Search NASA⌕ Search

SEARCH · Search NASA

Results for “Digital Technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Using pulse shape analysis to improve the position resolution of a resistive anode microchannel plate detector

Digital signal processing techniques were employed to investigate the joint use of charge division and risetime analyses for the resistive anode (RA) coupled to a microchannel plate detector (MCP). In contrast to the typical approach of using the relative charge at each corner of the RA, this joint approach results in a significantly improved position resolution. A conventional charge division analysis utilizing analog signal processing provides a measured position resolution of 170 μm (FWHM). By using the correlation between risetime and position we were able to obtain a measured resolution of 92μm (FWHM), corresponding to an intrinsic resolution of 64μm (FWHM) for a single Z-stack MCP detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma Discriminating Scintillation Screens for Digital Transfer Method Neutron Imaging

A collaborative project between Idaho National Laboratory (INL) and Paul-Scherrer Institute (PSI) is investigating a new type of scintillation screen that uses ZnS scintillator material with a dysprosium neutron converter instead of traditional prompt converters such as 6Li. Such a screen exposed to a neutron beam creates a latent image by neutron activation of the dysprosium in the scintillator screen. The activated screen is transported into a camera box allowing the camera to read a digital image from the photons emitted by the activated scintillation screen. Such an imaging system combines modern camera-based system architecture with the approach of traditional indirect transfer method radiography. The results show for the first time that the combination of dysprosium with a scintillation material like ZnS can produce light which is measurable under common camera-based detection conditions and that neutron radiographic images of reasonable quality can be produced. The resolution was poorer than expected at ~ 300 µm, but is on the order of the desired resolution of 100 µm. Potential improvements and additional converter materials may be investigated in the future that could increase the light output and improve spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of digital electronics for the search of SHE nuclei using GARIS-II/III at RIKEN

This work describes the implementation of a digital data acquisition system for the search and study of short-lived isotopes or superheavy elements at the GARIS-III separator at the RIKEN Nishina Center. Here a reduction to 26 ± 0.5 keV in the average value of the Full Width at Half Maximum of the alpha spectrum at 7.133 MeV was achieved, combined with a reduction of the dead time of the overall system to around a few tens of nanoseconds for the detection of very fast decay chains. Moreover, we measured a reduction of the background induced by particles crossing the implantation detector using pulse shape analysis techniques. The detail of the optimization and analysis will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast neutron-gamma discrimination on neutron emission profile measurement on JT-60U

A digital signal processing (DSP) system is applied to stilbene scintillation detectors of the multichannel neutron emission profile monitor in JT-60U. Automatic analysis of the neutron-{gamma} pulse shape discrimination is a key issue to diminish the processing time in the DSP system, and it has been applied using the two-dimensional (2D) map. Linear discriminant function is used to determine the dividing line between neutron events and {gamma}-ray events on a 2D map. In order to verify the validity of the dividing line determination, the pulse shape discrimination quality is evaluated. As a result, the {gamma}-ray contamination in most of the beam heating phase was negligible compared with the statistical error with 10 ms time resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam studies at the SPEAR3 synchrotron using a digital optical mask

The 3GeV SPEAR3 synchrotron light source operates in top-up injection mode with up to 500 mA circulating in the storage ring (equivalently 392 nC). Each injection pulse contains 40–80 pC producing a contrast ratio between total stored charge and injected charge of about 6500:1. In order to study transient injected beam dynamics during user operations, it is desirable to optically image the injected pulse in the presence of the bright stored beam. In the present work this is done by imaging the visible component of the synchrotron radiation onto a digital micro-mirror-array device (DMD), which is then used as an optical mask to block out light from the bright central core of the stored beam. The physical masking, together with an asynchronously-gated, ICCD imaging camera, makes it possible to observe the weak injected beam component on a turn-by-turn basis. The DMD optical masking system works similar to a classical solar coronagraph but has some distinct practical advantages: i.e. rapid adaption to changes in the shape of the stored beam, a high extinction ratio for unwanted light and minimum scattering from the primary beam into the secondary optics. In this paper we describe the DMD masking method, features of the high dynamic range point spread function for the SPEAR3 optical beam line and measurements of the injected beam in the presence of the stored beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Safety Assurance of Software and Machine Learning Development for Nuclear Instrumentation and Controls

Digital instrumentation and control (DI&C) systems monitor and control parameters in nuclear power plants. Ensuring their safety is a critical part of ensuring overall plant safety. Nuclear power plant licensing generates thousands of safety documents that could be organized more effectively using a safety assurance case (SAC). We conducted a literature survey of SACs and created a SAC framework for DI&C software using Goal Structuring Notation (GSN). This framework focuses on four software development processes: management & assurance, pre-developed software (PDS) qualification, the Software Development Life Cycle (SDLC), and the Machine Learning Development Life Cycle (MLDLC). We organized our framework using a novel level structure that can be applied to other SACs to improve their clarity. Finally, we demonstrate how our framework can be incorporated as part of a SAC for a larger reactor system.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Understanding the Challenges in the Transition from Film Radiography in the Nuclear Power Industry

Nondestructive examination (NDE) applications in the nuclear power industry using film radiography are shrinking due to the advent of modern digital imaging technologies and advances in alternative inspection methods that do not present an ionizing radiation hazard. Technologies that are used routinely in the medical industry for patient diagnosis are being adapted to industrial NDE applications including the detection and characterization of defects in welds. From the user perspective, non-film inspection techniques provide several advantages over film techniques. It is anticipated that the shift away from the application of film radiography in the nuclear power industry represents an irreversible trend. The U.S. Nuclear Regulatory Commission (NRC) has noted this trend in the U.S. nuclear power industry and will be working to ensure that the effectiveness and reliability of component inspections is not compromised by this transition. Currently, specific concerns are associated with 1) obtaining a fundamental understanding of how inspection effectiveness and reliability may be impacted by this transition and 2) ensuring training standards and qualifications remain compatible with modern industrial radiographic practice. This paper discusses recent trends in industrial radiography and assesses their advantages and disadvantages from the perspective of nuclear power plant component inspections.

digital radiography↗

The use of a digital micromirror array as a temporal gate and spatial-filtering device for laser-induced breakdown spectroscopy and laser ablation molecular isotopic spectrometry

A digital micromirror array (DMMA) is used in a simple and inexpensive approach for spatially resolved temporal gating of atomic emission detection in laser-induced breakdown spectroscopy (LIBS). Selected mirrors in the array are actuated at a time delayed from the primary laser pulse, permitting optical gating with a response time of 160 ns while using a conventional CCD detector. Detector gating is shown to decrease noise from short-lived spectroscopic background (both continuum and N II from air), improving signal-to-background ratios by 22-times for selected samples and emission lines. The utility of rapid temporal gating is also demonstrated for the optical detection of isotopes using the laser-ablation molecular isotope spectrometry (LAMIS) experiment. Additionally, optical temporal gating and spatial filtering are used to isolate regions of the laser-induced plasma, enhancing signal from molecular emission. The potential of the simple technique for use in field-portable LIBS and LAMIS experiments is explored.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DCIS integration tests for Lungmen nuclear power plant - 370

The factory acceptance tests (FAT) for distributed control and information systems (DCIS) of Lungmen nuclear power plant (LMNPP) Units 1 and 2 were separately performed by individual suppliers for their supplied scopes. The FAT also included overlap interface tests between the separately supplied scopes, but did not include an overall integration test. There were concerned by the regulator and the public over the lack of an integration test, which was believed to be indispensable to verify the correctness and completeness of a digital system of such large scale ever applied by Taiwan Power Company (Taipower). To address these concerns and enhance confidence in the DCIS, the DCIS integration tests, including reactor water level integration test, reactor pressure integration test, integration test for turbine generator and reactor protection system, integration test for proper plant response to safety and non-safety network equipment failures, and DCIS dynamic integration test, were performed at site during Unit 1| site tests. It is to be noted that these tests were beyond the post construction tests, the pre-operational tests, and the start-up tests, which are the normal industry practice and formally required by the regulator. A common goal for these integration tests is to verify the capability of the DCIS to transmit signal/data properly across various suppliers' equipment to actuate the final equipment. The methods and principle, the test purpose/test items/acceptance criteria and the test results for these tests are described. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Recent Developments in Dual-Laser Digital Holography for Plasma-Facing Surface Characterization

A digital holography device is currently undergoing development at the Oak Ridge National Laboratory for the purpose of measuring surface topography, with the goal of deployment as a real-time plasma-facing component diagnostic for the study of materials that could be utilized in a nuclear fusion device. The holography system utilizes one or two lasers depending on the scale of surface features under measurement. Measurements of surface roughness were performed in a single-laser mode and compared with the data from profilometry, with a linear correlation of increased holographic measurement fidelity as surfaces became smoother. Characterization of the dual-laser operating mode has been performed via surface measurement of stainless steel targets with ``stair-step'' features in various sizes. Results demonstrated that surface features with known sizes as small as 25.4 μm could be resolved. Measurements were within ~55 μm or less deviation from the actual sizes, and measurement accuracy was improved as feature size was increased, corresponding to the effect of noise becoming less pronounced. In conclusion, a target exposed to plasma generated by an electrothermal (ET) arc source was analyzed with flat-field correction and averaging of sequential image frames to demonstrate the improved measurement quality in preparation for future use of holography on ET arc-exposed targets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Path-Integrated X-Ray Digital Image Correlation using Synthetic Reference Images

X-rays can provide images when an object is visibly obstructed, allowing for motion measurements via x-ray digital image correlation (DIC). However, x-ray images are path-integrated and contain data for all objects between the source and detector. If multiple objects are present in the x-ray path, conventional DIC algorithms may fail to correlate the x-ray images. A new DIC algorithm called path-integrated (PI)-DIC addresses this issue by reformulating the matching criterion for DIC to account for multiple, independently-moving objects. PI-DIC requires a set of reference x-ray images of each independent object. However, due to experimental constraints, such reference images might not be obtainable from the experiment. Here, this work focuses on the reliability of synthetically-generated reference images, in such cases. A simplified exemplar is used for demonstration purposes, consisting of two aluminum plates with tantalum x-ray DIC patterns undergoing independent rigid translations. Synthetic reference images based on the “as-designed” DIC patterns were generated. However, PI-DIC with the synthetic images suffered some biases due to manufacturing defects of the patterns. A systematic study of seven identified defect types found that an incorrect feature diameter was the most influential defect. Synthetic images were re-generated with the corrected feature diameter, and PI-DIC errors were improved by a factor of 3-4. Final biases ranged from 0.00-0.04 px, and standard uncertainties ranged from 0.06-0.11 px. In conclusion, PI-DIC accurately measured the independent displacement of two plates from a single series of path-integrated x-ray images using synthetically-generated reference images, and the methods and conclusions derived here can be extended to more generalized cases involving stereo PI-DIC for arbitrary specimen geometry and motion. This work thus extends the application space of x-ray imaging for full-field DIC measurements of multiple surfaces or objects in extreme environments where optical DIC is not possible.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Why does cyber deterrence fail and when might it succeed? A framework for cyber scenario analysis

Through cyberattacks on information technology and digital communications systems, antagonists have increasingly been able to alter the strategic balance in their favor without provoking serious consequences. Conflict within and through the cyber domain is inherently different from conflict in other domains that house our critical systems. These differences result in new challenges for defending and creating resilient systems, and for deterring those who would wish to disrupt or destroy them. The purpose of this paper is to further examine the question of whether or not deterrence can be an effective strategy in cyber conflict, given our broad and varied interests in cyberspace. We define deterrence broadly as the creation of conditions that dissuade antagonists from taking unwanted actions because they believe that they will incur unacceptably high costs and/or receive insufficient benefits from taking that action. Deterrence may or may not be the most credible or effective strategy for achieving our desired end states in cybersecurity. Regardless of the answer here, however, it is important to consider why deterrence strategies might succeed under certain conditions, and to understand why deterrence is not effective within the myriad contexts that it appears fail. Deterrence remains a key component of U.S. cyber strategy, but there is little detail on how to operationalize or implement this policy, how to bring a whole-of-government and whole-of- private-sector approach to cyber deterrence, which types of antagonists can or should be deterred, and in which contexts. Moreover, discussion about how nations can and should respond to significant cyber incidents largely centers around whether or not the incident constitutes a "use of force," which would justify certain types of responses according to international law. However, we believe the "use of force" threshold is inadequate to describe the myriad interests and objectives of actors in cyberspace, both attackers and defenders. In this paper, we propose an approach to further examine if deterrence is an effective strategy and under which conditions. Our approach includes systematic analysis of cyber incident scenarios using a framework to evaluate the effectiveness of various activities in influencing antagonist behavior. While we only examine a single scenario for this paper, we propose that additional work is needed to more fully understand how various alternative thresholds constrain or unleash options for actors to influence one another's behavior in the cyber domain.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Predicting Deposition Rate and Closing the Loop on Aerosol Jet Printing with In‐Line Light Scattering Measurements

Aerosol jet printing is a compelling noncontact, digital manufacturing technology for flexible, hybrid, and conformal electronics, but batch‐to‐batch variability and process drift inhibit systematic study and translation to production environments. Emerging measurement techniques for the aerosol volume fraction, a key parameter governing deposition rate, have shown promise for real‐time response, including a recent demonstration of human‐in‐the‐loop control. By integrating improved light scattering measurements with custom software, a robust environment for real‐time monitoring is established and fully automated closed‐loop control over the deposition rate during printing is enabled. The physical basis for scattering measurements as a feedback source is examined and the quantitative insight this provides for ink development and fundamental process studies is highlighted. Three candidate process variables for closed‐loop control, namely the atomizer voltage, carrier gas flow rate, and print speed, are then evaluated. The atomizer voltage demonstrates the best extended duration validity because it addresses atomization variability directly, but carrier gas flow rate and print speed provide faster and more deterministic responses. This methodology is then demonstrated for electrical properties using a silver nanoparticle ink, maintaining 98% of printed patterns within 10% of the mean resistance value over 3 h of printing.

36 MATERIALS SCIENCE↗

Review of Computer-Aided Manufacturing (CAM) strategies for hybrid directed energy deposition

Hybrid additive manufacturing intertwines both additive and subtractive manufacturing layer by layer to digitally fabricate parts with complex geometries, improved surface finish and tight dimensional accuracies, the sum of which is difficult to obtain with any single process. Computer-Aided Manufacturing (CAM) software is required to orchestrate the machine toolpathing for both the deposition as well as the machining processes and is crucial for the successful fabrication of high quality structures. Additionally, CAM requires substantial operator input to account for challenging aspects of each fabricated structure. For example, deciding at which layer of deposition will the machining process continue to maintain access to complex cavities for finishing - internal features that would otherwise be unfinishable due to reach limitations or obstructions. Moreover, of the many commercially-available hybrid systems, each has a unique kinematic environment which can benefit from specific optimization of toolpath planning and substantial research has directly correlated toolpathing with the microstructure evolution, mechanical properties, porosity and residual stress state of the final fabricated part. This review explores the available strategies for CAM in the context of hybrid direct energy deposition, discusses the advantages and disadvantages of each and considers future CAM trends for this transformational digital manufacturing technology.

36 MATERIALS SCIENCE↗

Assessment of asymmetrical rheological behavior of cementitious material for 3D printing application

Among the multiplicity of construction methods based on digital concrete technologies, the most common one remains the extrusion-based process. Two opposed strategies have been developed in order to print a concrete structure using extrusion: the first one emphasizes the ease-of-pumping of material which is massively accelerated to ensure the stability of the structure, when leaving the extruder; the second one uses a firm mortar able to sustain the own weight of the structure during the printing, without requiring any accelerator. Both methods have their pros and cons and don't imply the same rheological requirements. Most of the recent literature assumes that both types of material (fluid and firm) follow the same trend of behavior and obey to the Von Mises plasticity criterion, while it has been demonstrated that firm cement-based materials can exhibit a pressure dependent behavior. Moreover, rheological study is mainly based on shear rheometry, while the extrusion-based printing process requires a description of the rheological behavior in compression to predict the global stability of the structure, and in tension to prevent cracks formation. This paper investigates the fresh behavior of cement paste and mortar under different solicitations (shear, compression, tension) for different water to cement ratios. The analysis of these results allows to describe the transition between a ductile fluid material (symmetrical in tension and compression) that obeys to a Von Mises plasticity criterion, and a brittle and firm material (asymmetrical in tension and compression) that requires a pressure dependent plasticity criterion in order to predict its strength under a given solicitation.

36 MATERIALS SCIENCE↗

An efficient and cost-effective microchannel plate detector for slow neutron radiography

We report a novel approach for efficiently imaging objects with slow neutrons in two dimensions is realized. Neutron sensitivity is achieved by use of a boron doped microchannel plate (MCP). The resulting electron avalanche is further amplified with a Z-stack MCP before being sensed by two orthogonally oriented wire planes. Coupling of the wire planes to delay lines efficiently encodes the position information as a time difference. To determine the position resolution, slow neutrons were used to illuminate a Cd-mask placed directly in front of the detector. Peaks in the resulting spectrum exhibited an average peak width of 329 μm FWHM, corresponding to an average intrinsic resolution of 216 μm. The center region of the detector exhibits a significantly better spatial resolution with an intrinsic resolution of <100 μm observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single photon detection with the multi-anode CLAS12 RICH detector

Recently, the first module of the hybrid-optics large-area CLAS12 RICH at JLab has been put into operation using for the first time the well known Hamamatsu H8500 MAPMT and the new single-photon dedicated H12700, for a total of about 400 MAPMTs and 25000 pixels. The photon detector must efficiently detect single photons in the visible and near-UV light region, provide a fast response for background rejection and pattern recognition, and have a spatial resolution of less than 1 cm over an area of ≈1 m 2 . Each front-end readout unit is composed of three electronic boards with specific tasks directly connected to groups of 2 or 3 sensors. The core of the readout is composed of MAROC3 and FPGA chips. The MAROC3 chip is able to discriminate the 64 signals from one MAPMT and to produce 64 corresponding binary outputs with 100% efficiency starting at a small fraction of the single-photon signal, while the FPGA chip provides 1 ns TDC capability with 8 μs maximum latency and acts as a DAQ controller. The system is created to be almost dead-time free at the foreseen 20 kHz CLAS12 trigger rate. The best working conditions for single-photon detection have been studied at laser stands, test beams, and with the JLab electron beam data. A report of the photon detector preparation, commissioning and operation is here discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The large-area hybrid-optics CLAS12 RICH: First years of data-taking

The CLAS12 deep-inelastic scattering experiment at the upgraded 12 GeV continuous electron beam accelerator facility of Jefferson Lab conjugates luminosity and wide acceptance to study the 3D nucleon structure in the yet poorly explored valence region, and to perform precision measurements in hadron spectroscopy. A large area ring-imaging Cherenkov detector has been designed to achieve the required hadron identification in the momentum range from 3 GeV/c to 8 GeV/c, with the kaon rate about one order of magnitude lower than the rate of pions and protons. The adopted solution comprises aerogel radiator and composite mirrors in a novel hybrid optics design, where either direct or reflected light could be imaged in a high-packed and high-segmented photon detector. The first RICH module was assembled during the second half of 2017 and installed at the beginning of January 2018, in time for the start of the experiment. The second RICH module, planned with the goal to be ready for the beginning of the operation with polarized targets, has been timely built despite the complications caused by the pandemic crisis and successfully installed in June 2022. Finally, the detector performance is here discussed with emphasis on the operation and stability during the data-taking, calibration and alignment procedures, reconstruction and pattern recognition algorithms, and particle identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗