Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data Center”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Development of a Knowledge Graph for Dataset Discovery and Identification at a NASA Data Center

The NASA Goddard Earth Sciences Data and Information Services Center (GES DISC) archives and distributes hundreds of Earth Science data collections to the public. These collections are used in research, resulting in the publication of thousands of scientific papers each year. As new users come to GES DISC for data, it is important for them to understand how prior research used the data. To help researchers, a knowledge graph (KG) was designed and implemented to connect publication citations with dataset metadata. The relationships created in the graph have the potential to allow the Web applications that utilize this information to directly connect the publication to the GES DISC datasets and services. These relationships are demonstrated using a web application prototype. In addition, the graph can also make connections between publications, datasets, and measurements based on the mentions of datasets and their attributes in the publications. To demonstrate this capability, a web application was created that takes the excerpt from the publication and returns a most likely dataset and measurement pairing, ranking the results based on how often these datasets and measurements were used in prior publications.

Nathaniel Crosby↗

Shuttle Data Center File-Processing Tool in Java

A Java-language computer program has been written to facilitate mining of data in files in the Shuttle Data Center (SDC) archives. This program can be executed on a variety of workstations or via Web-browser programs. This program is partly similar to prior C-language programs used for the same purpose, while differing from those programs in that it exploits the platform-neutrality of Java in implementing several features that are important for analysis of large sets of time-series data. The program supports regular expression queries of SDC archive files, reads the files, interleaves the time-stamped samples according to a chosen output, then transforms the results into that format. A user can choose among a variety of output file formats that are useful for diverse purposes, including plotting, Markov modeling, multivariate density estimation, and wavelet multiresolution analysis, as well as for playback of data in support of simulation and testing.

Barry, Matthew R.↗

Alaska Climate Data Center (DOE Final Report)

This final report contains a summary of work accomplished in the establishment of a Climate Data Center at the International Arctic Research Center, University of Alaska Fairbanks.

99 GENERAL AND MISCELLANEOUS↗

Project Phase 1 Report: Reducing Data Center Peak Cooling Demand and Energy Costs With Cold Underground Thermal Energy Storage (Cold UTES)

Cold Underground Thermal Energy Storage (Cold UTES) is an ultra-long duration grid energy storage technology. With Cold-UTES, low-cost grid power is converted to cold thermal energy and stored in the native subsurface rock at the point of use. Cold UTES is one approach within the general category of engineered geothermal systems. Cold UTES for peak-hour cooling of data centers (DCs) was studied for deployment in Maricopa County, Arizona and Loudoun County, Virgina using thermal storage capacities from 4 GWh-th to over 1,000 GWh-th (>1 Terawatt-hour). The two sites have different power and transmission systems, available grid energy resources, daily and seasonal load profiles, weather conditions, and grid regulatory requirements. The study results indicate high value for both locations and because of this, likely indicates value across most of the US and the world. The basis of the study was a 1,000 MW-e hourly electric use of DC computing and auxiliary loads, which was modeled as 1 GW-th of thermal load to a dry cooled heat rejection system - i.e. a cooling system that does not consume water. The electric power required for cooling the DC varies as the air temperature changes. In cold weather only the dry-coolers are used, with an electrical load for cooling load as low as 10 MW-e. In hot summer hours, chillers and dry- coolers are required, which raises the electrical load for cooling load to as much as 300 MW-e. The continuous and peak cooling electrical loads result in a grid interconnection requirement of no less than 1,300 MW-e. From both a grid and thermal design modeling perspective the 1.3 GW-e could either be a single facility or result from the total load at multiple sites.

15 GEOTHERMAL ENERGY↗

Enhancing Discoverability and Management of Atmospheric Data at Scale: Solutions from the ARM Data Center

The Atmospheric Radiation Measurement (ARM) is a multi-laboratory and multi-institutional U.S. Department of Energy (DOE) Office of Science National User Facility. The ARM Data Center (ADC), located at Oak Ridge National Laboratory, collects, archives, and shares vast atmospheric data crucial for climate research. The ADC manages over 7 PB of data from 460 instruments worldwide, processing it into more than 11,000 diverse data products using the Network Common Data Form (NetCDF) for machine-independent accessibility. The primary challenge addressed in this paper is the efficient management and distribution of vast and diverse datasets essential for the climate research community, enhancing accessibility through advanced tools like Data Discovery. The ADC has developed advanced infrastructure and software architecture to handle the continuous influx of heterogeneous data to enhance data discoverability, resulting in increased scientific collaboration. In 2023, users from over 34 countries downloaded and utilized ARM data, resulting in 1,455 publications. The ADC’s efforts have significantly improved the discoverability and usability of atmospheric data, fostering extensive scientific research and collaboration. This paper details the solutions implemented by the ADC team for efficient data discovery and distribution, and it demonstrates ARM’s capability of staging processed data for scientific analysis.

Shah, Chirag [ORNL] (ORCID:0000000203145737)↗

Preliminary Analysis of Nuclear-Powered Data Center Scenarios

This report provides a comprehensive analysis of the potential for nuclear energy to meet the growing energy demands of data centers (DCs). It evaluates the technical, economic, and socio-environmental implications of coupling Nuclear Power Plants (NPPs) with DCs, providing initial responses to several key research questions: What is the potential increased energy demand from DCs in the U.S., in the short, medium and long term? The U.S. is experiencing a rapid increase in energy demand from DCs, with projections indicating a total increase of 24-74 GWy(e) by 2028. Meeting this demand with nuclear energy would require 27–85 GWe of installed capacity. While this surge is expected to slow in the long term, the DC industry needs reliable, scalable, and clean energy sources. How much nuclear capacity can be deployed to meet DC demand and in which timeframe? Several pathways for increasing nuclear capacity were identified, including uprates, restarts of recently retired reactors, power purchase agreements with existing fleet, and new construction. Approximately 20‒28 GWe of nuclear capacity could be dedicated to DCs by the early 2030s. How much High Assay Low Enriched Uranium (HALEU) would be needed to support some nuclear deployment scenarios for DCs? Meeting the deployment targets announced by Google and Amazon for the Kairos Power Fluoride-Salt-Cooled High-Temperature Reactor or KP-FHR (~500 MWe by 2035) and the Xe-100 (~1 GWe by 2040), respectively, requires ramping up 19.75% enriched HALEU production to ~6 t/yr by 2040. What types of nuclear energy/DC coupling options exist, and what are the different benefits/challenges? Five coupling options were analyzed, ranging from grid-connected configurations to colocated, behind-the-meter setups. Key design considerations include the proximity to high- and/or medium-voltage transmission lines, the desired internal fault tolerance, and the sources of alternative/backup power during outages. Each coupling option offers unique benefits and challenges in terms of reliability, system costs, regulation, timeline, etc. A list of NPP/DC deployment scenarios was developed, considering existing or newly built NPP or DC projects. Colocated DCs with new small modular reactors or large reactors on greenfield and brownfield sites are the focus of this report. What types of reactors, especially what size, may be incentivized by DCs? Reactor sizing optimization revealed that the ideal reactor size and number of units depend on DC demand, coupling configurations defined in this report, and other economic factors. Larger reactors are preferred for high-demand DCs and grid-connected systems, while larger number of smaller reactors are better suited for DC configurations without grid backup. Which sites may be compatible with co-located nuclear-powered DCs? Siting those projects is a complicated evaluation factoring local water resources, grid connection availability and reliability, IT infrastructure, local work force, proximity to population zones, etc. For this effort greenfield and brownfield sites such as retired coal-fired plants were used to evaluate this question. This evaluation is not meant to recommend any particular site but it highlights key siting criteria and demonstrates large-scale site availability. What are the socio-economic impacts of co-located nuclear-powered DCs? Those projects generate substantial economic benefits to the local economy, particularly in urban settings. Hyperscale DCs colocated with nuclear power plants (sized around 1 GW of power) can create nearly 1,700 jobs for annual operations and more than 7,300 jobs among the supply chain and local businesses as a result of increased household spending. Rural projects also provide significant benefits, but at lower magnitudes compared to urban deployments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Astronomical Data Center Bulletin, volume 1, no. 1

Information about work in progress on astronomical catalogs is presented. In addition to progress reports, an upadated status list for astronomical catalogs available at the Astronomical Data Center is included. Papers from observatories and individuals involved with astronomical data are also presented.

Warren, W. H., Jr.↗

Exploring the Limits of Cooling for Extreme Heat Flux Applications: Data Centers and Power Electronic

We developed an Extreme Heat Flux Micro-cooler (EHFµ-C) capable of removing heat flux of ~1 kW/cm 2 with a small temperature rise ~10°C. This represents greater than 10× reduction in thermal resistance compared to the state-of-the-art single-phase cooling technologies (~0.5 cm 2 -°C/W) that greatly increases the efficiency, resulting in improved performance and reliability for microprocessors and power electronics. The EHFµ-Cooler utilizes liquid wicking (no pump) and thin-film evaporation in a 30 µm thick wick porous microstructure such as copper inverse opal (CIO), silicon and AlN pin fins along with a 3D manifold (copper wiremesh and silicon) with liquid routing and vapor extraction channels achieving an unprecedented vapor quality ~ >0.9. The proposed EHFµ-Cooler significantly reduces device temperature, resulting in 25-50% improvement in reliability and device performance. Based on very conservative estimates, the total energy saving for data centers due to improved performance can be 6 billion kWh/year (>$300M). Better cooling, leading to more efficient, higher performance and more reliable power electronics, would save the nation 3 Quad of primary energy in 2030. Just for automotive application, a 10% increase in fuel efficiency for SiC-based power electronics equates to >20 million gallons of fuel savings annually. The proposed EHFµ-Cooler technology ensures the United States maintains its technological lead in high-performance computing and high-power electronics, while at the same time improving the energy efficiency, and as a result reducing energy-related emissions such as greenhouse gases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data Center IT Equipment Energy Assessment Tools: Current State of Commercial Tools, Proposal for a Future Set of Assessment Tools

This research project, which was conducted during the Summer and Fall of 2011, investigated some commercially available assessment tools with a focus on IT equipment to see if such tools could round out the DC Pro tool suite. In this research, the assessment capabilities of the various tools were compiled to help make “non-biased” information available to the public. This research should not be considered to be exhaustive on all existing vendor tools although a number of vendors were contacted. Large IT equipment OEM’s like IBM and Dell provide their proprietary internal automated software which does not work on any other IT equipment. However, found two companies with products that showed promise in performing automated assessments for IT equipment from different OEM vendors. This report documents the research and provides a list of software products reviewed, contacts and websites, product details, discussions with specific companies, a set of recommendations, and next steps. As a result of this research, a simple 3-level approach to an IT assessment tool is proposed along with an example of an assessment using a simple IT equipment data collection tool (Level 1, spreadsheet). The tool has been reviewed with the Green Grid and LBNL staff. The initial feedback has been positive although further refinement to the tool will be necessary. Proposed next steps include a field trial of at least two vendors’ software in two different data centers with an objective to prove the concept, ascertain the extent of energy and computational assessment, ease of installation and opportunities for continuous improvement. Based on the discussions, field trials (or case studies) are proposed with two vendors – JouleX (expected to be completed in 2012) and Sentilla.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Satellite Situation Center data system for magnetospheric science planning

Critical problems in planning coordinated observation campaigns for magnetospheric science include the need to predict time intervals when one or more observing satellites or ground stations will be connected along magnetic field lines to other observation sites, or when such sites will be located within magnetospheric regions of common interest. The Satellite Situation Center (SSC) was created at the National Space Science Data Center (NSSDC) during the International Magnetospheric Study in the 1970s to address these problems. The SSC Data System has evolved since that era to support potentially complex queries by SSC staff and has now been opened to NASA Science Internet access via the NSSDC On-line Data Information System (NODIS). The SSC software, ephemeris data base, and access modes are described for the Version 2.1 release in 1993.

Aist-Sagara, L.↗

Lunar laser ranging data deposited in the National Space Science Data Center: Filtered observations for 1971 July through 1971 December and unfiltered photon detections for 1972 January through 1972 June

Documentation to be used in conjunction with data deposited in the National Space Science Data Center is presented which concerns the filtered observations obtained during laser ranging operations between the McDonald Observatory and the Apollo 11, 14, and 15 reflectors, and the unfiltered photon detections. As part of the Lunar Laser Ranging Experiment, three widely separated reflector arrays were placed on the moon. Laser ranging equipment, both ground based on lunar based, is described, and coordinates of the intersection of the polar and transverse axes of the telescope are given. Filtered and unfiltered data are defined and discussed.

Mulholland, J. D.↗

Characterizing and Modeling Cloud Applications/Jobs on a Google Data Center

In this paper, we characterize and model Google applications and jobs, based on a 1-month Google trace from a large-scale Google data center. We address four contributions: (1) we compute the valuable statistics about task events and resource utilization for Google applications, based on various types of resources and execution types; (2) we analyze the classification of applications via a K-means clustering algorithm with optimized number of sets, based on task events and resource usage; (3) we study the correlation of Google application properties and running features (e.g., job priority and scheduling class); (4) we finally build a model that can simulate Google jobs/tasks and dynamic events, in accordance with Google trace. Experiments show that the tasks simulated based on our model exhibit fairly analogous features with those in Google trace. 95+ % of tasks' simulation errors are 20 %, confirming a high accuracy of our simulation model.

Di, Sheng↗