Search NASA⌕ Search

SEARCH · Search NASA

Results for “CdTe:I”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Development of an operando characterization stage for multi-modal synchrotron x-ray experiments

It is widely accepted that micro- and nanoscale inhomogeneities govern the performance of many thin-film solar cell absorbers. These inhomogeneities yield material properties (e.g., composition, structure, and charge collection) that are challenging to correlate across length scales and measurement modalities. The challenge is compounded if a correlation is sought during device operation or in conditions that mimic aging under particular stressors (e.g., heat and electrical bias). Correlative approaches, particularly those based on synchrotron x-ray sources, are powerful since they can access several material properties in different modes (e.g., fluorescence, diffraction, and absorption) with minimal sample preparation. Small-scale laboratory x-ray instruments have begun to offer multi-modality but are typically limited by low x-ray photon flux, low spatial resolution, or specific sample sizes. To overcome these limitations, a characterization stage was developed to enable multi-scale, multi-modal operando measurements of industrially relevant photovoltaic devices. The stage offers compatibility across synchrotron x-ray facilities, enabling correlation between nanoscale x-ray fluorescence microscopy, microscale x-ray diffraction microscopy, and x-ray beam induced current microscopy, among others. Furthermore, the stage can accommodate device sizes up to 25 × 25 mm 2 , offering access to multiple regions of interest and increasing the statistical significance of correlated properties. The stage materials can sustain humid and non-oxidizing atmospheres, and temperature ranges encountered by photovoltaic devices in operational environments (e.g., from 25 to 100 °C). As a case study, we discuss the functionality of the stage by studying Se-alloyed CdTe photovoltaic devices aged in the stage between 25 and 100 °C.

14 SOLAR ENERGY↗

Spatial calibration and synthetic diagnostic of a multi-energy hard x-ray camera at WEST tokamak

WEST (tungsten environment in steady-state tokamak) is starting operation for the first time with a water-cooled full tungsten divertor, enabling long pulse operation. Heating is provided by radiofrequency systems, including lower hybrid current drive (LHCD). In this context, a compact multi-energy hard x-ray camera has been installed for energy and space-resolved measurements of the electron temperature, the fast electron tail density produced by LHCD and runaway electrons, and the beam–target emission of tungsten at the target due to fast electron losses interacting with the divertor plates. The diagnostic is a pinhole camera based on a 2D pixel array detector (Pilatus 3 CdTe CMOS Hybrid-Pixel detector produced by DECTRIS). The novelty of this diagnostic technique is the detector’s capability of adjusting the threshold energy at pixel level. This innovation provides great flexibility in the energy configuration, allowing simultaneous space and energy-resolved x-ray measurements. This contribution details two important steps in the preparation of the diagnostic operation. First, the in-vessel spatial calibration that was carried out with a radioactive source. Second, the synthetic diagnostic is obtained by the suite of codes ALOHA/C3PO/LUKE/R5-X2, which simulates LH wave propagation and absorption, as well as the fast electron bremsstrahlung production.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Leaving in the lead: Priorities for perovskite photovoltaics

The need for moving electricity generation to a sustainable model requires the development of low cost ubiquitous photovoltaics (PVs) to harvest the planet’s primary energy source, the Sun. Building upon the successes of Si-based and CdTe-based PV technologies, PVs with lower-embodied energy and requiring lower carbon dioxide equivalent to produce will be required to meet long-term sustainability goals. In particular, thin-film technologies, such as high-efficiency metal halide perovskite (MHP) PV modules, provide avenues to reduced embodied energy, lower energy payback times, and enabling energy-dense tandems [H. M. Wikoff et al., Joule 6(7), 1710–1725 (2022) and V. Fthenakis, Renewable Sustainable Energy Rev. 13(9), 2746–2750 (2009)]. The ability to improve efficiency and lower energy payback time of next generation thin-film PV modules is a critical foundation for green H2 and electrification more broadly. In this regard, Pb-based MHP-PVs have separated themselves as a result of the high-efficiencies that can be realized across a range of electronic gaps. Questions regarding Pb-based MHP-PVs that are often asked, as the challenges of efficiency and reliability are met, revolve around the “problem” of the Pb content. Specifically, “does Pb toxicity preclude MHP-PV modules from being deployed at the TW scale?” To provide this sense of scale, in 2021, the United States burned 10.5 quads of coal, with 90% of that used for electricity generation. Given the energy content of coal of 29 MJ/kg and a residual lead content in that coal of 30 mg/kg, electricity generation from coal resulted in more lead emitted into the atmosphere than what would be required to produce over 2 TW of MHP-PV name plate capacity (assuming a 20% module efficiency and an ∼700 nm active layer). This amounts to more PV power than has been deployed across all PV technologies and geographies to date. This only includes US coal consumption; the rest of the world would be much larger. This example illustrates the scale of the material usage relative to the energy production. Imagine a power-generation technology that offsets these Pb emissions from coal and essentially sequesters this Pb content between two sheets of impermeable glass. Why should we let Pb’s history of misuse prevent it from being included in next generation PV modules that can enable a sustainable energy future?

14 SOLAR ENERGY↗

Spectral widths and Stokes shifts in InP-based quantum dots

InP-based quantum dots (QDs) have Stokes shifts and photoluminescence (PL) line widths that are larger than in II–VI semiconductor QDs with comparable exciton energies. The mechanisms responsible for these spectral characteristics are investigated in this paper. Upon comparing different semiconductors, we find the Stokes shift decreases in the following order: InP > CdTe > CdSe. We also find that the Stokes shift decreases with core size and decreases upon deposition of a ZnSe shell. We suggest that the Stokes shift is largely due to different absorption and luminescent states in the angular momentum fine structure. The energy difference between the fine structure levels, and hence the Stokes shifts, are controlled by the electron–hole exchange interaction. Luminescence polarization results are reported and are consistent with this assignment. Spectral widths are controlled by the extent of homogeneous and inhomogeneous broadening. Here, we report PL and PL excitation (PLE) spectra that facilitate assessing the roles of homogeneous and different inhomogeneous broadening mechanisms in the spectra of zinc-treated InP and InP/ZnSe/ZnS particles. There are two distinct types of inhomogeneous broadening: size inhomogeneity and core–shell interface inhomogeneity. The latter results in a distribution of core–shell band offsets and is caused by interfacial dipoles associated with In–Se or P–Zn bonding. Quantitative modeling of the spectra shows that the offset inhomogeneity is comparable to but somewhat smaller than the size inhomogeneity. The combination of these two types of inhomogeneity also explains several aspects of reversible hole trapping dynamics involving localized In 3+ /V Zn 2– impurity states in the ZnSe shells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Versatile multi-energy hard x-ray camera to study confined and unconfined fast electron dynamics and anisotropies (Invited)

A powerful and flexible hard x-ray (HXR) camera has been recently installed and tested on the WEST tokamak (CEA, France) in collaboration with the Princeton Plasma Physics Laboratory. The diagnostic is a pinhole camera fielded with a 2D pixel detector equipped with a 1 mm thick CdTe sensor. The novelty of this diagnostic technique is the detector’s capability of adjusting the threshold energy at the pixel level. This innovation provides great flexibility in the energy configuration, allowing simultaneous space, energy, and time resolved x-ray measurements. The novel camera has been used to measure the core radiation from non-Maxwellian (fast) electrons accelerated by Lower Hybrid (LH) waves and also the beam–target emission of tungsten in the divertor region produced by fast electron losses interacting with the target. In addition, anisotropic hard x-ray emission has been detected for the first time at the WEST core and edge plasma, with opposite toroidal intensity trends. Finally, experimental vertical and toroidal HXR profiles have been successfully reproduced with the LH code LUKE.

47 OTHER INSTRUMENTATION↗

Calibration of a broadband x-ray crystal spectrometer using a continuum x-ray source and photon-counting detectors

We report measurements of sensitivity of a broadband (≃20–30 keV) x-ray crystal spectrometer using a bremsstrahlung continuum x-ray source and several detectors, including an energy-discriminating photon-counting point detector (Si drift diode, Amptek Inc.), imaging hybrid photon-counting detectors (Eiger2-Si and Eiger2-CdTe, DECTRIS Ltd.), and image plates (SR type). Sensitivity is defined as a ratio of the crystal-reflected energy-position-dispersed spectrum measured by a given detector to the incident non-dispersed spectrum measured using the energy-discriminating point detector. The sensitivity derived from data measured exclusively by the point detector is considered detector-independent and serves as a reference. The sensitivities derived from data collected with the hybrid photon-counting detectors were matched to the reference using a scale factor of 1.05. The image plate-derived sensitivities required a scale factor of 1.16 to match the reference. Furthermore, the resulting mismatch in the shapes of all measured scaled sensitivities in the range of the spectrometer was ≲±10%, while the mismatch between the shapes of the sensitivities corresponding to the Si-based detectors was ≲±2.5%.

Crystal optics↗

Laser adaptive holographic hydroacoustic intensimeter

A new type of a vector hydrophone, a laser adaptive hydroacoustic intensimeter, is investigated. Two identical, spatially separated coil-type sensors are used as a primary receiver of the acoustic signal. The signals received at the sensor output are phase demodulated in a two-channel adaptive holographic interferometer based on two dynamic holograms multiplexed in a CdTe photorefractive crystal. Using a laser intensimeter, the acoustic field formed in a limited volume is studied. The performance characteristics of the intensimeter are determined experimentally; its threshold sensitivity, according to the acoustic field intensity, constitutes 0.1 × 10{sup −13} W m{sup −2}. (laser applications)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ionizing photon interactions modulate the optical properties of crystals with femtosecond scale temporal resolution

In this work, we continue our study of a new method for the detection of ionizing radiation with the potential for a dramatic improvement in coincidence time resolution (CTR) for time-of-flight positron emission tomography (ToF-PET) using the modulation of a material's optical properties instead of the scintillation mechanism. Our previous work has shown that for non-scintillation materials such as bismuth silicon oxide (BSO) and cadmium telluride (CdTe), their refractive index can be modulated by annihilation photon interactions. Additionally, the ultrafast nature of this process however remains unexplored. The ionizing radiation-induced charge carriers alter the local band structure in these materials, thus changing the complex refractive index. This mechanism is routinely used at the linac coherent light source (LCLS) facility of the SLAC National Accelerator Laboratory to measure x-ray pulse arrival times with femtosecond scale resolution for photon energies between 0.5 and 10 keV. The method described here follows that example by using a frequency chirped visible continuum pulse to provide a monotonic wavelength-to-time mapping by which one can measure the time-dependent refractive index modulation. In addition, we describe an interference-based measurement setup that allows for significantly improved sensitivity while preserving a timing precision of approximately 10 fs (σ) when measuring the arrival time of below 10 keV x-ray pulses with yttrium aluminum garnet (YAG) crystal. The method is presented in the context of ToF-PET application with further discussions on the potential CTR achievable if a similar detection concept is adopted for detecting 511 keV photons. Semi-empirical analysis indicates that the predicted CTR achievable is on the order of 1 ps (FWHM).

59 BASIC BIOLOGICAL SCIENCES↗

Characterization of 128 × 128 MM-PAD-2.1 ASIC: a fast framing hard x-ray detector with high dynamic range

Here, we characterize a new x-ray Mixed-Mode Pixel Array Detector (MM-PAD-2.1) Application Specific Integrated Circuit (ASIC). Using an integrating pixel front-end with dynamic charge removal architecture, the MM-PAD-2.1 ASIC extends the maximum measurable x-ray signal (in 20 keV photon units) to > 10 7 x-rays/pixel/frame while maintaining a low read noise across the full dynamic range, all while imaging continuously at a frame rate of up to 10 kHz. The in-pixel dynamic charge removal mechanism prevents saturation of the input amplifier and proceeds in parallel with signal integration to achieve deadtime-less measurements with incident x-ray rates of > 10 10 x-rays/pixel/s. The ASIC format consists of 128 × 128 square pixels each 150 μm on a side and is designed to be 3-side buttable so large arrays can be effectively tiled. Here we use both laboratory x-ray sources and the Cornell High Energy Synchrotron Source (CHESS) to characterize two single ASIC prototype detectors for both low (single x-ray) and high incident flux detection. In the first detector the ASIC was solder bump-bonded to a 500 μm thick Si sensor for efficient detection of x-rays below 20 keV, whereas the second detector used a 750 μm thick CdTe sensor for x-rays above ~20 keV.

36 MATERIALS SCIENCE↗

Impact of the Annealing Temperature on the Local Se Distribution and Optical Properties in CdSexTe1-x Solar Cells by Multimodal X-ray Microscopy

The introduction of Se in CdTe solar-cell absorbers has led to multiple beneficial effects in the devices, including an increased short-circuit current and an extended charge-carrier lifetime. A critical manufacturing step of CdSexTe1-x solar cells is CdCl2 annealing at high temperatures, during which Se diffuses through the absorber layer. Understanding the local Se distribution in the absorber and its impact on optical properties of the material is key for the further development of this thin-film solar cell technology. In a multimodal x-ray scanning microscopy approach, we investigated the impact of the annealing temperature of CdSexTe1-x solar cells on the Se distribution and on optical characteristics of the material. For this purpose, we exploited an upgraded x-ray excited optical luminescence (XEOL) detection unit that enables simultaneous spectrally and temporally resolved XEOL mapping at synchrotron facilities that are ideal for studying thin-film solar-cell materials with hard x-rays featuring high penetration depth and lateral resolution.

14 SOLAR ENERGY↗

Flexible positioning of a large area detector using an industrial robot

The DIAD beamline for Dual Imaging and Diffraction at Diamond Light Source has opted to use an industrial robot to position its Dectris Pilatus 2M CdTe diffraction detector. This setup was chosen to enable flexible positioning of the detector in a quarter-sphere around the sample position whilst reliably holding the large weight of 139 kg of detector, detector mount and cabling in a stable position. Metrology measurements showed that the detector can be positioned with a linear repeatability of <19.7 µm and a rotational repeatability of <16.3 µrad. The detector position stays stable for a 12 h period with <10.1 µm of movement for linear displacement and <3.8 µrad for rotational displacement. X-ray diffraction from calibration samples confirmed that the robot is sufficiently stable to resolve lattice d-spacings within the instrumental broadening given by detector position and beam divergence.

36 MATERIALS SCIENCE↗

In situ X-ray area detector flat-field correction at an operating photon energy without flat illumination

Flat-field calibration of X-ray area detectors is a challenge due to the inability to generate an X-ray flat-field at the selected photon energy the beamline operates at, which has a strong influence on the measurement behavior of the detector. A method is presented in which a simulated flat-field correction is calculated without flat-field measurements. Instead, a series of quick scattering measurements from an amorphous scatterer is used to calculate a flat-field response. The ability to rapidly obtain a flat-field response allows for recalibration of an X-ray detector as needed without significant expenditure of either time or effort. Area detectors on the beamlines used, such as the Pilatus 2M CdTe, PE XRD1621 and Varex XRD 4343CT, were found to have detector responses that drift slightly over timescales of several weeks or after exposure to high photon flux, suggesting the need to more frequently recalibrate with a new flat-field correction map.

47 OTHER INSTRUMENTATION↗

Development of an Optical Library for Coevaporated CdSe x Te 1– x

The conversion efficiency of CdTe solar cells may be improved by bandgap engineering, i.e., changing the bandgap value through the addition of Se in the absorber. The Se alloying enables a short-circuit current density improvement, as it leads to a bandgap energy value decrease. Furthermore, it has been associated with increased minority carrier lifetimes, assuring high open-circuit voltage values. An Se gradient profile control can further optimize the solar cell performance. Thus, an optical model baseline of the CdSe x Te 1–x (CST) compound was developed. Spectroscopic ellipsometry measurements were conducted to accurately extract the optical constants of ten CST layers deposited through coevaporation with x varying from 0 to 1. Using the measured dielectric function spectra from the discrete CST layers with varying x, and considering the composition-induced shift in the critical point energies, an energy-shift model was employed to develop the accurate optical library for the CST compound for any x value to provide data for future modeling and optimization. Furthermore, the library accuracy was validated through optical simulations of the quantum efficiency of a graded CST solar cell using the finite-difference time-domain method by replicating the Se profile in the absorber layer measured through secondary ion mass spectrometry.

14 SOLAR ENERGY↗

A New Approach to Indoor Characterization of PV Module Energy Yield Parameters

Temperature and solar irradiance are among the most relevant parameters that affect the energy yield of photovoltaic cells and modules. A rise in the module temperature leads to a significant decrease in the open circuit voltage and a small increase in the short circuit current. Here we use a new tool to determine temperature coefficients as well as to assess power rating of multi c-Si, mono c-Si, CdTe, and CIGS-based PV modules in controlled indoor conditions per IEC 60891 and IEC 61853-1. We use the tool to explore how nonuniformities in module temperature affect the accuracy of the temperature coefficients.

14 SOLAR ENERGY↗

Machine learning defect properties in Cd-based chalcogenides

Impurity energy levels in the band gap can have serious consequences for a semiconductor's performance as a photovoltaic absorber. Data-driven approaches can help accelerate the prediction of point defect properties in common semiconductors, and thus lead to the identification of potential deep lying impurity states. In this work, we use density functional theory (DFT) to compute defect formation energies and charge transition levels of hundreds of impurities in CdX chalcogenide compounds, where X = Te, Se or S. We apply machine learning techniques on the DFT data and develop on-demand predictive models for the formation energy and relevant transition levels of any impurity atom in any site. The trained ML models are general and accurate enough to predict the properties of any possible point defects in any Cd-based chalcogenide, as we prove by testing on a few selected defects in mixed chalcogen compounds CdTe 0.5 Se 0.5 and CdSe 0.5 S 0.5 . The ML framework used in this work can be extended to any class of semiconductors.

density functional theory↗

Synthesis of CdSeCdSexTe1-x/CdTe for Graded Solar Cells

Here, we have developed CdSe x Te 1-x /CdTe bilayer deposition for graded solar cell technology. Smoothly graded Se profiles with > 16% efficiency with Jsc=28 m A/cm 2 and 20-ns bulk lifetime has been observed observed. The CdSeTe reveals longer carrier lifetimes than CdTe within the same device.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Alternative Rear Contacts for Ultrathin CdSexTe1-x Solar Cells

The back contact is a key component for further developments of CdSeTe solar cells. In this contribution, we investigate several materials and designs that could help the development of highly-reflective, ohmic back contacts for conventional (3.45 um) and thin (800 nm) CdSeTe solar cells. We also explore numerically, nanostructured metal back contacts for light-trapping in ultrathin (200 nm) CdTe solar cells.

back contact↗