Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cryogenic cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Performance and durability of HgI2 X-ray detectors for space missions

Considerable progress has been achieved recently in HgI2 detector fabrication technology and amplification electronics. An energy resolution of 198 eV (full width at half maximum) has been obtained for the Mn k-alpha line of 5.9 keV in a practical X-ray probe without the use of cryogenic cooling. Detectors prepared with Parylene-C encapsulation have demonstrated perfect reliability in two-year tests under high vacuum and temperature and bias cycling. Other HgI2 detectors have been used to demonstrate proton-radiation-damage resistance to levels of 10 to the 12 protons/sq cm at 10.7 MeV. It is concluded that HgI2 detectors are suitable for the ordinary requirements of energy dispersive detectors in X-ray spectroscopy systems.

Iwanczyk, J. S.↗

Spike train generation and current-to-frequency conversion in silicon diodes

A device physics model is developed to analyze spontaneous neuron-like spike train generation in current driven silicon p(+)-n-n(+) devices in cryogenic environments. The model is shown to explain the very high dynamic range (0 to the 7th) current-to-frequency conversion and experimental features of the spike train frequency as a function of input current. The devices are interesting components for implementation of parallel asynchronous processing adjacent to cryogenically cooled focal planes because of their extremely low current and power requirements, their electronic simplicity, and their pulse coding capability, and could be used to form the hardware basis for neural networks which employ biologically plausible means of information coding.

Coon, D. D.↗

Results of dynamic testing of GP-B spherical gyroscopes

Laboratory tests of the spherical electrostatically levitated cryogenically cooled coated gyroscope being developed for the Gravity Probe B (GP-B) spacecraft (Bardas et al., 1986) are reported. Spin speed and the dc components of the trapped magnetic field are measured with three orthogonal pickup loops attached to SQUID detectors as the levitated gyro is brought up to speed by an He gas jet. Data on the spin-vector time history, mass unbalance, higher rotor-shape harmonics, and spin-vector position are presented in extensive graphs and characterized in detail, and a mathematical model of the electrostatic suspension torques is derived. Prototype gyro 86-4 is found to have mass unbalance within the range required for the GP-B mission (to detect the geodetic and motional effects predicted by general relativity theory).

Keiser, G. M.↗

LDR cryogenics

A brief summary from the 1985 Large Deployable Reflector (LDR) Asilomar 2 workshop of the requirements for LDR cryogenic cooling is presented. The heat rates are simply the sum of the individual heat rates from the instruments. Consideration of duty cycle will have a dramatic effect on cooling requirements. There are many possible combinations of cooling techniques for each of the three temperatures zones. It is clear that much further system study is needed to determine what type of cooling system is required (He-2, hybrid or mechanical) and what size and power is required. As the instruments, along with their duty cycles and heat rates, become better defined it will be possible to better determine the optimum cooling systems.

Nast, T.↗

Introduction to the Infrared Space Observatory (ISO)

The Infrared Space Observatory (ISO) is an astronomical satellite, which will operate at infrared wavelengths (2.5 to 200 microns) for a period of at least 18 months. Imaging, spectroscopic, photometric and polarimetric observations will be obtained by four scientific instruments in the focal plane of its 60-cm diameter, cryogenically-cooled telescope. Two-thirds of ISO's observing time will be available to the astronomical community. ISO is a fully approved and funded project of the European Space Agency (ESA) with a foreseen launch date of May 1993.

Kessler, M. F.↗

SIRTF: Probing the dark corners of the galaxy

The Space Infrared Telescope Facility (SIRTF) is planned for launch by NASA in the mid-1990's. It will be a cryogenically-cooled observatory for infrared astronomy and will carry several focal plane instruments which will provide a wide range of imaging, photometric, and spectroscopic capabilities. SIRTF will build on the scientific and technical progress of the successful IRAS mission and take the next step in the exploration of the Universe at infrared wavelengths. Most of the observing time during the five-to-ten year SIRTF mission will be available to General Investigators, so there will be ample opportunities for the pursuit of problems originating from within the Space Life Sciences community. Here, a review is given of the capabilities of SIRTF for this style of investigation, using the study of carbon in the Galaxy as a specific example. The very high sensitivity of SIRTF's spectrometers to diffuse emission will allow studies of carbon in both the gaseous and solid phase in the interstellar medium and should be of particular importance for the identification of the carbon-bearing macromolecules believed to be responsible for the emission features identified in the near infrared. SIRTF will also carry out studies of a wide variety of evolved stars which are returning gas and solid phase carbon to the interstellar medium and contribute to our understanding of the carbon budget in the Galaxy. These studies in the area of galactic astronomy will be complemented by detailed investigations of carbon-bearing compounds in solar system objects, including the surfaces of distant asteroids and cometary nuclei which are too faint to be studied in any other way.

Werner, Michael W.↗

Interactive remote control for an STS-based superfluid helium transfer demonstration

NASA's superfluid helium on-orbit transfer (SHOOT) experiment, which is a Shuttle-based demonstration of the technology required to service cryogenically cooled satellites in space, is described. The SHOOT Command and Monitoring System software, developed on Macintosh II, will provide a near-real-time highly interactive interface making it possible to control the experiment and to analyze and display its telemetry. User interface is discussed as well as conversion functions, and hardware.

Shapiro, Jeff C.↗

Space Infrared Telescope Facility (SIRTF) science instruments

Concepts of scientific instruments designed to perform infrared astronomical tasks such as imaging, photometry, and spectroscopy are discussed as part of the Space Infrared Telescope Facility (SIRTF) project under definition study at NASA/Ames Research Center. The instruments are: the multiband imaging photometer, the infrared array camera, and the infrared spectograph. SIRTF, a cryogenically cooled infrared telescope in the 1-meter range and wavelengths as short as 2.5 microns carrying multiple instruments with high sensitivity and low background performance, provides the capability to carry out basic astronomical investigations such as deep search for very distant protogalaxies, quasi-stellar objects, and missing mass; infrared emission from galaxies; star formation and the interstellar medium; and the composition and structure of the atmospheres of the outer planets in the solar sytem.

Ramos, R.↗

FIRAS optical alignment and performance during vibration qualification and cryogenic cycling

NASA's Cosmic Background Explorer (COBE) is designed to investigate the Cosmic Background Radiation (CBR), that permeates the universe as a consequence of the Big Bang. This 3 degree Kelvin radiation is a fossil that contains much information about the early universe. The Far Infrared Absolute Spectrophotometer (FIRAS), will investigate the spectral isotropy of this ancient remnant and look for clues as to the subsequent evolution of the universe. The instrument is a cryogenically cooled, modified Michelson interferometer which operates in the 1 cm to 100 micron wavelength range. FIRAS is designed to provide absolute spectral information, therefore, all possible perturbations to the instrument response must be investigated to minimize distortions of the data. This paper discusses the methodology and resultant variations in the instrument performance noted during room temperature, and liquid nitrogen, (LN2) temperature vibration qualification. Reference alignment shifts in critical components such as the instrument wire-grid beamsplitter are correlated to changes in the instrument spectral response.

Hagopian, John G.↗

High precision photometry with fiber optics

This paper discusses the issues involved in measurements made with high-precision multichannel photometers that use cryogenically cooled detectors and optical fibers to bring the light from the star images to the dewar and then to the detectors. The use of optical fibers introduces photometric errors. Measurements are presented of the errors caused by small changes in the position of the image on the fiber.

Borucki, W. J.↗

Cryo-mechanical tests of Ames 24E2 IR-black coating

In addition to the ambient condition tape test, five mechanical tests of the IR-black coating, Ames 24E2, were performed at either liquid helium or liquid nitrogen temperatures. Tensile strain in the coating at liquid nitrogen temperature was measured up to values of 4E-3, both before and after the coating was cycled down to liquid helium temperature. When applied to an aluminum substrate which was then bent in liquid nitrogen, the aluminum substrate always failed (permanently deformed) well before the coating failed. Sinusoidal accelerations up to 45 Gs in liquid nitrogen and 25 Gs in liquid helium did not crack or otherwise visibly damage the coating. Both sinusoidal and random acceleration at about 90 K of a representative baffle vane structure, at frequencies from 10 to 2000 Hz and up to 15 Gs, did not damage the coating, even at the intersection of a baffle with the telescope tube. Thus on a macroscopic level, cryogenic cooling and various levels of acceleration and strain did not affect this coating. However, on a microscopic scale, some loose particles were found associated with several tests. Outgassing data are also given.

Smith, Sheldon M.↗

Space Infrared Telescope Facility (SIRTF) implementation plans

This paper describes the Space Infrared Telescope Facility (SIRFT) mission planned by NASA for a launch by a Titan IV launch vehicle near the end of this decade. Special attention is given to the SIRFT's scientific goals, instruments, and technology. The cryogenically cooled SIRFT will utilize three scientific instruments, the Infrared Array Camera, the Infrared Spectrograph, and the Multiband Imaging Photometer for SIRFT and will achieve sensitivities 100 to 10,000 times greater than previous space telescope missions. During its five or six years of operation, SIRFT is expected to yield information on the formation and evolution of galaxies and stars and the solar-system phenomena and supernovae, as well as on the formation of other solar systems.

Spehalski, Richard J.↗

System requirements and design for the Space Infrared Telescope Facility (SIRTF)

The Space Infrared Telescope Facility (SIRTF) is the fourth in NASA's series of Great Observatories and will feature a one-meter class telescope in high earth orbit. Planned for launch around the turn of the century, the lifetime of this cryogenically cooled observatory will be approximately five years. This paper presents an overview of the current status of the requirements and design for SIRTF. This iterative process is described, and some examples are drawn from the upper end of the hierarchy.

Mclaughlin, William I.↗

Use of mercuric iodide X-ray detectors with alpha backscattering spectrometers for space applications

The authors present X-ray fluorescence (XRF) spectra of different extraterrestrial samples taken with a mercuric iodide (HgI2) spectrometer inserted into an alpha backscattering instrument identical to that used in the Soviet Phobos mission. The results obtained with the HgI2 ambient temperature detector are compared with those obtained using an Si(Li) cryogenically cooled detector. Efforts to design an optimized instrument for space application are also described. The results presented indicate that the energy resolution and sensitivity of HgI2 detectors are adequate to meet the performance needs of a number of proposed space applications, particularly those in which cooled silicon X-ray detectors are impractical or even not usable, such as for the target science programs on geoscience opportunities for lunar surface, Mars surface, and other comet and planetary missions being planned by NASA and ESA.

Iwanczyk, J. S.↗

Nighttime reactive nitrogen measurements from stratospheric infrared thermal emission observations

IR thermal emission spectra of the earth's atmosphere in the 700-2000/cm region were obtained with a cryogenically cooled high-resolution interferometer spectrometer on a balloon flight from Palestine, Texas, on September 15-16, 1986. The observations exhibit spectral features of a number of stratospheric constituents, including important species of the reactive nitrogen family. An analysis of the observed data for simultaneously measured vertical distributions of O3, H2O, N2O, NO2, N2O5, HNO3, and ClONO2 is presented. These measurements permit the first direct determination of the nighttime total reactive nitrogen concentrations, and the partitioning of the important elements of the NO(x) family. Comparisons of the total reactive nitrogen budget are made with the measurements by the ATMOS experiment and with the predictions of one-dimensional and two-dimensional photochemical models.

Abbas, Mian M.↗

The high temperature superconductivity space experiment

The history and the current status of the high temperature superconductivity space experiment (HTSSE) initiated in 1988 are briefly reviewed. The goal of the HTSSE program is to demonstrate the feasibility of incorporating high temperature superconductivity (HTS) technology into space systems. The anticipated payoffs include the development of high temperature superconductor devices for space systems; preparation and space qualification of a cryogenically cooled experimental package containing HTS devices and components; and acquisition of data for future space experiments using more complex HTS devices and subsystems. The principal HTSSE systems and devices are described.

Webb, Denis C.↗

Cryogenic focussing, ohmically heated on-column trap

A procedure is described for depositing a conductive layer of gold on the exterior of a fused-silica capillary used in gas chromatography. By subjecting a section of the column near the inlet to a thermal cycle of cryogenic cooling and ohmic heating, volatile samples are concentrated and subsequently injected. The performance of this trap as a chromatographic injector is demonstrated. Several additional applications are suggested and the unique properties of this device are discussed.

Springston, Stephen R.↗

Cryo-mechanical tests of Ames 24E2 IR-black coating

In addition to the ambient condition tape test, five mechanical tests of the IR-black coating, Ames 24E2, were performed at either liquid helium or liquid nitrogen teperatures. Tensile strain in the coating at liquid nitrogen temperature was measured up to values of 4E-3, both before and after the coating was cycled down to liquid helium temperature. When applied to an aluminum substrate which was then bent in liquid nitrogen, the aluminum substrate always failed (permanently deformed) well before the coating failed. Sinusoidal accelerations up to 45 Gs in liquid nitrogen and 25 Gs in liquid helium did not crack or otherwise visibly damage the coating. Both sinusoidal and random acceleration at about 90 K of a representative baffle vane structure, at frequencies from 10 to 2000 Hz and up to 15 Gs, did not damage the coating, even at the intersection of a baffle with the telescope tube. Thus on a macroscopic level, cryogenic cooling and various levels of acceleration and strain did not affect this coating. However, on a microscopic scale, some loose particles were found associated with several tests. Outgassing data are also given

Smith, Sheldon M.↗