Search NASA⌕ Search

SEARCH · Search NASA

Results for “Curved detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

345 records · Page 20

A Study of the Radiation Tolerance of CVD Diamond to 70 MeV Protons, Fast Neutrons and 200 MeV Pions

We measured the radiation tolerance of commercially available diamonds grown by the Chemical Vapor Deposition process by measuring the charge created by a 120 GeV hadron beam in a 50 μm pitch strip detector fabricated on each diamond sample before and after irradiation. We irradiated one group of samples with 70 MeV protons, a second group of samples with fast reactor neutrons (defined as energy greater than 0.1 MeV), and a third group of samples with 200 MeV pions, in steps, to (8.8±0.9) × 1015 protons/cm2, (1.43±0.14) × 1016 neutrons/cm2, and (6.5±1.4) × 1014 pions/cm2, respectively. By observing the charge induced due to the separation of electron–hole pairs created by the passage of the hadron beam through each sample, on an event-by-event basis, as a function of irradiation fluence, we conclude all datasets can be described by a first-order damage equation and independently calculate the damage constant for 70 MeV protons, fast reactor neutrons, and 200 MeV pions. We find the damage constant for diamond irradiated with 70 MeV protons to be 1.62±0.07(stat)±0.16(syst)× 10−18 cm2/(p μm), the damage constant for diamond irradiated with fast reactor neutrons to be 2.65±0.13(stat)±0.18(syst)× 10−18 cm2/(n μm), and the damage constant for diamond irradiated with 200 MeV pions to be 2.0±0.2(stat)±0.5(syst)× 10−18 cm2/(π μm). The damage constants from this measurement were analyzed together with our previously published 24 GeV proton irradiation and 800 MeV proton irradiation damage constant data to derive the first comprehensive set of relative damage constants for Chemical Vapor Deposition diamond. We find 70 MeV protons are 2.60 ± 0.29 times more damaging than 24 GeV protons, fast reactor neutrons are 4.3 ± 0.4 times more damaging than 24 GeV protons, and 200 MeV pions are 3.2 ± 0.8 more damaging than 24 GeV protons. We also observe the measured data can be described by a universal damage curve for all proton, neutron, and pion irradiations we performed of Chemical Vapor Deposition diamond. Finally, we confirm the spatial uniformity of the collected charge increases with fluence for polycrystalline Chemical Vapor Deposition diamond, and this effect can also be described by a universal curve.

36 MATERIALS SCIENCE↗

A Study of the Non-Thermal X-ray Emission of Shell-Type Supernova Remnants

The term of the forth year of the award is the period from March 15, 2003 to March 14, 2004. During this year, Dr. Thomas Pannuti, who had been performing most of the analyses, made a transition to a new position at Caltech. As of September 2003, Dr. Michael Stage began performing most of the analyses. Dr. Stage has begun constructing a detailed catalog of the spatial and spectral properties of young supernova remnants as described in sections 1 and 4 of the proposal. Specifically, he has focused on the analysis of Chandra ACIS data. The exquisite spatial resolution of the Chandra telescope and the modest spectral resolution of the CCDs make these data ideal. Dr. Stage has developed a standard set of procedures to reduce the data, generate telescope and detector response libraries and handle instrumental and celestial background subtraction. He has also adapted some existing code to automate spectral extraction and fitting. This code enables us to analyze the spectra of tens of thousands of small subregions of supernova remnants. Dr. Stage has recently applied this process to ACIS data for the supernova remnants Cas A and Kepler. The results include maps of the fitted parameters, such as individual line intensities and centroids (i.e. Doppler shifts), the electron temperature, and the absorption column density. These maps are more accurate than simple energy-cut images because it is difficult (and sometimes impossible) to cleanly separate the line emission from the underlying continuum (especially at low energies). It is now possible to identify the locations at which emission from each element is produced. Some of the elements are seen to be layered. The electron temperature maps demonstrate that the outer edges of Cas A and Kepler are very hot with weak lines. This emission is almost certainly synchrotron dominated. Therefore, not only are the maps interesting in and of themselves, but they also provide an unbiased means of easily identifying features in the remnants that can be studied in more detail using, for example, synchrotron models. Over the next year, Dr. Stage will refine the analysis procedures, expand the analyses to include several other remnants, present the results at major scientific conferences and publish a catalog of the results. Since this work is producing impressive results, we have applied for very long Chandra observations of Kepler and Tycho to obtain enough counts to take lull advantage of the technique. A i Ms observation of Cas A is already scheduled. Over the past year, I completed a joint, spectra,l analysis of some X-ray, radio, and gamma-ray data for the supernova remnant SN 1006. The results of this analysis show that the synchrotron and, hence, electron spectrum of the remnant is curved. The amount of curvature in the electron spectrum is quantitatively consistent with predictions of the amount of curvature in the proton spectrum of the remnant. A paper describing this work is nearly complete. When Dr. Pannuti left, he was analyzing X-ray data for the young supernova remnant G266.2-1.2. Dr. Pannuti found the first evidence of thermal X-ray emission from this remnant. Furthermore, like SN 1006, the cutoff frequency varies with azimuth along the bright northeastern rim. This work will be published during the coming year.

Allen, Glenn E.↗

Infrared Camera System for Visualization of IR-Absorbing Gas Leaks

Leak detection and location remain a common problem in NASA and industry, where gas leaks can create hazardous conditions if not quickly detected and corrected. In order to help rectify this problem, this design equips an infrared (IR) camera with the means to make gas leaks of IR-absorbing gases more visible for leak detection and location. By comparing the output of two IR cameras (or two pictures from the same camera under essentially identical conditions and very closely spaced in time) on a pixel-by-pixel basis, one can cancel out all but the desired variations that correspond to the IR absorption of the gas of interest. This can be simply done by absorbing the IR lines that correspond to the gas of interest from the radiation received by one of the cameras by the intervention of a filter that removes the particular wavelength of interest from the "reference" picture. This can be done most sensitively with a gas filter (filled with the gas of interest) placed in front of the IR detector array, or (less sensitively) by use of a suitable line filter in the same location. This arrangement would then be balanced against the unfiltered "measurement" picture, which will have variations from IR absorption from the gas of interest. By suitable processing of the signals from each pixel in the two IR pictures, the user can display only the differences in the signals. Either a difference or a ratio output of the two signals is feasible. From a gas concentration viewpoint, the ratio could be processed to show the column depth of the gas leak. If a variation in the background IR light intensity is present in the field of view, then large changes in the difference signal will occur for the same gas column concentration between the background and the camera. By ratioing the outputs, the same signal ratio is obtained for both high- and low-background signals, even though the low-signal areas may have greater noise content due to their smaller signal strength. Thus, one embodiment would use a ratioed output signal to better represent the gas column concentration. An alternative approach uses a simpler multiplication of the filtered signal to make the filtered signal equal to the unfiltered signal at most locations, followed by a subtraction to remove all but the wavelength-specific absorption in the unfiltered sample. This signal processing can also reveal the net difference signal representing the leaking gas absorption, and allow rapid leak location, but signal intensity would not relate solely to gas absorption, as raw signal intensity would also affect the displayed signal. A second design choice is whether to use one camera with two images closely spaced in time, or two cameras with essentially the same view and time. The figure shows the two-camera version. This choice involves many tradeoffs that are not apparent until some detailed testing is done. In short, the tradeoffs involve the temporal changes in the field picture versus the pixel sensitivity curves and frame alignment differences with two cameras, and which system would lead to the smaller variations from the uncontrolled variables.

Youngquist, Robert↗