Search NASA⌕ Search

SEARCH · Search NASA

Results for “Coherent diffraction imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Simultaneous 8.2 keV phase-contrast imaging and 24.6 keV X-ray diffraction from shock-compressed matter at the LCLS

In this paper, we demonstrate simultaneous phase-contrast imaging (PCI) and X-ray diffraction from shock compressed matter at the Matter in Extreme Conditions endstation, at the Linac Coherent Light Source (LCLS). We utilize the chromaticity from compound refractive X-ray lenses to focus the 24.6 keV 3rd order undulator harmonic of the LCLS to a spot size of 5 μm on target to perform X-ray diffraction. Simultaneous PCI from the 8.2 keV fundamental X-ray beam is used to visualize and measure the transient properties of the shock wave over a 500 μm field of view. Furthermore, we demonstrate the ability to extend the reciprocal space measurements by 5 Å –1 , relative to the fundamental X-ray energy, by utilizing X-ray diffraction from the 3rd harmonic of the LCLS.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

braggedgemodeling

braggedgemodeling (bem) is an open-source Python package for modeling neutron Bragg-edge imaging. It computes the wavelength-dependent total neutron cross-section of a material (coherent and incoherent elastic, coherent and incoherent inelastic scattering, and absorption) from its crystal structure, and implements the March-Dollase texture model and the Jorgensen peak profile, supporting quantitative analysis of energy-resolved neutron imaging data (phase, stress/strain, and texture). Published in the Journal of Open Source Software (2018).

Lin, Jiao [Oak Ridge National Laboratory (ORNL), O↗

Observing Exoplanets with High-dispersion Coronagraphy. II. Demonstration of an Active Single-mode Fiber Injection Unit

High-dispersion coronagraphy (HDC) optimally combines high-contrast imaging techniques such as adaptive optics/wavefront control plus coronagraphy to high spectral resolution spectroscopy. HDC is a critical pathway toward fully characterizing exoplanet atmospheres across a broad range of masses from giant gaseous planets down to Earth-like planets. In addition to determining the molecular composition of exoplanet atmospheres, HDC also enables Doppler mapping of atmosphere inhomogeneities (temperature, clouds, wind), as well as precise measurements of exoplanet rotational velocities. Here, we demonstrate an innovative concept for injecting the directly imaged planet light into a single-mode fiber, linking a high-contrast adaptively corrected coronagraph to a high-resolution spectrograph (diffraction-limited or not). Our laboratory demonstration includes three key milestones: close-to-theoretical injection efficiency, accurate pointing and tracking, and on-fiber coherent modulation and speckle nulling of spurious starlight signal coupling into the fiber. Using the extreme modal selectivity of single-mode fibers, we also demonstrated speckle suppression gains that outperform conventional image-based speckle nulling by at least two orders of magnitude.

79 ASTRONOMY AND ASTROPHYSICS↗

Tailoring Vanadium Dioxide Film Orientation Using Nanosheets: a Combined Microscopy, Diffraction, Transport, and Soft X‐Ray in Transmission Study

Abstract Vanadium dioxide (VO 2 ) is a much‐discussed material for oxide electronics and neuromorphic computing applications. Here, heteroepitaxy of VO 2 is realized on top of oxide nanosheets that cover either the amorphous silicon dioxide surfaces of Si substrates or X‐ray transparent silicon nitride membranes. The out‐of‐plane orientation of the VO 2 thin films is controlled at will between (011) M1 /(110) R and (−402) M1 /(002) R by coating the bulk substrates with Ti 0.87 O 2 and NbWO 6 nanosheets, respectively, prior to VO 2 growth. Temperature‐dependent X‐ray diffraction and automated crystal orientation mapping in microprobe transmission electron microscope mode (ACOM‐TEM) characterize the high phase purity, the crystallographic and orientational properties of the VO 2 films. Transport measurements and soft X‐ray absorption in transmission are used to probe the VO 2 metal–insulator transition, showing results of a quality equal to those from epitaxial films on bulk single‐crystal substrates. Successful local manipulation of two different VO 2 orientations on a single substrate is demonstrated using VO 2 grown on lithographically patterned lines of Ti 0.87 O 2 and NbWO 6 nanosheets investigated by electron backscatter diffraction. Finally, the excellent suitability of these nanosheet‐templated VO 2 films for advanced lensless imaging of the metal–insulator transition using coherent soft X‐rays is discussed.

Le, Phu Tran Phong↗

Femtosecond time-resolved MeV electron diffraction

We report the experimental demonstration of femtosecond electron diffraction using high-brightness MeV electron beams. High-quality, single-shot electron diffraction patterns for both polycrystalline aluminum and single-crystal 1T-TaS 2 are obtained utilizing a 5 fC (~3 × 10 4 electrons) pulse of electrons at 2.8 MeV. The high quality of the electron diffraction patterns confirms that electron beam has a normalized emittance of ~50 nm rad. The transverse and longitudinal coherence length is ~11 and ~2.5 nm, respectively. The timing jitter between the pump laser and probe electron beam was found to be ~100 fs (rms). The temporal resolution is demonstrated by observing the evolution of Bragg and superlattice peaks of 1T-TaS 2 following an 800 nm optical pump and was found to be 130 fs. Lastly, our results demonstrate the advantages of MeV electrons, including large elastic differential scattering cross-section and access to high-order reflections, and the feasibility of ultimately realizing below 10 fs time-resolved electron diffraction.

74 ATOMIC AND MOLECULAR PHYSICS↗

Tagging efficiency study of incoherent diffractive vector meson production at the second interaction region at the Electron-Ion Collider

The Electron-Ion Collider (EIC) is an upcoming accelerator facility aimed at exploring the properties of quarks and gluons in nucleons and nuclei, shedding light on their structure and dynamics. The inaugural experimental apparatus, ePIC (electron-Proton and Ion Collider), is designed as a general-purpose detector to address the National Academy of Sciences and the Nuclear Science Advisory Committee physics program at the EIC. The wider EIC community is strongly supporting a second interaction region and an associated second detector to enhance the full science program. In this study, we evaluate how this second interaction region and detector can be complementary to ePIC. The layout of an interaction region for the second detector offers a secondary focus that provides better forward detector acceptance at scattering angles near θ ~ 0 mrad, which can specifically enhance the exclusive, tagging, and diffractive physics program. Here, this article presents an analysis of a tagging program using the second interaction region layout with incoherent diffractive vector meson production. The current design of the second EIC interaction region is evaluated for its vetoing capabilities of incoherent events required for the study of coherent diffractive measurements. We find an increased vetoing performance compared to the ePIC interaction region, thus improving measurements which are important for the spatial imaging of nucleons and nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-efficiency coherence-preserving harmonic rejection with crystal optics

This work reports a harmonic-rejection scheme based on the combination of Si(111) monochromator and Si(220) harmonic-rejection crystal optics. This approach is of importance to a wide range of X-ray applications in all three major branches of modern X-ray science (scattering, spectroscopy, imaging) based at major facilities, and especially relevant to the capabilities offered by the new diffraction-limited storage rings. It was demonstrated both theoretically and experimentally that, when used with a synchrotron undulator source over a broad range of X-ray energies of interest, the harmonic-rejection crystals transmit the incident harmonic X-rays on the order of 10 –6 . Considering the flux ratio of fundamental and harmonic X-rays in the incident beam, this scheme achieves a total flux ratio of harmonic radiation to fundamental radiation on the order of 10 –10 . The spatial coherence of the undulator beam is preserved in the transmitted fundamental radiation while the harmonic radiation is suppressed, making this scheme suitable not only for current third-generation synchrotron sources but also for the new diffraction-limited storage rings where coherence preservation is an even higher priority. Compared with conventional harmonic-rejection mirrors, where coherence is poorly preserved and harmonic rejection is less effective, this scheme has the added advantage of lower cost and footprint. Furthermore, this approach has been successfully utilized at the ultra-small-angle X-ray scattering instrument at the Advanced Photon Source for scattering, imaging and coherent X-ray photon correlation spectroscopy experiments. With minor modification, the harmonic rejection can be improved by a further five orders of magnitude, enabling even more performance capabilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantitative agreement between dynamical rocking curves in ultrafast electron diffraction for x-ray lasers

Electron diffraction through a thin patterned silicon membrane can be used to create complex spatial modulations in electron distributions. By precisely varying parameters such as crystallographic orientation and wafer thickness, the intensity of reflections in the diffraction plane can be controlled and by placing an aperture to block all but one spot, we can form an image with different parts of the patterned membrane, as is done for bright-field imaging in microscopy. The patterned electron beams can then be used to control phase and amplitude of subsequent x-ray emission, enabling novel coherent x-ray methods. Furthermore, the electrons themselves can also be used for femtosecond time resolved diffraction and microscopy. As a first step toward patterned beams, we demonstrate experimentally and through simulation the ability to accurately predict and control diffraction spot intensities. We simulate MeV transmission electron diffraction patterns using the multislice method for various crystallographic orientations of a single crystal Si(001) membrane near beam normal. The resulting intensity maps of the Bragg reflections are compared to experimental results obtained at the Accelerator Structure Test Area Ultrafast Electron Diffraction (ASTA UED) facility at SLAC. Furthermore, the fraction of inelastic and elastic scattering of the initial charge is estimated along with the absorption of the membrane to determine the contrast that would be seen in a patterned version of the Si(001) membrane.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cepstral scanning transmission electron microscopy imaging of severe lattice distortions

The development of four-dimensional (4D) scanning transmission electron microscopy (STEM) using fast detectors has opened-up new avenues for addressing some of longstanding challenges in electron imaging. One of these challenges is how to image severely distorted crystal lattices, such as at a dislocation core. Here we develop a new 4D-STEM technique, called Cepstral STEM, for imaging disordered crystals using electron diffuse scattering. In contrast to analysis based on Bragg diffraction, which measures the average and periodic scattering potential, electron diffuse scattering can detect fluctuations caused by crystal disorder. Local fluctuations of diffuse scattering are captured by scanning electron nanodiffraction (SEND) using a coherent probe. The harmonic signals in electron diffuse scattering are detected through Cepstral analysis and used for imaging. By integrating Cepstral analysis with 4D-STEM, we demonstrate that information about the distortive part of electron scattering potential can be separated and imaged at nm spatial resolution. Here, we apply the technique to the analysis of a dislocation core in SiGe and lattice distortions in a high entropy alloy.

36 MATERIALS SCIENCE↗

30-lens interferometer for high energy x-rays

We report a hard X-ray multilens interferometer consisting of 30 parallel compound refractive lenses. Under coherent illumination each CRL creates a diffraction limited focal spot - secondary source. An overlapping of coherent beams from these sources resulting in the interference pattern which has a rich longitudinal structure in accordance with the Talbot imaging formalism. The proposed interferometer was experimentally tested at ID11 ESRF beamline for the photon energies 32 keV and 65 keV. The fundamental and fractional Talbot images were recorded with the high resolution CCD camera. An effective source size in the order of 15 µm was determined from the first Talbot image proving that the multilens interferometer can be used as a high resolution beam diagnostic tool.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-beam X-ray ptychography using coded probes for rapid non-destructive high resolution imaging of extended samples

Imaging large areas of a sample non-destructively and with high resolution is of great interest for both science and industry. For scanning coherent X-ray diffraction microscopy, i. e., ptychography, the achievable scan area at a given spatial resolution is limited by the coherent photon flux of modern X-ray sources. Multibeam X-ray ptychography can improve the scanning speed by scanning the sample with several parallel mutually incoherent beams, e. g., generated by illuminating multiple focusing optics in parallel by a partially coherent beam. The main difficulty with this scheme is the robust separation of the superimposed signals from the different beams, especially when the beams and the illuminated sample areas are quite similar. We overcome this difficulty by encoding each of the probing beams with its own X-ray phase plate. This helps the algorithm to robustly reconstruct the multibeam data. We compare the coded multibeam scans to uncoded multibeam and single beam scans, demonstrating the enhanced performance on a microchip sample with regular and repeating structures.

47 OTHER INSTRUMENTATION↗

Characterization of the X-ray coherence properties of an undulator beamline at the Advanced Photon Source

In anticipation of the increased use of coherent X-ray methods and the need to upgrade beamlines to match improved source quality, here the coherence properties of the X-rays delivered by beamline 12ID-D at the Advanced Photon Source have been characterized. The measured X-ray divergence, beam size, brightness and coherent flux at energies up to 26 keV are compared with the calculated values from the undulator source, and the effects of beamline optics such as a mirror, monochromator and compound refractive lenses are evaluated. Diffraction patterns from slits as a function of slit width are analyzed using wave propagation theory to obtain the beam divergence and thus coherence length. Imaging of the source using a compound refractive lens was found to be the most accurate method for determining the vertical divergence. While the brightness and coherent flux obtained without a monochromator (`pink beam') agree well with those calculated for the source, those measured with the monochromator were a factor of three to six lower than the source, primarily because of vertical divergence introduced by the monochromator. The methods described herein should be widely applicable for measuring the X-ray coherence properties of synchrotron beamlines.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optical multiple object tracking techniques

Two multichannel multiple-object tracking techniques are reviewed. In the diffraction grating technique, the input scene is picked up by a TV camera and imaged onto a liquid-crystal light valve (LCLV), and the output side of the light valve is illuminated with a suitably polarized and collimated coherent laser beam to yield a reflected beam with polarization modulated according to the intensity of the incoherent input. This reflected beam passes through a beam splitter cube and an analyzer, resulting in an intensity modulated coherent image. An array of spectrum islands containing the information of the input appears after crossing a contact screen/lens combination. In the multiple-focus hololens technique, the scene of moving objects is sent into the LCTVSLM through a camera; a collimated laser beam is incident upon the LCTV screen; a low-pass filter is inserted between the LCTVSLM and the hololens for the removal of the high order diffractions due to the grid structure of the LCTV. The feasibility of the LCTVSLM and multiple-focus hololens technique is demonstrated.

Liu, Hua-Kuang↗

Optical instrumentation engineering in science, technology and society; Proceedings of the Sixteenth Annual Technical Meeting, San Mateo, Calif., October 16-18, 1972

Visual tracking performance in instrumentation is discussed together with photographic pyrometry in an aeroballistic range, optical characteristics of spherical vapor bubbles in liquids, and the automatic detection and control of surface roughness by coherent diffraction patterns. Other subjects explored are related to instruments, sensors, systems, holography, and pattern recognition. Questions of data handling are also investigated, taking into account minicomputer image storage for holographic interferometry analysis, the design of a video amplifier for a 90 MHz bandwidth, and autostereoscopic screens. Individual items are announced in this issue.

Katz, Y. H.↗

Inversion of dynamical Bragg intensities to complex structure factors by iterated projections. For Ultramic. 2020. ("Pico" Festschrift, May 2021)

We discuss a method for recovering complex structure factors from many simultaneously excited Bragg beam intensities is described. The method is applied to simulated transmission electron diffraction data over a wide range of crystal thickness and beam energies. The method is based on iterated projections between structure and scattering matrices, which are related by a matrix unitary transformation, exponential, which we invert. The algorithm removes multiple-scattering perturbations from diffraction data and might be extended to other fields, including X-ray and neutron diffraction and cryo-electron microscopy. Because coherent multiple scattering involves interference between Bragg beams, the method also solves the phase problem. Unlike dynamical inversion from electron microscope images or ptychography data, the method, which starts with Bragg beam intensities, provides complex structure factors unaffected by focusing errors or resolution limitations imposed by lenses. We provide inversions from simulated data with 441 simultaneously excited Bragg beams over a range of thickness and beam energy. We discuss the retrieval of chirality information from enantiomorphs, the efficient incorporation of symmetry information using the irreducible representation of the group of structure matrices, and the effect of HOLZ lines to provide three-dimensional information.

97 MATHEMATICS AND COMPUTING↗

Reuniting crystallography with real space: Ab initio structure elucidation with 4D-STEM

Structure elucidation via single-crystal methods has historically lacked experimental access to real-space information, instead relying exclusively on diffraction-space measurements of Bragg reflections. Here we exploit the dual-space imaging power of 4D scanning transmission electron microscopy to meaningfully integrate real-space information into the crystallographic workflow. We show that virtual apertures assembled by segmentation of high-angle annular dark-field images enable i) pixel-by-pixel separation of coherent Bragg signal from clusters of closely spaced nanocrystals and ii) selective extraction of integrated intensities from thinner subregions of individual specimens, facilitating retroactive tuning of multiple scattering artifacts. This strategy empowers us to simply pick and choose whichever nanoscale regions of interest generate the highest-quality diffraction patterns, allowing us to solve several independent structures of the metal-organic framework UiO-66 from specimens whose agglomerated morphology proved intractable for conventional microcrystal electron diffraction. Our method is compatible with both rotational and serial approaches to data processing, ultimately divulging the first scanning nanobeam electron diffraction structures determined by direct methods at subangstrom resolution.

Saha, Ambarneil↗

Three dimensions, two microscopes, one code: Automatic differentiation for x-ray nanotomography beyond the depth of focus limit

Conventional tomographic reconstruction algorithms assume that one has obtained pure projection images, involving no within-specimen diffraction effects nor multiple scattering. Advances in x-ray nanotomography are leading toward the violation of these assumptions, by combining the high penetration power of x-rays, which enables thick specimens to be imaged, with improved spatial resolution that decreases the depth of focus of the imaging system. We describe a reconstruction method where multiple scattering and diffraction effects in thick samples are modeled by multislice propagation and the 3D object function is retrieved through iterative optimization. We show that the same proposed method works for both full-field microscopy and for coherent scanning techniques like ptychography. Our implementation uses the optimization toolbox and the automatic differentiation capability of the open-source deep learning package TensorFlow, demonstrating a straightforward way to solve optimization problems in computational imaging with flexibility and portability.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗