfaces and water consumption. A robust control scheme ensured safe, automated operation across various scenarios. Key learnings from the project were invaluable: 1. Initial concrete drying and commissioning procedures were refined for future deployments, enhancing efficiency in subsequent installations. 2. System flexibility exceeded expectations, with rapid response to changing conditions. 3. Design improvements were identified including optimized insulation and piping that will enhance overall system efficiency in future deployments 4. Full cycle thermal roundtrip efficiencies exceeded 88%. While the roundtrip electrical efficiency was somewhat limited by known challenges using input steam, such constraints may be mitigated by swapping steam for hot air as thermal input. 5. A summary of key performance parameters for the pilot test and predicted performance of a full scale commercial system with specified improvements determined from the pilot are shown in Section 8. The project faced challenges, including COVID-19 delays and host plant availability constraints. However, these were overcome through adaptive planning and execution. The successful management of these obstacles demonstrated the resilience and adaptability of the project team and the robustness of the CTES technology. This successful pilot demonstrates the potential for CTES to enhance coal plant flexibility, supporting grid stability as renewable penetration increases. The validated design and operational data provide a solid foundation for scaling up to utility-scale implementations, potentially transforming how thermal plants operate in evolving energy landscapes. The system's ability to rapidly respond to changing grid conditions while maintaining high efficiency makes it a promising solution for balancing intermittent renewable energy sources. Furthermore, the project highlighted the potential for even greater efficiencies in future iterations. The use of air as an input medium could potentially eliminate the limitations observed with steam input, opening new possibilities for energy storage applications beyond coal plant integration. In conclusion, this pilot project not only achieved its primary goals but also uncovered additional benefits and potential applications of the CTES technology. It represents a significant step forward in addressing the challenges of grid stability and flexibility in an increasingly renewable-driven energy landscape.

01 COAL, LIGNITE, AND PEAT↗

Concrete Property and Radionuclide Migration Tests

The Waste Management Project provides safe, compliant, and cost-effective waste management services for the Hanford Site and the DOE Complex. Part of theses services includes safe disposal of LLW and MLLW at the Hanford Low-Level Waste Burial Grounds (LLBG) in accordance with the requirements listed in DOE Order 435.1, Radioactive Waste Management. To partially satisfy these requirements, a Performance Assessment (PA) analyses were completed and approved. DOE Order 435.1 also requires that continuing data collection be conducted to enhance confidence in the critical assumptions used in these analyses to characterize the operational features of the disposal facility that are relied upon to satisfy the performance objectives identified in the Order. One critical assumption is that concrete will frequently be used as waste form or container material to control and minimize the release of radionuclide constituents in waste into the surrounding environment. Data was collected to (1) quantify radionuclide migration through concrete materials similar to those used to encapsulate waste in the LLBG, (2) measure the properties of the concrete materials, especially those likely to influence radionuclide migration, and (3) quantify the stability of U-bearing solid phases of limited solubility in concrete.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Sustainable and Environmentally Friendly Concrete for Structural Applications

The purpose of this study is to utilize waste products—precipitated calcium carbonate (PCC) and upcycled recycled concrete aggregate (upcycled RCA or UCA)—in civil works projects. To do so, tests must be performed to determine the engineering properties of the materials in which PCC and UCA are sequestered. PCC is a fine to coarse grain waste product generated during the production of sugar from sugar beets. UCA is produced from demolished and returned concrete by the extraction of primarily calcium and alkalinity. The study also includes the use of both PCC and UCA in the same concrete mix design. The test results on PCC alone show that the optimum content to achieve a minimum 28 MPa (4000 psi) compressive strength is 25% and 30%. The corresponding compressive strength of mixes in which conventional aggregate was replaced by UCA is about 48 MPa (7000 psi) to 55 MPa (8000 psi) at the same water: cement ratio (0.44) by weight. The compressive strength of concrete with 25% to 30% cement replaced by PCC and varying aggregates replaced with UCA ranges from 19.3 to 40 MPa (2800 to 5800 psi). Other tests on PCC and UCA include tensile strength of 2 to 3 MPa (293 to 423 psi) and flexural strength of 1.3 to 1.9 MPa (183 to 279 psi). Analytical techniques such as X-ray diffraction (XRD), energy-dispersive X-ray spectrometry (EDX), and scanning electron microscopy (SEM) were used to identify the constituent elements and chemical compounds present in PCC, including calcium carbonate and silica. Based on the test results, the composition of PCC by weight indicates 45.9% calcium, 39.4% oxygen, and 9.2% carbon. Based on the results of this study, we can expect to reduce carbon emissions in the production of cement and aggregates, as well as utilize waste products in the civil engineering field.

42 ENGINEERING↗

Activities in Support of Continuing the Service of Nuclear Power Plant Safety-Related Concrete Structures

Nuclear power plant (NPP) concrete structures are described. In-service inspection and testing requirements in the U.S. are summarized. The license renewal process in the U.S. is outlined and its current status provided. Operating experience related to performance of the concrete structures is presented. Basic components of a program to manage aging of the concrete structures are identified and described: (1) Degradation mechanisms, damage models, and material performance; (2) Assessment and remediation: i.e., component selection, in- service inspection, non-destructive examinations, and remedial actions; and (3) Estimation of performance at present or some future point in time: i.e., application of structural reliability theory to the design and optimization of in-service inspection/maintenance strategies, and determination of the effects of degradation on plant risk. Finally, areas are noted where additional research would be of benefit to aging management of nuclear power plant concrete structures.

codes and standards↗

Development Of Thermodynamic and Kinetic Simulation Tools and Testing Procedures for Enhanced Durability of Concrete Containing Industrial By-Products

This project developed screening tools that enable evaluation of alternative cementitious binders that create concretes to significantly reduce energy and emissions while remaining cost competitive on both initial and long-term costs. The team began with the viewpoint that acceptance of new cementitious binder products has a substantially greater chance of successful implementation when capital investment is not excessive and the end product has customers that have experience and resources to use this. As such, a binder system that is based on portland cement with blended using industrial by-products (alternative cementitious materials) has the potential for dramatic and meaningful impact. The team has focused on developing implementable solutions in specifications and current practice. This however requires three main factors: 1) ability to screen byproducts and alternative materials for success, 2) ability to ‘treat’ materials chemically to enhance kinetics, and 3) ability to provide predictions of performance of both binders and concrete from first principles. The project developed/refined a state of the art and scientifically based screening test for SCM called the pozzolanic reactivity test. The team developed kinetic models to simulate these materials as well as experimental approaches to alter selected reactions. Simulation tools were developed that enable the performance of concrete to be predicted based on the chemistry and reactivity of the cement and alternative SCM. Specifically, this project: • enhanced the kinetic reactivity models for use in multi-scale computational programs that use thermodynamics to predict reaction products. 2 • developed scaling models to extend thermodynamic modeling to link these models with pore structure. This enables strength, transport property, and coupled transport prediction. • developed tools to predict performance of cementitious materials using the pozzolanic reactivity test and chemical composition. The predicted properties are consistent with AASHTO R101 and the CEB-FIP model code and can be measured using associated test procedures. • demonstrated mechanical and fracture based modeling tools that thermodynamic predictions and inputs to predict concrete service life. These results have been used to demonstrate the value of enabling specifications to include ASTM C 595 cement as well ASTM C150 cement. In addition, these products are being used to expedite the evaluation of alternative SCM to aide in determining which materials have potential value and what ‘compositions’ of blended cements merit further investment.

42 ENGINEERING↗

Area Factor Determinations for an Industrial Worker Exposed to a Concrete Slab End-State

The U.S. Department of Energy's (DOE) Savannah River Site (SRS) is decommissioning many of its excess facilities through removal of the facility structures leaving only the concrete-slab foundations in place. Site-specific, risk-based derived concentration guideline levels (DCGLs) for radionuclides have been determined for a future industrial worker potentially exposed to residual contamination on these concrete slabs as described in Jannik. These risk-based DCGLs were estimated for an exposure area of 100 m{sup 2}. During deactivation and decommissioning (D and D) operations at SRS, the need for area factors for larger and smaller contaminated areas arose. This paper compares the area factors determined for an industrial worker exposed to a concrete slab end-state for several radionuclides of concern at SRS with 1) the illustrative area factors provided in MARSSIM, 2) the area correction factors provided in the U.S. Environmental Protection Agency's (EPA) Soil Screening Guidance, and 3) the hot spot criterion for field application provided in the RESRAD User's Manual. The purpose of this site-specific assessment is to determine if any of the recommended area factors provided in the guidance documents could be utilized at SRS for field applications of the industrial worker DCGLs. Results show the area factors that were determined for an SRS industrial worker exposed to concrete slab end-states for the common radionuclides provided in the referenced guidance documents. In addition to the SRS site-specific area factors, the following area factors are provided for comparison: - Illustrative examples of outdoor area dose factors (MARSSIM); - Area correction factors as a function of source area (Soil Screening Guidance). Note: the area correction factors were inverted to correspond to a DCGL area factor. - Recommended area correction factors as a function of source area (Soil Screening Guidance); - Ranges for hot spot multiplication factors (RESRAD). As it can be seen, because the MARSSIM area factors are highly affected by ingestion and inhalation pathways, they do not compare well with the SRS area factors. The Soil Screening Guidance area factors are in general more conservative than the SRS area factors because they are based exclusively on external exposures. The RESRAD multiplication factors (though limited to area less than 25 m{sup 2}), are in general more conservative than the SRS area factors but compare well with them. These are the factors that were recommended for use in SRS D and D projects field applications.

61 RADIATION PROTECTION AND DOSIMETRY↗

Transport properties of self-consolidating concrete

This study reports the findings from an investigation carried out to study the effect of the mixture variations on the durability of medium- and high-strength self-consolidating concrete (SCC). The mixture variations studied include the type of mineral admixtures, such as limestone powder (LSP) and pulverized fuel ash (PFA), and viscosity-modifying admixtures (VMA) for both medium- and high-strength SCC. Air permeability, water permeability, capillary absorption, and chloride diffusivity were used to assess the durability of SCC mixtures in comparison with normal, vibrated concretes. The results showed that SCC mixtures, for medium- and high-strength grades using PFA followed by LSP give lower permeability, properties compared with normal concretes. SCC made with VMA had a higher sorptivity, air permeability, and water permeability compared with other SCC mixtures, which can be attributed to higher water-cement ratio (w/c) and lack of pore filling effect. An in-place migration coefficient was obtained using the in-place ion migration test. This was used to compare the potential diffusivity of different concretes. The results indicated that SCC, for both grades of strength, made with PFA showed much lower diffusivity values in comparison with other mixtures, whereas the SCC mixtures with VMA showed higher diffusivity.

01 COAL, LIGNITE, AND PEAT↗

Geopolymer concretes: a green construction technology rising from the ash

Researchers at Louisiana Tech University have embarked on a multi-year research initiative to develop applications for inorganic polymer concrete, or geopolymer concrete, in the area of civil construction, and to bring solve of these applications to market. One objective was to produce a spray-on coating for use in the harsh environment of wastewater conveyance and treatment facilities. Another project is to establish relationships between fly ash composition and particle size distribution and the mechanical attributes and workability of the resulting geopolymer concrete. A third project is to develop a 'smart' geopolymer concrete whose response to a given electric current can be correlated to the stress level to which the structure is subjected. 1 fig., 6 photos.

01 COAL, LIGNITE, AND PEAT↗

Measurement of the U-235 Content of Concreted Waste Drums

A challenging assay situation recently arose, whereby the fissile (i.e. total plutonium plus U-235) content of a population of 164 historical waste drums containing concrete needed to be measured, to comply with nuclear safety limits for transport to, and interim storage within, an Engineered Drum Store. BIL Solutions Ltd has developed a new methodology for measurement of the U-235 content of these 'concrete' drums, because the approach normally used by the in-situ Drum Monitors was found to be overly pessimistic. Initial investigations indicated significant quantities of uranium were present in these drums (but negligible plutonium), mixed with Np-237 and / or Ra-226. These initial measurements also indicated that the uranium was likely to be depleted in enrichment. The U-235 content was therefore determined by measuring the U-238 mass via the passive coincident neutron emission, and combining this with the U-235 and U-238 isotopic abundances, obtained by analysis of a gamma spectrum. Of the uranium isotopic analysis codes available, the FRAM (Fixed energy, Response function Analysis with Multiple efficiencies) software was selected as being most suitable for this application. A wide gamma-ray energy range is used (i.e. 120 keV to 1200 keV) which was considered more likely to yield results when there is significant attenuation. The software is also user configurable, enabling interferences from the other radionuclides present (i.e. Np-237 and Ra-226) to be accounted for. A series of test measurements were performed with well-characterised uranium sources attenuated by concrete shielding, to gain confidence in the performance of FRAM under such conditions. These test measurements indicated that FRAM was able to correctly determine the enrichment of heavily shielded uranium. The new U-235 measurement methodology was then applied to the population of concrete drums; successfully yielding U-235 results despite the dense waste matrix and significant interference from Np-237 and / or Ra-226. The U-235 mass results obtained were significantly more accurate than those that would have been obtained had the traditional approach (i.e. transmission corrected 186 keV count rate) been used, facilitating safe transport and storage of the drums. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results of detailed analyses performed on boring cores extracted from the concrete floors of the Fukushima Daiichi nuclear power plant reactor buildings

Due to the massive earthquake and tsunami on March 11, 2011, and the following severe accident at the Fukushima Daiichi Nuclear Power Plant, concrete surfaces within the reactor buildings were exposed to radioactive liquid and vapor phase contaminants. In order to clarify the situation of this contamination in the reactor buildings of Units 1, 2 and 3, selected samples were transported to the Fuels Monitoring Facility in the Oarai Engineering Center of JAEA where they were subjected to analyses to determine the surface radionuclide concentrations and to characterize the radionuclide distributions in the samples. In particular, penetration of radiocesium in the surface coatings layer and sub-surface concrete was evaluated. The analysis results indicate that the situation of contamination in the building of Unit 2 was different from others, and the protective surface coatings on the concrete floors provided significant protection against radionuclide penetration. The localized penetration of contamination in the concrete floors was found to be confined within a millimeter of the surface of the coating layer of some millimeters. (authors)

42 ENGINEERING↗

New Project on the Analysis of Contamination Mechanisms of Concrete at the Fukushima Daiichi Nuclear Power Station - 19511

For the decommissioning of a nuclear power station (NPS) after a severe accident, estimation of contamination depth and radioactivity level in concrete is essential. This paper outlines a recently begun project on the analysis of the contamination mechanisms of concrete in the Fukushima Daiichi NPS. For this analysis, data on various parameters are required, such as the materials used in the NPS, the environmental conditions of the exposed concrete, the conditions of exposure during the accident and until decommissioning, and the fundamental transport characteristics of nuclides in concrete. These aspects of this project are illustrated with some examples. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental Study on the Transfer of Cs, Sr, Pu and Water in Concrete for the Estimation of Contamination - 20085

As part of the 'Nuclear Energy Science and Technology and Human Resources Development project- through concentrating wisdom-by MEXT' in Japan, the major results from the second year of a project on the analysis of radionuclide contamination mechanisms of concrete and the estimation of contamination distribution at the Fukushima Daiichi nuclear power station active during 2018-2020 are presented. The transfer of Cs, Sr, Pu, and water through concrete was studied experimentally. In a saturated condition, the clay did not affect the transfer and Cs penetrated much faster than Sr. In the dried condition, clay retarded Cs transfer. Carbonation of the concrete retarded the transfer of Cs and Sr. Pu was expected to be precipitated immediately in a high pH condition of concrete. Water suction depends on the temperature. Further, the detailed mechanism was analyzed by {sup 1}H-NMR. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗