Search NASA⌕ Search

SEARCH · Search NASA

Results for “Discharge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

An investigation of the reduction of carbon dioxide in a silent electric discharge

The reduction of CO2 to O2 and CO in a silent electric discharge was studied. It was found that current alone (in the ionized plasma induced by the silent electric discharge) was reponsible for the CO2 reduction process. Voltage and frequency were important only in so far as they induced current in the plasma. Pressure and temperature were of minimum influence in the process. The large power consumption in the process was recognized as resulting from the low power factor of the reactor vessel which electrically behaved like a capacitor. The power factor was subsequently improved by adding an inductive element to make the reactor vessel capacitance part of a resonant circuit. It was found that the CO2 reduction process was most efficient in terms of power vs reduction rate when a voltage was employed that was only slightly higher than that needed to induce the plasma.

Luce, R. S.↗

A pulser-sustainer carbon monoxide electric-discharge supersonic laser

Operation of a CW CO electric-discharge supersonic laser with a pulser-sustainer discharge is described. High-power operation as well as independent control over electron energy and density are demonstrated. Maximum input power achieved to date is 100 kW. The maximum output power is 6 kW or 10% of the sustainer positive-column power. Much improved performance appears possible.

Monson, D. J.↗

Measurement of non-Maxwellian electron velocity distributions in a reflex discharge

The results of a ruby laser Thomson scattering study of the space and time-resolved electron velocity distributions in a pulsed Penning discharge in hydrogen are presented. Electron densities were to the order of 10 to the 13th/cu cm and temperatures were roughly 3 eV. This point is just prior to the cessation of the discharge ohmic heating pulse. For magnetic strengths less than 200 G, Maxwellian distributions were found over an energy range six times thermal energy. Temperatures agreed with Langmuir probe data. For fields of 450 G, chaotic plasma potentials were observed to be unstable and the Thomson scattering showed that the electron velocity distributions had central temperatures of 2 eV and wing temperatures of 15-12 eV.

Phipps, C. R., Jr.↗

Measurements of kinetic processes in a self-sustained discharge XeF laser

Measurements are presented for processes occurring in XeF self-sustained discharges including fluorescence, gain, and absorption at different wavelengths as a function of F2, Xe, and He partial pressures. Time-correlated oscillograms are given for the laser discharge current, metastable XeF small-signal gain at 351.1 nm, transient absorptions at 333.6 and 363.8 nm, metastable-XeF B-state sidelight emission at about 350 nm, metastable-F emission at 634.8 nm, and metastable-F emission at 731.1 nm. It is found that He atoms are necessary for the production of metastable-XeF in its lower vibrational levels and that radiative processes and He quenching are the primary mechanisms for metastable-XeF decay. For small-signal gains of as low as about 8%/cm, the transient absorption at the laser wavelength may be as large as about 1-2%/cm.

Gower, M. C.↗

A continuously pulsed copper halide laser with a cable-capacitor Blumlein discharge circuit

Experimental characteristics of a continuously pulsed copper halide laser with a cable-capacitor Blumlein discharge circuit are reported. Quartz laser tubes 1 m in length and 1.5 and 2.5 cm in diameter were employed to study the effects of the electrical circuit, lasant, and buffer gas on laser performance. Measured properties of the Blumlein circuit are compared with an analytic solution for an idealized circuit. Both CuCl and CuBr with neon and helium buffer gas were studied. A maximum average power of 12.5 W was obtained with a 1.5 nF capacitor charged to 8 kV and discharged at 31 kHz with CuCl and neon buffer gas at 0.7 kPa in a 2.5-cm-diam tube. A maximum efficiency of 0.72 percent was obtained at 9 W average power. Measurements of the radial distribution of the power in the laser beam and the variation of laser power at 510.6 and 578.2 nm with halide vapor density are also reported. Double and continuously pulsed laser characteristics are compared, and the role of copper metastable level atoms in limiting the laser pulse energy density is discussed.

Nerheim, N. M.↗

Preionized discharge for short-wavelength laser

Laser uses helium and nitrogen gases at pressure of several atmospheres to produce emissions in visable and ultraviolet regions. Preionization of gases by transverse discharge insures that main discharge is glow instead of arc for proper charge transfer mechanism.

Laudenslager, J. B.↗

Electric discharge for treatment of trace contaminants

A radio frequency glow discharge reactor is described for removing trace oxidizable contaminants from an oxygen bearing atmosphere. The reaction chamber is defined by an inner metal electrode facing a dielectric backed by an outer conductive electrode. In one embodiment, a conductive liquid forms the conductor of an outer electrode and cools the dielectric. A resonator coupled to a variable radio frequency source generates the high voltages for creating a glow discharge in the chamber at a predetermined pressure whereby the trace contaminants are oxidized into a few simple non-toxic products that may be easily recovered. The corresponding process for removal of trace contaminants from an oxygen-bearing atmosphere with high efficiency independent of the concentration level is also disclosed.

Flamm, D. L.↗

RF radiation produced by intracloud lightning discharges

The RF radiation produced during intracloud lightning flashes is presented, together with associated fast and slow electric field changes. These data were collected during the Thunderstorm Research International Project in Florida during the summer of 1977. The RF radiation is essentially simultaneous with the fast-field change but has a tendency to peak during the initial half-cycle of the bipolar field changes associated cloud processes. This is in marked contrast to previous observations of RF radiation during return strokes in cloud-to-ground discharges and provides a clue to the physics of the intracloud discharge.

Levine, D. M.↗

Electrostatic discharge properties of selected Voyager spacecraft materials

Twelve material and component samples were exposed to an electron beam in order to measure the time history and amplitude of resultant electrostatic discharges. The typical experimental design was to mount the test article with its dielectric surface facing the beam and its conductive portion isolated from ground except by way of a shielded cable on which a discharged pulse could be observed. The behavior of the sample was then observed at bombarding energies from 20 to 100 keV in increasing 20 keV increments and then 90 to 30 keV in decreasing 20 keV increments. Observations were made at each energy for nominally two hours at an electron flux of 4 x 10 to the 9th power/sq cm/sec.

Barengoltz, J. B.↗

Scaling laws and edge effects for polymer surface discharges

Specimens of Mylar sheet were exposed to a 20 kV electron beam. The resulting surface discharge arcs were photographed and the discharge current into a metal backing plate measured as a function of time. The area of the Mylar sheet was defined by a round aperture in a close-fitting metal mask, and the current pulse characteristics were plotted against area on log-log paper. The plots appear as straight lines (due to power-law behavior) with slopes of 0.50 for the peak current, 1.00 for the charge released, 1.49 for the energy and 0.55 for the pulse duration. Evidence is presented for the occurrence of banded charge distributions near grounded edges, on both Teflon and Mylar.

Balmain, K. G.↗

Electrical discharges in the atmosphere of Venus

Data received from Venera 11 and 12 experiments involving the electrical activity of the atmosphere of Venus show that the electrical discharges occur in the cloud layer. Their energy is roughly the same as in terrestrial lightning, but with a pulse repetition frequency of the discharges which is much greater.

Ksanfomaliti, L. V.↗

Response of lead-acid batteries to chopper-controlled discharge

The results of tests on an electric vehicle battery, using a simulated electric vehicle chopper-speed controller, show energy output losses up to 25 percent compared to constant current discharges at the same average current of 100 A. However, an energy output increase of 22 percent is noticed at the 200 A average level and 44 percent increase at the 300 A level using pulse discharging. Because of these complex results, electric vehicle battery/speed controller interactions must be considered in vehicle design.

Cataldo, R. L.↗

Effect of variable energy input on nitrogen fixation in instantaneous linear discharges

The reported analysis implies that the number of molecules of NO produced per joule of discharge varies with input energy. The calculations assume a cylindrical symmetry but the results are consistent with equivalent calculations using spherical symmetry. If NO yield does vary with input energy, extrapolation of laboratory experiments using small sparks is not as straightforward as has previously been assumed. Calculated curves for the yield of NO as a function of discharge energy are presented and are compared with experimental values and other theoretical values.

Chameides, W. L.↗

Plasma polymerization of ethylene in an atmospheric pressure-pulsed discharge

The polymerization of ethylene in an atmospheric pressure-pulsed discharge has been studied. Partial pressures of ethylene up to 4 kN/sq m were used with helium as a diluent. Deposition rates (on glass slides) were the same throughout the discharge volume over a wide range of operating conditions. These rates were in the 1-2 A/sec range. The films were clear, soft, and showed good adhesion to the glass substrates. Oligomers large enough to visibly scatter 637.8-nm light were observed in the gas phase under all conditions in which film deposition occurred. The experimental results suggest that Brownian diffusion of these oligomers was the rate-limiting step in the film deposition process.

Donohoe, K.↗

Voltage feed through apparatus having reduced partial discharge

A voltage feed-through apparatus, having reduced partial discharge, has an electrical conductor and an electrical terminal connected thereto. A semiconductor sleeve surrounds the conductor for reducing the electric field concentration at the metallic conductor surface and consequently reducing the partial discharge occurrences. An insulator sleeve encircles the semiconductor sleeve. A metallic sleeve surrounds a portion of the terminal. Another insulator is connected to the metallic sleeve and surrounds a portion of the insulator sleeve forming a space therebetween. Another metallic sleeve spaced from the first metallic sleeve surrounds a portion of the other insulator.

Peck, S. R.↗

Langmuir probe measurements of double-layers in a pulsed discharge

Langmuir probe measurements were carried out which confirm the occurrence of double-layers in an argon positive column. Pulsing the discharge current permitted probe measurements to be performed in the presence of the double-layer. Supplementary evidence, obtained from DC and pulsed discharges, indicated that the double-layers formed in the two modes of operation were similar. The double-layers observed were weak and stable; their relation to other classes of double-layers are discussed, and directions for future work are suggested.

Levine, J. S.↗

Lithium battery discharge tests

The long term discharge of a variety of lithium cells was characterized and the susceptibility of the cells to chemical variation during the slow discharge was tested. A shunt resistor was set across the terminals to monitor the voltage as a function of time. Failures were identified by premature voltage drops.

Johnson, C. J.↗

Langmuir probe measurements of double-layers in a pulsed discharge

Langmuir probe measurements have been carried out which confirm the occurrence of double-layers in an argon positive column. Pulsing the discharge current permitted probe measurements to be performed in the presence of the double-layer. Supplementary evidence, obtained from dc and pulsed discharges, indicated that the double-layers formed in the two modes of operation were similar. The double-layers observed were weak and stable; their relation to other classes of double-layers is discussed, and directions for future work are suggested.

Levine, J. S.↗