Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distribution Operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Development and Validation of Two-Phase Flow Models in MOOSE and Application to Molten Salt Reactors

Two-phase flow in Molten Salt Reactors (MSRs) is important as it impacts reactivity evolution, reactor transient response, and the removal of species dissolved in the molten salt through gas phase transfer. Therefore, accurately predicting the gas distribution and the associated liquid-gas interface area in MSRs is essential for their design and operation. Recently, we integrated a new two-phase model into Idaho National Laboratory (INL)’s Multiphysics Object-Oriented Simulation Environment (MOOSE): a multi-D generalization of a mixture drift-flux model. It provides greater computational efficiency, which is typically preferred for modeling reactor transients. However, the mixture model’s accuracy in capturing void distribution and interfacial area in MSRs still needs to be assessed. This article begins with a description of the mathematical framework for the two-phase model implemented in MOOSE. It then presents validation of these models against relevant experimental data. Finally, the model is applied to the Molten Salt Reactor Experiment case study, analyzing various operational conditions such as different rates of fission product volatilization and diverse cover gas entrainment scenarios at the reactor pump. The article concludes by assessing the suitability of the mixture drift-flux model for capturing the two-phase flow dynamics critical to MSR operations

42 - ENGINEERING↗

Flaw Tolerance Assessment for DOE Standard SNF Dry Storage Canisters - 26550

The U.S. DOE has designed four spent nuclear fuel (SNF) dry storage canisters for storing DOE standardized SNFs. The DOE standard canisters are cylindrical shells with a diameter of 24 inches (610 m) or 18 inches (457 m), a wall thickness of 0.5 inches (12.7 m) or 0.375 inches (9.53 m), and a length of 15 feet (4.57 m) or 10 feet (3.05 m). These DOE canister geometries are completely different from commercial canisters. The latter may experience chloride-induced stress cracking corrosion (CI-SCC) because they are stored near coastal regions. The former may not experience CI-SCC but face different challenges because they are stored in the SNF storage facilities. Because of large residual stresses, mechanical flaws may occur in the DOE canisters during long-distance transportation or lifting handling. To date, only limited structural integrity analyses were carried out through drop tests on the DOE canisters, but a more general flaw tolerance assessment has not been performed. Therefore, the failure assessment diagram (FAD)-based fracture mechanics method, as codified by the latest API 579-1/ASME FFS-1-2021 Edition, is adopted in this work to assess surface flaw tolerance for DOE canisters under operation loading and welding residual stresses (WRS), where the new code-recommended WRS distributions are used. To more adequately consider the transverse distribution of WRS, an equivalent WRS distribution is proposed to account for the WRS reduction with distance from the weld centerline. Moreover, the closed-form solutions of stress intensity factor K, which serves as the crack driving force during subcritical crack growth, are developed from the tabular data of the K factors provided in API 579-1/ASME FFS-1 and used to determine more accurate flaw sizes at flaw instability. Subsequently, the Level 2 assessment procedures with 12 assessment steps, as codified and detailed in API 579-1 and ASME FFS-1, are followed to assess the flaw tolerance for the surface flaws in the DOE standard canisters with consideration of normal or accident operation loads combined with WRS. The assessment results show that the four designs of DOE standard canisters can tolerate all surface flaws that meet the code permitted maximum sizes of a flaw length of 8 inches (i.e., 200 mm) and a flaw depth of 80% wall thickness. This demonstrates that all designs of DOE standard canisters are robust and reliable.

DOE standard canister↗

Nuclear Safety [Vol. 36, No. 1, January-June 1995]

Nuclear Safety is a journal that covers significant issues in the field of nuclear safety. Its primary scope is safety in the design, construction, operation, and decommissioning of nuclear power reactors worldwide and the research and analysis activities that promote this goal, but it also encompasses the safety aspects of the entire nuclear fuel cycle, including fuel fabrication, spent-fuel processing and handling, and nuclear waste disposal, the handling of fissionable materials and radioisotopes, and the environmental effects of all these activities. Table of Contents for this issue follows. THE CHORNOBYL ACCIDENT: 1 The Chornobyl Accident Revisited, Part II: The State of the Nuclear Fuel Located Within the Chornobyl Sarcophagus, A A. Borovoi and A. R. Sich; GENERAL SAFETY CONSIDERATIONS: 33 Nuclear Power Safety in Central and Eastern Europe, R. Wilson; 46 Safety of Nuclear Power Reactors in the Former Eastern European Countries, S. Chakraborty; 53 Technical Note: On the Definition of Common-Cause Failures, H. Paula; ACCIDENT ANALYSIS: 58 Modeling and Analysis of Core-Debris Recriticality During Hypothetical Severe Accidents in the Advanced Neutron Source Reactor, S.-H. Kim, V. Georgevich, D. B. Simpson, C. O. Slater, and R. P. Taleyarkhan; 68 Ignitability of Hydrogen/Oxygen/Diluent Mixtures in the Presence of Hot Surfaces, R. K. Kumar and G. W. Koroll; 94 Coupled RELAP5 and CONTAIN Accident Analysis Using PVM, K. A. Smith, A. J. Baratta, and G. E. Robinson; CONTROL AND INSTRUMENTATION: 109 Application of Fuzzy Logic in Nuclear Reactor Control Part I: An Assessment of State-of-the-Art, A. S. Heger, N. K. Alang-Rashid, and M. Jamshidi; DESIGN FEATURES: 122 Twenty-Third DOE/NRC Nuclear Air-Cleaning and Treatment Conference, R. R. Bellamy, J. J. Hayes, and M. W. First; ENVIRONMENTAL EFFECTS: 135 Atmospheric Dispersion and the Radiological Consequences of Normal Airborne Effluents from a Nuclear Power Plant, D. Fang, C. Z. Sun, and L. Yang; 142 Calculation of Distribution Coefficients for Radionuclides in Soils and Sediments, I. Puigdomenech and U. Bergstrom: OPERATING EXPERIENCES: 155 Reactor Shutdown Experience, Compiled by J. W. Cletcher; U.S. NUCLEAR REGULATORY COMMISSION INFORMATION AND ANALYSES: 158 Operating Experience Feedback Report—Reliability of Safety-Related Steam Turbine-Driven Standby Pumps Used in U.S. Commercial Nuclear Power Plants, J. R. Boardman; 166 Turbine Building Hazards, H. L Ornstein; RECENT DEVELOPMENTS: 169 Reports, Standards, and Safety Guides, D. S. Queener; 175 Proposed Rule Changes as of Dec. 31,1994; ANNOUNCEMENTS: 32 Harvard School of Public Health In-Place Filter Testing Workshop; 134 International Conference on Advances in the Operational Safety of Nuclear Power Plants; 193 30th Tennessee Industries Week; 193 DOE Technical Standards Program 1995 Workshop; 194 Multiphase Flow Experiments and Instrumentation; 180 The Authors; 185 Indexes to Nuclear Safety, Volumes 34 and 35.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Model-Based Detection of Coordinated Attacks (DCA) in Distribution Systems

The fast-paced growth in digitization of smart grid components enhances system observability and remote-control capabilities through efficient communication. However, enhanced connectivity results in heightened system vulnerability towards cybersecurity risks in the cyber-physical power system. Coordinated cyber-attacks (CCA), when undetected, lead to system-wide impact in terms of large disturbances or widespread outages. Detecting CCA in the cyber layer is critical to thwart cyber-attacks in real-time before the attack impacts the physical system. The challenge of locating CCA stems from the complex grid dynamics, making it difficult to distinguish between normal operational variations and cyber-attack impact. CCA often employs multiple attack vectors targeting geographically distributed components, further complicating CCA identification. Existing research in intrusion detection is primarily focused on the transmission network and limited to detecting individual attacks. In this paper, a novel proactive DCA strategy is proposed for early detection of CCA by establishing correlations among distinct attack events through model-based reinforcement learning that utilizes abductive reasoning to conclude the attacker goal. The solution includes understanding the system model, learning the system dynamics, and correlating individual cyber-attacks to extract the attacker’s objective. The developed learning algorithm identifies the most probable attack path to reach the attacker’s objective by predicting the next attack steps. A DNP3-based cyber-physical co-simulation testbed is developed to test the proposed algorithm using the IEEE 13-node test feeder.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Active operator learning with predictive uncertainty quantification for partial differential equations

With the increased prevalence of neural operators being used to provide rapid solutions to partial differential equations (PDEs), understanding the accuracy of model predictions and the associated error levels is necessary for deploying reliable surrogate models in scientific applications. Existing uncertainty quantification (UQ) frameworks employ ensembles or Bayesian methods, which can incur substantial computational costs during both training and inference. Here, we propose a lightweight predictive UQ method tailored for Deep operator networks (DeepONets) that also generalizes to other operator networks. Numerical experiments on linear and nonlinear PDEs demonstrate that the framework’s uncertainty estimates are unbiased and provide accurate out-of-distribution uncertainty predictions with a sufficiently large training dataset. Our framework provides fast inference and uncertainty estimates that can efficiently drive outer-loop analyses that would be prohibitively expensive with conventional solvers. We demonstrate how predictive uncertainties can be used in the context of Bayesian optimization and active learning problems to yield improvements in accuracy and data-efficiency for outer-loop optimization procedures. In the active learning setup, we extend the framework to Fourier Neural Operators (FNO) and describe a generalized method for other operator networks. To enable real-time deployment, we introduce an inference strategy based on precomputed trunk outputs and a sparse placement matrix, reducing evaluation time by more than a factor of five. Our method provides a practical route to uncertainty-aware operator learning in time-sensitive settings.

97 MATHEMATICS AND COMPUTING↗

Multi-Timescale Optimal Operation Framework for Integrated Economic and Reliability Analysis of Hybrid Power Plants

This paper introduces a hierarchical modeling framework for hybrid power plants (HPP) to facilitate the operation of HPP in power systems similar to conventional generators (Congens) in the integrated multi-timescale optimal operation framework. To consider the uncertainties of HPP renewable power in the day-ahead scheduling, distributionally robust optimization (DRO) is used. To ensure that the state-of-charge (SOC) of energy storage systems in HPPs aligns closely with the planned value for long-term reliability, real-time SOC management is incorporated. In addition, an adjustable real-time control is designed for the robust delivery of HPP real-time services. Case studies performed on a revised IEEE 39-bus system demonstrate the effectiveness of the proposed framework for HPP operation. Simulation results highlight that the proposed framework not only can help operators schedule HPP similar to Congens in varying weather conditions but can also maintain the frequency reliability of the system.

frequency stability↗

Three-Dimensional Grid Visualization for Planning Activities: A Dubai Case Study

National Laboratory of the Rockies (NLR), in collaboration with the Dubai Electricity and Water Authority (DEWA) and Infra-X, has undertaken the Energy Visualization Analysis Project. The aim of this project is to enhance analytical and 3D visualization capabilities for distribution network planning and renewable energy integration. As modern grid continues to evolve with large-scale solar PV deployment and emerging distributed energy resources (DERs), the ability to effectively analyze, visualize, and communicate complex grid behaviors has become increasingly critical. The project focuses on developing empirical use cases based on real distribution feeder data and engineering workflows, ensuring the outcomes are directly aligned with operational environment. Through time-series power flow simulations and nodal hosting capacity analysis, the study quantifies the impacts of high PV penetration on voltage and thermal limits within representative 11 kV feeders. These analyses identify specific nodes and conditions where DER integration challenges arise. Furthermore, a Battery Energy Storage System (BESS) optimization algorithm was applied to determine the optimal size and placement of storage systems that can mitigate network constraints and enhance hosting capacity. The comparative results between base-case and BESS-augmented scenarios clearly demonstrate improvements in network stability and load management efficiency. In parallel, the NLR team developed an immersive 3D visualization framework, enabling interactive exploration of grid simulations using commodity head-mounted display (HMD) systems. This framework transforms conventional 2D simulation data into spatially intuitive visual environments - allowing engineers to analyze feeder conditions, PV hosting potential, and BESS effects in real time. This report represents the first foundational phase in establishing a visualization-driven analytical ecosystem. It provides a methodological foundation for data integration, visualization architecture, and simulation-based decision support, paving the way for large-scale adoption of immersive visualization across DEWA's Smart Grid Initiative, R&D activities, and future network resilience studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Novel Protection Scheme for Unbalanced Faults in Inverter Dominated Networks: A Computationally Efficient Algorithm for Entry-Level Relays

Microgrids are now a common practice in distribution systems to increase resilience and reliability. However, microgrid protection remains a critical challenge, considering its requirement to operate in both grid connected and islanded, and the variability in fault characteristics under each mode of operation. This paper presents unbalanced power (S unb ) based fault detection algorithm, which considers local voltage and current unbalances to determine faults in the system. S unb is a computationally efficient fault detection algorithm that is suitable for implementation in the programmable logic of entry level protective relays. In addition, the difference in current and voltage unbalance (D n ) is used to determine the fault type. The proposed method demonstrates high sensitivity and selectivity for line-to-ground (LG), line-to-line (LL), and double line-to-ground (LLG) faults, representing the most common faults in distribution systems. It also allows relay coordination with upstream and downstream protection devices in both island and grid connected operation, while preserving grading margins. The same pickup and time multiplier settings of a particular relay for both modes of operation eliminates the need for adaptive settings, which rely on communication networks. Validation was performed with a hardware-in-the-loop (HIL) setup using Typhoon HIL real time simulator interfaced with three entry-level, SEL 751 relays. Results confirmed the algorithm’s ability to discriminate fault conditions, and determine the fault type under both operating modes, maintain fast detection times, and ensure proper protection coordination.

fault classification↗

Multipoint Aerostructural Optimization of Wind Turbine Rotors Using a Coupled Blade‐Resolved Aerostructural Solver

Physics‐based design optimization workflows thread the needle between computational cost limitations and simulation complexity, often compromising between modeling detail and the range of operating design conditions. Multipoint aerostructural optimization of wind turbine rotors has so far been confined to low‐fidelity analyses or to high‐fidelity studies with simplified structural models, leaving the most complex design trade‐offs unexplored. We close this gap by performing the first tightly coupled gradient‐based multipoint aerostructural rotor optimization using 3D aerodynamic and structural solvers with discrete coupled adjoints. The optimizer simultaneously varies blade planform, airfoil shapes, and structural thickness through more than 270 design variables, minimizing a weighted combination of rotor mass and power across multiple wind speeds. Applied to a modified DTU 10‐MW benchmark under conservative structural and aerodynamic constraints, our multipoint optimization reduces rotor mass by up to 36% and increases power by 12%–15% across the main operating conditions; biasing the objective toward power yields power gains up to 18% and a 17% mass reduction. For a nominal wind distribution, 3‐point rotor designs accounting for low RPM and high thrust conditions capture dominant trade‐offs and outperform single‐point designs. Adding two off‐design points changes individual‐condition power by less than 3% but leaves the weighted average within 0.5%, and the mass‐power bias has a stronger effect on the final design than the operating‐point weighting itself. Our framework extends naturally to richer load cases and site‐specific wind distributions, providing a basis for high‐fidelity multipoint design earlier in industrial workflows.

17 WIND ENERGY↗

Dynamically Learning Incentives for Load Control

As electrical generation becomes more distributed and volatile, and loads become more uncertain, controllability of distributed energy resources (DERs), regardless of their ownership status, will be necessary for grid reliability. Grid operators lack direct control over end-users' grid interactions, such as energy usage, but incentives can influence behavior -- for example, an end-user that receives a grid-driven incentive may adjust their consumption or expose relevant control variables in response. A key challenge in studying such incentives is the lack of data about human behavior, which usually motivates strong assumptions, such as distributional assumptions on compliance or rational utility-maximization. In this paper, we propose a general incentive mechanism in the form of a constrained optimization problem -- our approach is distinguished from prior work by modeling human behavior (e.g., reactions to an incentive) as an arbitrary unknown function. We propose feedback-based optimization algorithms to solve this problem that each leverage different amounts of information and/or measurements. We show that each converges to an asymptotically stable incentive with (near)-optimality guarantees given mild assumptions on the problem. Finally, we evaluate our proposed techniques in voltage regulation simulations on standard test beds. We test a variety of settings, including those that break assumptions required for theoretical convergence (e.g., convexity, smoothness) to capture realistic settings. In this evaluation, our proposed algorithms are able to find near-optimal incentives even when the reaction to an incentive is modeled by a theoretically difficult (yet realistic) function.

demand response↗

Flexible operation of nuclear hybrid energy systems for load following and water desalination

Nuclear hybrid energy systems (NHES) have the potential to provide dependable and emission-free electricity to the grid while also increasing the flexibility and reliability of the electrical grid. Molten salt reactor (MSR) technology can provide consistent, carbon-free electricity while also increasing efficiency, security, and sustainability and reducing nuclear waste. This study investigates the integration of Molten Salt Reactors (MSR) and conventional Pressurized Water Reactors (PWR) with desalination technologies: Direct Contact Membrane Distillation (DCMD), Multi-Stage Flash Distillation (MSFD), and Reverse Osmosis (RO). Dynamic first-principles models were developed and tested using real grid data from the New York Independent System Operator. The results demonstrate that nuclear power is capable of flexibly responding to changing grid demand while simultaneously producing clean water, particularly during periods of low electricity demand. The MSR-RO system was found to be the most efficient in electricity generation and water production, and all hybrid systems reduced CO2 emissions by 356,000 to 682,000 tons annually. Economic analysis reveals that nuclear desalination technologies are cost-competitive with conventional systems, especially when paired with RO. Finally, these findings confirm the technical feasibility and environmental benefits of nuclear hybrid systems for sustainable electricity and water production.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power Supply Options for the Marpi Landfill, Saipan: Addendum to 2023 Feasibility Study

The Marpi Landfill (Marpi or the landfill), located on the northern end of the island of Saipan in the Commonwealth of the Northern Mariana Islands (CNMI), is powered by an on-site diesel generator that only operates when the landfill is open and staffed. The CNMI Office of Planning and Development (OPD) aspires to provide the Marpi Landfill with 24-hour power availability despite its remote location and to increase sustainable energy consumption within the CNMI. Pacific Northwest National Laboratory (PNNL) authored a feasibility study in 2023 that explores alternative power supply options for the landfill. This feasibility study (hereafter referred to as Phase I of this study) culminated in a report named “Power Supply Options for the Marpi Landfill, Saipan.” In Phase I, the project team investigated and prioritized seven different power supply scenarios (Table ES-1) for the landfill according to Solid Waste (SW) Taskforce priorities. The project team found that Scenario 4 (100 kW of solar photovoltaic [PV] generation, a 75 kW/300 kWh battery energy storage system [BESS], and 160 kW of diesel generation) ranked highest. Following the Phase I feasibility study, the SW Taskforce secured additional funding for PNNL to assess additional considerations regarding power supply options for Marpi. The purpose of Phase II of this study is to investigate these additional considerations, as compiled in this addendum. Some of the findings compiled here replace findings from the original report. The project team evaluated additional considerations regarding power supply options for the landfill, including modified operations to account for 24/7 power supply, electrified landfill equipment, new and replacement distribution line costs, and the social cost of carbon.

14 SOLAR ENERGY↗

Digitize O&M Procedure Guidelines for Illu Workflows (CRADA Final Report)

NREL will provide technical assistance to help digitize best practice operations and maintenance (“O&M”) procedure guidelines utilizing the Illu platform for specific distributed solar-storage system configurations. NREL shall test Illu workflows in a real inspection environment for clarity of instruction and ease of documentation.

14 SOLAR ENERGY↗

Model Quality and Measurement Density Impact on Volt/Volt Ampere Reactive Optimization Performance

The operation of the utility grid is being reshaped by the continuous addition of distributed energy resources and advanced metering infrastructure, which challenge existing grid control strategies. Some utilities deploy advanced distribution management systems (ADMS) to assist with the consolidation of various applications and to augment situational awareness in response to the new power delivery dynamics. An ADMS is an integrated software platform that provides utilities with a way to enhance their reliability, control, and optimization with advanced applications, such as volt/VAR optimization (VVO). A VVO application could serve as a vehicle to deliver cost savings by providing the utility with a method to reduce rates by controlling the voltage and decreasing the energy usage in their service territory. Some utilities are reluctant to integrate an ADMS, because it is a significant investment that requires approval from the public regulatory commission and/or their customers. This paper evaluates the impact on VVO performance when using a lower-quality network model supplemented with additional measurements, which could provide an implementation for cost savings. The results show that a better model quality would provide the highest energy savings; however, some level of telemetry is necessary in all scenarios to prevent voltage exceedances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantifying concentration distributions in redox flow batteries with neutron radiography

Abstract The continued advancement of electrochemical technologies requires an increasingly detailed understanding of the microscopic processes that control their performance, inspiring the development of new multi-modal diagnostic techniques. Here, we introduce a neutron imaging approach to enable the quantification of spatial and temporal variations in species concentrations within an operating redox flow cell. Specifically, we leverage the high attenuation of redox-active organic materials (high hydrogen content) and supporting electrolytes (boron-containing) in solution and perform subtractive neutron imaging of active species and supporting electrolyte. To resolve the concentration profiles across the electrodes, we employ an in-plane imaging configuration and correlate the concentration profiles to cell performance with polarization experiments under different operating conditions. Finally, we use time-of-flight neutron imaging to deconvolute concentrations of active species and supporting electrolyte during operation. Using this approach, we evaluate the influence of cell polarity, voltage bias and flow rate on the concentration distribution within the flow cell and correlate these with the macroscopic performance, thus obtaining an unprecedented level of insight into reactive mass transport. Ultimately, this diagnostic technique can be applied to a range of (electro)chemical technologies and may accelerate the development of new materials and reactor designs.

Science & Technology - Other Topics↗

Development and Validation of Two-Phase Flow Models in MOOSE for Molten Salt Reactor Application

Two-phase flow in Molten Salt Reactors (MSRs) is important as it impacts reactivity evolution, reactor transient response, and the removal of species dissolved in the molten salt through gas phase transfer. Therefore, accurately predicting the gas distribution and the associated liquid-gas interface area in MSRs is essential for their design and operation. Recently, we integrated two new models into Idaho National Laboratory (INL)’s Multiphysics Object-Oriented Simulation Environment (MOOSE): a multi-D generalization of a mixture drift-flux model and a Euler-Euler model. The Euler-Euler model offers higher fidelity, while the mixture drift-flux model provides greater computational efficiency, which is typically preferred for modeling reactor transients. However, the mixture model's accuracy in capturing void distribution and interfacial area in MSRs still needs to be assessed. This article begins with a description of the mathematical framework for the two-phase models implemented in MOOSE. It then presents validation of these models against relevant experimental data. Finally, both models are applied to the Molten Salt Reactor Experiment case study, analyzing various operational conditions such as different rates of fission product volatilization and diverse cover gas entrainment scenarios at the reactor pump. The article concludes by assessing the suitability of both models for capturing the two-phase flow dynamics critical to MSR operations.

42 - ENGINEERING↗

Development and Validation of Two-Phase Flow Models in MOOSE and Application to Molten Salt Reactors

Two-phase flow in Molten Salt Reactors (MSRs) is important as it impacts reactivity evolution, reactor transient response, and the removal of species dissolved in the molten salt through gas phase transfer. Therefore, accurately predicting the gas distribution and the associated liquid-gas interface area in MSRs is essential for their design and operation. Recently, we integrated two new models into Idaho National Laboratory (INL)’s Multiphysics Object-Oriented Simulation Environment (MOOSE): a multi-D generalization of a mixture drift-flux model and a Euler-Euler model. The Euler-Euler model offers higher fidelity, while the mixture drift-flux model provides greater computational efficiency, which is typically preferred for modeling reactor transients. However, the mixture model's accuracy in capturing void distribution and interfacial area in MSRs still needs to be assessed. This article begins with a description of the mathematical framework for the two-phase models implemented in MOOSE. It then presents validation of these models against relevant experimental data. Finally, both models are applied to the Molten Salt Reactor Experiment case study, analyzing various operational conditions such as different rates of fission product volatilization and diverse cover gas entrainment scenarios at the reactor pump. The article concludes by assessing the suitability of both models for capturing the two-phase flow dynamics critical to MSR operations.

42 - ENGINEERING↗