Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cyber security”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Smart Microgrids

The Nation’s electrical power depends on one bulk power grid to support security and economic prosperity. According to the Department of Homeland Security’s Homeland Threat Assessment of 2020, the largest cyber threat to homeland security is potential disruption to critical infrastructure, including power grids. Critical infrastructure includes the physical and cyber systems which generate, transmit, and distribute electricity with an impact on economic security, public health, or safety. The surety of the Nation’s power grid is vital for providing essential services and would put the population at risk if disrupted. Power outages can have catastrophic consequences for critical organizations such as hospitals and military installations. Additionally, the current fossil-fuel dependent power grid is extremely fragile and vulnerable to overloads, storms that destroy power lines, and cyber-attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Innovation in Radiological Security, Part 2 of 2 – Insights into Developing a Cloud-hosted Security Technology

A Sentry Remote Monitoring System (Sentry-RMS) is a stand-alone security system that provides detection, assessment, and communication of priority alarms as an additional means of thwarting internal and external threats to sites that maintain radiological material. The SEntry-RMS CommUnications and REsponse (Sentry-SECURE) platform is an optional feature of the Sentry-RMS that relays priority alarm information to the identified response stakeholders. Sentry-SECURE is hosted in a cloud environment that abstracts the data owner’s and data consumer’s platforms to allow for greater information sharing. This promotes situational awareness amongst authorized users and enables future innovation among modern response platforms. When securely architecting a cloud solution such as this, the use of design paradigms can be an effective tool to increase the accuracy and reliability of cyber- and information-security-related decisions made throughout the development process. This approach also supports the categorization of design considerations into three levels: industry concepts, project approaches, and data protections for digital processes. Industry concepts consist of the notional underpinnings that guide or motivate a security process, system, or design but often lack any tangible attributes. Project approaches represent decisions made during the design and development process to prioritize a solution, method, or practice above another that may provide a comparable functional output but lacks a desired security benefit. Data protections for digital processes represent the selection, integration, and implementation of specific controls for a given asset. This paper will explore specific examples of how Sentry-SECURE has been designed to account for considerations at each of these three levels, while balancing the operational intent of the platform with the security enhancements necessary to maintain data integrity, availability, and confidentiality.

assessment, RMS, security, physical, cloud, Cyber ↗

Modeling Data Flows with Network Calculus in Cyber-Physical Systems: Enabling Feature Analysis for Anomaly Detection Applications

The electric grid is becoming increasingly cyber-physical with the addition of smart technologies, new communication interfaces, and automated grid-support functions. Because of this, it is no longer sufficient to only study the physical system dynamics, but the cyber system must also be monitored as well to examine cyber-physical interactions and effects on the overall system. To address this gap for both operational and security needs, cyber-physical situational awareness is needed to monitor the system to detect any faults or malicious activity. Techniques and models to understand the physical system (the power system operation) exist, but methods to study the cyber system are needed, which can assist in understanding how the network traffic and changes to network conditions affect applications such as data analysis, intrusion detection systems (IDS), and anomaly detection. In this paper, we examine and develop models of data flows in communication networks of cyber-physical systems (CPSs) and explore how network calculus can be utilized to develop those models for CPSs, with a focus on anomaly and intrusion detection. This provides a foundation for methods to examine how changes to behavior in the CPS can be modeled and for investigating cyber effects in CPSs in anomaly detection applications.

97 MATHEMATICS AND COMPUTING↗

Cyber-Informed Engineering Overview: Joint NERC/INL/E-ISAC Webinar

In July, NERC, the Electricity Information Sharing and Analysis Center (E-ISAC), and Idaho National Laboratory (INL) will host a joint informational webinar to highlight areas focused on integrating cyber and physical security with conventional engineering practices (security integration). NERC's work on these topics represents one of the first focused applications of Cyber-Informed Engineering (CIE). INL is leading the development of philosophy and practices to identify and mitigate the inherent risks of digital technology by including cybersecurity as a core element of engineering risk management. This presentation will provide an overview of CIE, a discussion of how NERC's work represents one of the first new discipline-specific applications of CIE, and an update on significant milestones and resources from the CIE program.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Motivation and Design of the OCPP Security Service

Pacific Northwest National Laboratory is conducting in-depth research aimed at exploring how zero trust security principles can be effectively applied to electric vehicle charging infrastructure. This investigation seeks to enhance the resilience and reliability of these systems against cyber threats, ensuring secure and uninterrupted access to charging services for electric vehicle users and electric supply. Zero trust is a security concept centered on the belief that system operators should not automatically trust users or systems based on their location, whether inside or outside the organization, but instead must verify everything trying to connect to their systems before granting access. A key aspect of the project is to demonstrate and validate zero trust approaches targeted to electric vehicle (EV) charging infrastructure. It has been observed that both open-source and commercial solutions often overlook the specific protocols employed in managing EV charging stations and proceeded with a general, protocol-agnostic approach. While these strategies effectively block non-authorized routes to the charging infrastructure, they do not tackle the situations where attackers may exploit legitimate access channels, such as the inattentive operator model posited by the Idaho National Laboratory. To address this gap, this paper proposes and discusses a new security service targeted to the Open Charge Point Protocol (OCPP), which is the de facto protocol for the management of charging stations and serves a critical role in the broader adoption of electric vehicles. The design and architecture of the proposed OCPP security service are discussed in detail, outlining how it aims to safeguard charging station management system (CSMS) functions. The service is particularly important in scenarios where the charging station operator (CSO), responsible for the maintenance and operation of charging stations, and the charging network provider (CNP), which manages the charging network's accessibility and billing, are separate entities. This distinction is crucial because CSOs and CNPs often have different priorities, objectives, and operational responsibilities, which may not always align perfectly. For instance, a CSO might prioritize uptime and customer satisfaction, while a CNP might focus on maximizing revenue and network utilization. Such misalignment can create security vulnerabilities, as each entity might implement different policies and standards, potentially leaving gaps in the overall security posture.

33 ADVANCED PROPULSION SYSTEMS↗

Autonomous System Inference, Trojan, and Adversarial Reprogramming Attack and Defense (Final)

In the world of ever-advancing technology, Autonomous Systems (AS) find extensive application, bolstering functionalities of critical infrastructures such as nuclear power plants. These systems, however, are increasingly becoming a target for nefarious activities, namely through inference attacks, trojan attacks, and adversarial reprogramming. This paper delves into a comprehensive exploration of machine learning (ML)-driven autonomous control systems within advanced nuclear reactor designs, revealing the vulnerabilities and proposing strategies for defense against potential cyber-attacks. Advanced cyber-attacks against critical infrastructure and the energy sector are becoming more common. With the invention of autonomous control systems (ACS) within advanced nuclear reactor designs, system designers, reactor operators, and regulators must consider cybersecurity during the design and operational phases. This article provides a cyber threat assessment of machine learning (ML)- based digital twinning (DT) technologies in the context of advanced reactor ACS. A cyber-physical testbed was created to emulate nuclear reactor digital instrumentation and controls (I&C) and act as a basis for the ACS. The ACS was designed as two plant-level DTs predicting reactor malfunctions and determining control actions and two component-level DTs responsible for classifying component states and forecasting component inputs and outputs (I/O). Two duplicate ACS designs– one using a traditional ML framework and one using an automated ML (AutoML) framework– were created and tested against cyber-attacks on training data, real-time process data, and ML model architectures to determine their respective qualitative cyber-risk in terms of likelihood and impact. Both frameworks showed similar cyber-resilience against training, real-time, and ML architecture attacks, proving that neither is inherently more secure. Recommended safeguard and security measures are posed to system designers, reactor operators, and regulators to maintain the cybersecurity of ML-based DT technologies such as ACS, prompting a holistic view of shared responsibility for maintaining cyber-secure ML-based systems. As global reliance on generation III reactors begins to be critically assessed, the evolution towards advanced reactor systems utilizing digital instrumentation and controls (I&C) becomes not merely preferable, but essential. The integration of semi and fully autonomous control systems (ACS), powered by digital I&C and machine learning (ML)-based digital twinning (DT) technologies, emerges as a potent strategy to mitigate operations and maintenance costs, thereby enhancing the economic feasibility of novel reactor designs. However, with a staggering 500% and 380% increase in cyber-attacks reported against the energy sector by the United States Department of Energy (DoE) and the European Union respectively, a surge in cyber vulnerabilities specifically targeting the nuclear industry has been 2 markedly observed. Notable incidents, such as the W32.Ramnit spyware infiltration at the Gundremmingen nuclear power plant in Germany and the Dtrack spyware intrusion at the Kudankulam nuclear power plant in India, while not directly compromising core industrial control systems (ICS), underscore a compelling necessity to fortify cybersecurity protocols in safeguarding reactor systems against increasingly adept digital adversaries. In light of this, our investigation extends beyond conventional cybersecurity parameters, diving into the intricate web of potential vulnerabilities woven into ML-based DTs and ACS in advanced reactor systems. A crafted cyber-physical testbed and preliminary ACS were devised to act as a mirror, reflecting potential configurations of advanced reactor control designs. Moreover, this study is intertwined with a scrutinization of ML models, developed either through conventional, manually tuned methodologies or via automated means through AutoML, probing into their cyber-risk profiles within operational technology (OT) environments. Expanding on this, two distinct ACS blueprints were forged – one navigating through the corridors of traditional ML and the other traversing the path of AutoML – in an effort to holistically encapsulate the considerations pivotal to ML-based DT control system design. Employing the SANS Institute Industrial Control System (ICS) Kill Chain and the MITRE ATT&CK Tactics, Techniques, and Procedures (TTP) framework, a structured analysis was conducted, launching three targeted attacks against the training dataset, real-time dataset, and ML models, therein dissecting the potential cyber-attack implications against both ML frameworks within an ACS milieu. It is essential to note that three distinct categories of attacks were conducted against both ACS configurations, each encompassing three distinct ML-based DTs, cumulating in a total of 18 varied attacks. This exploration extends into the realms of Autonomous System Inference, Trojan, and Adversarial Reprogramming Attack and Defense, unraveling vulnerabilities, and opportunities for fortified defenses against such intrusions, particularly where ML-driven technologies, and by extension, ACS, are deployed. Final recommendations, articulated through a lens of security, safeguard, and implementation considerations, are presented for both traditional and AutoML models, anchoring upon the existing knowledge landscape and ML-based DT modeling for ACS, and are offered as a beacon to guide the nuclear industry through the intricate cybersecurity challenges that lie ahead.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Robust Method to Secure Multi-Inverter Grid Tied PV and Battery Energy Storage Systems Against Cyber Intrusions

This paper details a robust method to secure a multi-inverter grid tied system that interfaces photovoltaic (PV) and battery energy storage against potential cyber-attacks. The method can be applied to any third-party inverter systems without a need to modify their internal controls. A small random private excitation signal termed "watermark" is injected into the DC input voltage terminals (via a series transformer) connected to the PV/battery inverter system. An external robust cyber intrusion detector (CID) hardware consisting of a digital signal processor (DSP) generates the "watermark" and also receives the sensor signals that control the setpoints of the PV/battery grid tied system. The CID algorithm is shown to detect all possible cyber intrusions (such as false data injection(FDI)) on external sensor signals such as P and Q measured by a smart meter that control the overall system operation. The proposed CID computes online system ID and two variance tests in real time on each sensor signal and is able pinpoint intrusion location in a multi-inverter system. Results on a hardware in the loop (HIL) of a two-inverter grid connected system demonstrate effectiveness of the proposed CID system for FDI and unobservable FDI. Test results on a laboratory prototype will be discussed in the conference presentation.

Ibrahim, Hasan↗

ROTOR: Research to Operations and Operations to Research

PNNL’s Research to Operations/Operations to Research (ROTOR) Program fosters a cybersecurity operations to researcher collaboration, identifying hard problems and challenges for cyber defenders and bringing researcher science disciplines to these challenges. ROTOR allows PNNL’s cyber defenders to better protect the laboratory but also fosters innovation and incubation of solutions for our sponsor missions across DOE, DOD, DHS and the intelligence community. Our sponsors and their missions are faced with many of the same cyber defense challenges that PNNL faces. By using our own laboratory security operations environment as an innovation generator and testing ground, allowing research to be tested and tried, our sponsors are directly benefitted. PNNL is in a unique position to combine our world class research organization with enterprise cybersecurity operations. ROTOR is taking advantage of this to bring PNNL cybersecurity research projects into an operational environment within PNNL’s Cyber Security Operations Center. With ROTOR, PNNL researchers gain the advantage of operational experience and expertise and have an avenue for showcasing research in an operational environment. This helps to advance PNNL research, prove operability of PNNL projects to its sponsors, and provide real-world insight to real-world problems for our cybersecurity research agenda. ROTOR is the conduit for PNNL cybersecurity research to find its way to operational use. PNNL researchers and engineers are informed by real-world operations and operations has access to current PNNL research and engineering capabilities. All of this leads to improved reputation for PNNL as a provider of national security solutions that are tried and tested. To date, ROTOR has collaborated with six projects, enabling each to conduct operational work within the CSOC.

97 MATHEMATICS AND COMPUTING↗

Capabilities for Water Sector Infrastructure Resilience - Prioritizing RD&D in a Target Rich, Resource Poor Sector

WSTB & Water Sector Security Program Expansion Objective: Incubate and shepherd a public-private consortium of joint seal US government sponsors and industry stakeholders to build out industrial control system (ICS) and operational technology (OT) architecture of the Idaho National Laboratory (INL) Water Security Test Bed (WSTB) asset to enable research, testing, and cyber workforce training related to evolving cyber-physical and physical vulnerabilities and threats in the water sector.

99 - GENERAL AND MISCELLANEOUS↗

A Privacy-Preserving Cyber Threat Intelligence Sharing System

Cyber Threat Intelligence (CTI) is a key resource for developing defensive strategies against potential cyber adversaries. Entities typically access CTI through open-source platforms, national agencies, or specialized commercial services. However, the bi-directional exchange of CTI is hindered by organizational trust boundaries, which complicate the sharing processes between entities and CTI providers. Centralized CTI services benefit from receiving suspicious cyber observables such as IP addresses, domain names, and email addresses from various entities. The aggregation allows for the correlation of widespread adversarial activities to enhance the alert and response mechanisms across the network of involved parties. Despite these benefits, openly sharing such observables incurs potential legal, regulatory, and reputational risks for the disclosing entities.This paper introduces a system designed to facilitate the secure exchange of cyber observables across trust boundaries without compromising the anonymity of the sharing entities. Here, we propose an architecture that leverages common web protocols alongside zero-knowledge proofs to authenticate members while maintaining anonymity. Additionally, we outline a privacy model tailored for STIX (Structured Threat Information eXpression) cyber observables to minimize the risk of inadvertently disclosing private information. Through our threat models, we assess the privacy implications of our proposed system and demonstrate its potential to enhance collaborative cyber defense efforts without exposing entities to undue risk.

BBS+ Signatures↗

Prioritizing ICS Beachhead Systems for Cyber Vulnerability Testing

Cyber Testing for Resilient Industrial Control Systems™ (CyTRICS™) is the Department of Energy’s (DOE’s) program for cybersecurity vulnerability testing, digital subcomponent enumeration, and forensic assessment. CyTRICS leverages best-in-class test facilities and analytic capabilities at six DOE National Laboratories and strategic partnerships with key stakeholders including technology developers, manufacturers, asset owners and operators, and interagency partners. During the program’s development, CyTRICS established a unique methodology for prioritizing digital components within operational technology (OT) and industrial control systems (ICS) in the Energy Sector Industrial Base (ESIB) for cyber vulnerability testing. The CyTRICS Prioritization Process leverages multiple characteristics of systems, components, and their contextual deployment to calculate a quantification of individual digital components for CyTRICS testing. The initial version of the CyTRICS Prioritization Process was premised largely upon the impact which could result to an industrial control system if the digital component under testing was compromised, either through malicious means, faulty engineering, or other modes. The worldwide compromise of the SolarWinds Orion platform, first reported in December 2020, through malicious interference with the digital patching cycle was a watershed event in cyber supply chain security. The SolarWinds compromised demonstrated the strategic importance of certain types of ubiquitous software, and the ability to generate widespread cybersecurity effects. To address this challenge and as a part of the Department of Energy’s response to the SolarWinds compromise, DOE’s Office of Cybersecurity, Energy Security, and Emergency Response (CESER) directed the National Laboratories to evolve the CyTRICS Prioritization Process methodology to encompass additional factors related to the strategic importance of digital components. CESER directed CyTRICS researchers to identify, characterize, and append strategic factors to the CyTRICS Prioritization Process to provide additional weight to these characteristics. National Laboratory expert researchers identified functionality, distribution, and platform characteristics for digital components in ICS and OT that they assessed would be likely targeted in strategic initial-access cyber attack. CyTRICS has termed these factors “ICS Beachhead Systems,” leveraging a definition first advanced by Schneider Electric, which is intended as a blanket term to encompass digital components, products, and systems in OT. This paper describes the ICS Beachhead Systems identified and the rationale for inclusion. As a next step in the research and refinement process, the National Laboratories will validate this initial set of characteristics against digital components evaluated by the CyTRICS program and current implementation of the CyTRICS Prioritization Process. After validation, CyTRICS researchers will then develop a scoring methodology to generate a quantitative score to assess the degree to which a digital component is characterized as an ICS Beachhead System. Finally, the National Laboratories will append this scoring to the existing CyTRICS Prioritization Process algorithm.

97 MATHEMATICS AND COMPUTING↗

Advanced Transmission Technologies (ATTs) Supplier Cohort Workshops Cohort Summary [Slides]

This Summary slide deck summarizes the key outcomes of the Advanced Transmission Technologies (ATTs) supplier cohort, part of Idaho National Laboratory’s (INL) Technical Assistance for Digital Assurance (TADA) program. The program aimed to strengthen grid resilience through cybersecurity controls, supply-chain security, and Cyber-Informed Engineering (CIE) for advanced transmission technologies. The cohort brought together vendors representing the full range of Grid-Enhancing Technologies (GETs), including providers of Dynamic Line Ratings (DLR), Advanced Power Flow Control (APFC), Transmission Topology Optimization (TTO), and High-Performance Conductors (HPCs). Discussions focused on institutional, integration, and operational barriers limiting GET adoption; cybersecurity risks at EMS/SCADA, cloud, and network integration points; and supply-chain transparency issues such as semiconductor dependence and SBOM/HBOM expectations. Participants also addressed operator trust, human-in-the-loop requirements, and challenges with utility adoption, while exploring how CIE can support secure deployment of GETs. This deck represents a consolidated summary of challenges and risks identified by vendors, cross-cutting themes and technology-specific insights from three cohort workshops, and actionable mitigations to guide utilities, vendors, and the Department of Energy in advancing secure, trusted deployment of GETs.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

NASA IV&V's Cyber Range for Space Systems

A cyber range is a virtual environment that is used for cyberwarfare training and cyber technology development. It provides tools that help strengthen the stability, security and performance of cyber infrastructures and IT systems. NASA IV&V has created an adaptable virtual environment that is representative of a typical NASA mission system of systems environment that serves multiple purposes: Training of network defenders. Ability to perform simulated red vs blue training events. Ability to deploy mission specific technologies in a cyber contested environment. Ability to demonstrate vulnerabilities and their impact to ground and space systemsThe overall system is comprised of more than 70 virtual machines and physical infrastructure to demonstrate real-world cyber attacks against: email users, wireless networks, and physically implanted devices with command and control call-back. The cyber range was built to emulate a NASA precipitation satellite infrastructure.This presentation will give an overview of the virtual cyber range and how it was used to conduct a simulate red vs blue exercise with the goal of compromising the simulated spacecraft that utilizes real NASA flight software.

test and evaluation DT&E↗

Cyber threat assessment of machine learning driven autonomous control systems of nuclear power plants

We report advanced cyber-attacks against critical infrastructure and the energy sector are becoming more common. With the invention of autonomous control systems (ACS) within advanced nuclear reactor designs, system designers, reactor operators, and regulators must consider cybersecurity during the design and operational phases. This article provides a cyber threat assessment of machine learning (ML)-based digital twinning (DT) technologies in the context of advanced reactor ACS. A cyber–physical testbed was created to emulate nuclear reactor digital instrumentation and controls (I&C) and act as a basis for the ACS. The ACS was designed as two plant-level DTs predicting reactor malfunctions and determining control actions and two component-level DTs responsible for classifying component states and forecasting component inputs and outputs (I/O). Two duplicate ACS designs– one using a traditional ML framework and one using an automated ML (AutoML) framework– were created and tested against cyber-attacks on training data, real-time process data, and ML model architectures to determine their respective qualitative cyber-risk in terms of likelihood and impact. Both frameworks showed similar cyber-resilience against training, real-time, and ML architecture attacks, proving that neither is inherently more secure. Recommended safeguard and security measures are posed to system designers, reactor operators, and regulators to maintain the cybersecurity of ML-based DT technologies such as ACS, prompting a holistic view of shared responsibility for maintaining cyber-secure ML-based systems.

99 GENERAL AND MISCELLANEOUS↗

Efficient Clustering of Software Vulnerabilities using Self Organizing Map (SOM)

The common vulnerabilities and exposures (CVE) database was created with a mission to ``identify, define, and catalog publicly disclosed cybersecurity vulnerabilities''. This rich body of information can be used to enable rapid and efficient response to secure and defend cyber operations and protect critical cyber infrastructure. The main goal of this paper is to develop a visual analytics tool to enable deep analysis of CVEs using unsupervised clustering techniques. We enhance our analysis by first mapping CVEs to hierarchical-classes in Common Weakness Enumeration (CWE) using information in the National Vulnerability Database (NVD). Both the mapping and the numerical representation of CVEs are enabled by V2W-BERT, which uses natural language processing of the extensive information in NVD to generate a large tabular database of 137,226 CVE entries from 1999 to 2020, where each CVE is represented by a vector of 768 numerical features. The vectorized data is processed by Self-Organizing Maps (SOM), which is an unsupervised machine learning technique for dimensionality reduction, visual representation and clustering. Using a Torus map of 6417 units, we achieve ~10-fold data compression of ~140k CVEs using SOM. The trained map is further clustered using standard K-means clustering into 138 clusters of CVEs. We conducted a brief investigation of the rich mapping of CVEs to best-matching-units to K-means clusters, as well as CVEs to CWEs. For example, this novel mapping provided insight into the role of CWE-59 and CWE-264 in several CVEs that is otherwise hard to explore in the original data. We conclude that our this novel approach will not only enable deep analysis of the complex relationships between CVEs and CWEs, but also a mechanism to quickly respond to and design mitigation actions for rapidly evolving vulnerabilities that have not been mapped to existing CWEs.

Panchal, Khyati↗

Employee Spotlight: Christopher Graham

Christopher Graham of Special Security IT and Cyber Operations (SSO-3) makes medieval armor using a combination of old-school techniques and tools with modern accouterments, such as a blacksmith’s gas-powered forge and a power hammer.

99 GENERAL AND MISCELLANEOUS↗

Energy Sector Threat Brief: Trends and Incidents

This is a threat brief of cyber incidents and trends affecting the global energy sector over the last 12 months and resources for threat sharing, targeting an audience of utility cyber and physical security stakeholders.

24 - POWER TRANSMISSION AND DISTRIBUTION↗