Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Using the Moon to Track MODIS Reflective Solar Bands Calibration Stability

MODIS has 20 reflective solar bands (RSB) in the visible (VIS), near infrared (NIR), and short-wave infrared (SWIR) spectral regions. In addition to instrument on-board calibrators (OBC), lunar observations have been used by both Terra and Aqua MODIS to track their reflective solar bands (RSB) on-orbit calibration stability. On a near monthly basis, lunar observations are scheduled and implemented for each instrument at nearly the same lunar phase angles. A time series of normalized detector responses to the Moon is used to monitor its on-orbit calibration stability. The normalization is applied to correct the differences of lunar viewing geometries and the Sun-Moon-Sensor distances among different lunar observations. Initially, the lunar calibration stability monitoring was only applied to MODIS bands (1-4 and 8-12) that do not saturate while viewing the Moon. As the mission continued, we extended the lunar calibration stability monitoring to other RSB bands (bands 13-16) that contain saturated pixels. For these bands, the calibration stability is monitored by referencing their non-saturated pixels to the matched pixels in a non-saturation band. In this paper, we describe this relative approach and apply it to MODIS regularly scheduled lunar observations. We present lunar trending results for both Terra and Aqua MODIS over their entire missions. Also discussed in the paper are the advantages and limitations of this approach and its potential applications to other earth-observing sensors. Keywords: Terra, Aqua, MODIS, sensor, Moon, calibration, stability

Xiong, Xiaoxiong↗

Test Plan for a Calibration Demonstration System for the Reflected Solar Instrument for the Climate Absolute Radiance and Refractivity Observatory

The Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission addresses the need to observe high-accuracy, long-term climate change trends and to use decadal change observations as the most critical method to determine the accuracy of climate change. One of the major objectives of CLARREO is to advance the accuracy of SI traceable absolute calibration at infrared and reflected solar wavelengths. This advance is required to reach the on-orbit absolute accuracy required to allow climate change observations to survive data gaps while remaining sufficiently accurate to observe climate change to within the uncertainty of the limit of natural variability. While these capabilities exist at NIST in the laboratory, there is a need to demonstrate that it can move successfully from NIST to NASA and/or instrument vendor capabilities for future spaceborne instruments. The current work describes the test plan for the Solar, Lunar for Absolute Reflectance Imaging Spectroradiometer (SOLARIS) which is the calibration demonstration system (CDS) for the reflected solar portion of CLARREO. The goal of the CDS is to allow the testing and evaluation of calibration approaches , alternate design and/or implementation approaches and components for the CLARREO mission. SOLARIS also provides a test-bed for detector technologies, non-linearity determination and uncertainties, and application of future technology developments and suggested spacecraft instrument design modifications. The end result of efforts with the SOLARIS CDS will be an SI-traceable error budget for reflectance retrieval using solar irradiance as a reference and methods for laboratory-based, absolute calibration suitable for climate-quality data collections. The CLARREO mission addresses the need to observe high-accuracy, long-term climate change trends and advance the accuracy of SI traceable absolute calibration. The current work describes the test plan for the SOLARIS which is the calibration demonstration system for the reflected solar portion of CLARREO. SOLARIS provides a test-bed for detector technologies, non-linearity determination and uncertainties, and application of future technology developments and suggested spacecraft instrument design modifications. The end result will be an SI-traceable error budget for reflectance retrieval using solar irradiance as a reference and methods for laboratory-based, absolute calibration suitable for climate-quality data collections.

Thome, Kurtis↗

Overview of Aqua MODIS 10-year On-orbit Calibration and Performance

Since launch in May 2002, Aqua MODIS has successfully operated for nearly 10 years, continuously collecting global datasets for scientific studies of key parameters of the earth's land, ocean, and atmospheric properties and their changes over time. The quality of these geophysical parameters relies on the input quality of sensor calibrated radiances. MODIS observations are made in 36 spectral bands with wavelengths ranging from visible (VIS) to longwave infrared (LWIR). Its reflective solar bands (RSB) are calibrated using data collected from its on-board solar diffuser and regularly scheduled lunar views. The thermal emissive bands (TEB) are calibrated using an on-board blackbody (BB). The changes in the sensor's spectral and spatial characteristics are monitored by an on-board spectroradiometric calibration assembly (SRCA). This paper presents an overview of Aqua MODIS 10-year on-orbit operation and calibration activities, from launch to present, and summarizes its on-orbit radiometric, spectral, and spatial calibration and characterization performance. In addition, it will illustrate and discuss on-orbit changes in sensor characteristics and corrections applied to continuously maintain the sensor level 1B (L1B) data quality, as well as lessons learned that could benefit future calibration efforts.

Xiong, X.↗

Flight Test Results of an Angle of Attack and Angle of Sideslip Calibration Method Using Output-Error Optimization

As part of a joint partnership between the NASA Aviation Safety Program (AvSP) and the University of Tennessee Space Institute (UTSI), research on advanced air data calibration methods has been in progress. This research was initiated to expand a novel pitot-static calibration method that was developed to allow rapid in-flight calibration for the NASA Airborne Subscale Transport Aircraft Research (AirSTAR) facility. This approach uses Global Positioning System (GPS) technology coupled with modern system identification methods that rapidly computes optimal pressure error models over a range of airspeed with defined confidence bounds. Subscale flight tests demonstrated small 2-σ error bounds with significant reduction in test time compared to other methods. Recent UTSI full scale flight tests have shown airspeed calibrations with the same accuracy or better as the Federal Aviation Administration (FAA) accepted GPS 'four-leg' method in a smaller test area and in less time. The current research was motivated by the desire to extend this method for inflight calibration of angle of attack (AOA) and angle of sideslip (AOS) flow vanes. An instrumented Piper Saratoga research aircraft from the UTSI was used to collect the flight test data and evaluate flight test maneuvers. Results showed that the output-error approach produces good results for flow vane calibration. In addition, maneuvers for pitot-static and flow vane calibration can be integrated to enable simultaneous and efficient testing of each system.

Siu, Marie-Michele↗

MODIS Instrument Operation and Calibration Improvements

Terra and Aqua MODIS have successfully operated for over 14 and 12 years since their respective launches in 1999 and 2002. The MODIS on-orbit calibration is performed using a set of on-board calibrators, which include a solar diffuser for calibrating the reflective solar bands (RSB) and a blackbody for the thermal emissive bands (TEB). On-orbit changes in the sensor responses as well as key performance parameters are monitored using the measurements of these on-board calibrators. This paper provides an overview of MODIS on-orbit operation and calibration activities, and instrument long-term performance. It presents a brief summary of the calibration enhancements made in the latest MODIS data collection 6 (C6). Future improvements in the MODIS calibration and their potential applications to the S-NPP VIIRS are also discussed.

Aqua↗

Status of Terra MODIS Operation, Calibration, and Performance

Since launch in December 1999, Terra MODIS has successfully operated for nearly 15 years, making continuous observations. Data products derived from MODIS observations have significantly contributed to a wide range of studies of key geophysical parameters of the earth's eco-system of land, ocean, and atmosphere, and their changes over time. The quality of MODIS data products relies on the dedicated effort to monitor and sustain instrument health and operation, to calibrate and update sensor parameters and properties, and to improve calibration algorithms. MODIS observations are made in 36 spectral bands, covering wavelengths from visible to long-wave infrared. The reflective solar bands (1-19 and 26) are primarily calibrated by a solar diffuser (SD) panel and regularly scheduled lunar observations. The thermal emissive bands (20-25 and 27- 36) calibration is referenced to an on-board blackbody (BB) source. On-orbit changes in the sensor spectral and spatial characteristics are monitored by a spectroradiometric calibration assembly (SRCA). This paper provides an overview of Terra MODIS on-orbit operation and calibration activities and implementation strategies. It presents and summarizes sensor on-orbit performance using nearly 15 years of data from its telemetry, on-board calibrators, and lunar observations. Also discussed in this paper are changes in sensor characteristics, corrections applied to maintain MODIS level 1B (L1B) data quality, and efforts for future improvements.

Terra↗

Impact of the Timing of a SAR Image Acquisition on the Calibration of a Flood Inundation Model

Synthetic Aperture Radar (SAR) data have proven to be a very useful source of information for the calibration of flood inundation models. Previous studies have focused on assigning uncertainties to SAR images in order to improve flood forecast systems (e.g. Giustarini et al. (2015) and Stephens et al. (2012)). This paper investigates whether the timing of a SAR acquisition of a flood has an important impact on the calibration of a flood inundation model. As no suitable time series of SAR data exists, we generate a sequence of consistent SAR images through the use of a synthetic framework. This framework uses two available ERS-2 SAR images of the study area, one taken during the flood event of interest, the second taken during a dry reference period. The obtained synthetic observations at different points in time during the flood event are used to calibrate the flood inundation model. The results of this study indicate that the uncertainty of the roughness parameters is lower when the model is calibrated with an image taken before rather than during or after the flood peak. The results also show that the error on the modeled extent is much lower when the model is calibrated with a pre-flood peak image than when calibrated with a near-flood peak or a post-flood peak image. It is concluded that the timing of the SAR image acquisition of the flood has a clear impact on the model calibration and consequently on the precision of the predicted flood extent.

Flood inundation↗

Landsat-7 ETM+ Radiometric Calibration Status

Now in its 17th year of operation, the Enhanced Thematic Mapper + (ETM+), on board the Landsat-7 satellite, continues to systematically acquire imagery of the Earth to add to the 40+ year archive of Landsat data. Characterization of the ETM+ on-orbit radiometric performance has been on-going since its launch in 1999. The radiometric calibration of the reflective bands is still monitored using on-board calibration devices, though the Pseudo-Invariant Calibration Sites (PICS) method has proven to be an effect tool as well. The calibration gains were updated in April 2013 based primarily on PICS results, which corrected for a change of as much as -0.2%/year degradation in the worst case bands. A new comparison with the SADE database of PICS results indicates no additional degradation in the updated calibration. PICS data are still being tracked though the recent trends are not well understood. The thermal band calibration was updated last in October 2013 based on a continued calibration effort by NASA/Jet Propulsion Lab and Rochester Institute of Technology. The update accounted for a 0.31 W/sq m/ sr/micron bias error. The updated lifetime trend is now stable to within + 0.4K.

Julia A Barsi↗

Optical Modeling and Polarization Calibration for CMB Measurements with Actpol and Advanced Actpol

The Atacama Cosmology Telescope Polarimeter (ACTPol) is a polarization sensitive upgrade to the Atacama Cosmology Telescope, located at an elevation of 5190 m on Cerro Toco in Chile. ACTPol uses transition edge sensor bolometers coupled to orthomode transducers to measure both the temperature and polarization of the Cosmic Microwave Background (CMB). Calibration of the detector angles is a critical step in producing polarization maps of the CMB. Polarization angle offsets in the detector calibration can cause leakage in polarization from E to B modes and induce a spurious signal in the EB and TB cross correlations, which eliminates our ability to measure potential cosmological sources of EB and TB signals, such as cosmic birefringence. We calibrate the ACTPol detector angles by ray tracing the designed detector angle through the entire optical chain to determine the projection of each detector angle on the sky. The distribution of calibrated detector polarization angles are consistent with a global offset angle from zero when compared to the EB-nulling offset angle, the angle required to null the EB cross-correlation power spectrum. We present the optical modeling process. The detector angles can be cross checked through observations of known polarized sources, whether this be a galactic source or a laboratory reference standard. To cross check the ACTPol detector angles, we use a thin film polarization grid placed in front of the receiver of the telescope, between the receiver and the secondary reflector. Making use of a rapidly rotating half-wave plate (HWP) mount we spin the polarizing grid at a constant speed, polarizing and rotating the incoming atmospheric signal. The resulting sinusoidal signal is used to determine the detector angles. The optical modeling calibration was shown to be consistent with a global offset angle of zero when compared to EB nulling in the first ACTPol results and will continue to be a part of our calibration implementation. The first array of detectors for Advanced ACTPol, the next generation upgrade to ACTPol, will be deployed in 2016.We plan to continue using both techniques and compare them to astrophysical source measurements for the Advanced ACTPol polarization calibration.

Koopman, Brian↗

Assessment of MODIS On-Orbit Calibration Using a Deep Convective Cloud Technique

The MODerate Resolution Imaging Spectroradiometer (MODIS) sensors onboard Terra and Aqua satellites are calibrated on-orbit with a solar diffuser (SD) for the reflective solar bands (RSB). The MODIS sensors are operating beyond their designed lifetime and hence present a major challenge to maintain the calibration accuracy. The degradation of the onboard SD is tracked by a solar diffuser stability monitor (SDSM) over a wavelength range from 0.41 to 0.94 micrometers. Therefore, any degradation of the SD beyond 0.94 micrometers cannot be captured by the SDSM. The uncharacterized degradation at wavelengths beyond this limit could adversely affect the Level 1B (L1B) product. To reduce the calibration uncertainties caused by the SD degradation, invariant Earth-scene targets are used to monitor and calibrate the MODIS L1B product. The use of deep convective clouds (DCCs) is one such method and particularly significant for the short-wave infrared (SWIR) bands in assessing their long-term calibration stability. In this study, we use the DCC technique to assess the performance of the Terra and Aqua MODIS Collection-6 L1B for RSB 1 3- 7, and 26, with spectral coverage from 0.47 to 2.13 micrometers. Results show relatively stable trends in Terra and Aqua MODIS reflectance for most bands. Careful attention needs to be paid to Aqua band 1, Terra bands 3 and 26 as their trends are larger than 1% during the study time period. We check the feasibility of using the DCC technique to assess the stability in MODIS bands 17-19. The assessment test on response versus scan angle (RVS) calibration shows substantial trend difference for Aqua band 1between different angles of incidence (AOIs). The DCC technique can be used to improve the RVS calibration in the future.

Mu, Qiaozhen↗

Sixteen Years of Terra MODIS On-Orbit Operation, Calibration, and Performance

Terra MODIS has successfully operated for more than 16 years since its launch in December 1999. From its observations, many science data products have been generated in support of a broad range of research activities and remote sensing applications. Terra MODIS has operated in a number of configurations and experienced a few anomalies, including spacecraft and instrument related events. MODIS collects data in 36 spectral bands that are calibrated regularly by a set of on-board calibrators for their radiometric, spectral, and spatial performance. Periodic lunar observations and long-term radiometric trending over well-characterized ground targets are also used to support sensor on-orbit calibration. Dedicated efforts made by the MODIS Characterization Support Team (MCST) and continuing support from the MODIS Science Team have contributed to the mission success, enabling well-calibrated data products to be continuously generated and routinely delivered to users worldwide. This paper presents an overview of Terra MODIS mission operations, calibration activities, and instrument performance of the past 16 years. It illustrates and describes the results of key sensor performance parameters derived from on-orbit calibration and characterization, such as signal-to-noise ratio (SNR), noise equivalent temperature difference (NEdT), solar diffuser (SD) degradation, changes in sensor responses, center wavelengths, and band-to-band registration (BBR). Also discussed in this paper are the calibration approaches and strategies developed and implemented in support of MODIS Level 1B data production and re-processing, major challenging issues, and lessons learned. (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.

Xiong, X.↗

An Integrated Approach to Weather Radar Calibration and Monitoring Using Ground Clutter and Satellite Comparisons

The stability and accuracy of weather radar reflectivity calibration are imperative for quantitative applications, such as rainfall estimation, severe weather monitoring and nowcasting, and assimilation in numerical weather prediction models. Various radar calibration and monitoring techniques have been developed, but only recently have integrated approaches been proposed, that is, using different calibration techniques in combination. In this paper the following three techniques are used: 1) ground clutter monitoring, 2) comparisons with spaceborne radars, and 3) the self-consistency of polarimetric variables. These techniques are applied to a C-band polarimetric radar (CPOL) located in the Australian tropics since 1998. The ground clutter monitoring technique is applied to each radar volumetric scan and provides a means to reliably detect changes in calibration, relative to a baseline. It is remarkably stable to within a standard deviation of 0.1 dB (decibels). To obtain an absolute calibration value, CPOL observations are compared to spaceborne radars on board TRMM (Tropical Rainfall Measuring Mission) and GPM (Global Precipitation Measurement) using a volume-matching technique. Using an iterative procedure and stable calibration periods identified by the ground echoes technique, we improve the accuracy of this technique to about 1 dB. Finally, we review the self-consistency technique and constrain its assumptions using results from the hybrid TRMM-GPM and ground echo technique. Small changes in the self-consistency parameterization can lead to 5 dB of variation in the reflectivity calibration. We find that the drop-shape model of Brandes et al. with a standard deviation of the canting angle of 12 degrees best matches our dataset.

Louf, Valentin↗

Use of an Internal Mercury-Argon Lamp for the Calibration of Raman Frequency in Large Raman Images of Astromaterials

Raman imaging is an emerging tool for the analysis of meteorites, as it is capable of describing mineralogy, carbon composition/speciation, and crystal orientation all within a petrographic context. Adequately examining the heterogeneous composition of a meteorite, while maintaining low laser powers needed to prevent damage to meteorite mineralogy and organics, often requires the collection of large Raman images with long collection times on the timescale of days. However, the frequency calibration of the Raman instrument/spectrometer drifts on long timescales resulting in low frequency precision for the Raman spectra comprising a large Raman image. This decrease in frequency precision can compromise the analysis of geological markers that can provide important information on a meteorite sample. We examine, in detail, the change in bandwidth and frequency of the Raman bands and Hg-Ar emission lines in our Raman images as a function of time and laboratory temperature. To overcome the drift in calibration, we utilize a commercial WITec Raman instrument with an internal Hg-Ar calibration lamp to individually calibrate each spectrum in the Raman image. Our instrument, known as “Ratatoskr”, uses a beam splitter in place of the customary mirror to facilitate collection of Hg-Ar calibration lines concurrent with Raman spectra. We show that using the internal calibration we can improve the frequency precision for the spectra in our Raman images from ~±0.15 cm(exp -1) to ~±0.05 cm(exp -1) for Raman spectra collected over multiple days. This is important as it improves measurements of mineral chemistry, latent strain, and other features that are dependent upon accurate peak position determination. We also examine the spectral signal-to-noise ratio needed to minimize the frequency error when fitting bands to Gaussian/Lorentzian profiles. We then use our results to suggest a general method for calibrating the frequency of Raman spectra in large Raman images.

Jakubek, Ryan S.↗

Monitoring the Calibration of the DSCOVR EPIC Instrument’s Visible Cchannels Using MODIS and VIIRS as a Reference

The Earth Polychromatic Imaging Camera (EPIC) instrument aboard the Deep Space Climate Observatory (DSCOVR) satellite has a constant unique view of the sunlit disk of the Earth from the Lagrange-1 (L1) point nearly a million miles away from the Earth. Due to EPIC not having any on-board calibration systems, the ten spectral channels of EPIC must be inter-calibrated using vicarious on-orbit methods, such as ray-matching with well-calibrated low Earth orbiting satellites like the Aqua-MODIS and SNPP-VIIRS radiometers. The recently released EPIC version 3 L1B data has greatly enhanced the residual navigation errors found in prior versions, thereby decreasing the calibration uncertainty in the aforementioned ray-matching calibration techniques. The automated navigation correction used by these ray-matching methods for further improving the EPIC geolocation will be compared with a new navigation correction method utilizing optical flow between the EPIC and MODIS/VIIRS images. The DSCOVR satellite went into safe mode on June 27, 2019 due to an anomaly with the satellite’s attitude control system, but operations recommenced on March 2, 2020. The calibration of the EPIC instrument before it went into safe mode and after it resumed will be analyzed in order to investigate any potential calibration shifts or discontinuities caused by the spacecraft anomaly.

Conor Haney↗

ICESat-2 Pointing Calibration and Geolocation Performance

ICESat-2 science requirements are dependent on the accurate real-time pointing control (i.e. geolocation control) and post-processed geolocation knowledge of the laser altimeter surface returns. Pre-launch pointing alignment errors and post-launch pointing alignment variation result in large geolocation errors that must be calibrated on orbit. In addition, the changing sun-orbit geometry causes thermal-mechanical forced laser frame alignment variations at the orbit period and trends from days, weeks and months. Early mission analysis computed precise post-launch laser beam alignment calibration. The alignment calibration was uploaded to the spacecraft and enabled the pointing control performance to achieve 4.4 ± 6.0 m, a significant improvement over the 45 m (1 σ) mission requirement. Laser frame alignment calibrations are used to reduce the alignment bias and time variation, as well as the orbital variation contributions to geolocation knowledge error from 6 m to 1.7 m (1 σ). Relative beam alignment of the six beams is calibrated and shown to contribute between 0.5 ± 0.1 m and 2.4 ± 0.2 m of remaining geolocation knowledge error. Independent geolocation assessment based on comparison to high-resolution digital elevation models agrees well with the calibration geolocation error estimates. The analysis demonstrates the ICESat-2 mission is performing far better than its geolocation knowledge requirement of 6.5 m (1 σ) after the laser frame alignment bias variation and orbital variation calibrations have been applied. Remaining geolocation error is beam dependent and ranges from 2.5 m for beam 6 to 4.4 m for beam 2 (mean + 1 σ).

S. B. Luthcke↗

Planning In-Flight Calibration for XRISM

The XRISM X-ray observatory will fly two advanced instruments, the Resolve high-resolution spectrometer and the Xtend wide-field imager. These instruments, particularly Resolve, pose calibration challenges due to the unprecedented combination of spectral resolution, spectral coverage, and effective area, combined with a need to characterize the imaging fidelity of the full instrument system to realize the mission’s ambitious science goals. We present the status of the XRISM in-flight calibration plan, building on lessons from Hitomi and other X-ray missions. We present a discussion of targets and observing strategies to address the needed calibration measurements, with a focus on developing methodologies to plan a thorough and flexible calibration campaign and provide insight on calibration systematic error. We also discuss observations that exploit Resolve’s spectral resolution to calibrate atomic codes, and cross-calibration between the XRISM instruments and with other observatories.

Eric D Miller↗

ICESat-2 Pointing Calibration and Geolocation Performance

ICESat-2 science requirements are dependent on the accurate real-time pointing control (i.e., geolocation control) and postprocessed geolocation knowledge of the laser altimeter surface returns. Prelaunch pointing alignment errors and postlaunch pointing alignment variation result in large geolocation errors that must be calibrated on orbit. In addition, the changing sun-orbit geometry causes thermal-mechanical forced laser frame alignment variations at the orbit period and trends from days, weeks, and months. Early mission analysis computed precise postlaunch laser beam alignment calibration. The alignment calibration was uploaded to the spacecraft and enabled the pointing control performance to achieve 4.4 ± 6.0 m, a significant improvement over the 45 m (1 σ) mission requirement. Laser frame alignment calibrations are used to reduce the alignment bias and time variation, as well as the orbital variation contributions to geolocation knowledge error from 6 to 1.7 m (1 σ). Relative beam alignment of the six beams is calibrated and shown to contribute between 0.5 ± 0.1 m and 2.4 ± 0.2 m of remaining geolocation knowledge error. Independent geolocation assessment based on comparison to high-resolution digital elevation models agrees well with the calibration geolocation error estimates. The analysis demonstrates the ICESat-2 mission is performing far better than its geolocation knowledge requirement of 6.5 m (1 σ) after the laser frame alignment bias variation and orbital variation calibrations have been applied. Remaining geolocation error is beam dependent and ranges from 2.5 m for beam 6 to 4.4 m for beam 2 (mean + 1 σ).

S B Luthcke↗

Leveraging Pre-storm Soil Moisture Estimates for Enhanced Land Surface Model Calibration in Ungauged Hydrologic Basins

Despite long-standing efforts, hydrologists still lack robust tools for calibrating land surface model (LSM) streamflow estimates within ungauged basins. Using surface soil moisture estimates from the Soil Moisture Active Passive Level 4 Soil Moisture (L4_SM) product, precipitation observations, and streamflow gauge measurements for 617 medium-scale (200-10,000 km2) basins in the contiguous United States, we measure the temporal (Spearman) rank correlation between antecedent (i.e., pre-storm) surface soil moisture (ASM) and the storm-scale runoff coefficient (RC; the fraction of storm-scale precipitation accumulation converted into streamflow). In humid and semi-humid basins, this rank correlation is shown to be sufficiently strong to allow for the substitution of storm-scale RC observations (available only in basins that are both lightly regulated and gauged) with high-quality ASM values (available quasi-globally from L4_SM) in streamflow calibration procedures. Using this principle, we define a new, basin-wise LSM streamflow calibration approach based on L4_SM alone and successfully apply it to identify LSM configurations that produce a high rank correlation with observed RC. However, since the approach cannot detect RC bias, it is less successful in identifying LSM configurations with low mean-absolute error. Plain Text Summary Accurately forecasting the fraction of rainfall that runs off into streams, as opposed to infiltrates into the soil, is critical for flash-flood prediction, water-resource monitoring, and tracking the transport of nutrients from agricultural fields into local waterways. Such forecasting is typically performed by hydrologic models that attempt to represent the physical processes responsible for surface runoff generation. However, to provide accurate streamflow forecasts, these models typically need to be calibrated against actual streamflow observations. This is problematic given the relatively poor, and declining, global availability of stream gauges. This paper presents a novel model calibration strategy that uses soil moisture from remote sensing and numerical modeling in place of streamflow observations during calibration. This transition has significant practical advantages because, unlike streamflow observations, the soil moisture data are continuously available across space. Our results demonstrate that this new approach can significantly improve hydrologic models within humid and semi-humid basins lacking sufficient ground-based instrumentation for traditional streamflow calibration.

hydrologic models↗