Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cooling Load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Beam Commissioning Result of Polarized Target at SpinQuest

SpinQuest is a fixed-target experiment at Fermilab to measure the Drell-Yan process using transversely polarized NH$_3$ and ND$_3$ targets and unpolarized 120-GeV proton beam. In the Drell-Yan process, a quark in one scattering hadron and an anti-quark in the other hadron annihilate into a virtual photon and then decay into a muon (lepton) pair. The angular distribution of final-state muon pairs with respect to the target polarization is sensitive to the Sivers function of light antiquarks in the nucleon, which is one of the eight Transverse Momentum Dependent (TMD) parton distribution functions. The intensity of the proton beam is as high as $10^{12}$ protons/second, in order to accumulate the required statistics of Drell-Yan events. The polarized target system at SpinQuest has been carefully designed to accommodate such a high beam intensity. It is equipped with an evaporation refrigerator with a cooling power of around 5 W at 1 K. The target temperature is maintained at 1 K even under heat load caused by the proton beam and the DNP microwave. The target system and the spectrometer were commissioned with the proton beam from May through July 2024. The experimental setup of SpinQuest and the performance of the target system during the beam commissioning is reported.

Nakano, Kenichi [Virginia U.]↗

MSD CoP Webinar: Energy and AI

Context: This webinar was hosted by the MultiSector Dynamics Community of Practice (MSD CoP; https://multisectordynamics.org). Abstract: Projections of the need for new data centers to support Artificial Intelligence (AI) are large but highly uncertain. Recent projections indicate up to a 15% annual growth rate in data center electricity demand within the next 5-10 years. Given that most electric utilities are required to have a reserve margin of roughly the same magnitude as the projected growth in demand, these new data center loads could soon threaten resource adequacy and reliability unless data centers build their own generation, interruptible loads are negotiated, commensurate new capacity and/or transmission is built, or some combination of these options. Similarly, depending on the cooling technology and geographic location of new data centers, they could threaten water adequacy in water scarce regions. This webinar will provide an overview of the interactions between energy and AI and highlight two MSD projects exploring the grid and water implications of new data centers to support AI. Presenters : Dr. Casey Burleyson (Pacific Northwest National Laboratory); Dr. Stephanie Morris (Pacific Northwest National Laboratory); Kendall Mongird (Pacific Northwest National Laboratory) Moderator: Patrick M. Reed (MSD CoP Facilitation Team) This webinar was held on: June 16th, 2025 from 1-2 PM EST.

Artificial Intelligence↗

Energy and AI: Evaluating Future Grid and Water Stress Due to Data Centers

Projections of the need for new data centers to support Artificial Intelligence (AI) are large but highly uncertain. Recent projections indicate up to a 15% annual growth rate in data center electricity demand within the next 5-10 years. Given that most electric utilities are required to have a reserve margin of roughly the same magnitude as the projected growth in demand, these new data center loads could soon threaten resource adequacy and reliability unless data centers build their own generation, interruptible loads are negotiated, commensurate new capacity and/or transmission is built, or some combination of these options. Similarly, depending on the cooling technology and geographic location of new data centers, they could threaten water adequacy in water scarce regions. This presentation highlights the grid and water implications of new data centers to support AI.

Mongird, Kendall (ORCID:0000000328077088)↗

Characterization and Damping Control of Mechanical Connections to Improve Performance of Horn Stripline

Magnetic focusing horns are critical components for creating a stable beam of neutrinos for neutrino facilities, such as the Long Baseline Neutrino Facility (LBNF) and the Neutrinos and Main Injector (NuMI) beam lines at Fermilab. The pulsed magnetic horns are powered by high current electricity through long striplines. In addition to requirements for low inductance and voltage standoff, the striplines must survive in a harsh radiation environment for the operational life of the component, specified as the 100 million pulses requirement for LBNF. Each stripline assembly consists of four (eight layers that splits off to 2 pairs of four layers at the horn interface) layers of Al 6101-T6. As an electromechanical system, the stripline layers are bolted together with ceramic isolators for electrical insulation and connections must facilitate passive cooling and mechanical stability. The striplines experience vibrational force in addition to clamping force, repetitive thermal and electro-magnetic loading. The holes of stripline plates for ceramic joints represent one of the weak links for potential failure [1,2]. By characterizing the contact behavior of these joints and optimizing their damping properties through finite element analysis and experimental modal analysis, stripline performance and longevity can be improved. This study not only helps predict the behavior of the striplines but also improves their performance to meet the required operational lifetime.

Liu, Zunping [Fermilab]↗

Improving AHU Performance by Minimizing Approach Temperature, Reducing Air Maldistribution, and Efficiently Handling Sensible and Latent Loads (Phase 1 Interim Final Technical Report)

Residential air handling units (AHUs) have stayed the same in form and efficiency for the past 30+ years, with incremental improvements made to address safety, functionality, and energy-efficiency. The purpose of this research in Phase I, Topic 9a: Next Generation Residential Air Handlers, was to improve AHU performance by minimizing heat exchanger (HX) approach temperature, reducing air maldistribution, and developing alternative system configurations which more efficiently handle sensible and latent loads. In this research Optimized Thermal Systems (OTS) developed, modeled, and evaluated multiple alternative system concepts. A dual vapor compression system separate sensible and latent cooling (SSLC) concept was studied to inform work on alternative concepts and to show best-case performance benefit. System concepts included ejector enhanced vapor compression cycles, desiccant assisted dehumidification, dual evaporator SSLC, and alternative AHU HX configurations. A dual vapor compression system showed COP improvement of 20%, however, required additional components, increased unit size, and increased cost. Two types of ejector enhanced vapor compression cycles with dual evaporators improved system COP by 9 to 11%, and reduced AHU losses by as much as 18%, with design changes limited to the AHU, no unit physical size increase, and a moderate increase to system first cost. Desiccant assisted air-conditioning required increased air flow rate resulting in higher fan power and the desiccant wheel increased sensible heat load leading to increased compressor power and reduced system COP. Dual evaporator cycles were found to degrade performance due to increased expansion losses. Optimized single slab HX designs used in place of the traditional A-coil HX led to 44–49% reduction in aluminum, 47–60% less refrigerant charge, and improved HX velocity distribution.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydrogen station in situ back-to-back fueling data for design and modeling

Hydrogen technologies are rapidly spreading, with significant attention to the mobility sector requiring a robust and widespread fueling infrastructure. Hydrogen stations are indeed fundamental to transitioning from pilot projects towards large-scale implementation in many countries. Operating under extreme conditions, the new stations need more informed designs and equipment to meet the growing demand and their more frequent utilization. Via a set of experimental research activities and investigated scenarios carried out at the Cal State LA Hydrogen Research and Fueling Facility, here this paper shares a novel and comprehensive set of data collected over a period of one year on fueling events frequency and refueling process station behaviors. A performance evaluation of the station is presented under different load scenarios in severe conditions during "back-to-back fuelings", with monitoring of fundamental parameters for infrastructure sizing, including dynamic cooling response, pressure levels, thermodynamics, and the state of charge of the vehicle. The presented data analysis could surely contribute as closer-to-reality inputs for a variety of station performance modeling tools.

08 HYDROGEN↗

helios: An R package to process heating and cooling degrees for GCAM

helios is an open-source R package that estimates population-weighted heating and cooling degree-hours (HDH and CDH) and degree-days (HDD and CDD) at various temporal (e.g., energy dispatch segments, monthly, yearly) and spatial scales (e.g., U.S. states, global political regions, countries). The degree hour and degree day outputs from helios are used to inform electricity demand load in the Global Change Analysis Model (GCAM) as well as in GCAM-USA (which is the version of GCAM with U.S. state-level details). helios uses a workflow with four steps: processing raw data; calculating heating and cooling degrees; visualizing performance diagnostics; and outputing results in various formats. There are two sources of widely-used climate data compatible with helios: (1) hourly climate data with 12-km resolution that are dynamically downscaled with the Weather Research and Forecasting (WRF) model and projected using a thermal global warming (TGW) approach; and (2) daily climate data with 0.5-degree resolution from the Coupled Model Intercomparison Project (CMIP) that is bias-adjusted and statistical downscaled by the Inter-Sectoral Impact Model Intercomparison Project (ISIMIP). In summary, helios is a model that standardizes methodology of heating and cooling degrees-hours and degree-days using publicly available data and advance the understanding of the impact of spatial and temporal temperature variability on building energy services.

97 MATHEMATICS AND COMPUTING↗

Thermal Modeling and Limitations for Power Electronics Embedded in Medium-Voltage Cables

As next-generation energy technologies gain traction and power demand increases, the existing electrical infrastructure faces significant stress, prompting innovative solutions to enhance the grid's capacity and lifespan. This work explores the possibility of embedding medium-voltage (MV) power electronics directly inline with the cable, and the resulting thermal challenges. Since the majority of power distribution cables installed in the U.S. are passively cooled, the work focuses primarily on passive cooling, with an emphasis on the limitations of axial heat spreading within the cable. To date, literature on axial spreading of high incident heat loads on cables and cable environments is limited, typically reporting cases with <10 W of incident heat load. This work will explore the considerations, limits, and tradeoffs of cable-embedded heat loads significantly larger than the cable losses. Both external and internal effects are modeled analytically in nondimensional terms via a Biot number analysis, allowing fundamental limits and tradeoffs to be derived. The work culminates in the design and experimental validation of a cable-embedded thermal system capable of passively dissipating 300 W of heat from a coaxial SiC mosfet switch module over a length of 20 cm, thus validating the possibility of MV cable-embedded power electronics from a thermal standpoint.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Creep Behavior of Compact γ′-γ″ Coprecipitation Strengthened IN718-Variant Superalloy

The development of high-temperature heavy-duty turbine disk materials is critical for improving the overall efficiency of combined cycle power plants. An alloy development strategy to this end involves superalloys strengthened by ‘compact’ γ′-γ″ coprecipitates. Compact morphology of coprecipitates consists of a cuboidal γ′ precipitate such that γ″ discs coat its six {001} faces. The present work is an attempt to investigate the microstructure and creep behavior of a fully aged alloy exhibiting compact coprecipitates. We conducted heat treatments, detailed microstructural characterization, and creep testing at 1200 °F (649 °C) on an IN718-variant alloy. Our results indicate that aged IN718-27 samples exhibit a relatively uniform distribution of compact coprecipitates, irrespective of the cooling rate. However, the alloy ruptured at low strains during creep tests at 1200 °F (649 °C). At 100 ksi (689 MPa) load, the alloy fails around 0.1% strain, and 75 ksi (517 MPa) loading causes rupture at 0.3% strain. We also report extensive intergranular failure in all the tested samples, which is attributed to cracking along grain boundary precipitates. The results suggest that while the compact coprecipitates are indeed thermally stable during thermomechanical processing, the microstructure of the alloy needs to be optimized for better creep strength and rupture life.

36 MATERIALS SCIENCE↗

Towards a Techno-Economic Analysis of PCM Integrated Hybrid HVAC Systems

Thermal end uses dominate building energy consumption and are a major driver of peak demand. As heating is electrified, peak electrical power required will surge, prompting a need for innovative HVAC system designs and controls.These designs must incorporate novel technologies at the component level and new integration techniques at the system level. One such possibility involves the addition of thermal energy storage (TES) in heating and cooling equipment using a phase change material (PCM) heat exchanger. Here, thermal energy storage via phase change can be used to shift the HVAC system loads to times of lower electricity cost, reduced carbon intensity, and greater energy efficiency. Most of the current utilization of PCM in buildings involves passive components. By actively controlling when heat is stored and released from PCM, we can optimize the building HVAC system to cost-effectively meet consumer needs with the flexibility to draw on renewable energy resources when they are abundant and available. While this combination of technologies is promising in theory, simulation-based evaluation of a prototype can be difficult due to the modeling requirements at the component level and the large number of possible configurations and operating modes at the system level. To conduct this evaluation, we use the Modelica language for modeling and simulation because it enables users to represent the important physics of the problem, interchange and rearrange components in an efficient manner, and implement a range of control configurations. In this work, we considered three case studies: a portable building, a large commercial retail store, and a multifamily residential apartment unit. Each of these employs a different system design, ranging from a single package vertical unit incorporating PCM to a central plant with independent heat pump, evaporative cooling, and thermal energy storage components. This paper describes the technologies in question, presents modeling at the component and system levels, and demonstrates building energy and demand charge cost savings with local time-of-use tariffs in a hot-dry climate.

Helmns, Dre↗

Top Loading Helium Cryostat Integrated with High-Pressure Cell with Fast Remote Pressure Control (Final Report for SBIR Phase 1)

A large number of physical phenomena, such as superconductivity and quantum critical phenomena, often appear only at very low temperatures below 5 K. There is an immense interest to investigate these phenomena at high pressure as a means of tuning interatomic distances, and thus the interaction parameters controlling these phenomena, in a continuous and controlled fashion. The current P-T condition for neutron scattering experiments are limited to either relatively low pressures of about 2 GPa at temperatures below 5 K, or to relatively high temperatures at pressures or tens of GPa. The purpose of this research is to develop neutron sample environment instrumentation for reaching 10-20 GPa at 1-2K with rapid and reliable online pressure and temperature control (i.e. without having to interrupt the experiment). The ultimate goal of the project is to design an integrated fast-cooling low-temperature sample environment cryogenic system compatible with state of the art neutron diamond anvil cells suitable for single-crystal neutron scattering experiments for temperatures down to 2K and pressures of several tens of GPa. The integrated system will consist of top-loading Helium flow cryostat with in-situ sample alignment mechanisms, large-volume diamond anvil cells (DAC) made from novel superalloy Pascalloy and optimized for fast cooling and heating, and a compact remote pressure control mechanism for the DAC based on a novel concept of inflatable bellows integrated with a lever-arm based force amplifier. In Phase I, we have designed, manufactured, and tested prototypes of the novel compact force-amplified pneumatic pressure control mechanism for Neutron Diamond Anvil Cell (nDAC), which allows to use pneumatic bellows system for smooth remote pressure control in the nDAC inside a top-loading cryostat with bore size of 70 mm or larger. This allows significant minimum temperature decrease in remotely controlled nDAC from 5-10 K down to 2 K. We also studied mechanical properties of a novel non-magnetic superalloy Pascalloy with different heat-treatment conditions and preliminary results indicate that up to date this is probably the strongest and most suitable material for making more compact and lightweight cryogenic nDACs for neuron scattering experiments at extreme conditions, allowing much faster cooling and heating. Potential applications: The new developments will allow to create a wide range of compact Diamond Anvil Cells for neutron diffraction which can reach several tens of GPA pressure at 2-4 K while preserving accurate remote pressure control capabilities. The new concepts can be used for developing sample environment instrumentation outside the neutron scattering field. The new development have very strong potential for expanding experimental capabilities in materials sciences and have high commercialization potential. The proposed new cryogenic high-pressure system or any of its individual components will be in high demand not only in neutron scattering facilities, but also at synchrotron beamlines and other high-pressure research facilities around the world.

36 MATERIALS SCIENCE↗

Effect of Heat Treatment on Microstructure and Mechanical Property of 316L Stainless Steel Produced by Laser Powder Bed Fusion

The advanced non-light water reactor designs (Gen IV reactors), including molten salt/ very high temperature/ sodium-cooled and lead-cooled fast reactors, typically operate at higher temperatures and more extreme radiation conditions than light water reactors. An intrinsic part of the deployment and progress of Gen IV reactor designs is selecting the most suitable structural material for a specific application. Additive manufacturing (AM), a fairly new process of making physical, three-dimensional objects from a computer design file, is going to completely change the way of design, build and certify nuclear systems. It offers a range of opportunities to produce complex geometries from existing materials, offers new routes for processing of previously difficult to process materials, allows for design of new high-performance materials, and finally facilitates hybridization of dissimilar materials. This emerging technology has successfully produced cars, wind turbine blade molds and even live cells. It could also open up big opportunities for the nuclear industry to quickly deploy technologies at a fraction of the cost. So far, AM techniques have been preliminarily applied in the field of nuclear reactors, including the classical parts such as the pressure vessel of a small reactor with 508-III steel, the bottom nozzle of a fuel assembly with 304L steel, the fuel cladding with zirconium alloy and the integrated impeller of a pump and the multi-channel valve body with 316L steel [6,7]. The AM applications for operating nuclear reactors started in auxiliary plant components and have slowly migrated to metallic reactors and core components, but many of these are not safety critical components. Although many parts used for nuclear reactors have been fabricated by AM techniques, practical applications in engineering are still a long way off due to the uncertainty factors focused on the processing, material properties, analysis methods and application standards, which feeds the safety and life-cycle of the nuclear reactor. Due to rapid, repeated heating and cooling during production, a high dislocation density was present in the AM material. This microstructure feature is unstable at elevated temperature while high temperature is one of the typical operation environments for nuclear reactors. Thus, it is important to understand the thermal effect on the microstructure of AM material. The objectives of this study are to investigate the effect of heat treatment on the microstructure and mechanical properties of 316L stainless steel produced by laser powder bed fusion additive manufacturing, and to determine an appropriate heat treatment practice that will be applied to the lightweight AM lattice-structured material with the same chemistry. The heat treatment study consisted of annealing the samples at a temperature range of 800 to 1200 oC with a 50 oC increment for different times (1-24 hours), followed by vacuum or air cooling. Microstructural characterization was carried out by Scanning Electron Microscope (SEM). Grain size and crystallographic orientation were investigated by Electron Backscatter Diffraction (EBSD). Vickers hardness tests with a 0.5 kg load were employed to determine the hardness of samples after different heat treatments. After heat treatment, the random crystallographic orientation was preserved, and the volume fraction of high-angle grain boundaries (grain boundary misorientation =15 oC) remained the same. The dislocation density decreased with annealing temperature due to recovery. The fine subgrain structures in the as-printed specimen were quite stable up to 1200 oC. Minimal recrystallization was observed up to 1200 oC. Recrystallization initiated only after 8.5 hours at 1200 oC. The SEM images did not show obvious dependence of microstructure on cooling rate. The hardness of the specimens decreased with increasing annealing temperature as a result of the decrease in dislocation density. It is interesting to note that the AM material showed very similar hardness to the wrought material when annealing at similar temperature, although the microstructures are very different. Annealing at 1050 oC for 1 hour followed by air cooling was selected as the heat treatment procedure for the lattice designed lightweight AM 316L material.

36 MATERIALS SCIENCE↗

Evaluating the energy impact potential of energy efficiency measures for retrofit applications: A case study with U.S. medium office buildings

Quantifying the energy savings of various energy efficiency measures (EEMs) for an energy retrofit project often necessitates an energy audit and detailed whole building energy modeling to evaluate the EEMs; however, this is often cost-prohibitive for small and medium buildings. In order to provide a defined guideline for projects with assumed common baseline characteristics, this paper applies a sensitivity analysis method to evaluate the impact of individual EEMs and groups these into packages to produce deep energy savings for a sample prototype medium office building across 15 climate zones in the United States. We start with one baseline model for each climate zone and nine candidate EEMs with a range of efficiency levels for each EEM. Three energy performance indicators (EPIs) are defined, which are annual electricity use intensity, annual natural gas use intensity, and annual energy cost. Then, a Standard Regression Coefficient (SRC) sensitivity analysis method is applied to determine the sensitivity of each EEM with respect to the three EPIs, and the relative sensitivity of all EEMs are calculated to evaluate their energy impacts. For the selected range of efficiency levels, the results indicate that the EEMs with higher energy impacts (i.e., higher sensitivity) in most climate zones are high-performance windows, reduced interior lighting power, and reduced interior plug and process loads. However, the sensitivity of the EEMs also vary by climate zone and EPI; for example, improved opaque envelope insulation and efficiency of cooling and heating systems are found to have a high energy impact in cold and hot climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and characterization of “flow-cell” integrated-flow active cooling for high-average-power ceramic optics

We used COMSOL Multiphysics to design a prototype actively cooled “flow-cell” substrate targeted at high-average-power applications, fabricated the prototype from cordierite ceramic, and tested the substrate under load in our thermal loading test stand. Sub-aperture testing revealed average-power handling up to 3.88-W/cm 2 absorbed power density, in excellent agreement with model predictions. Gratings fabricated on 2-in.-diam cordierite coupons were subjected to laser-damage testing and showed a damage threshold of 250 mJ/cm 2 .

47 OTHER INSTRUMENTATION↗

A Scalable Hardware-and-Human-in-the-Loop Grid-interactive Efficient Building Equipment Performance Dataset

This project developed a publicly available, high-fidelity dataset about the interactions among humans, homes, and heat pumps supporting grid interactive efficient buildings to balance demand on the grid with comfort for occupants. Laboratory measurements and simulations of the hardware capture the second-scale electric power dynamics of heat pumps providing grid services like load shifting and load shedding. Field measurements, behavior tracking, and qualitative surveys of people in their homes over multiple years—including experimentally adjusting the heating and cooling system to provide grid services—to capture the reciprocal effect of human behavior on grid services, and grid services on human comfort. Taken together, these data capture the complete Hardware and Human in the loop system for residential heat pumps, reducing large uncertainties in simulation for design, and models for control of heat pumps, and grid-interactive buildings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dual Impacts of Space Heating Electrification and Climate Change Increase Uncertainties in Peak Load Behavior and Grid Capacity Requirements in Texas

Around 60% of households in Texas currently rely on electricity for space heating. As decarbonization efforts increase, non‐electrified households could adopt electric heat pumps, significantly increasing peak (highest) electricity demand in winter. Simultaneously, anthropogenic climate change is expected to increase temperatures, the potential for summer heat waves, and associated electricity demand for cooling. Uncertainty regarding the timing and magnitude of these concurrent changes raises questions about how they will jointly affect the seasonality of peak demand, firm capacity requirements, and grid reliability. This study investigates the net effects of residential space heating electrification and climate change on long‐term demand patterns and load shedding potential, using climate change projections, a predictive load model, and a direct current optimal power flow (DCOPF) model of the Texas grid. Results show that full electrification of residential space heating by replacing existing fossil fuel use with higher efficiency heat pumps could significantly improve reliability under hotter futures. Less efficient heat pumps may result in more severe winter peaking events and increased reliability risks. As heating electrification intensifies, system planners will need to balance the potential for greater resource adequacy risk caused by shifts in seasonal peaking behavior alongside the benefits (improved efficiency and reductions in emissions).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design, fabrication, and testing of a water-cooled tungsten-foam high-heat flux plasma-facing module

Here, we present a comprehensive study detailing the design, fabrication and testing a new modular “finger” component, featuring a hexagonal tungsten foam armor tile bonded to the top surface of the water-cooled finger unit. The mechanical, thermal, and particle transport properties of the tungsten foam armor were determined for a wide range of porosity and cell size, and then combined in an equivalent solid material with “effective” properties suitable for large-scale simulations. A series of 3-D multiphysics simulations for coupled thermal and mechanical behavior of the “finger” module are used to optimize the design before fabrication. The simulation results show that, for the expected experimental conditions, a safe range of heat flux and foam porosity is possible for both water-cooling and helium-cooling. Based on these multiphysics simulations, an optimum finger cooling module has been fabricated at Ultramet, Inc. A series of experiments were designed to study the thermomechanical performance of the “finger” unit under steady-state and transient thermal loading at surface heat flux up to 16 MW/m 2 in the High Energy Flux Test facility (HEFTY) at UCLA. Testing conditions included low-power, steady-state plasma exposure at 6 MW/m 2 , followed by severe high heat flux cycles at 16 MW/m 2 . Results of these tests are explained through comparisons with multiphysics simulations. To eliminate the effects of thermomechanical damage carried out on a module on its thermo-mechanical response on a subsequent test, three different yet identically designed and fabricated finger modules were tested. The results show that the current design is capable of cooling the walls of fusion devices at surface heat flux up to 6 MW/m 2 without failure, and that the failure heat flux limit is below 16 MW/m 2 .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling of Liquid Hydrogen Tank Cooled with Para-Orthohydrogen Conversion

With the accelerating development of liquid-hydrogen storage facilities, the problem of boil-off hydrogen losses becomes very important. A promising method to reduce these losses is to utilize the endothermic para-orthohydrogen conversion of vented hydrogen, which can effectively decrease heat loads on a hydrogen tank. To model such a process, a hybrid computational model has been developed, based on the application of computational fluid dynamics for an ullage space, where knowledge of thermal stratification is important, and reduced-order models for other system elements. The simulation results for a spheroidal tank in selected conditions indicated a 10–25% reduction of boil-off losses due to cooling produced by vented hydrogen undergoing para-ortho-conversion.

08 HYDROGEN↗