Search NASA⌕ Search

SEARCH · Search NASA

Results for “DATA READOUT SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Method for Continuous Monitoring of Electrospray Ion Formation

A method for continuously monitoring the performance of electrospray ionization without the addition of hardware or chemistry to the system is demonstrated. In the method, which we refer to as SprayDx, cluster ions with solvent vapor natively formed by electrospray are followed throughout the collection of liquid chromatography–selected reaction monitoring data. The cluster ion extracted ion chromatograms report on the consistency of the ion formation and detection system. The data collected by the SprayDx method resemble the data collected for postcolumn infusion of analyte. The response of the cluster ions monitored reports on changes in the physical parameters of the ion source such as voltage and gas flow. SprayDx is also observed to report on ion suppression in a fashion very similar to a postcolumn infusion of analyte. We anticipate the method finding utility as a continuous readout on the performance of electrospray and other atmospheric pressure ionization processes. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-cell proteomics of Arabidopsis leaf mesophyll reveals dynamic protein responses to water-deficit stress

Background The application of single-cell omics tools to biological systems can provide unique insights into diverse cellular populations and their heterogeneous responses to internal and external perturbations. Thus far, most single-cell studies in plant systems have been limited to RNA-sequencing approaches, which only provide indirect readouts of cellular functions. Results Here, we present a single-cell proteomics workflow for plant cells that integrates tape-sandwich protoplasting, piezoelectric cell sorting, nanoPOTS sample preparation, and ion mobility-based MS data acquisition method for label-free single-cell proteomics analysis of Arabidopsis leaf mesophyll cells. From a single leaf protoplast, over 3,000 proteins were quantified with high precision. The workflow is demonstrated to identify stress associated changes in protein abundance by analyzing 117 protoplasts from well-watered and water-deficit stressed plants. Additionally, we describe a new approach for constructing covarying protein networks at the single-cell level and demonstrate how single-cell protein covariation analysis can reveal previously unrecognized protein functions while also capturing stress-induced changes in protein–protein dynamics. Conclusions The label-free scProteomic approach presented here represents a significant advance through the demonstration of a facile protoplast isolation method combined with deep and precise proteomic coverage of Arabidopsis leaf mesophyll cell types. We believe this study will serve as an informative reference to future plant scProteomic investigations.

Arabidopsis↗

Study of spacecraft direct readout meteorological systems

Characteristics are defined of the next generation direct readout meteorological satellite system with particular application to Tiros N. Both space and ground systems are included. The recommended space system is composed of four geosynchronous satellites and two low altitude satellites in sun-synchronous orbit. The goesynchronous satellites transmit to direct readout ground stations via a shared S-band link, relayed FOFAX satellite cloud cover pictures (visible and infrared) and weather charts (WEFAX). Basic sensor data is transmitted to regional Data Utilization Stations via the same S-band link. Basic sensor data consists of 0.5 n.m. sub-point resolution data in the 0.55 - 0.7 micron spectral region, and 4.0 n.m. resolution data in the 10.5 - 12.6 micron spectral region. The two low altitude satellites in sun-synchronous orbit provide data to direct readout ground stations via a 137 MHz link, a 400 Mhz link, and an S-band link.

Bartlett, R.↗

Analysis of TIMS performance subjected to simulated wind blast

The results of the performance of the Thermal Infrared Multispectral Scanner (TIMS) when it is subjected to various wind conditions in the laboratory are described. Various wind conditions were simulated using a 24 inch fan or combinations of air jet streams blowing toward either or both of the blackbody surfaces. The fan was used to simulate a large volume of air flow at moderate speeds (up to 30 mph). The small diameter air jets were used to probe TIMS system response in reaction to localized wind perturbations. The maximum nozzle speed of the air jet was 60 mph. A range of wind directions and speeds were set up in the laboratory during the test. The majority of the wind tests were conducted under ambient conditions with the room temperature fluctuating no more than 2 C. The temperature of the high speed air jet was determined to be within 1 C of the room temperature. TIMS response was recorded on analog tape. Additional thermistor readouts of the blackbody temperatures and thermocouple readout of the ambient temperature were recorded manually to be compared with the housekeeping data recorded on the tape. Additional tests were conducted under conditions of elevated and cooled room temperatures. The room temperature was varied between 19.5 to 25.5 C in these tests. The calibration parameters needed for quantitative analysis of TIMS data were first plotted on a scanline-by-scanline basis. These parameters are the low and high blackbody temperature readings as recorded by the TIMS and their corresponding digitized count values. Using these values, the system transfer equations were calculated. This equation allows us to compute the flux for any video count by computing the slope and intercept of the straight line that relates the flux to the digital count. The actual video of the target (the lab floor in this case) was then compared with a simulated target. This simulated target was assumed to be a blackbody at emissivity of .95 degrees and the temperature was assumed to be at ambient temperature as recorded by the TIMS for each scanline. Using the slope and the intercept the flux corresponding to this target was converted into digital counts. The counts were observed to have a strong correlation with the actual video as recorded by the TIMS. The attached graphs describe the performance of the TIMS when compressed air is blown at each one of the blackbodies at different speeds. The effect of blowing a fan and changing the room temperature is also being analyzed. Results indicate that the TIMS system responds to variation in wind speed in real time and maintains the capability to produce accurate temperatures on a scan line basis.

Jaggi, S.↗

A faster and more reliable data acquisition system for the full performance of the SciCRT

The SciBar Cosmic Ray Telescope (SciCRT) is a massive scintillator tracker to observe cosmic rays at a very high-altitude environment in Mexico. The fully active tracker is based on the Scintillator Bar (SciBar) detector developed as a near detector for the KEK-to-Kamioka long-baseline neutrino oscillation experiment (K2K) in Japan. Since the data acquisition (DAQ) system was developed for the accelerator experiment, we determined to develop a new robust DAQ system to optimize it to our cosmic-ray experiment needs at the top of Mt. Sierra Negra (4600 m). One of our special requirements is to achieve a 10 times faster readout rate. We started to develop a new fast readout back-end board (BEB) based on 100 Mbps SiTCP, a hardware network processor developed for DAQ systems for high energy physics experiments. Then we developed the new BEB which has a potential of 20 times faster than the current one in the case of observing neutrons. Lastly, we installed the new DAQ system including the new BEBs to a part of the SciCRT in July 2015. The system has been operating since then. In this article, we describe the development, the basic performance of the new BEB, the status after the installation in the SciCRT, and the future performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dosimetric evaluation of a novel polymer gel dosimeter for proton therapy

Purpose: The aim of this study is to evaluate the dosimetric performance of a newly developed proton-sensitive polymer gel formulation for proton therapy dosimetry. Methods: Using passive scattered modulated and nonmodulated proton beams, the dose response of the gel was assessed. A next-generation optical CT scanner is used as the readout mechanism of the radiation-induced absorbance in the gel medium. Comparison of relative dose profiles in the gel to ion chamber profiles in water is performed. A simple and easily reproducible calibration protocol is established for routine gel batch calibrations. Relative stopping power ratio measurement of the gel medium was performed to ensure accurate water-equivalent depth dose scaling. Measured dose distributions in the gel were compared to treatment planning system for benchmark irradiations and quality of agreement is assessed using clinically relevant gamma index criteria. Results: The dosimetric response of the gel was mapped up to 600 cGy using an electron-based calibration technique. Excellent dosimetric agreement is observed between ion chamber data and gel. The most notable result of this work is the fact that this gel has no observed dose quenching in the Bragg peak region. Quantitative dose distribution comparisons to treatment planning system calculations show that most (>97%) of the gel dose maps pass the 3%/3 mm gamma criterion. Conclusions: This study shows that the new proton-sensitive gel dosimeter is capable of reproducing ion chamber dose data for modulated and nonmodulated Bragg peak beams with different clinical beam energies. The findings suggest that the gel dosimeter can be used as QA tool for millimeter range verification of proton beam deliveries in the dosimeter medium.

61 RADIATION PROTECTION AND DOSIMETRY↗

A SEARCH FOR OCCULTATIONS OF BRIGHT STARS BY SMALL KUIPER BELT OBJECTS USING MEGACAM ON THE MMT

We conducted a search for occultations of bright stars by Kuiper Belt Objects (KBOs) to estimate the density of subkilometer KBOs in the sky. We report here the first results of this occultation survey of the outer solar system conducted in 2007 June and 2008 June/July at the MMT Observatory using Megacam, the large MMT optical imager. We used Megacam in a novel shutterless continuous-readout mode to achieve high-precision photometry at 200 Hz, which with point-spread function convolution results in an effective sampling of {approx}30 Hz. We present an analysis of 220 star hours of data at a signal-to-noise ratio of 25 or greater, taken from images of fields within 3 deg. of the ecliptic plane. The survey efficiency is greater than 10% for occultations by KBOs of diameter d {>=} 0.7 km, and we report no detections in our data set. We set a new 95% confidence level upper limit for the surface density {sigma} {sub N}(d) of KBOs larger than 1 km: {sigma} {sub N}(d {>=} 1 km) {<=} 2.0 x 10{sup 8} deg{sup -2}, and for KBOs larger than 0.7 km {sigma} {sub N}(d {>=} 0.7 km) {<=} 4.8 x 10{sup 8} deg{sup -2}.

79 ASTRONOMY AND ASTROPHYSICS↗

A forward bias method for lag correction of an a-Si flat panel detector

Purpose: Digital a-Si flat panel (FP) x-ray detectors can exhibit detector lag, or residual signal, of several percent that can cause ghosting in projection images or severe shading artifacts, known as the radar artifact, in cone-beam computed tomography (CBCT) reconstructions. A major contributor to detector lag is believed to be defect states, or traps, in the a-Si layer of the FP. Software methods to characterize and correct for the detector lag exist, but they may make assumptions such as system linearity and time invariance, which may not be true. The purpose of this work is to investigate a new hardware based method to reduce lag in an a-Si FP and to evaluate its effectiveness at removing shading artifacts in CBCT reconstructions. The feasibility of a novel, partially hardware based solution is also examined. Methods: The proposed hardware solution for lag reduction requires only a minor change to the FP. For pulsed irradiation, the proposed method inserts a new operation step between the readout and data collection stages. During this new stage the photodiode is operated in a forward bias mode, which fills the defect states with charge. A Varian 4030CB panel was modified to allow for operation in the forward bias mode. The contrast of residual lag ghosts was measured for lag frames 2 and 100 after irradiation ceased for standard and forward bias modes. Detector step response, lag, SNR, modulation transfer function (MTF), and detective quantum efficiency (DQE) measurements were made with standard and forward bias firmware. CBCT data of pelvic and head phantoms were also collected. Results: Overall, the 2nd and 100th detector lag frame residual signals were reduced 70%-88% using the new method. SNR, MTF, and DQE measurements show a small decrease in collected signal and a small increase in noise. The forward bias hardware successfully reduced the radar artifact in the CBCT reconstruction of the pelvic and head phantoms by 48%-81%. Conclusions: Overall, the forward bias method has been found to greatly reduce detector lag ghosts in projection data and the radar artifact in CBCT reconstructions. The method is limited to improvements of the a-Si photodiode response only. A future hybrid mode may overcome any limitations of this method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Nimbus 4 IRLS meteorological experiment

The Nimbus 4 interrogation, recording, and location system is designed to locate and collect measurement data of upper atmospheric parameters through the tracking of free floating, constant level balloons flying at altitudes of 20.5 and 24.1 km and carrying specially designed interrogation packages. The basic elements of the system include a ground acquisition and command station, the Nimbus satellite, and the remote sensing platforms. Addresses of platforms as they come into view are programmed into the satellite on an orbit by orbit basis from the central ground station. Sensory data are transmitted to the satellite for storage and readout from balloon interrogation units.

Cote, C. E.↗

TTDAQ: A Continuous Flow, Timing and Trigger DAQ System

Final Scientific/Technical Report for DOE Award DE-SC0019581, “TTDAQ: A Continuous Flow, Timing and Trigger DAQ System.” The report summarizes Telluric Labs’ Phase II STTR work developing silicon-photonic building blocks for a software-defined, continuous-flow, trigger-less data acquisition system for next-generation high-energy and nuclear-physics detectors. The project focused on radiation-hard photonic integrated circuits, remote optical illumination, dense wavelength-division multiplexing, and a differential microring-resonator transceiver architecture designed to improve high-speed optical link stability and bandwidth. The report describes project objectives, technical accomplishments, AIM Photonics tape-outs, bench characterization, radiation-hardness testing, deferred integration work, and potential applications beyond physics readout.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical readout of singlet fission biexcitons in a heteroacene with photoluminescence detected magnetic resonance

Molecular spin systems based on photoexcited triplet pairs formed via singlet fission (SF) are attractive as carriers of quantum information because of their potentially pure and controllable spin polarization, but developing systems that offer optical routes to readout as well as initialization is challenging. Herein, we characterize the electron spin magnetic resonance change in the photoluminescence intensity for a tailored organic molecular crystal while sweeping a microwave drive up to 10 GHz in a broadband loop structure. We observe resonant transitions for both triplet and quintet spin sublevel populations showing their optical sensitivity and revealing the zero-field parameters for each. We map the evolution of these spectra in both microwave frequency and magnetic field, producing a pattern of optically detected magnetic resonance (ODMR) peaks. Fits to these data using a suitable model suggest significant spin polarization in this system with orientation selectivity. Unusual excitation intensity dependence is also observed, which inverts the sign of the ODMR signal for the triplet features, but not for the quintet. These observations demonstrate optical detection of the spin sublevel population dictated by SF and intermolecular geometry, and highlight anisotropic and multi-scale dynamics of triplet pairs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reconstruction and Selection Tools for Charged-Current Muon Neutrino Cross Sections in SBND

SBND Near detector for the Short-Baseline Neutrino program [1] searching for sterile neutrinos in the Booster Neutrino Beam. Data taking starts in 2020. Primary detector is a liquid argon time projection chamber with a central cathode and two drift regions (TPCs). Ionization caused by charged particles is drifted in a strong electric field and detected on wire planes. Readout triggered by the neutrino beam timing and the photon detector system (PDS). Equipped with a suite of cosmic ray taggers (CRTs) [2] surrounding the central detector. Cross-sections and backgrounds SBND will provide world leading neutrino-argon cross-sections with 7,000,000 neutrino events in three years. Charged-current muon neutrino interactions will be the most abundant. The detector is on the surface with a small overburden so there is a high flux of cosmic rays (mostly muons). Cosmic ray muons can be significant background because the electron drift velocity is slow. Reconstruction Charged deposited in the TPC is reconstructed into track and shower objects with calorimetry and interaction topology information [3]. Unambiguous cosmic rays are removed. Particle-CRT intersections are reconstructed as CRT hits, trajectories of through-going particles are reconstructed as CRT tracks. Cosmic background removal SBND will see 2-3 cosmic muon interactions in the TPC for every neutrino interaction after reconstruction and initial cosmic rejection. A number of selection cuts utilizing TPC, CRT and PDS information have been developed to further reduce this background. Particles in the detector before or after the trigger time will have a shifted reconstructed X-position, most rejection methods involve finding the true crossing time (t0).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SQuaD: Smart Quantum Detection for Photon Recognition and Dark Count Elimination

Quantum detectors of single photons are an essential component for quantum information processing across computing, communication and networking. Today's quantum detection system, which consists of single photon detectors, timing electronics, control and data processing software, is primarily used for counting the number of single photon detection events. However, it is largely incapable of extracting other rich physical characteristics of the detected photons, such as their wavelengths, polarization states, photon numbers, or temporal waveforms. This work, for the first time, demonstrates a smart quantum detection system, SQuaD, which integrates a field programmable gate array (FPGA) with a neural network model, and is designed to recognize the features of photons and to eliminate detector dark-count. The SQuaD is a fully integrated quantum system with high timing-resolution data acquisition, onboard multi-scale data analysis, intelligent feature recognition and extraction, and feedback-driven system control. Our \name experimentally demonstrates 1) reliable photon counting on par with the state-of-the art commercial systems; 2) high-throughput data processing for each individual detection events; 3) efficient dark count recognition and elimination; 4) up to 100% accurate feature recognition of photon wavelength and polarization. Additionally, we deploy the SQuaD to an atomic (erbium ion) photon emitter source to realize noise-free control and readout of a spin qubit in the telecom band, enabling critical advances in quantum networks and distributed quantum information processing.

Linne, Karl C. [U. Chicago (main)] (ORCID:00090009↗

Development of a New Photo-detector Readout Technique for PET and CT

In the framework of the European FP6's BioCare project, we develop a novel photo-detector readout technique to increase sensitivity and timing precision for molecular imaging in PET and CT. Within the Project's work packages, the CERN-BioCare group focuses on the development of a PET detection head suitable to process data from both PET and CT operation in one unit. The detector module consists of a LSO matrix coupled to an APD array. The signal is processed by fast and low noise readout electronics recently developed for experiments at the Large Hadron Collider (LHC) at CERN. The functioning of this time based system is presented as well as its performances in terms of energy resolution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Low-Energy Physics in Neutrino LArTPCs

In this white paper, we outline some of the scientific opportunities and challenges related to detection and reconstruction of low-energy (less than 100 MeV) signatures in liquid argon time-projection chamber (LArTPC) detectors. Key takeaways are summarized as follows. 1) LArTPCs have unique sensitivity to a range of physics and astrophysics signatures via detection of event features at and below the few tens of MeV range. 2) Low-energy signatures are an integral part of GeV-scale accelerator neutrino interaction final states, and their reconstruction can enhance the oscillation physics sensitivities of LArTPC experiments. 3) BSM signals from accelerator and natural sources also generate diverse signatures in the low-energy range, and reconstruction of these signatures can increase the breadth of BSM scenarios accessible in LArTPC-based searches. 4) Neutrino interaction cross sections and other nuclear physics processes in argon relevant to sub-hundred-MeV LArTPC signatures are poorly understood. Improved theory and experimental measurements are needed. Pion decay-at-rest sources and charged particle and neutron test beams are ideal facilities for experimentally improving this understanding. 5) There are specific calibration needs in the low-energy range, as well as specific needs for control and understanding of radiological and cosmogenic backgrounds. 6) Novel ideas for future LArTPC technology that enhance low-energy capabilities should be explored. These include novel charge enhancement and readout systems, enhanced photon detection, low radioactivity argon, and xenon doping. 7) Low-energy signatures, whether steady-state or part of a supernova burst or larger GeV-scale event topology, have specific triggering, DAQ and reconstruction requirements that must be addressed outside the scope of conventional GeV-scale data collection and analysis pathways.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Systems and methods for modeling and analyzing networks

The systems and methods described herein utilize a probabilistic modeling framework for reverse engineering an ensemble of causal models, from data and then forward simulating the ensemble of models to analyze and predict the behavior of the network. In certain embodiments, the systems and methods described herein include data-driven techniques for developing causal models for biological networks. Causal network models include computational representations of the causal relationships between independent variables such as a compound of interest and dependent variables such as measured DNA alterations, changes in mRNA, protein, and metabolites to phenotypic readouts of efficacy and toxicity.

97 MATHEMATICS AND COMPUTING↗

CMS hadron calorimeter front-end upgrade for SLHC phase I

We present an upgrade plan for the CMS HCAL detector. The HCAL upgrade is required for the increased luminosity (3 * 10E34) of SLHC Phase I which is targeted for 2014. A key aspect of the HCAL upgrade is to add longitudinal segmentation to improve background rejection, energy resolution, and electron isolation at the L1 trigger. The increased segmentation is achieved by replacing the hybrid photodiodes (HPDs) with silicon PMTs (SIPMs). We plan to instrument each fiber of the calorimeter with an SIPM (103,000 total). We will then electrically sum outputs from selected SIPMs to form the longitudinal readout segments. In addition to having more longitudinal information, the upgrade plans include a new custom ADC with matched sensitivity and timing information. The increased data volume requires higher speed transmitters and the additional power dissipation for the readout electronics requires better thermal design, since much of the on-detector infrastructure (front-end electronics crates, cooling pipes, optical fiber plant, etc.) will remain the same. We will report on the preliminary designs for these upgraded systems, along with performance requirements and initial design studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new large radius imaging plate camera for high-resolution and high-throughput synchrotron x-ray powder diffraction by multiexposure method

A new large radius imaging plate diffraction camera for high-resolution and high-throughput synchrotron x-ray powder diffraction by means of multiple exposures has been developed for an insertion device beamline of SPring-8, Japan. The new imaging plate camera consists of a large radius cylindrical shape imaging plate cassette that is 400 mm in length and 954.9 mm in cylinder radius. The cassette is designed to be mounted on the 2{theta} arm of the diffractometer of BL15XU in SPring-8. One imaging plate covers 24 deg. and several times of exposure changing the 2{theta}-setting angle is necessary to obtain whole powder diffraction data up to a high angle region. One pixel of the imaging plate corresponds to 0.003 deg. in 2{theta} when the readout pixel size is 50 {mu}m squares. Separately collected data are translated to 2{theta}-intensity format and are connected by comparing the peak and background intensity included in the overlapped area. The exposure time is less than 120 s for most samples and the readout time is about 3 min; thus, the total measurement time for one powder diffraction pattern is less than 20 min. The measurement time is the same order as the continuous 2{theta}-scanning method of the third generation synchrotron powder diffractometer. The angular resolution of the new imaging plate camera was evaluated by comparing the full width at half maximum of the 111 reflection of NBS-Si. The observed angular resolution is not so high as a powder diffractometer with a Si or a Ge analyzer monochromator in the third generation synchrotron facility but higher than a powder diffractometer with a Ge analyzer monochromator at a bending magnet beamline of the second generation synchrotron. The Rietveld analysis of NBS-CeO{sub 2} was successfully carried out with the data taken by the new imaging plate camera.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗