At least 361 records · Page 20

Aerial Measuring System (AMS)/Israel Atomic Energy Commission (IAEC) Joint Comparison Study Report

Under the 13th Bilateral Meeting to Combat Nuclear Terrorism conducted on January 8–9, 2013, the committee approved the development of a cost-effective proposal to conduct a Comparison Study of the Aerial Measuring System (AMS) of the U.S. Department of Energy (DOE), National Nuclear Security Administration (NNSA) and Israel Atomic Energy Commission (IAEC). The study was to be held at the Remote Sensing Laboratory (RSL), Nellis Air Force Base, Las Vegas, Nevada, with measurements at the Nevada National Security Site (NNSS). The goal of the AMS and the IAEC joint survey was to compare the responses of the two agencies’ aerial radiation detection systems to varied radioactive surface contamination levels and isotopic composition experienced at the NNSS, and the differing data processing techniques utilized by the respective teams. Considering that for the comparison both teams were using custom designed and built systems, the main focus of the short campaign was to investigate the impact of the detector size and data analysis techniques used by both teams. The AMS system, SPectral Advanced Radiological Computer System, Model A (SPARCS-A), designed and built by RSL, incorporates four different size sodium iodide (NaI) crystals: 1" × 1", 2" × 4" × 4", 2" × 4" ×16", and an “up-looking” 2" × 4" × 4". The Israel AMS System, Air RAM 2000, was designed by the IAEC Nuclear Research Center – Negev (NRCN) and built commercially by ROTEM Industries (Israel) and incorporates two 2" diameter × 2" long NaI crystals. The operational comparison was conducted at RSL-Nellis in Las Vegas, Nevada, during week of June 24–27, 2013. The Israeli system, Air RAM 2000, was shipped to RSL-Nellis and mounted together with the DOE SPARCS on a DOE Bell-412 helicopter for a series of aerial comparison measurements at local test ranges, including the Desert Rock Airport and Area 3 at the NNSS. A 4-person Israeli team from the IAEC NRCN supported the activity together with 11 members of the RSL team, which consisted of pilots, mechanics, scientists, a data analyst, equipment operators, and operation specialists. All planned flight activities followed by scientific discussions on the collected data were completed. For IAEC, the joint survey provided an opportunity to characterize their system’s response to extended sources of various fission products at the NNSS. As both systems play an important role in their respective countries’ (United States and Israel) national framework of radiological emergency response and are subject to multiple mutual cooperation agreements, it was important for each country to obtain more thorough knowledge of how they would employ these important assets and define the roles that they would each play in an actual response.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lidar Inter-Comparison Exercise Final Campaign Report

The objective of this IOP was to evaluate the performances of the new Leosphere R-MAN 510 lidar procured by the Australian Bureau of Meteorology, by testing it against the MPL and Raman lidars at the Darwin ARM site. This lidar is an eye-safe (355 nm), turn-key mini Raman lidar, which allows for the detection of aerosols and cloud properties, and the retrieval of particulate extinction profiles. To do so, the R-MAN 510 lidar has been operated at the Darwin ARM site, next to the MPL, Raman lidar, and Vaisala ceilometer for three months (from 20 January 2013 to 20 April 2013) in order to collect a good sample for statistical comparisons. The comparisons with the Raman lidar were not performed, since the Raman lidar attenuated backscatter and depolarization ratio product was not available. A new product has just been delivered to the ARM archive as a value-added product, hence this study will continue. Nevertheless we have developed software to match the different space and time resolutions of the other lidars and project the data onto a common grid to permit detailed comparison of the instruments’ performance and an enhanced analysis of clouds and aerosols through the use of composite data products, like the ratios of attenuated backscatters, attenuated scattering ratios and depolarization ratios. Comparisons between the MPL and R-MAN510 lidar data exhibit large differences in total attenuated backscatter at 355 and 532 nm, attenuated scattering ratios, and aerosol volume depolarization ratios. Differences in attenuated backscatter result mainly from the different relative contributions of scattering from molecules and particles at the different wavelengths, but there are some intriguing differences that will require further investigations. The differences in volume depolarization ratios are due to the much larger contribution of molecular returns to the volume depolarization ratio (5 times larger at 355 nm than at 532 nm). The R-MAN510 lidar is also found to be much less sensitive to daylight solar background illumination, which is greater at the visible wavelength than in the UV.

54 ENVIRONMENTAL SCIENCES↗

Development of a Comparison Framework for Evaluating Environmental Contours of Extreme Sea States

Environmental contours of extreme sea states are often utilized for the purposes of reliability-based offshore design. Many methods have been proposed to estimate environmental contours of extreme sea states, including, but not limited to, the traditional inverse first-order reliability method (I-FORM) and subsequent modifications, copula methods, and Monte Carlo methods. These methods differ in terms of both the methodology selected for defining the joint distribution of sea state parameters and in the method used to construct the environmental contour from the joint distribution. It is often difficult to compare the results of proposed methods to determine which method should be used for a particular application or geographical region. The comparison of the predictions from various contour methods at a single site and across many sites is important to making environmental contours of extreme sea states useful in practice. The goal of this paper is to develop a comparison framework for evaluating methods for developing environmental contours of extreme sea states. This paper develops generalized metrics for comparing the performance of contour methods to one another across a collection of study sites, and applies these metrics and methods to develop conclusions about trends in the wave resource across geographic locations, as demonstrated for a pilot dataset. These proposed metrics and methods are intended to judge the environmental contours themselves relative to other contour methods, and are thus agnostic to a specific device, structure, or field of application. The metrics developed and applied in this paper include measures of predictive accuracy, physical validity, and aggregated temporal performance that can be used to both assess contour methods and provide recommendations for the use of certain methods in various geographical regions. The application and aggregation of the metrics proposed in this paper outline a comparison framework for environmental contour methods that can be applied to support design analysis workflows for offshore structures. This comparison framework could be extended in future work to include additional metrics of interest, potentially including those to address issues pertinent to a specific application area or analysis discipline, such as metrics related to structural response across contour methods or additional physics-based metrics based on wave dynamics.

54 ENVIRONMENTAL SCIENCES↗

GEO-LEO Reflective Band Inter-Comparison with BRDF and Atmospheric Scattering Corrections

The inter-comparison of the reflective solar bands (RSB) between the instruments onboard a geostationary orbit satellite and a low Earth orbit satellite is very helpful in assessing their calibration consistency. Himawari-8 was launched 7 October 2014 and GOES-R was launched on 19 November 2016. Unlike previous GOES instruments, the Advanced Himawari Imager (AHI) on Himawari-8 and the Advanced Baseline Imager (ABI) on GOES-R have onboard calibrators for the RSB. Independent assessment of calibration is nonetheless important to enhance their product quality. MODIS (Moderate Resolution Imaging Spectroradiometer) and VIIRS (Visible Infrared Imaging Radiometer Suite) can provide good references for sensor calibration. In this work, the inter-comparison between AHI and VIIRS is performed over a pseudo-invariant target. The use of stable and uniform calibration sites provides comparison with accurate adjustment for band spectral difference, reduction of impact from pixel mismatching, and consistency of BRDF (Bidirectional Reflectance Distribution Function) and atmospheric correction. The site used is the Strzelecki Desert in Australia. Due to the difference in solar and view angles, two corrections must be applied in order to compare the measurements. The first is the atmospheric scattering correction applied to the top of atmosphere reflectance measurements. The second correction is applied to correct the BRDF effect. The atmospheric correction is performed using a vector version of the Second Simulation of a Satellite Signal in the Solar Spectrum (6SV) model and the BRDF correction is performed using a semi-empirical model. Our results show that AHI band 1 (0.47 microns) has a good agreement with VIIRS band M3 within 0.15 percent. AHI band 5 (1.61 microns) shows the largest difference (5.09 percent) with VIIRS band M10, while AHI band 5 shows the least difference (1.87 percent) in comparison with VIIRS band I3. The methods developed in this work can also be directly applied to assess GOES-16/ABI (Geostationary Operational Environment Satellite16 / Advanced Baseline Imager) calibration consistency, a topic we will address in the future.

The inter-comparison of the reflective solar bands↗

Using GTO-Velo to Facilitate Communication and Sharing of Simulation Results in Support of the Geothermal Technologies Office Code Comparison Study

The Geothermal Technologies Office Code Comparison Study (GTO-CCS) aims to support the DOE Geothermal Technologies Office in organizing and executing a model comparison activity. This project is directed at testing, diagnosing differences, and demonstrating modeling capabilities of a worldwide collection of numerical simulators for evaluating geothermal technologies. Teams of researchers are collaborating in this code comparison effort, and it is important to be able to share results in a forum where technical discussions can easily take place without requiring teams to travel to a common location. Pacific Northwest National Laboratory has developed an open-source, flexible framework called Velo that provides a knowledge management infrastructure and tools to support modeling and simulation for a variety of types of projects in a number of scientific domains. GTO-Velo is a customized version of the Velo Framework that is being used as the collaborative tool in support of the GTO-CCS project. Velo is designed around a novel integration of a collaborative Web-based environment and a scalable enterprise Content Management System (CMS). The underlying framework provides a flexible and unstructured data storage system that allows for easy upload of files that can be in any format. Data files are organized in hierarchical folders and each folder and each file has a corresponding wiki page for metadata. The user interacts with Velo through a web browser based wiki technology, providing the benefit of familiarity and ease of use. High-level folders have been defined in GTO-Velo for the benchmark problem descriptions, descriptions of simulator/code capabilities, a project notebook, and folders for participating teams. Each team has a subfolder with write access limited only to the team members, where they can upload their simulation results. The GTO-CCS participants are charged with defining the benchmark problems for the study, and as each GTO-CCS Benchmark problem is defined, the problem creator can provide a description using a template on the metadata page corresponding to the benchmark problem folder. Project documents, references and videos of the weekly online meetings are shared via GTO-Velo. A results comparison tool allows users to plot their uploaded simulation results on the fly, along with those of other teams, to facilitate weekly discussions of the benchmark problem results being generated by the teams. GTO-Velo is an invaluable tool providing the project coordinators and team members with a framework for collaboration among geographically dispersed organizations.

Collaborative Tools↗

Code Comparison Study Fosters Confidence in the Numerical Simulation of Enhanced Geothermal Systems

Numerical simulation has become a standard analytical tool for scientists and engineers to evaluate the potential and performance of enhanced geothermal systems. A variety of numerical simulators developed by industry, universities, and national laboratories are currently available and being applied to better understand enhanced geothermal systems at the field scale. To yield credible predictions and be of value to site operators, numerical simulators must be able to accurately represent the complex coupled processes induced by producing geothermal systems, such as fracture aperture changes due to thermal stimulation, fracture shear displacement with fluid injection, rate of thermal depletion of reservoir rocks, and permeability alteration with mineral precipitation or dissolution. A suite of numerical simulators was exercised on a series of test problems that considered coupled thermal, hydraulic, geomechanical, and geochemical (THMC) processes. Problems were selected and designed to isolate selected coupled processes, to be executed on workstation class computers, and have simple but illustrative metrics for result comparisons. This paper summarizes the initial suite of seven benchmark problems, describes the code comparison activities, provides example results for problems and documents the capabilities of currently available numerical simulation codes to represent coupled processes that occur during the production of geothermal resources. Code comparisons described in this paper use the ISO (International Organization for Standardization) standard ISO-13538 for proficiency testing of numerical simulators. This approach was adopted for a recent code comparison study within the radiation transfer-modeling field of atmospheric sciences, which was focused on canopy reflectance models. This standard specifies statistical methods for analyzing laboratory data from proficiency testing schemes to demonstrate that the measurement results do not exhibit evidence of an unacceptable level of bias.

benchmark problems↗

Direct comparison between experiments and dislocation dynamics simulations of high rate deformation of single crystal copper

A long standing challenge in computational materials science is to establish a quantitative connection between the macroscopic properties of plastic deformation with the microscopic mechanisms of dislocations in crystalline materials. Although the discrete dislocation dynamics (DDD) simulation method has been developed for several decades with the goal of addressing this challenge, a one-to-one comparison between the DDD predictions on single crystal stress–strain curves and experimental measurements under identical conditions has not been possible to date. Such a comparison is an essential step towards establishing a dislocation-physics based theory of plasticity and a multiscale framework of the plastic behaviors of crystalline materials. Here we provide direct comparisons between the stress–strain curves of Cu single crystals under high strain rate loading in the [0 0 1] and [0 1 1] directions obtained from miniaturized desktop Kolsky bar experiments and those from DDD simulations under identical loading conditions. With an appropriate set of parameters, DDD simulations can produce stress–strain curves that are in reasonable agreement with the experimental results. However, the dislocation mobility values needed to achieve this agreement are an order of magnitude lower than expected based on previous measurements and atomistic simulations. We hypothesize that this discrepancy could be caused by drag forces from jogs and point defects produced during the plastic deformation. Cross-slip of screw dislocations is also found to be necessary to capture the experimental stress–strain behavior, especially for the [0 1 1] loading direction. Finally, this work provides an example of how direct comparisons between DDD simulations and experimental measurements can provide new insight into the fundamental mechanisms of plastic deformation.

36 MATERIALS SCIENCE↗

Pairwise comparisons of ten porcine tissues identify differential transcriptional regulation at the gene, isoform, promoter and transcription start site level

Highlights: •Transcriptome sequencing yielded 223 mill porcine RNA-seq reads, and 59,000 transcribed locations. •Establishment of unique transcription profiles for ten porcine tissues including four brain tissues. •Comparison of transcription profiles at gene, isoform, promoter and transcription start site level. •Highlights a high level of regulation of neuro-related genes at both gene, isoform, and TSS level. •Our results emphasize the pig as a valuable animal model with respect to human biological issues. -- Abstract: The transcriptome is the absolute set of transcripts in a tissue or cell at the time of sampling. In this study RNA-Seq is employed to enable the differential analysis of the transcriptome profile for ten porcine tissues in order to evaluate differences between the tissues at the gene and isoform expression level, together with an analysis of variation in transcription start sites, promoter usage, and splicing. Totally, 223 million RNA fragments were sequenced leading to the identification of 59,930 transcribed gene locations and 290,936 transcript variants using Cufflinks with similarity to approximately 13,899 annotated human genes. Pairwise analysis of tissues for differential expression at the gene level showed that the smallest differences were between tissues originating from the porcine brain. Interestingly, the relative level of differential expression at the isoform level did generally not vary between tissue contrasts. Furthermore, analysis of differential promoter usage between tissues, revealed a proportionally higher variation between cerebellum (CBE) versus frontal cortex and cerebellum versus hypothalamus (HYP) than in the remaining comparisons. In addition, the comparison of differential transcription start sites showed that the number of these sites is generally increased in comparisons including hypothalamus in contrast to other pairwise assessments. A comprehensive analysis of one of the tissue contrasts, i.e. cerebellum versus heart for differential variation at the gene, isoform, and transcription start site (TSS), and promoter level showed that several of the genes differed at all four levels. Interestingly, these genes were mainly annotated to the “electron transport chain” and neuronal differentiation, emphasizing that “tissue important” genes are regulated at several levels. Furthermore, our analysis shows that the “across tissue approach” has a promising potential when screening for possible explanations for variations, such as those observed at the gene expression levels.

60 APPLIED LIFE SCIENCES↗

A study of examiner accuracy in cartridge case comparisons. Part 2: Examiner use of the AFTE range of conclusions

Here, this report describes an analysis of how examiners used the Association of Firearm and Toolmark Examiners (AFTE) Range of Conclusions in a controlled study undertaken to estimate examiner error rates in comparing cartridge cases. Results of the error rate analysis are reported in [1]; this paper focuses on a broader analysis of how the entire collection of classification categories, especially those in the Inconclusive range, were used by the participating examiners. Volunteer active examiners with AFTE membership or working in laboratories that participate in Association of Crime Laboratory Directors (ASCLD) were provided with 15 sets of three known and one questioned cartridge cases fired from a collection of 25 new Ruger SR9 handguns. Remington 9-mm Luger (manufacturer designation L9MM3) ammunition was used and comparison sets were made up of cartridge cases fired within 100 cartridges of each other for each gun. Examiners were provided with a background survey, an answer sheet allowing for the AFTE Range of Conclusions, and return shipping materials. The participating examiners were provided with both same-source and different-source comparison sets allowing the study to assess both error rates. Responses were received from 218 participating examiners. The overall rate of false-negatives was estimated as 0.367 % from comparisons known to be from the same firearm but reported as eliminations. The overall rate of false-positives was estimated as 1.01 % from comparisons known to be from different firearms but reported as identifications. In the case of true different-source examinations, it is clear that the three Inconclusive categories and the Elimination category are not used consistently by all examiners. We identify five different apparent patterns of use of the AFTE Range of Conclusions scale, and discuss possible reasons for and implications of these differences.

99 GENERAL AND MISCELLANEOUS↗

Improving magnitude and phase comparison metrics for frequency response functions using cross-correlation and log-frequency shifting

This paper provides a new method for matching dominant features of Frequency Response Functions (FRFs). In particular, this paper proposes a slicing and shifting method where the key features (in this case, resonant amplitudes) of a baseline FRF are compared with a similar FRF using cross-correlation and a Log-Frequency Shift (LFS). Here, the goal is to provide an alternative to classic point-to-point methods for FRF comparison and instead to match the dominant features of two FRFs in a way similar to visual inspection. This enables existing FRF comparison metrics to then be applied with greater fidelity. Additionally, this paper introduces the Phase Similarity Metric (PSM) for comparing phases of two FRFs and illustrates the improvement of using LFS for phase comparisons as well. This paper uses a cantilever beam experiment in multiple configurations to provide a benchmark case for FRF comparison improvements.

42 ENGINEERING↗

Comparison of the Optical Connectivity Method to X-Ray spray measurements in the near field of a diesel injector

For diesel sprays, the primary breakup processes are only rarely understood due to the high optical density and the resulting difficulties to measure them with extremely high spatial and sufficient temporal resolution. The Optical Connectivity Method (OCM) has been proposed in the last years to allow the determination of the breakup length of the connected liquid core, thus giving a measurement quantity of the primary breakup. In this research, an improved optical setup of the OCM is applied to a three-hole test injector nozzle where several measurement techniques are compared currently under well-defined conditions up to 100 MPa injection pressure. In this work, the direct comparison with X-Ray measurements done at the Advanced Photon Source of the Argonne National Laboratory will be described. This allows an evaluation of the OCM technique and a comparison of the different measurement quantities in the first 500 μm range of the spray. The structure of the spray is measured by X-Ray phase contrast imaging and the fuel mass distribution is measured by X-Ray absorption imaging. A detailed comparison of the two X-Ray techniques and the OCM technique has been possible for the first time. It is found that the measurement data of the spray near field are very congruent with all three methods. Due to this comparison, the measurement of the non-perturbed length, which describes the distance from the nozzle orifice up to the point where the formation of surface disturbances is starting, by the OCM is validated for the first time. Within this non-perturbed length of the spray, the OCM signal is weak before it starts to illuminate from the scattering of the perturbed surface. Hence, the OCM technique can deliver two characteristic length scales, the non-perturbed length and the breakup length , characterizing the primary spray breakup.

33 ADVANCED PROPULSION SYSTEMS↗

Assessment of HRA method predictions against operating crew performance: Part II: Overall simulator data, HRA method predictions, and intra-method comparisons

This is the third in a series of four papers documenting two large-scale human reliability analysis (HRA) empirical studies – the International HRA Empirical Study and the US HRA Empirical Study. Here, the goal of the two studies was to develop an empirically-based understanding of the performance, strengths, and weaknesses of HRA methods by comparing HRA method predictions against actual operator performance in simulated accident scenarios on nuclear power plant (NPP) simulators. However, since in most cases only a single HRA team applied a given method in the International study, it was often difficult to separate analyst effects from variability in results related to the methods themselves. Since at least two HRA teams used each of the HRA methods in the US Study, intra-method comparisons were performed to identify method strengths and weaknesses independent of analyst specific effects where possible. This paper first summarizes the intra-method comparison results from the U.S. Study. Then, it discusses the reasons for the observed HRA predictive differences and the underlying methodological and guidance limitations that permitted the differences to arise. In the fourth paper, this information is combined wit h the results of the comparisons of method predictions to the actual crew data, from both the International and U.S. Studies, to develop the final conclusions about overall strengths and weaknesses of HRA methods.

97 MATHEMATICS AND COMPUTING↗

Comparison of TCDD-elicited genome-wide hepatic gene expression in Sprague–Dawley rats and C57BL/6 mice

Although the structure and function of the AhR are conserved, emerging evidence suggests that downstream effects are species-specific. In this study, rat hepatic gene expression data from the DrugMatrix database (National Toxicology Program) were compared to mouse hepatic whole-genome gene expression data following treatment with 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD). For the DrugMatrix study, male Sprague–Dawley rats were gavaged daily with 20 μg/kg TCDD for 1, 3 and 5 days, while female C57BL/6 ovariectomized mice were examined 1, 3 and 7 days after a single oral gavage of 30 μg/kg TCDD. A total of 649 rat and 1386 mouse genes (|fold change| ≥ 1.5, P1(t) ≥ 0.99) were differentially expressed following treatment. HomoloGene identified 11,708 orthologs represented across the rat Affymetrix 230 2.0 GeneChip (12,310 total orthologs), and the mouse 4 × 44K v.1 Agilent oligonucleotide array (17,578 total orthologs). Comparative analysis found 563 and 922 orthologs differentially expressed in response to TCDD in the rat and mouse, respectively, with 70 responses associated with immune function and lipid metabolism in common to both. Moreover, QRTPCR analysis of Ceacam1, showed divergent expression (induced in rat; repressed in mouse) functionally consistent with TCDD-elicited hepatic steatosis in the mouse but not the rat. Functional analysis identified orthologs involved in nucleotide binding and acetyltransferase activity in rat, while mouse-specific responses were associated with steroid, phospholipid, fatty acid, and carbohydrate metabolism. These results provide further evidence that TCDD elicits species-specific regulation of distinct gene networks, and outlines considerations for future comparisons of publicly available microarray datasets. - Highlights: ► We performed a whole-genome comparison of TCDD-regulated genes in mice and rats. ► Previous species comparisons were extended using data from the DrugMatrix database. ► Less than 15% of TCDD-regulated orthologs were common to mice and rats. ► Considerations for the comparison of publicly available datasets are described.

60 APPLIED LIFE SCIENCES↗

Is the Calcite-Water Interface Understood? Direct Comparisons of Molecular Dynamics Simulations with Specular X-ray Reflectivity Data

New insights into the structure of the calcite-water interface are obtained through direct model-independent comparison of multiple classical molecular dynamics (MD) simulations with high-resolution specular X-ray reflectivity (XR) data. This set of comparisons, with four different state-of-the-art force fields (including two non-polarizable, one polarizable, and one reactive force field), reveal new insights into the absolute accuracy of the simulated structures and the uniqueness of the XR-derived structural results. These four simulations, while qualitatively similar, have visibly distinct interfacial structure, and are distinguished through a quantitative comparison of the XR signals calculated from these simulations with experimental XR data. The results demonstrate that the simulated calcite-water interface structures, as a whole, are not consistent with the XR data (i.e., within their precision and accuracy). This disagreement is largely due to the simulation of the calcite lattice. The simulated interfacial water profiles show substantially different levels of agreement with the XR data. Of these, the rigid-ion model (RIM) simulations show the best consistency with the experimental XR data. Further model-dependent comparisons of the structural parameters that describe the interfacial structure (derived from both the MD simulations and the XR data) provide further insight into the sources of differences between these two approaches. Using the new insights from the RIM simulations, new structures of the calcite-water interface consistent with both the experimental data and the simulation are identified and compared to recent results.

Calcite-water interface↗

On possible variation in the cosmological Baryon fraction.

The fraction of matter that is in the form of baryons or dark matter could have spatial fluctuations in the form of baryon-dark matter isocurvature fluctuations. We use big bang nucleosynthesis calculations compared with observed light element abundances as well as galaxy cluster gas fractions to constrain cosmological variations in the baryon fraction. Light element abundances constrain spatial variations to be less than 26-27%, while a sample of 'relaxed' galaxy clusters shows spatial variations in gas fractions less than 8%. Larger spatial variations could cause differential screening of the primary cosmic microwave background anisotropies, leading to asymmetries in the fluctuations and ease some tension with the halo-star 7Li abundance. Fluctuations within our allowed bounds can lead to 'B-mode' CMB polarization anisotropies at a non-negligible level.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measured and Monte Carlo calculated k{sub Q} factors: Accuracy and comparison

Purpose: The journal Medical Physics recently published two papers that determine beam quality conversion factors, k{sub Q}, for large sets of ion chambers. In the first paper [McEwen Med. Phys. 37, 2179-2193 (2010)], k{sub Q} was determined experimentally, while the second paper [Muir and Rogers Med. Phys. 37, 5939-5950 (2010)] provides k{sub Q} factors calculated using Monte Carlo simulations. This work investigates a variety of additional consistency checks to verify the accuracy of the k{sub Q} factors determined in each publication and a comparison of the two data sets. Uncertainty introduced in calculated k{sub Q} factors by possible variation of W/e with beam energy is investigated further. Methods: The validity of the experimental set of k{sub Q} factors relies on the accuracy of the NE2571 reference chamber measurements to which k{sub Q} factors for all other ion chambers are correlated. The stability of NE2571 absorbed dose to water calibration coefficients is determined and comparison to other experimental k{sub Q} factors is analyzed. Reliability of Monte Carlo calculated k{sub Q} factors is assessed through comparison to other publications that provide Monte Carlo calculations of k{sub Q} as well as an analysis of the sleeve effect, the effect of cavity length and self-consistencies between graphite-walled Farmer-chambers. Comparison between the two data sets is given in terms of the percent difference between the k{sub Q} factors presented in both publications. Results: Monitoring of the absorbed dose calibration coefficients for the NE2571 chambers over a period of more than 15 yrs exhibit consistency at a level better than 0.1%. Agreement of the NE2571 k{sub Q} factors with a quadratic fit to all other experimental data from standards labs for the same chamber is observed within 0.3%. Monte Carlo calculated k{sub Q} factors are in good agreement with most other Monte Carlo calculated k{sub Q} factors. Expected results are observed for the sleeve effect and the effect of cavity length on k{sub Q}. The mean percent differences between experimental and Monte Carlo calculated k{sub Q} factors are -0.08, -0.07, and -0.23% for the Elekta 6, 10, and 25 MV nominal beam energies, respectively. An upper limit on the variation of W/e in photon beams from cobalt-60 to 25 MV is determined as 0.4% with 95% confidence. The combined uncertainty on Monte Carlo calculated k{sub Q} factors is reassessed and amounts to between 0.40 and 0.49% depending on the wall material of the chamber. Conclusions: Excellent agreement (mean percent difference of only 0.13% for the entire data set) between experimental and calculated k{sub Q} factors is observed. For some chambers, k{sub Q} is measured for only one chamber of each type--the level of agreement observed in this study would suggest that for those chambers the measured k{sub Q} values are generally representative of the chamber type.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-BRB-07: A Plan Comparison Tool to Ensure Robustness and Deliverability in Online-Adaptive Radiotherapy

Purpose: To develop a plan comparison tool that will ensure robustness and deliverability through analysis of baseline and online-adaptive radiotherapy plans using similarity metrics. Methods: The ViewRay MRIdian treatment planning system allows export of a plan file that contains plan and delivery information. A software tool was developed to read and compare two plans, providing information and metrics to assess their similarity. In addition to performing direct comparisons (e.g. demographics, ROI volumes, number of segments, total beam-on time), the tool computes and presents histograms of derived metrics (e.g. step-and-shoot segment field sizes, segment average leaf gaps). Such metrics were investigated for their ability to predict that an online-adapted plan reasonably similar to a baseline plan where deliverability has already been established. Results: In the realm of online-adaptive planning, comparing ROI volumes offers a sanity check to verify observations found during contouring. Beyond ROI analysis, it has been found that simply editing contours and re-optimizing to adapt treatment can produce a delivery that is substantially different than the baseline plan (e.g. number of segments increased by 31%), with no changes in optimization parameters and only minor changes in anatomy. Currently the tool can quickly identify large omissions or deviations from baseline expectations. As our online-adaptive patient population increases, we will continue to develop and refine quantitative acceptance criteria for adapted plans and relate them historical delivery QA measurements. Conclusion: The plan comparison tool is in clinical use and reports a wide range of comparison metrics, illustrating key differences between two plans. This independent check is accomplished in seconds and can be performed in parallel to other tasks in the online-adaptive workflow. Current use prevents large planning or delivery errors from occurring, and ongoing refinements will lead to increased assurance of plan quality.

60 APPLIED LIFE SCIENCES↗

Statistical Comparison of the Baseline Mechanical Properties of NBG-18 and PCEA Graphite

High-purity graphite is the core structural material of choice in the Very High Temperature Reactor (VHTR), a graphite-moderated, helium-cooled design that is capable of producing process heat for power generation and for industrial process that require temperatures higher than the outlet temperatures of present nuclear reactors. The Baseline Graphite Characterization Program is endeavoring to minimize the conservative estimates of as-manufactured mechanical and physical properties by providing comprehensive data that captures the level of variation in measured values. In addition to providing a comprehensive comparison between these values in different nuclear grades, the program is also carefully tracking individual specimen source, position, and orientation information in order to provide comparisons and variations between different lots, different billets, and different positions from within a single billet. This report is a preliminary comparison between the two grades of graphite that were initially favored in the two main VHTR designs. NBG-18, a medium-grain pitch coke graphite from SGL formed via vibration molding, was the favored structural material in the pebble-bed configuration, while PCEA, a smaller grain, petroleum coke, extruded graphite from GrafTech was favored for the prismatic configuration. An analysis of the comparison between these two grades will include not only the differences in fundamental and statistically-significant individual strength levels, but also the differences in variability in properties within each of the grades that will ultimately provide the basis for the prediction of in-service performance. The comparative performance of the different types of nuclear grade graphites will continue to evolve as thousands more specimens are fully characterized from the numerous grades of graphite being evaluated.

36 MATERIALS SCIENCE↗