Search NASA⌕ Search

SEARCH · Search NASA

Results for “Collective flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Portable Intravenous Fluid Production Device For Ground Use Project

Several medical conditions require the administration of intravenous (IV) fluids,but limitations of mass, volume, shelf-life, transportation, and local resources can restrict the availability of these important fluids. Such limitations are expected in long-duration space exploration missions and in remote or austere places on Earth. This design uses regular drinking water that is pumped through two filters to produce, in minutes, sterile, ultrapure water that meets the stringent quality standards of the United States Pharmacopeia for Water for Injection (Total Bacteria, Conductivity, Endo - toxins, Total Organic Carbon). The device weighs 2.2 lb (1 kg) and is 10 in. long, 5 in. wide, and 3 in. high (≈25, 13, and 7.5 cm, respectively) in its storage configuration. This handheld device produces one liter of medical-grade water in 21 minutes. Total production capacity for this innovation is expected to be in the hundreds of liters. The device contains one battery powered electric mini-pump. Alternatively, a manually powered pump can be attached and used. Drinking water enters the device from a source water bag, flows through two filters, and final sterile production water exits into a sealed, medical-grade collection bag. The collection bag contains pre-placed crystalline salts to mix with product water to form isotonic intravenous medical solutions. Alternatively, a hypertonic salt solution can be injected into a filled bag. The filled collection bag is detached from the device and is ready for use or storage. This device currently contains one collection bag, but a manifold of several pre-attached bags or replacement of single collection bags under sterile needle technique is possible for the production of multiple liters. The entire system will be flushed, sealed, and radiation-sterilized. Operation of the device is easy and requires minimal training. Drinking water is placed into the collection bag. Inline stopcock flow valves at the source and collection bags are opened, and the mini-pump is turned on by a switch to begin fluid flow. When the collection bag is completely filled with the medical- grade water, the pump can be turned off. The pump is designed so it cannot pump air, and overfilling of the collection bag with fluid is avoided by placing an equal amount of water in the source bag. Backflow is avoided by inline check valves. The filled collection bag is disconnected from its tubing and is ready for use. The source bag can be refilled for production of multiple liters, or the source bag can be replaced with an input tube that can be placed in a larger potable water source if the device is attended. The device functions in all orientations independent of any gravity fields. In addition to creating IV fluids, the device produces medical-grade water, which can be used for mixing with medications for injection, reconstituting freeze-dried blood products for injection, or for wound hydration or irrigation. Potential worldwide use is expected with medical activities in environments that have limited resources, storage, or resupply such as in military field operations, humanitarian relief efforts, submarines, commercial cruise ships, etc.

Technology Portfolio System↗

Evaluation of Hopper Flow Prediction based on Cubical Triaxial Tester Data and FEM

A cubical triaxial tester (CTT) laboratory device was used to collect key bulk flow characteristics of Crumbles® 6mm rotary sheared woody biomass and Crumbles® 2mm rotary sheard corn stover. The flow properties and a CAD model of a hopper and conveyor system to predict the consistency of flow of material from the hopper. Prediction included the likeliness of jamming, bridging, or ratholing. Each material was then loaded into the hopper and the actual bulk flow was measured. Measured flow closely matched the predicted flow.

09 BIOMASS FUELS↗

The harmonic oscillator and nuclear physics

The three-dimensional harmonic oscillator plays a central role in nuclear physics. It provides the underlying structure of the independent-particle shell model and gives rise to the dynamical group structures on which models of nuclear collective motion are based. It is shown that the three-dimensional harmonic oscillator features a rich variety of coherent states, including vibrations of the monopole, dipole, and quadrupole types, and rotations of the rigid flow, vortex flow, and irrotational flow types. Nuclear collective states exhibit all of these flows. It is also shown that the coherent state representations, which have their origins in applications to the dynamical groups of the simple harmonic oscillator, can be extended to vector coherent state representations with a much wider range of applicability. As a result, coherent state theory and vector coherent state theory become powerful tools in the application of algebraic methods in physics.

Rowe, D. J.↗

Interpretable Models for Workflow Differentiation in High-Performance Scientific Networks

Scientific workflows in high-performance networks spawn hundreds of interdependent flows that must be managed collectively—yet existing network classifiers treat each flow in isolation, leading to fragmented QoS decisions and missed interflow patterns. We present a novel traffic classification solution that operates at the workflow level, distinguishing entire filetransfer operations from streaming analytics by capturing how concurrent flows interact and burst together. We introduce a workflow identification window (WIW) that ingests raw packet headers from parallel flows into unified tensors, preserving the spatial-temporal patterns that differentiate scientific workflows. This approach achieves 98.7% accuracy using CNN, LSTM, and hybrid architectures, while maintaining 84% accuracy on production traffic collected a week later—demonstrating robustness to temporal drift. By integrating SHAP and GradCAM explainability, we reveal that early-packet timing patterns and cross-flow correlations drive classification decisions, providing operators with interpretable insights. Our system enables coherent workflow-level QoS enforcement and dynamic bandwidth allocation in scientific networks, eliminating manual per-flow configuration while maintaining classification latency at millisecond level.

Giannakou, Anna [LBL, Berkeley]↗

Full Aerothermal Characterization of the 6- by 9-Foot Icing Research Tunnel (2019 Test)

A full aerothermal characterization of the NASA Glenn Icing Research Tunnel (IRT) was completed in August 2019. A mandatory maintenance period required the test entry to be separated into two phases: the first occurring in April 2019 and the second in August 2019. The hardware used during this test entry consisted of the 6-foot quick-check rake, 6-foot traversing rake, RTD array, and hot-wire rake. The 6-foot quick check rake collects static pressure, total pressure, total temperature, and flow angularity data along the centerline of the test section. The data from the 6-foot quick-check rake were used to generate test section calibration relationships for total and static pressure as well as implement statistical process control. The 6-foot traversing rake collects flow uniformity data across the test section for various flow parameters, such as static pressure, total pressure, and flow angularity. Total temperature flow uniformity data is mapped by the RTD array and is used to generate the test section calibration relationship for total temperature. The hot-wire rake measures turbulence intensity at three lateral locations and characterizes airspeed unsteadiness in the test section. The test entry resulted in updated calibration relationships and a full characterization of test section flow quality and flow uniformity in the IRT.

Wind↗

Potential flows in propulsion system inlets

Collection of computer programs used to calculate compressible potential flow in arbitrary axisymmetric inlet at any combination of operating conditions of inlet mass-flow rate, free stream velocity, and incident angle proves useful in development of wide variety of propulsion system inlet designs.

Farrell, C. A., Jr.↗

Light nuclei collectivity from s NN = 3 GeV Au+Au collisions at RHIC

In high-energy heavy-ion collisions, partonic collectivity is evidenced by the constituent quark number scaling of elliptic flow anisotropy for identified hadrons. A breaking of this scaling and dominance of baryonic interactions is found for identified hadron collective flow measurements in sNN = 3 GeV Au+Au collisions. In this paper, we report measurements of the first- and second-order azimuthal anisotropic parameters, v1 and v2, of light nuclei (d, t, 3He, 4He) produced in sNN = 3 GeV Au+Au collisions at the STAR experiment. An atomic mass number scaling is found in the measured v1 slopes of light nuclei at mid-rapidity. For the measured v2 magnitude, a strong rapidity dependence is observed. Unlike v2 at higher collision energies, the v2 values at mid-rapidity for all light nuclei are negative and no scaling is observed with the atomic mass number. Calculations by the Jet AA Microscopic Transport Model (JAM), with baryonic mean-field plus nucleon coalescence, are in good agreement with our observations, implying baryonic interactions dominate the collective dynamics in 3 GeV Au+Au collisions at RHIC.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Treatment Planning Constraints to Avoid Xerostomia in Head-and-Neck Radiotherapy: An Independent Test of QUANTEC Criteria Using a Prospectively Collected Dataset

Purpose: The severe reduction of salivary function (xerostomia) is a common complication after radiation therapy for head-and-neck cancer. Consequently, guidelines to ensure adequate function based on parotid gland tolerance dose-volume parameters have been suggested by the QUANTEC group and by Ortholan et al. We perform a validation test of these guidelines against a prospectively collected dataset and compared with a previously published dataset. Methods and Materials: Whole-mouth stimulated salivary flow data from 66 head-and-neck cancer patients treated with radiotherapy at the British Columbia Cancer Agency (BCCA) were measured, and treatment planning data were abstracted. Flow measurements were collected from 50 patients at 3 months, and 60 patients at 12-month follow-up. Previously published data from a second institution, Washington University in St. Louis (WUSTL), were used for comparison. A logistic model was used to describe the incidence of Grade 4 xerostomia as a function of the mean dose of the spared parotid gland. The rate of correctly predicting the lack of xerostomia (negative predictive value [NPV]) was computed for both the QUANTEC constraints and Ortholan et al. recommendation to constrain the total volume of both glands receiving more than 40 Gy to less than 33%. Results: Both datasets showed a rate of xerostomia of less than 20% when the mean dose to the least-irradiated parotid gland is kept to less than 20 Gy. Logistic model parameters for the incidence of xerostomia at 12 months after therapy, based on the least-irradiated gland, were D{sub 50} = 32.4 Gy and and {gamma} = 0.97. NPVs for QUANTEC guideline were 94% (BCCA data), and 90% (WUSTL data). For Ortholan et al. guideline NPVs were 85% (BCCA) and 86% (WUSTL). Conclusion: These data confirm that the QUANTEC guideline effectively avoids xerostomia, and this is somewhat more effective than constraints on the volume receiving more than 40 Gy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Emittance Measurements for a Thin Liquid Sheet Flow

The Liquid Sheet Radiator (LSR) is an external flow radiator that uses a triangular-shaped flowing liquid sheet as the radiating surface. It has potentially much lower mass than solid wall radiators such as pumped loop and heat pipe radiators, along with being nearly immune to micrometeoroid penetration. The LSR has an added advantage of simplicity. Surface tension causes a thin (100-300 microns) liquid sheet to coalesce to a point, causing the sheet flow to have a triangular shape. Such a triangular sheet is desirable since it allows for simple collection of the flow at a single point. A major problem for all external flow radiators is the requirement that the working fluid be of very low (approx. 10(sup -8) torr) vapor pressure to keep evaporative losses low. As a result, working fluids are limited to certain oils (such as used in diffusion pumps) for low temperatures (300-400 K) and liquid metals for higher temperatures. Previous research on the LSR has been directed at understanding the fluid mechanics of thin sheet flows and assessing the stability of such flows, especially with regard to the formation of holes in the sheet. Taylor studied extensively the stability of thin liquid sheets both theoretically and experimentally. He showed that thin sheets in a vacuum are stable. The latest research has been directed at determining the emittance of thin sheet flows. The emittance was calculated from spectral transmittance data for the Dow Corning 705 silicone oil. By experimentally setting up a sheet flow, the emittance was also determined as a function of measurable quantities, most importantly, the temperature drop between the top of the sheet and the temperature at the coalescence point of the sheet. Temperature fluctuations upstream of the liquid sheet were a potential problem in the analysis and were investigated.

Englehart, Amy N.↗

Development of a Model and Computer Code to Describe Solar Grade Silicon Production Processes

The program aims at developing mathematical models and computer codes based on these models, which allow prediction of the product distribution in chemical reactors for converting gaseous silicon compounds to condensed-phase silicon. The major interest is in collecting silicon as a liquid on the reactor walls and other collection surfaces. Two reactor systems are of major interest, a SiCl4/Na reactor in which Si(l) is collected on the flow tube reactor walls and a reactor in which Si(l) droplets formed by the SiCl4/Na reaction are collected by a jet impingement method. During this quarter the following tasks were accomplished: (1) particle deposition routines were added to the boundary layer code; and (2) Si droplet sizes in SiCl4/Na reactors at temperatures below the dew point of Si are being calculated.

Srivastava, R.↗

Microscopic Uni-axial Bohr-Mottelson Rotational Model

A microscopic version of the phenomenological Bohr-Mottelson unified adiabatic rotational model is derived using only space-fixed particle coordinates, and without imposing any constraints on the particle coordinates or the intrinsic wavefunction. It is shown that this can done only for rigid flow. A collective-rotation velocity field is defined and is used to show that, although their Hamiltonians are closely related, the flows in a multi-fermion and single-particle system are inherently different.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Utilization of event shape in search of the chiral magnetic effect in heavy-ion collisions

The search for the chiral magnetic effect (CME) has been a subject of great interest in the field of high-energy heavy-ion collision physics, and various observables have been proposed to probe the CME. Experimental observables are often contaminated with background contributions arising from collective motions (specifically elliptic flow) of the collision system. We present a method study of event-shape engineering (ESE) that projects the CME-sensitive γ 112 correlator and its variations (γ 132 and γ 123 ) to a class of events with minimal flow. We discuss the realization of the zero-flow mode, the sensitivity on the CME signal, and the corresponding statistical significance for Au + Au, Ru + Ru, and Zr + Zr collisions at √s NN = 200 GeV with a multiphase transport model, as well as a new event generator, event-by-event anomalous-viscous fluid dynamics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

GlennICE Simulation of 24, 28 and 36 Inch Diameter eVTOL Propellers in Forward Flight

Flow solutions and water collection results are presented for three different propeller sizes. Flow solutions were generated using the NASA FUN3D software, and water collection was simulated using NASA GlennICE software. The geometries considered represent experimental articles that have been tested in the NASA Icing Research Tunnel. Each configuration has four blades. For the experiment, the same spinner centerbody is used for each propeller size. The different sized blades are similar for radii larger than about 40% of total span. Operating conditions were chosen to match operating points where experimental data was collected. Results are presented for both single bin simulations, as well as 7-bin Langmuir D distributions. For 80 microns MVD the Langmuir D distribution showed small differences compared to the single bin. For 15 microns MVD the Langmuir D distribution had a larger impact, especially on the spinner. In the experiment, the centerbody was unchanged as propeller size was changed. In this paper, additional simulations were completed with the 36 inch case perfectly scaled down to 24 and 28 inch. The perfect geometric scaling allows for an assessment of the effect of constant centerbody size on the results. While slight differences in pressure distribution on the propeller are visible between scaled and non-scaled centerbody, the effect seems quite minimal regarding water collection. All simulations were run very cold to ensure rime ice, since handling runback water in the non-inertial frame is beyond the scope of the present work. Ice shapes were generated using a single time step growth. The total mass on the blade and spinner was generally underpredicted for 15 microns MVD, and overpredicted for 80 microns MVD. When comparing ice shapes at operating conditions the numerical results produce very similar ice shapes.

Aircraft Icing↗

GlennICE Simulation of 24, 28 and 36 Inch Diameter eVTOL Propellers in Forward Flight

Flow solutions and water collection results are presented for three different propeller sizes. Flow solutions were generated using the NASA FUN3D software, and water collection was simulated using NASA GlennICE software. The geometries considered represent experimental articles that have been tested in the NASA Icing Research Tunnel. Each configuration has four blades. For the experiment, the same spinner centerbody is used for each propeller size. The different sized blades are similar for radii larger than about 40% of total span. Operating conditions were chosen to match operating points where experimental data was collected. Results are presented for both single bin simulations, as well as 7-bin Langmuir D distributions. For 80 microns MVD the Langmuir D distribution showed small differences compared to the single bin. For 15 microns MVD the Langmuir D distribution had a larger impact, especially on the spinner. In the experiment, the centerbody was unchanged as propeller size was changed. In this paper, additional simulations were completed with the 36 inch case perfectly scaled down to 24 and 28 inch. The perfect geometric scaling allows for an assessment of the effect of constant centerbody size on the results. While slight differences in pressure distribution on the propeller are visible between scaled and non-scaled centerbody, the effect seems quite minimal regarding water collection. All simulations were run very cold to ensure rime ice, since handling runback water in the non-inertial frame is beyond the scope of the present work. Ice shapes were generated using a single time step growth. The total mass on the blade and spinner was generally underpredicted for 15 microns MVD, and overpredicted for 80 microns MVD. When comparing ice shapes at operating conditions the numerical results produce very similar ice shapes.

Aircraft Icing↗

Flow Quality Studies of the NASA Glenn Research Center Icing Research Tunnel Circuit (1995 Tests)

The purpose of conducting the flow-field surveys described in this report was to more fully document the flow quality in several areas of the tunnel circuit in the NASA Glenn Research Center Icing Research Tunnel. The results from these surveys provide insight into areas of the tunnel that were known to exhibit poor flow quality characteristics and provide data that will be useful to the design of flow quality improvements and a new heat exchanger for the facility. An instrumented traversing mechanism was used to survey the flow field at several large cross sections of the tunnel loop over the entire speed range of the facility. Flow-field data were collected at five stations in the tunnel loop, including downstream of the fan drive motor housing, upstream and downstream of the heat exchanger, and upstream and downstream of the spraybars located in the settling chamber upstream of the test section. The data collected during these surveys greatly expanded the data base describing the flow quality in each of these areas. The new data matched closely the flow quality trends recorded from earlier tests. Data collected downstream of the heat exchanger and in the settling chamber showed how the configuration of the folded heat exchanger affected the pressure, velocity, and flow angle distributions in these areas. Smoke flow visualization was also used to qualitatively study the flow field in an area downstream of the drive fan and in the settling chamber/contraction section.

Arrington, E. Allen↗

Two-axis direct fluid shear stress sensor

A micro sized multi-axis semiconductor skin friction/wall shear stress induced by fluid flow. The sensor design includes a shear/strain transduction gimble connected to a force collecting plate located at the flow boundary surface. The shear force collecting plate is interconnected by an arm to offset the tortional hinges from the fluid flow. The arm is connected to the shear force collecting plate through dual axis torsional hinges with piezoresistive torsional strain gauges. These gauges are disposed on the tortional hinges and provide a voltage output indicative of applied shear stress acting on the force collection plate proximate the flow boundary surface. Offsetting the torsional hinges creates a force concentration and resolution structure that enables the generation of a large stress on the strain gauge from small shear stress, or small displacement of the collecting plate. The design also isolates the torsional sensors from exposure to the fluid flow.

Bajikar, Sateesh↗

Liquid Oxygen/Liquid Methane Integrated Propulsion System Test Bed

In support of NASA?s Propulsion and Cryogenic Advanced Development (PCAD) project, a liquid oxygen (LO2)/liquid methane (LCH4) Integrated Propulsion System Test Bed (IPSTB) was designed and advanced to the Critical Design Review (CDR) stage at the Johnson Space Center. The IPSTB?s primary objectives are to study LO2/LCH4 propulsion system steady state and transient performance, operational characteristics and to validate fluid and thermal models of a LO2/LCH4 propulsion system for use in future flight design work. Two phase thermal and dynamic fluid flow models of the IPSTB were built to predict the system performance characteristics under a variety of operating modes and to aid in the overall system design work. While at ambient temperature and simulated altitude conditions at the White Sands Test Facility, the IPSTB and its approximately 600 channels of system instrumentation would be operated to perform a variety of integrated main engine and reaction control engine hot fire tests. The pressure, temperature, and flow rate data collected during this testing would then be used to validate the analytical models of the IPSTB?s thermal and dynamic fluid flow performance. An overview of the IPSTB design and analytical model development will be presented.

Flynn, Howard↗

Microwave Sterilization and Depyrogenation System

A fully functional, microgravity-compatible microwave sterilization and depyrogenation system (MSDS) prototype was developed that is capable of producing medical-grade water (MGW) without expendable supplies, using NASA potable water that currently is available aboard the International Space Station (ISS) and will be available for Lunar and planetary missions in the future. The microwave- based, continuous MSDS efficiently couples microwaves to a single-phase, pressurized, flowing water stream that is rapidly heated above 150 C. Under these conditions, water is rapidly sterilized. Endotoxins, significant biological toxins that originate from the cell walls of gram-negative bacteria and which represent another defining MGW requirement, are also deactivated (i.e., depyrogenated) albeit more slowly, with such deactivation representing a more difficult challenge than sterilization. Several innovations culminated in the successful MSDS prototype design. The most significant is the antenna-directed microwave heating of a water stream flowing through a microwave sterilization chamber (MSC). Novel antenna designs were developed to increase microwave transmission efficiency. These improvements resulted in greater than 95-percent absorption of incident microwaves. In addition, incorporation of recuperative heat exchangers (RHxs) in the design reduced the microwave power required to heat a water stream flowing at 15 mL/min to 170 C to only 50 W. Further improvements in energy efficiency involved the employment of a second antenna to redirect reflected microwaves back into the MSC, eliminating the need for a water load and simplifying MSDS design. A quick connect (QC) is another innovation that can be sterilized and depyrogenated at temperature, and then cooled using a unique flow design, allowing collection of MGW at atmospheric pressure and 80 C. The final innovation was the use of in-line mixers incorporated in the flow path to disrupt laminar flow and increase contact time at a given flow rate. These technologies can be employed in small-scale systems for efficient production of MGW in the laboratory or in a range of larger systems that meet various industrial requirements. The microwave antennas can also be adapted to selectively sterilize vulnerable connections to ultra-pure water production facilities or biologically vulnerable systems where microorganisms may intrude.

Akse, James R.↗