Cryo-mechanical tests of Ames 24E2 IR-black coating

In addition to the ambient condition tape test, five mechanical tests of the IR-black coating, Ames 24E2, were performed at either liquid helium or liquid nitrogen teperatures. Tensile strain in the coating at liquid nitrogen temperature was measured up to values of 4E-3, both before and after the coating was cycled down to liquid helium temperature. When applied to an aluminum substrate which was then bent in liquid nitrogen, the aluminum substrate always failed (permanently deformed) well before the coating failed. Sinusoidal accelerations up to 45 Gs in liquid nitrogen and 25 Gs in liquid helium did not crack or otherwise visibly damage the coating. Both sinusoidal and random acceleration at about 90 K of a representative baffle vane structure, at frequencies from 10 to 2000 Hz and up to 15 Gs, did not damage the coating, even at the intersection of a baffle with the telescope tube. Thus on a macroscopic level, cryogenic cooling and various levels of acceleration and strain did not affect this coating. However, on a microscopic scale, some loose particles were found associated with several tests. Outgassing data are also given

Smith, Sheldon M.↗

Thermal systems analysis for the Space Infrared Telescope Facility dewar

Thermal systems analysis models were used to design SFHe cooled dewar for the Space Infrared Telescope Facility (SIRTF), a 1 m class cryogenically cooled observatory for IR astronomy. The models are capable of computing both the heat leaks into the dewar and the operating temperature of a SFHe tank. The models are aimed at predicting the ability of the SIRTF cryogenic system to satisfy a five-year mission lifetime requirement and maintain the SFHe tank operating temperature of 1.25 K to provide sufficient cooling for science instruments and the optical system. The thermal models are very detailed and very fast with a typical steady state run of about 20 sec on a VAX minicomputer.

Bhandari, Pradeep↗

Fabrication

What aspects of optical fabrication technology need to be developed so as to facilitate existing planned missions, or enable new ones? Throughout the submillimeter to UV wavelengths, the common goal is to push technology to the limits to make the largest possible apertures that are diffraction limited. At any one wavelength, the accuracy of the surface must be better than lambda/30 (rms error). The wavelength range is huge, covering four orders of magnitude from 1 mm to 100 nm. At the longer wavelengths, diffraction limited surfaces can be shaped with relatively crude techniques. The challenge in their fabrication is to make as large as possible a reflector, given the weight and volume constraints of the launch vehicle. The limited cargo diameter of the shuttle has led in the past to emphasis on deployable or erectable concepts such as the Large Deployable Reflector (LDR), which was studied by NASA for a submillimeter astrophysics mission. Replication techniques that can be used to produce light, low-cost reflecting panels are of great interest for this class of mission. At shorter wavelengths, in the optical and ultraviolet, optical fabrication will tax to the limit the most refined polishing methods. Methods of mechanical and thermal stabilization of the substrate will be severely stressed. In the thermal infrared, the need for large aperture is tempered by the even stronger need to control the telescope's thermal emission by cooled or cryogenic operation. Thus, the SIRTF mirror at 1 meter is not large and does not require unusually high accuracy, but the fabrication process must produce a mirror that is the right shape at a temperature of 4 K. Future large cooled mirrors will present more severe problems, especially if they must also be accurate enough to work at optical wavelengths. At the very shortest wavelengths accessible to reflecting optics, in the x-ray domain, the very low count fluxes of high energy photons place a premium on the collecting area. It is not necessary to reach or even approach the diffraction limit, which would demand subnanometer fabrication and figure control. Replication techniques that produce large very lightweight surfaces are of interest for x-ray optics just as they are for the submillimeter region. Optical fabrication requirements are examined in more detail for missions in each of the three spectral regions of interest in astrophysics.

Angel, Roger↗

Long-slit Spectra of the Red Rectangle at 3 Microns

We have observed the Red Rectangle with the Cryogenic Spectrometer (CRSP) at the 2.1 m telescope of Kitt Peak National Observatory. The Red Rectangle is a well-known source of the infrared emission features associated with polycyclic aromatic hydrocarbons (PAHs). Our long-slit spectra cover the 3.2-3.6 micrometer regime, which includes the strong PAH band at 3.29 micrometers, a weaker component at 3.40 micrometers, and an emission plateau which continues out to 3.6 micrometers. Emission in the PAH bands extends several arcseconds to the north and south of the central source (HD 44179). The seeing during our observations was approximately 1.5 arcseconds, but we have deconvolved the point spread function from our spectral images at each wavelength using maximum entropy reconstruction, allowing us to examine the relative behavior of these emission components at finer spatial scales. With the new 256x256 array installed on CRSP, each pixel covers 0.6 arcseconds of sky. Our reconstructions reveal that the strength of the small 3.4 micrometer emission feature increases with respect to the 3.3 micrometer feature as the distance from the central source increases. In particular, there appears to be a region of enhanced 3.4 micrometer emission roughly 3" to the north and south of the central source. We are analyzing our results in terms of the competing models for the origin of the 3.4 micrometer emission feature, which could be a vibrational overtone of the 3.3 micrometer feature, or could result from the attachment of molecular sidegroups to the PAH molecule.

Sloan, G. C.↗

Mirror Technology Roadmap for Optical/IR/FIR Space Telescopes

The Optics sub-committee of the Advanced Telescope and Observatory {ATO) Capability Roadmap developed an optics capability roadmap to enable planned future space telescopes. The roadmap details 4 basic technologies: cryogenic optics for IR and Far-IR missions; precision optics for optical, UV and EUV missions; grazing incidence optics for x-ray missions; and novel optics with revolutionary capabilities.

Stahl, H. Phil↗

Testing the James Webb Space Telescope Primary Mirror

JWST in-process optical testing and cryogenic requirement compliance certification, verification andvalidation was probably the most difficult metrology job of our generation in astronomical optics. But, the challenge was met: by hard work of dozens of optical metrologists; development and qualification of multiple custom test setups; and several new inventions, including 4D PhaseCam and Leica Absolute Distance Meter. This paper summarizes the metrology tools, test setups and processes used to characterize the JWST primary mirror.

Stahl, H. Philip↗

Electrical NEP in Hot-Electron Titanium Superconducting Bolometers

We are presenting the current progress on the titanium (Ti) hot-electron transition-edge devices. The ultimate goal of this work is to develop a submillimeter Hot-Electron Direct Detector (HEDD) with the noise equivalent power NEP = 10(sup -1) - 10(sup -20) W/Hz(sup 1/2) for the moderate resolution spectroscopy and Cosmic Microwave Background (CMB) studies on future space telescope (e.g., SPICA, SAFIR, SPECS, CMBPol) with cryogenically cooled (approximately 4-5 K) mirrors. Recently, we have achieved the extremely low thermal conductance (approximately 20 fW/K at 300 mK and approximately 0.1 fW/K at 40 mK) due to the electron-phonon decoupling in Ti nanodevices with niobium (Nb) Andreev contacts. This thermal conductance translates into the "phonon-noise" NEP approximately equal to 3 x 10(sup -21) W/Hz(sup 1/2) at 40 mK and NEP approximately equal to 3 x 10(sup -19) W/Hz(sup 1/2) at 300 mK. These record data indicate the great potential of the hot-electron detector for meeting many application needs. Beside the extremely low phonon-noise NEP, the nanobolometers have a very low electron heat capacitance that makes them promising as detectors of single THz photons. As the next step towards the practical demonstration of the HEDD, we fabricated and tested somewhat larger than in Ref.1 devices (approximately 6 micrometers x 0.35 micrometers x 40 nm) whose critical temperature is well reproduced in the range 300-350 mK. The output electrical noise measured in these devices with a low-noise dc SQUID is dominated by the thermal energy fluctuations (ETF) aka "phonon noise". This indicates the high electrothermal loop gain that effectively suppresses the contributions of the Johnson noise and the amplifier (SQUID) noise. The electrical NEP = 6.7 x 10(sup -18) W/Hz(sup 1/2) derived from these measurements is in good agreement with the predictions based on the thermal conductance data. The very low NEP and the high speed (approximately microns) are a unique combination not found in other detectors.

transition-edge sensor↗

Obtaining cryogenic molecular transport data for analysis

The James Webb Space Telescope (JWST) has a primary mirror, made of 18 segments, and a secondary mirror (SM) that are used to direct the light of desired targets. While on orbit, the secondary mirror assembly (SMA) was stowed for approximately 10 days and was subject to molecular contamination outgassing from the cavity of the secondary mirror support structure (SMSS) in-board hinge (IBH) which contains cables, motors, resolvers, and coatings. The main concern during this period before SMA deployment is the accumulation of ice due to the lack of a heater on the SMA. The temperature differentials between the IBH surfaces and SMA could cause redistribution of contaminants. To address this concern, single layer insulation (SLI) was used to create adequate venting and path redirection of outgassing from the IBH. Two separate thermal vacuum tests were performed to quantify this contamination: one Z307 ASTM E 1559 materials test of the radiator paint used on the motor of the IBH and a separate test on a primary mirror backplane assembly (PMBA) qualification engineering test unit (ETU) of the IBH. These tests approximately followed the predicted SMA pre-deployment thermal environment. To quantify source rates in case of a leak, the motor and resolver sides were separated and quartz crystal microbalances (QCM) were used to measure the deposition of water. The SLI redesign and implementation and outgassing measurements to understand leak effects from the IBH were essential to mitigate the deposition of contamination on the SMA.

James Webb Space Telescope, contamination, cleanro↗

Obtaining Cryogenic Molecular Transport Data for Analysis

The James Webb Space Telescope (JWST) has a primary mirror, made of 18 segments, and a secondary mirror (SM) that are used to direct the light of desired targets. While on orbit, the secondary mirror assembly (SMA) was stowed for approximately 10 days and was subject to molecular contamination outgassing from the cavity of the secondary mirror support structure (SMSS) in-board hinge (IBH) which contains cables, motors, resolvers, and coatings. The main concern during this period before SMA deployment is the accumulation of ice due to the lack of a heater on the SMA. The temperature differentials between the IBH surfaces and SMA could cause redistribution of contaminants. To address this concern, single layer insulation (SLI) was used to create adequate venting and path redirection of outgassing from the IBH. Two separate thermal vacuum tests were performed to quantify this contamination: one Z307 ASTM E 1559 materials test of the radiator paint used on the motor of the IBH and a separate test on a primary mirror backplane assembly (PMBA) qualification engineering test unit (ETU) of the IBH. These tests approximately followed the predicted SMA pre-deployment thermal environment. To quantify source rates in case of a leak, the motor and resolver sides were separated and quartz crystal microbalances (QCM) were used to measure the deposition of water. The SLI redesign and implementation and outgassing measurements to understand leak effects from the IBH were essential to mitigate the deposition of contamination on the SMA. "

James Webb Space Telescope↗

JWST Integrated Science Instrument Module Alignment Optimization Tool

During cryogenic vacuum testing of the James Webb Space Telescope (JWST) Integrated Science Instrument Module (ISIM), the global alignment of the ISIM with respect to the designed interface of the JWST optical telescope element (OTE) will be measured through a series of optical characterization tests. These tests will determine the locations and orientations of the JWST science instrument projected focal surfaces and entrance pupils with respect to their corresponding OTE optical interfaces. If any optical performance non-compliances are identified, the ISIM will be adjusted to improve its performance. In order to understand how to manipulate the ISIM's degrees of freedom properly and to prepare for the ISIM flight model testing, a series of optical-mechanical analyses have been completed to develop and identify the best approaches for bringing a non-compliant ISIM element into compliance. In order for JWST to meet its observatory-level optical requirements and ambitious science goals, the ISIM element has to meet approximately 150 separate optical requirements. Successfully achieving many of those optical requirements depends on the proper alignment of the ISIM element with respect to the OTE. To verify that the ISIM element will meet its optical requirements, a series of cryogenic vacuum tests will be conducted with an OTE Simulator (OSIM). An optical Ray Trace and Geometry Model tool was developed to help solve the multi-dimensional alignment problem. The tool allows the user to determine how best to adjust the alignment of the JWST ISIM with respect to the ideal telescope interfaces so that the approximately 150 ISIM optical performance requirements can be satisfied. This capability has not existed previously.

Bos, Brent↗

Development Tests of a Cryogenic Filter Wheel Assembly for the NIRCam Instrument

The James Webb Space Telescope is an infrared-optimized space telescope scheduled for launch in 201 3. Its 6.5-m diameter primary mirror will collect light from some of the first galaxies formed after the big bang. The Near Infrared camera (NIRCam) will detect the first light from these galaxies, provide the necessary tools for studying the formation of stars, aid in discovering planets around other stars, and adjust the wave front error on the primary mirror (Fig. 1). The instrument and its complement of mechanisms and optics will operate at a cryogenic temperature of 35 K. This paper describes tests and test results of the NIRCam Filter Wheel assembly prototype.

McCully, Sean↗

The flexure assembly design for the SIRTF one-meter primary mirror

A titanium flexure assembly for the Space Infrared Telescope Facility (SIRTF) 1-m primary mirror has been designed to accommodate: (1) the cryogenic cool-down effect on the optical performance of the mirror, (2) the Shuttle launch-load environment, and (3) the support-baseplate manufacturing tolerances. Numerous iterations involving a multidimensional design space search led to an assembly design that provides the stiffness and strength in the vertical (optical axis) and tangential directions to accommodate launch loads, but is compliant radially to accommodate cryogenic cool down. A 'folded back' titanium flexure system was required because of the differential thermal contraction of the aluminum telescope baseplate support and the fused-silica mirror. This unique and innovative flexure assembly represents a totally passive mechanism for accommodating the design launch loads, cryogenic cool down, and out-of-plane baseplate effects.

Richard, R. M.↗

The Optical Design of CHARIS: An Exoplanet IFS for the Subaru Telescope

High-contrast imaging techniques now make possible both imaging and spectroscopy of planets around nearby stars. We present the optical design for the Coronagraphic High Angular Resolution Imaging Spectrograph (CHARIS), a lenslet-based, cryogenic integral field spectrograph (IFS) for imaging exoplanets on the Subaru telescope. The IFS will provide spectral information for 138×138 spatial elements over a 2.07 arcsec × 2.07 arcsec field of view (FOV). CHARIS will operate in the near infrared (lambda = 1.15 − 2.5 micrometers) and will feature two spectral resolution modes of R is approximately 18 (low-res mode) and R is approximately 73 (high-res mode). Taking advantage of the Subaru telescope adaptive optics systems and coronagraphs (AO188 and SCExAO), CHARIS will provide sufficient contrast to obtain spectra of young self-luminous Jupiter-mass exoplanets. CHARIS will undergo CDR in October 2013 and is projected to have first light by the end of 2015. We report here on the current optical design of CHARIS and its unique innovations.

High Contrast Imaging↗

The Single Aperture Far-Infrared (SAFIR) Observatory and its Cryogenic Detector Needs

The development of a large, far-infrared telescope in space has taken on a new urgency with breakthroughs in detector technology and recognition of the fundamental importance of the far-infrared spectral region to questions ranging from cosmology to our own Solar System. The Single Aperture Far-InfraRed (SAFIR) Observatory is l0m-class far-infrared observatory that would begin development later in this decade to meet these needs. SAFIR's science goals are driven by the fact that youngest stages of almost all phenomena in the universe are shrouded in absorption by and emission from cool dust that emits strongly in the far-infrared, 20 microns - 1mm. Its operating temperature (4 K) and instrument complement would be optimized to reach the natural sky confusion limit in the far-infrared with diffraction-limited performance down to at least the atmospheric cutoff at 40 microns. This would provide a point source sensitivity improvement of several orders of magnitude over that of SIRTF. In order to achieve this, large arrays of detectors with NEPs ranging from a few to a hundred zeptowatts/sqrt(Hz) are needed. Very low temperature superconducting transition edge sensors and far-infrared "photon counting" detectors are critical technologies requiring development for the SAFIR mission.

Benford, Dominic J.↗

The NASA Space Infrared Telescope Facility

The NASA Space Infrared Observatory Facility (SIRTF) is a cryogenically cooled space observatory being developed for use in the early years of the next century. SIRTF will carry an 85 cm primary optic cooled to 5.5K and instrumentation covering the wavelength range from 3(micro)m to 180 (micro)m.

SIRTF space observatory↗

Cryogenic Thermal Distortion Performance Characterization for the JWST ISIM Structure

The James Webb Space Telescope (JWST) Integrated Science Instrument Module (ISIM) Structure is a precision optical metering structure for the JWST science instruments. Optomechanical performance requirements place stringent limits on the allowable thermal distortion of the metering structure between ambient and cryogenic operating temperature (~35 K). This paper focuses on thermal distortion testing and successful verification of performance requirements for the flight ISIM Structure. The ISIM Structure Cryoset Test was completed in Spring 2010 at NASA Goddard Space Flight Center in the Space Environment Simulator Chamber. During the test, the ISIM Structure was thermal cycled twice between ambient and cryogenic (~35 K) temperatures. Photogrammetry was used to measure the Structure in the ambient and cryogenic states for each cycle to assess both cooldown thermal distortion and repeatability. This paper will provide details on the post-processing of the metrology datasets completed to compare measurements with performance requirements.

Johnston, John D.↗

Conceptual Design of the Coronagraphic High Angular Resolution Imaging Spectrograph (CHARIS) for the Subaru Telescope

Recent developments in high-contrast imaging techniques now make possible both imaging and spectroscopy of planets around nearby stars. We present the conceptual design of the Coronagraphic High Angular Resolution Imaging Spectrograph (CHARIS), a lenslet-based, cryogenic integral field spectrograph (IFS) for imaging exoplanets on the Subaru telescope. The IFS will provide spectral information for 140 x 140 spatial elements over a 1.75 arcsecs x 1.75 arcsecs field of view (FOV). CHARIS will operate in the near infrared (lambda = 0.9 - 2.5 micron) and provide a spectral resolution of R = 14, 33, and 65 in three separate observing modes. Taking advantage of the adaptive optics systems and advanced coronagraphs (AO188 and SCExAO) on the Subaru telescope, CHARIS will provide sufficient contrast to obtain spectra of young self-luminous Jupiter-mass exoplanets. CHARIS is in the early design phases and is projected to have first light by the end of 2015. We report here on the current conceptual design of CHARIS and the design challenges.

Peters, Mary Anne↗

Space Infrared Telescope Facility (SIRTF) observatory design

The NASA Space IR Telescope Facility (SIRTF) is a 1-m aperture, cryogenically cooled IR observatory scheduled for launch into orbit in the mid-1990s. SIRTF will operate in the 2-700 micron range and yield a 1000-fold increase in sensitivity over NASA's IRAS observatory. A low inclination orbit compatible with Space Shuttle operations will be used. Results from comparisons of a system error budget allocation for the f/24 optical configuration with recent test data indicate that a figured fused silica mirror and a blade flexure mounting system can be cooled to cryogenic temperature while meeting required wavefront tolerances for substrate deformation. An all-He cooling system will be used in the low inclination orbit.