Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detection Limit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Ultra low background time projection alpha particle detector ( Phase II Final Scientific/Technical Report)

When alpha particles are emitted into a gas they create an ionization track of gas ions and electrons. In our commercial UltraLo instrument we apply a voltage between a planar sample and an anode, integrate the anode signal as it collects the electrons, and distinguish between alphas emitted from the sample and elsewhere (anode, sidewalls) by the duration and shape of the resultant signal. The major contributors limiting the instrument’s lower detection limit are cosmic rays that pass through the detector close to the sample and Rn decays that produce charge tracks the originate in the gas and end on the sample. In this work we proposed to identify and reject these events by converting the anode into a multi-pixel array and operating in time projection mode. Cosmic rays would be eliminated by generating charge on many pixels, while charge collection asymmetry would distinguish between sample events (Bragg curve up) and Rn events (Bragg curve down). We therefore proposed to modify an UltraLo by pixilating its anode, developing low noise, low power multiplexed electronics to track each pixel’s signal individually, and develop analysis software to make the required discriminations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advances in PFAS Monitoring and Remediation Using a Functionalized Material Approach - 20080

The growing global concerns about the effects to public health from human exposure to per- and polyfluoroalkyl substances (PFAS) motivates the development of strategies for reliable monitoring of PFAS in environmental streams, as well as for their rapid, effective removal if detected. For the continuous PFAS monitoring, an inexpensive, field-deployable, in situ sensor is urgently needed; yet the prevalent in situ techniques often struggle to strike a balance between the practical sensitivity and selectivity demands of the real world. Similarly, for effective PFAS removal, strategies for their fast, selective, and quantitative capture are desired, yet the present commercially available sorbents are unable to meet the requirements of rapid, quantitative capture of all PFAS components, and are notably inefficient in removing the more toxic smaller chains. To address these twin challenges, Pacific Northwest National Laboratory is developing strategies for improved detection and remediation of PFAS. For the rapid, selective, quantitative removal of PFAS from environmental streams, the strategy relies on designing capture probes with exclusively tailored electronic and spatial affinities for the PFAS that are able to selectively capture them from environmental streams. For the in situ detection and quantification of PFAS in complex, multicomponent matrices such as groundwater, the approach relies on the targeted capture of specific PFAS by these PFAS-specific capture probes immobilized on a platform. The platform acts as an electrode to directly measure PFAS concentration through a proportional change in electrical response upon their capture. A combination of optimization of platform design and incorporation of additional, sensitive detection modalities have allowed us to achieve detection limits as low as 0.5 ng/L for detection of PFAS compounds (compared to the 70 ng/L Health Advisory Limit of the U.S. Environmental Protection Agency). (authors)

47 OTHER INSTRUMENTATION↗

Dielectrophoresis assisted rapid, selective and single cell detection of antibiotic resistant bacteria with G-FETs

Time-consuming, expensive and low sensitivity diagnostic methods used for monitoring bacterial infections lead to unnecessary or delays in prescription of the right antibiotic treatment. Determining an optimal clinical treatment requires rapid detection and identification of pathogenic bacteria and their sensitivity to specific antimicrobials. However, diagnostic devices that meet all of these criteria have proven elusive thus far. Graphene field effect transistors (G-FET) are a promising solution, since they are highly sensitive to chemical/biological modification, can have fast detection times and can be placed on different substrates. Here, by integrating specific peptide probes over G-FETs, we present a proof-of-concept study for species and strain specific label-free detection of clinical strains of pathogenic bacteria with high specificity and sensitivity. We found that pyrene-conjugated peptides immobilized on G-FETs were capable of detecting pathogenic Staphylococcus aureus at the single-cell level and discriminate against other gram-positive and gram-negative bacterial pathogens. A similar device was able to discriminate between antibiotic resistant and sensitive strains of Acinetobacter baumannii , suggesting that these devices can also be used for detecting antibiotic resistive pathogens. Furthermore, a new means of enhancing attachment, electric-field assisted binding, reduced the detection limit to 104 cells/ml and the detection time to below 5 minutes. Here, the combination of single step attachment, inexpensive production, rapid, selective and sensitive detection suggest G-FETs plus pyrene-conjugated peptides are a new platform for solving major challenges faced in point of care diagnostics to fight infectious diseases and antimicrobial resistance.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Vacuum-ultraviolet absorption cross-sections of functionalized four-carbon species

Absorption cross-sections were measured in the vacuum ultraviolet from 5.17 – 9.92 eV using differential absorption spectroscopy for 33 four-carbon species: n-butane, trans-2-butene, cis-2-butene, butanal, butyric acid, ethyloxirane, trans-2,3-dimethyloxirane, cis-2,3-dimethyloxirane, 2-methyloxetane, 2,2'-bioxirane, vinyl oxirane, 3,4-epoxybutan-2-one, diacetyl, diethyl ether, ethyl vinyl ether, vinyl acetate, acetic anhydride, 1-butanol, 3-buten-1-ol, 1–hydroxy-butan-2-one, 1–hydroxy-butan-3-one, 2,3-epoxybutan-1-ol, 3,4-epoxybutan-1-ol, 2-oxetanemethanol, butanone, methyl vinyl ketone, 4H-1,3-dioxine, allyl formate, 2-oxobutanal, 4-hydroxybutanal, 2-methyloxetan-3-one, cis–but-2-en-1-ol, and trans-2–but-enal. Uncertainties were quantified in all cases by accounting for errors in gas-phase concentration, experimental repeatability, and signal-to-noise ratio as a function of photon energy. With the exception of 2-oxobutanal, which is reported with an uncertainty of 10%, convolving the sources of error using the root-sum-square method led to an upper limit of 5% uncertainty above the detection limit, which is largely attributable to chemical purity. Here, the primary objective of the present work is to provide absolute cross-sections along with quantified uncertainty limits. The majority of the absorption spectra, which reflect electronic transitions such as σ → σ* and n → σ*, are reported for the first time and provide insight into fundamental chemical physics, such as vibrational band structure and Rydberg transitions. The quantitative spectra in the present work facilitates the discovery of chemical intermediates that support improvement in the accuracy of computational models for low-temperature combustion and atmospheric chemistry.

biofuels↗

A molecular line scan in the Hubble deep field north

We present a molecular line scan in the Hubble Deep Field North (HDF-N) that covers the entire 3 mm window (79-115 GHz) using the IRAM Plateau de Bure Interferometer. Our CO redshift coverage spans z ≲ 0.45, 1 ≲ z ≲ 1.9 and all z ≳ 2. We reach a CO detection limit that is deep enough to detect essentially all z > 1 CO lines reported in the literature so far. We have developed and applied different line-searching algorithms, resulting in the discovery of 17 line candidates. We estimate that the rate of false positive line detections is ∼2/17. We identify optical/NIR counterparts from the deep ancillary database of the HDF-N for seven of these candidates and investigate their available spectral energy distributions. Two secure CO detections in our scan are identified with star-forming galaxies at z = 1.784 and at z = 2.047. These galaxies have colors consistent with the 'BzK' color selection and they show relatively bright CO emission compared with galaxies of similar dust continuum luminosity. We also detect two spectral lines in the submillimeter galaxy HDF 850.1 at z = 5.183. We consider an additional nine line candidates as high quality. Our observations also provide a deep 3 mm continuum map (1σ noise level = 8.6 μJy beam{sup –1}). Via a stacking approach, we find that optical/MIR bright galaxies contribute only to <50% of the star formation rate density at 1 < z < 3, unless high dust temperatures are invoked. The present study represents a first, fundamental step toward an unbiased census of molecular gas in 'normal' galaxies at high-z, a crucial goal of extragalactic astronomy in the ALMA era.

79 ASTRONOMY AND ASTROPHYSICS↗

Sampling for Air Chemical Emissions from the Life Sciences Laboratory II

Sampling for air chemical emissions from the Life Science Laboratory II (LSL-II) ventilation stack was performed in an effort to determine potential exposure of maintenance staff to laboratory exhaust on the building roof. The concern about worker exposure was raised in December 2015 and several activities were performed to assist in estimating exposure concentrations. Data quality objectives were developed to determine the need for and scope and parameters of a sampling campaign to measure chemical emissions from research and development activities to the outside air. The activities provided data on temporal variation of air chemical concentrations and a basis for evaluating calculated emissions. Sampling for air chemical emissions was performed in the LSL-II ventilation stack over the 6-week period from July 26 to September 1, 2016. A total of 12 sampling events were carried out using 16 sample media. Resulting analysis provided concentration data on 49 analytes. All results were below occupational exposure limits and most results were below detection limits. When compared to calculated emissions, only 5 of the 49 chemicals had measured concentrations greater than predicted. This sampling effort will inform other study components to develop a more complete picture of a worker’s potential exposure from LSL-II rooftop activities. Mixing studies were conducted to inform spatial variation in concentrations at other rooftop locations and can be used in conjunction with these results to provide temporal variations in concentrations for estimating the potential exposure to workers working in and around the LSL-II stack.

54 ENVIRONMENTAL SCIENCES↗

Direct Imaging of Extra-Solar Planets in Star Forming Regions: Lessons Learned from a False Positive Around IM Lup

Context. Most exoplanet imagers consist of ground-based adaptive optics coronagraphic cameras which are currently limited in contrast, sensitivity and astrometric precision, but advantageously observe in the near-infrared window (1 5 m). Because of these practical limitations, our current observational aim at detecting and characterizing planets puts heavy constraints on target selection, observing strategies, data reduction, and follow-up. Most surveys so far have thus targeted young systems (1 100 Myr) to catch the putative remnant thermal radiation of giant planets, which peaks in the near-infrared. They also favor systems in the solar neighborhood (d less than 80 pc), which eases angular resolution requirements but also ensures a good knowledge of the distance and proper motion, which are critical to secure the planet status, and enable subsequent characterization. Aims. Because of their youth, it is very tempting to target the nearby star forming regions, which are typically twice as far as the bulk of objects usually combed for planets by direct imaging. Probing these interesting reservoirs sets additional constraints that we review in this paper by presenting the planet search that we initiated in 2008 around the disk-bearing T Tauri star IM Lup, which is part of the Lupus star forming region (140-190 pc). Methods. We show and discuss why age determination, the choice of evolutionary model for both the central star and the planet, precise knowledge of the host star proper motion, relative or absolute (between different instruments) astrometric accuracy (including plate scale calibration), and patience are the key ingredients for exoplanet searches around more distant young stars. Results. Unfortunately, most of the time, precision and perseverance are not paying off: we discovered a candidate companion around IM Lup in 2008, which we report here to be an unbound background object. We nevertheless review in details the lessons learned from our endeavor, and additionally present the best detection limits ever calculated for IM Lup. We also accessorily report on the successful use of innovative data reduction techniques, such as the damped-LOCI and iterative roll subtraction.

D Mawet↗

Advances in PFAS Monitoring and Remediation Using a Functionalized Material Approach

The growing global concerns about the effects to public health from human exposure to per- and polyfluoroalkyl substances (PFAS) motivates the development of strategies for reliable monitoring of PFAS in environmental streams, as well as for their rapid, effective removal if detected. For the continuous PFAS monitoring, an inexpensive, field-deployable, in situ sensor is urgently needed; yet the prevalent in situ techniques often struggle to strike a balance between the practical sensitivity and selectivity demands of the real world. Similarly, for effective PFAS removal, strategies for their fast, selective, and quantitative capture are desired, yet the present commercially available sorbents are unable to meet the requirements of rapid, quantitative capture of all PFAS components, and are notably inefficient in removing the more toxic smaller chains. To address these twin challenges, Pacific Northwest National Laboratory is developing strategies for improved detection and remediation of PFAS. For the rapid, selective, quantitative removal of PFAS from environmental streams, the strategy relies on designing capture probes with exclusively tailored electronic and spatial affinities for the PFAS that are able to selectively capture them from environmental streams. For the in situ detection and quantification of PFAS in complex, multicomponent matrices such as groundwater, the approach relies on the targeted capture of specific PFAS by these PFAS-specific capture probes immobilized on a platform. The platform acts as an electrode to directly measure PFAS concentration through a proportional change in electrical response upon their capture. A combination of optimization of platform design and incorporation of additional, sensitive detection modalities have allowed us to achieve detection limits as low as 0.5 ng/L for detection of PFAS compounds (compared to the 70 ng/L Health Advisory Limit of the U.S. Environmental Protection Agency).

Per- and poly-fluorinated alkyl substances (PFAS),↗

Double ChemFET for the In-Line Monitoring of Silver Dosing in Potable Water Systems

With NASA Advanced Exploration Systems (AES) Life Support Systems (LSS) baselining ionic silver (Ag+) as the biocide of choice, development in silver monitoring technologies becomes necessary to monitor and control Ag+ release. Ion-selctive field effect transistors (ISFETs) and chemically-sensitive field effect transistors (ChemFETs) are capable of selective detection of Ag+ with reversible and low detection limit responses. However, one major hurdle to ChemFET technologies is the requirement of a reference electrode, which can leak its fill solution into the potable water system and is prone to drift requiring frequent calibration. To circumvent this issue, we are developing a double chemically-sensitive field effect transistor (dChemFET). The dChemFET uses a second ChemFET to selectively monitor the counter ion and serves in place of the reference electrode. We report our work in developing the dChemFET, starting with the development of the Ag+ and NO3- ion selective memberanes (ISMs) to be used in the ChemFETs. The Ag+ ISM has a detection range of 50-105 ppb . The counter ion ISM, NO3- ISM, has shown a detection range of 400-105 ppb. NO3- ISMs are limited in detecting at lower ppb levels required for the dChemFET application on the potable water system. In response to this issue, we also report our studies in using the Ag+ ISM to measure deionized (DI) water as a reference measurement to be implemented in-line before the Ag+ is dosed.

Lance Dean Delzeit↗

Rapid quantitative analysis of trace elements in plutonium alloys using a handheld laser-induced breakdown spectroscopy (LIBS) device coupled with chemometrics and machine learning

Here, we present the first reported quantification of trace elements in plutonium via a portable laser-induced breakdown spectroscopy (LIBS) device and demonstrate the use of chemometric analysis to enhance the handheld device's sensitivity and precision. Quantification of trace elements such as iron and nickel in plutonium metal via LIBS is a challenging problem due to the complex nature of the plutonium optical emission spectra. While rapid analysis of plutonium alloys has been demonstrated using portable LIBS devices, such as the SciAps Z300, their detection limits for trace elements are severely constrained by their achievable pulse power and length, light collection optics, and detectors. In this paper, analytical methods are evaluated as a means to circumvent the detection constraints. Three chemometric methods often used in analytical spectroscopy are evaluated; principal component regression, partial least-squares regression, and artificial neural networks. These models are evaluated based on goodness-of-fit metrics, root mean-squared error, and their achievable limits of detection (LoDs). Partial least squares proved superior for determining content of iron and nickel in plutonium metal, yielding LoDs of 15 and 20 ppm, respectively. These results of identifying the undesirable trace elements in plutonium components are critical for applications such as fabricating radioisotope thermoelectric generators or nuclear fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Simultaneous determination of hydrazine and phenyl hydrazine using 4′-(4-carboxyphenyl)-2,2′:6′,2″ terpyridine diacetonitrile triphenylphosphine ruthenium(II) tetrafluoroborate complex functionalized multiwalled carbon nanotubes modified electrode

Highlights: • A nanocomposite of ruthenium(II) terpyridine, triphenylphosphine based complex and multiwalled carbon nanotubes have been used first time for simultaneous detection of hydrazine and phenyl hydrazine. • The detection limit reported is lower as compared to other reported works. • The paper also focuses towards effect of ligand variation attached to ruthenium(II) terpyridine based complexes complex for the hydrazine and phenyl hydrazine detection. • Nanocomposite does not involve any biological entity hence high stability. - Abstract: A nanocomposite based on the incorporation of the complex 4′-(4-carboxyphenyl)-2,2′:6′,2″ terpyridine triphenylphosphine diacetonitrile ruthenium(II) tetrafluoroborate with multiwalled carbon nanotubes and ionomer supported upon a glassy carbon electrode substrate is reported and characterized with scanning electron microscopy, transmission electron microscopy and infrared spectroscopy. The electrochemical behavior and stability of the composite electrode was investigated via cyclic voltammetry. The modified electrode exhibits an electro-catalytic activity towards the oxidation of both hydrazine and phenyl hydrazine in 0.1 M phosphate buffer solution (PBS, pH 7.4). The oxidation of hydrazine and phenyl hydrazine occurs at 0.81 V and 0.32 V with limit of detection found to be 3.7 × 10{sup −7} M and 1.15 × 10{sup −7} M and having a linear range from 5 × 10{sup −6} M to 6.5 × 10{sup −3} M, and 5 × 10{sup −6} M to 0.2 × 10{sup −3} M, respectively.

36 MATERIALS SCIENCE↗

Apoferritin Protein Nanoparticles Dually labeled with Aptamer and Horseradish Peroxidase as a Sensing Probe for Thrombin Detection

A sandwich-type electrochemical aptasensor has been developed for the detection of thrombin, based on dual signal-amplification using HRP and apoferritin. Aptamer1 (Apt1) loaded on core/shell Fe3O4/Au magnetic nanoparticle (AuMNP) was used as recognition elements, and apoferritin dually labeled with Aptamer2 (Apt2) and HRP was used as a detection probe. Sandwich-type complex, Apt1/thrombin/Apt2–apoferritin NPs–HRP was formed by the affinity reactions between AuMNPs–Apt1, thrombin, and Apt2–apoferritin–HRP. The complex was anchored on a screen-printed carbon electrode (SPCE). Differential pulse voltammetry (DPV) was used to monitor the electrode response. The proposed aptasensor yielded a linear current response to thrombin concentrations over a broad range of 0.5 pM to 100 pM with a detection limit of 0.07 pM (S/N = 3). The detection signal was amplified by using apoferritin and HRP. This nanoparticle-based aptasensor offers a new method for rapid, sensitive, selective, and inexpensive quantification of thrombin, and offers a promising potential in biomarker detection and disease diagnosis. --------------------------------------------------------------------------------

aptmer↗

Individual differences in arsenic metabolism and lung cancer in a case-control study in Cordoba, Argentina

In humans, ingested inorganic arsenic is metabolized to monomethylarsenic (MMA) then to dimethylarsenic (DMA), although in most people this process is not complete. Previous studies have identified associations between the proportion of urinary MMA (%MMA) and increased risks of several arsenic-related diseases, although none of these reported on lung cancer. In this study, urinary arsenic metabolites were assessed in 45 lung cancer cases and 75 controls from arsenic-exposed areas in Cordoba, Argentina. Folate has also been linked to arsenic-disease susceptibility, thus an exploratory assessment of associations between single nucleotide polymorphisms in folate metabolizing genes, arsenic methylation, and lung cancer was also conducted. In analyses limited to subjects with metabolite concentrations above detection limits, the mean %MMA was higher in cases than in controls (17.5% versus 14.3%, p = 0.01). The lung cancer odds ratio for subjects with %MMA in the upper tertile compared to those in the lowest tertile was 3.09 (95% CI, 1.08-8.81). Although the study size was too small for a definitive conclusion, there was an indication that lung cancer risks might be highest in those with a high %MMA who also carried cystathionine {beta}-synthase (CBS) rs234709 and rs4920037 variant alleles. This study is the first to report an association between individual differences in arsenic metabolism and lung cancer, a leading cause of arsenic-related mortality. These results add to the increasing body of evidence that variation in arsenic metabolism plays an important role in arsenic-disease susceptibility.

60 APPLIED LIFE SCIENCES↗

RULING OUT STELLAR COMPANIONS AND RESOLVING THE INNERMOST REGIONS OF TRANSITIONAL DISKS WITH THE KECK INTERFEROMETER

With the Keck Interferometer, we have studied at 2 {mu}m the innermost regions of several nearby, young, dust-depleted 'transitional' disks. Our observations target five of the six clearest cases of transitional disks in the Taurus/Auriga star-forming region (DM Tau, GM Aur, LkCa 15, UX Tau A, and RY Tau) to explore the possibility that the depletion of optically thick dust from the inner disks is caused by stellar companions rather than the more typical planet-formation hypothesis. At the 99.7% confidence level, the observed visibilities exclude binaries with flux ratios of at least 0.05 and separations ranging from 2.5 to 30 mas (0.35-4 AU) over {approx}>94% of the area covered by our measurements. All targets but DM Tau show near-infrared (NIR) excess in their spectral energy distribution (SED) higher than our companion flux ratio detection limits. While a companion has previously been detected in the candidate transitional disk system CoKu Tau/4, we can exclude similar mass companions as the typical origin for the clearing of inner dust in transitional disks and of the NIR excess emission. Unlike CoKu Tau/4, all our targets show some evidence of accretion. We find that all but one of the targets are clearly spatially resolved, and UX Tau A is marginally resolved. Our data are consistent with hot material on small scales (0.1 AU) inside of and separated from the cooler outer disk, consistent with the recent SED modeling. These observations support the notion that some transitional disks have radial gaps in their optically thick material, which could be an indication for planet formation in the habitable zone ({approx} a few AU) of a protoplanetary disk.

79 ASTRONOMY AND ASTROPHYSICS↗

Photon counting for Bragg spectroscopy of quantum gases

We demonstrate a photon-counting technique for detecting Bragg excitation of an ultracold gas of atoms. By measuring the response of the light field to the atoms, we derive a signal independent of traditional time-of-flight atom-imaging techniques. With heterodyne detection we achieve photon shot-noise limited detection of the amplification or depletion of one of the Bragg laser beams. Photon counting for Bragg spectroscopy will be useful for strongly interacting gases where atom-imaging detection fails. In addition, this technique provides the ability to resolve the evolution of excitations as a function of pulse duration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Star formation in the M17 SW giant molecular cloud

The first high-sensitivity, high-resolution far-IR survey of an entire molecular cloud complex is presented. The 20 km/s M17 SW complex, in addition to the three luminous M17 sources, contains 10 sources spread over 110 pc. The 10 lower luminosity sources divide into two groups: small blister sources powered by late O stars and compact sources powered by clusters of early B stars. No compact far-IR sources with luminosities between the detection limit and 10,000 solar luminosities were detected. Three possible formation mechanisms for the stars that power the far-IR sources in the M17 SW complex are examined. Sequential formation cannot explain the sources seen throughout the complex. Some type of stochastic formation mechanism or collapse induced by a spiral density wave could explain the observations.

Jaffe, D. T.↗

Analysis of LANDSAT-4 TM Data for Lithologic and Image Mapping Purpose

Lithologic mapping techniques using the near infrared bands of the Thematic Mapper onboard the LANDSAT 4 satellite are investigated. These methods are coupled with digital masking to test the capability of mapping geologic materials. Data are examined under medium to low Sun angle illumination conditions to determine the detection limits of materials with absorption features. Several detection anomalies are observed and explained.

Podwysocki, M. H.↗