Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTRICAL CIRCUITS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

X-Ray-Diffraction Tests Of Irradiated Electronic Devices: II

Report describes research on use of x-ray diffraction to measure stresses in metal conductors of complementary metal oxide/semiconductor (CMOS) integrated circuits exposed to ionizing radiation. Expanding upon report summarized in "X-Ray-Diffraction Tests Of Irradiated Electronic Devices: I" (NPO-18803), presenting data further suggesting relationship between electrical performances of circuits and stresses and strains in metal conductors.

Shaw, David C.↗

Determination of lifetime and surface recombination velocity of p-n junction solar cells and diodes by observing transients

The unified view of transient methods for the determination of recombination lifetime tau and back surface recombination velocity S presented here for silicon solar cells and diodes attempts to define limitations of existing methods and to evolve improvements. The presence of sizable junction capacitance for silicon devices under forward voltage invalidates the use of conventional open-circuit voltage decay (OCVD) and reverse recovery. This led Green (1983) to his method of compensated open-circuit voltage decay, in which the addition of an external resistor shunting the solar cell partially corrects for the presence of the junction capacitance. Setting this resistance to zero produces an electrical short-circuit current-decay method, which has the advantage of enabling determination of both tau and S. In an alternate approach, one may insert the functional dependence of the junction capacitance on forward voltage. This new method, denoted by the acronym OCVDCAP, enables the determination of tau with apparently greater accuracy than that obtained by previous methods utilizing voltage transients. But OCVDCAP has in common with the previous methods that it determines tau only and has practical utility only for determining tau of long-base devices. This means that it is useful only for thick base regions. In principle, however, it has an advantage over short-circuit current decay: it requires only pressure contacts, not ohmic contacts, and therefore may be used to determine tau after key processing steps in manufacturing.

Lindholm, Fredrik A.↗

Noise and Electrical Characteristics below 10 K of small CHFET Circuits and Discrete Devices

This paper discusses the lates results of a continuing study of the properties of the complementary heterojunction field-effect transistor (CHFET) at 4K. The electrical characteristics, including the gate leakage current and the subthreshold transconductance, and the input-referred noise voltage for a new lot of discrete CHFETs is presented and discussed.

Complementary Heterojunction Field-effect Transist↗

Plasma contactors for electrodynamic tethers

Plasma contactors could be used to ground satellites to space plasma to acquire a flow of electrons to propel or power the satellites. A tether would cut across geomagnetic field lines, producing a potential difference between the ends of the tether. Closing the connection between the ends would form a circuit in which an electrical load could be inserted. Design constraints of the circuit are low impedance and a fully reversible high current. The contactor would generate a neutral plasma to connect to the ionospheric plasma. The surface area of the connection would have to be kept large enough for the current density to be equal to the random electron current density in the unperturbed space plasmas. The other contactor would feed electrons and draw ions from the space plasma. Experimental results from spaceborne and ground-based space plasma simulator tests of hollow cathodes that have shown that multiampere currents can be collected are described.

Patterson, Michael J.↗

Shuttle Electrical Power Analysis Program (SEPAP); single string circuit analysis report

An evaluation is reported of the data obtained from an analysis of the distribution network characteristics of the shuttle during a spacelab mission. A description of the approach utilized in the development of the computer program and data base is provided and conclusions are drawn from the analysis of the data. Data sheets are provided for information to support the detailed discussion on each computer run.

Murdock, C. R.↗

Reliability Effects of Surge Current Testing of Solid Tantalum Capacitors

Solid tantalum capacitors are widely used in space applications to filter low-frequency ripple currents in power supply circuits and stabilize DC voltages in the system. Tantalum capacitors manufactured per military specifications (MIL-PRF-55365) are established reliability components and have less than 0.001% of failures per 1000 hours (the failure rate is less than 10 FIT) for grades D or S, thus positioning these parts among electronic components with the highest reliability characteristics. Still, failures of tantalum capacitors do happen and when it occurs it might have catastrophic consequences for the system. This is due to a short-circuit failure mode, which might be damaging to a power supply, and also to the capability of tantalum capacitors with manganese cathodes to self-ignite when a failure occurs in low-impedance applications. During such a failure, a substantial amount of energy is released by exothermic reaction of the tantalum pellet with oxygen generated by the overheated manganese oxide cathode, resulting not only in destruction of the part, but also in damage of the board and surrounding components. A specific feature of tantalum capacitors, compared to ceramic parts, is a relatively large value of capacitance, which in contemporary low-size chip capacitors reaches dozens and hundreds of microfarads. This might result in so-called surge current or turn-on failures in the parts when the board is first powered up. Such a failure, which is considered as the most prevalent type of failures in tantalum capacitors [I], is due to fast changes of the voltage in the circuit, dV/dt, producing high surge current spikes, I(sub sp) = Cx(dV/dt), when current in the circuit is unrestricted. These spikes can reach hundreds of amperes and cause catastrophic failures in the system. The mechanism of surge current failures has not been understood completely yet, and different hypotheses were discussed in relevant literature. These include a sustained scintillation breakdown model [1-3]; electrical oscillations in circuits with a relatively high inductance [4-6]; local overheating of the cathode [5,7, 8]; mechanical damage to tantalum pentoxide dielectric caused by the impact of MnO2 crystals [2,9, 10]; or stress-induced-generation of electron traps caused by electromagnetic forces developed during current spikes [11]. A commonly accepted explanation of the surge current failures is that at unlimited current supply during surge current conditions, the self-healing mechanism in tantalum capacitors does not work, and what would be a minor scintillation spike if the current were limited, becomes a catastrophic failure of the part [l, 12]. However, our data show that the scintillation breakdown voltages are significantly greater that the surge current breakdown voltages, so it is still not clear why the part, which has no scintillations, would fail at the same voltage during surge current testing (SCT).

Teverovsky, Alexander↗

Electrical-Impedance-Based Ice-Thickness Gauges

Langley Research Center has developed electrical-impedance-based ice-thickness gauges and is seeking partners and collaborators to commercialize them. When used as parts of active monitoring and diagnostic systems, these gauges make it possible to begin deicing or to take other protective measures before ice accretes to dangerous levels. These gauges are inexpensive, small, and simple to produce. They can be adapted to use on a variety of stationary and moving structures that are subject to accumulation of ice. Examples of such structures include aircraft, cars, trucks, ships, buildings, towers, power lines (see figure), power-generating equipment, water pipes, freezer compartments, and cooling coils. A gauge of this type includes a temperature sensor and two or more pairs of electrically insulated conductors embedded in a surface on which ice could accumulate. The electrical impedances of the pairs of conductors vary with the thickness of any ice that may be present. Somewhat more specifically, when the pairs of conductors are spaced appropriately, the ratio between their impedances is indicative of the thickness of the ice. Therefore, the gauge includes embedded electronic circuits that measure the electrical impedances, plus circuits that process the combination of temperature and impedance measurements to determine whether ice is present and, if so, how thick it is. Of course, in the processing of the impedance measurements, the temperature measurements help the circuitry to distinguish between liquid water and ice. The basic design of a gauge of this type can be adapted to local conditions. For example, if there is a need to monitor ice over a wide range of thickness, then the gauge can include more than two sets of conductors having various spacings.

Weinstein, Leonard↗

Overvoltage protection network

Electrical equipment to be protected from overvoltage is connected with a possible source of overvoltage via an input conductor. A fuse is connected in series with the input conductor. A spark gap is connected between the input conductor and ground for conducting the overvoltage current to ground and for blowing the fuse to open the circuit to the electrical equipment. A pulse attenuator network is provided between the spark gap and the electrical equipment to be protected for attenuating the pulse of energy passing through the fuse and spark gap prior to blowing of the fuse. The pulse attenuator network includes additional shunt spark gaps, series inductance, and a series connection of a twisted shielded pair of conductors having low-voltage insulation.

Cambra, J. M.↗

Television camera video level control system

A video level control system is provided which generates a normalized video signal for a camera processing circuit. The video level control system includes a lens iris which provides a controlled light signal to a camera tube. The camera tube converts the light signal provided by the lens iris into electrical signals. A feedback circuit in response to the electrical signals generated by the camera tube, provides feedback signals to the lens iris and the camera tube. This assures that a normalized video signal is provided in a first illumination range. An automatic gain control loop, which is also responsive to the electrical signals generated by the camera tube 4, operates in tandem with the feedback circuit. This assures that the normalized video signal is maintained in a second illumination range.

Kravitz, M.↗

"Printed-circuit" rectenna

Rectifying antenna is less bulky structure for absorbing transmitted microwave power and converting it into electrical current. Printed-circuit approach, using microstrip technology and circularly polarized antenna, makes polarization orientation unimportant and allows much smaller arrays for given performance. Innovation is particularly useful with proposed electric vehicles powered by beam microwaves.

Dickinson, R. M.↗

Computer-Aided Engineering Of Cabling

Program generates data sheets, drawings, and other information on electrical connections. DFACS program, centered around single data base, has built-in menus providing easy input of, and access to, data for all personnel involved in system, subsystem, and cabling. Enables parallel design of circuit-data sheets and drawings of harnesses. Also recombines raw information to generate automatically various project documents and drawings, including index of circuit-data sheets, list of electrical-interface circuits, lists of assemblies and equipment, cabling trees, and drawings of cabling electrical interfaces and harnesses. Purpose of program to provide engineering community with centralized data base for putting in, and gaining access to, functional definition of system as specified in terms of details of pin connections of end circuits of subsystems and instruments and data on harnessing. Primary objective to provide instantaneous single point of interchange of information, thus avoiding

Billitti, Joseph W.↗

Circuit for Monitoring Cell Voltages

Circuit monitors voltage of each cell in electrical battery within few millivolts. Circuit includes two bipolar analog multiplexers: repeatedly sample outputs of 12 1.5 volt cells. Terminals of multiplexer 1 connected to positive sides of cells and terminals of multiplexer 2 connected to negative sides. Outputs of multiplexers connected to differential operational amplifier: provides signals for recording and display.

Lepisto, J. W.↗

Fault Detection, Isolation and Recovery (FDIR) Portable Liquid Oxygen Hardware Demonstrator

The Fault Detection, Isolation and Recovery (FDIR) hardware demonstration will highlight the effort being conducted by Constellation's Ground Operations (GO) to provide the Launch Control System (LCS) with system-level health management during vehicle processing and countdown activities. A proof-of-concept demonstration of the FDIR prototype established the capability of the software to provide real-time fault detection and isolation using generated Liquid Hydrogen data. The FDIR portable testbed unit (presented here) aims to enhance FDIR by providing a dynamic simulation of Constellation subsystems that feed the FDIR software live data based on Liquid Oxygen system properties. The LO2 cryogenic ground system has key properties that are analogous to the properties of an electronic circuit. The LO2 system is modeled using electrical components and an equivalent circuit is designed on a printed circuit board to simulate the live data. The portable testbed is also be equipped with data acquisition and communication hardware to relay the measurements to the FDIR application running on a PC. This portable testbed is an ideal capability to perform FDIR software testing, troubleshooting, training among others.

Oostdyk, Rebecca L.↗

Power Electronics Being Developed for Deep Space Cryogenic Applications

Electronic circuits and systems designed for deep space missions need to operate reliably and efficiently in harsh environments that include very low temperatures. Spacecraft that operate in such cold environments carry a large number of heaters so that the ambient temperature for the onboard electronics remains near 20 C. Electronics that can operate at cryogenic temperatures will simplify system design and reduce system size and weight by eliminating the heaters and their associated structures. As a result, system development and launch cost will be reduced. At the NASA Glenn Research Center, an ongoing program is focusing on the development of power electronics geared for deep space low-temperature environments. The research and development efforts include electrical components design, circuit design and construction, and system integration and demonstration at cryogenic temperatures. Investigations are being carried out on circuits and systems that are targeted for use in NASA missions where low temperatures will be encountered: devices such as ceramic and tantalum capacitors, metal film resistors, semiconductor switches, magnetics, and integrated circuits including dc/dc converters, operational amplifiers, voltage references, and motor controllers. Test activities cover a wide range of device and circuit performance under simple as well as complex test conditions, such as multistress and thermal cycling. The effect of low-temperature conditions on the switching characteristics of an advanced silicon-on-insulator field effect transistor is shown. For gate voltages (VGS) below 2.6 V, drain currents at -190 C are lower than drain currents at room temperature (20 C).

Patterson, Richard L.↗

Electronic filters, hearing aids and methods

An electronic filter for an electroacoustic system. The system has a microphone for generating an electrical output from external sounds and an electrically driven transducer for emitting sound. Some of the sound emitted by the transducer returns to the microphone means to add a feedback contribution to its electrical output. The electronic filter includes a first circuit for electronic processing of the electrical output of the microphone to produce a first signal. An adaptive filter, interconnected with the first circuit, performs electronic processing of the first signal to produce an adaptive output to the first circuit to substantially offset the feedback contribution in the electrical output of the microphone, and the adaptive filter includes means for adapting only in response to polarities of signals supplied to and from the first circuit. Other electronic filters for hearing aids, public address systems and other electroacoustic systems, as well as such systems and methods of operating them are also disclosed.

Engebretson, A. Maynard↗

Lightning protection practices applied to field station installations

Theoretical considerations of lightning phenomena and the effects of the magnetic, capacitive, and resistive components of lightning-induced voltages are discussed. A typical tracking station is analyzed from a lightning standpoint. Specific protective methods are discussed, including the implementation of high-surge-current voltage clippers for sensitive electrical and electronic circuits, grounding, counterpoises, and bonding. The safety of operating personnel is also treated as a prime consideration.

Blalock, T. J.↗