Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy Conservation Measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Adjustments to the law of the wall above an Amazon forest explained by a spectral link

Modification to the law of the wall represented by a dimensionless correction function ϕ RSL (z/h) is derived using atmospheric turbulence measurements collected at two sites in the Amazon in near-neutral stratification, where z is the distance from the forest floor and h is the mean canopy height. The sites are the Amazon Tall Tower Observatory for z/h∈ [1,2.3] and the Green Ocean Amazon (GoAmazon) site for z/h∈ [1,1.4]. Here, a link between the vertical velocity spectrum E ww (k) (k is the longitudinal wavenumber) and ϕ RSL is then established using a co-spectral budget (CSB) model interpreted by the moving-equilibrium hypothesis. The key finding is that ϕ RSL is determined by the ratio of two turbulent viscosities and is given as ν t,BL /ν t,RSL, where ν t,RSL = (1/A)∫$^{∞}_{0}$ τ(k)E ww (k)dk, ν t,BL = k v (z−d)u * , τ(k) is a scale-dependent decorrelation time scale between velocity components, A = C R /(1−C I ) = 4.5 is predicted from the Rotta constant C R = 1.8, and the isotropization of production constant C I = 3/5 given by rapid distortion theory, k v is the von Kármán constant, u * is the friction velocity at the canopy top, and d is the zero-plane displacement. Because the transfer of energy across scales is conserved in E ww (k) and is determined by the turbulent kinetic energy dissipation rate (ε), the CSB model also predicts that ϕ RSL scales with L BL /L d , where L BL is the length scale of attached eddies to z = d, and L d = u$_{*}^{3}$/ε is a macro-scale dissipation length.

54 ENVIRONMENTAL SCIENCES↗

Klickitat Valley Health Central Utility Plant Modernization

This project replaced legacy heating and cooling equipment at Klickitat Valley Health (KVH), a rural hospital in Goldendale, Washington. Work included constructing a new chiller building, installing modern hydronic piping systems, replacing the main Emergency Department air handler (Air Handlining Unit (AHU-1)), upgrading electrical systems, and converting the Emergency Department wing from electric reheat to hydronic heating and cooling. Commissioning, testing, adjusting, and balancing were completed under this grant. These upgrades improve energy efficiency, operational resilience, and system reliability while preparing the campus for future electrification and renewable energy integration. They also support growth in healthcare services for a rural population. The project directly reduces energy costs and provides a foundation for future decarbonization measures, including a FEMA-funded microgrid and a large-scale ground source heat pump (GSHP) project. These follow-on initiatives would not have been possible without the hydronic backbone built through this project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Siamese CNN + KNN-Based Classification Framework for Non-intrusive Load Monitoring

Through the development of smart grids, programs such as demand side response, have been presented as auxiliary services to the real-time operation of distributed networks. In order to provide consumers information on their energy consumption, so that a modulation in consumption is possible, non-intrusive load monitoring has been introduced as an solution to this pattern recognition problem. Non-intrusive load monitoring enables the modeling of electrical loads connected to the low-voltage system, considering only a single measurement point. Presented state-of-the-art solutions though, consider availability of data as well as representation of all possible classes of the environment. This is of course a most conservative hypothesis, since in real-life applications availability of such data is much difficult, as well as the dynamic behavior of models is implicitly evolving in time. Here, a framework that uses neural Siamese networks with k-nearest neighbor clustering is presented toward non-intrusive load monitoring. Online learning feature is implemented, which relaxes the hypothesis of data requirements as well addresses the evolving nature of load profile. k-nearest clustering allows nonlinear characteristic space modelling. Test results using synthetics and real-life data show that the solution, besides obtaining a good generalizability in the classification, also obtained results with an accuracy of 95.77%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Spinodal enhancement of fluctuations in nucleus-nucleus collisions

Subensemble Acceptance Method (SAM) [1, 2] is an essential link between measured event-by-event fluctuations and their grand canonical theoretical predictions such as lattice QCD. The method allows quantifying the global conservation law effects in fluctuations. In its basic formulation, SAM requires a sufficiently large system such as created in central nucleus-nucleus collisions and sufficient space-momentum correlations. Directly in the spinodal region of the First Order Phase Transition (FOPT) different approximations should be used that account for finite size effects. Thus, we present the generalization of SAM applicable in both the pure phases, metastable and unstable regions of the phase diagram [3]. Obtained analytic formulas indicate the enhancement of fluctuations due to crossing the spinodal region of FOPT and are tested using molecular dynamics simulations. A rather good agreement is observed. Using transport model calculations with interaction potential we show that the spinodal enhancement of fluctuations survives till the later stages of collision via the memory effect [4]. However, at low collision energies the space-momentum correlation is not strong enough for this signal to be transferred to second and third order cumulants measured in momentum subspace. This result agrees well with recent HADES data on proton number fluctuations at $\sqrt{S_{NN}}$ = 2.4 GeV which are found to be consistent with the binomial momentum space acceptance [5].

Poberezhnyuk, Roman↗

Valuing Residential Energy Efficiency: Analysis for a Prototypical Southeastern Utility [Slides]

The increasing amount of variable renewable energy resources and shifts towards more end-use and vehicle electrification suggests profound changes to power system planning and operation. Specifically, renewable energy is expected to shift net peak demand from late afternoon to early evening and end-use electrification may significantly increase winter peak demand. Residential energy efficiency is likely to align well with these shifts as it tends to produce savings in the early evening (e.g., from lighting measures) and coincident with heating loads (e.g., from envelope and space conditioning measures). Despite the opportunity to decrease system costs and emissions, residential energy efficiency is often limited by static valuation methods and its economic potential is considerably less than its technical potential. Using hourly residential energy efficiency characterizations, utility program cost data, and a capacity expansion model, we estimate the benefits of residential energy efficiency for a prototypical, summer-peaking utility in the Southeastern region. We first establish the cost-effective residential energy efficiency portfolio through “competition” with supply-side resources in a forward-looking capacity expansion model. Importantly, we then evaluate several scenarios intended to drive an increasing amount of cost-effective residential energy efficiency through measure cost reductions, increased customer adoption, policy goals (e.g., carbon price), and delivery of an integrated package of measures. The results quantify total system cost and emissions reductions, fossil-fuel plant retirements, and peak demand reductions. Results suggest the design and prioritization of policies and programs to access the untapped amount of cost-effective residential energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nonlinear dynamic analysis of solution multiplicity of buoyancy ventilation in a typical underground structure

Buoyancy ventilation is widely used in underground buildings, such as underground hydropower stations. Multiple solutions of buoyancy ventilation may exist in those underground structures. In this study, we developed a transient model comprising an ordinary differential equation system to describe buoyancy ventilation patterns in typical two-zone underground structures. Additionally, the accuracy of the model was validated. Nonlinear dynamical analysis was conducted to study multiple steady-state airflow. According to mathematical derivation, the configuration of one local heat source at the bottom corner introduces two stable solutions. The criterion to determine the stability and existence of solutions for more general scenarios was developed. Using this criterion, we obtained the multiple steady states of any two-zone underground buildings for different stack height ratios and the strength ratios of the heat sources. Furthermore, this criterion can be adopted for the design of buoyancy ventilation or natural smoke ventilation systems. Designers can change the height ratio of the stack or the heat ratio of two zones to induce the desired ventilation patterns. Finally, a case study was conducted with field measurements to demonstrate the use of the nonlinear dynamical analysis method to investigate the multiple steady states of buoyancy ventilation. Through the case study, we validated that the proposed criterion could produce the same result as the nonlinear dynamical analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Advanced Air Sealing, Attic Floor Insulation, Duct Sealing and Insulation, and Drill-and-Fill Wall Insulation

This report is part of a series describing different ResStock measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Advanced Air Sealing, Attic Floor Insulation, Duct Sealing and Insulation, and Drill-and-Fill Wall Insulation" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Plasma Dynamics in Low-Electron-Beta Environments

Recent in situ measurements by the MMS and Parker Solar Probe missions bring interest to small-scale plasma dynamics (waves, turbulence, magnetic reconnection) in regions where the electron thermal energy is smaller than the magnetic one. Examples of such regions are the Earth’s magnetosheath and the vicinity of the solar corona, and they are also encountered in other astrophysical systems. In this brief review, we consider simple physical models describing plasma dynamics in such low-electron-beta regimes, discuss their conservation laws and their limits of applicability.

79 ASTRONOMY AND ASTROPHYSICS↗

Spark Channel Dynamics of Electrostatic Discharges

When two differently-charged objects are brought in close proximity to each other, the resulting high electric fields can cause electron avalanche breakdown of the air gap separating the objects, a process known as electrostatic discharge (ESD). If enough initial charge is stored on the objects, the electrical breakdown can proceed to ionize the air to such a degree that a highly conductive filament of plasma forms in the gap, known as a spark channel. The spark electrically bridges the air gap, resulting in a rapid pulse of current that neutralizes the charge difference. The current pulse produces significant heating of the gas in the spark, resulting in dissociation, ionization, thermal radiation, and hydrodynamic expansion. ESD presents a hazard to electrically-sensitive devices, with consequences such as economic losses (e.g. damaged electronics) or unsafe response (e.g. unintended ignition of flammable gas mixtures, initiation of detonators, etc.). For this thesis, the ESD spark is taken to occur between two conducting electrodes, with the spark channel being axisymmetric in a cylindrical coordinate system centered on the channel. An RLC-type circuit is used for the discharge model of the ESD event. The spark is treated as a time-dependent resistance that is in series with a capacitance, an inductance, and (optionally) a load resistance representing a “victim” component under threat from the ESD event. The primary motivation of this work is to use a numerical hydrodynamic model to understand the energy dissipation and transport processes in the spark. The model consists of the compressible Euler equations of mass, momentum, and energy conservation together with an Eddington/P1 approximation for thermal radiation transport. To close the hydrodynamic system, an equation of state (EOS) was fitted from tabular data for air that accounts for the dissociation and ionization of air species. The hydrodynamic equations are solved using a conservative Lagrangian finite volume method. These partial differential equations are coupled to the circuit equations by calculation of the spark resistance via numerical integration of the electrical conductivity of the channel. Computational results are compared against experimental measurements of discharge current and radial density of the spark channel.

42 ENGINEERING↗

Modelica-based modeling and simulation of district cooling systems: A case study

While equation-based object-oriented modeling language Modelica can evaluate practical energy improvements for district cooling systems, few have adopted Modelica for this type of large-scale thermo-fluid system. Further, to our best knowledge, district cooling modeling studies have yet to include hydraulics in piping networks alongside plant models featuring realistic mechanical systems and controls. These are critical details to include when looking to make energy and control improvements in many physical system installations. To fill these gaps, this study released new open-source district cooling models at the Modelica Buildings Library and leveraged these models for a real-world case study at the University of Colorado Boulder. Here, the site includes six buildings connected to a central chiller plant featuring a waterside economizer. Several energy saving strategies are pursued based on the validated model, including control setpoint optimization, equipment modification, and pump setpoint adjustments. Results indicate that a combination of the studied measures can save the campus annually 84.6 MWh of energy, 8.9% of electricity costs, 58.0 metric tons of carbon dioxide emissions, while the waterside economizer cuts down chillers’ run times by 201 days/year, reducing maintenance costs and extending chiller life.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Exploring the QCD phase diagram through correlations and fluctuations

The exploration of the Quantum Chromodynamics (QCD) phase diagram is a central goal of relativistic heavy-ion collision experiments. This review focuses on the role of fluctuations and correlations as sensitive probes of the phase structure. We discuss theoretical advancements and experimental methodologies employed to map the QCD phase diagram, highlighting constraints derived from both lattice QCD calculations and existing experimental data. Key observables such as cumulants and factorial cumulants of conserved charges (e.g., net-proton, net-charge) are explored as promising signatures of phase transitions and the QCD critical point. We discuss how these quantities are measured experimentally and compared with theoretical predictions, addressing challenges and best practices for meaningful comparisons. Special attention is given to predictions and current experimental results at high baryon density, including recent findings from the STAR collaboration at RHIC. Finally, we identify open issues and future directions for fluctuation and correlation studies at lower collision energies, relevant for future measurements, for example by the CBM experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ComStock Reference Documentation (V.1)

The commercial building sector stock model, or ComStock™, is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. ComStock asks and answers two questions: how is energy used in the U.S. building stock and what are the impact of energy saving technologies. Specifically, ComStock identifies where energy is being consumed geographically, in what building types and end uses, and at what times of day. Simultaneously, it identifies the impact of efficiency measures: how much energy do efficiency measures save; where, or in what use cases do measures save energy; when, or at what time of day do savings occur; and which building stock segments have the biggest savings potential. This document contains the methodology and assumptions behind ComStock and serves as a guide to its use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

South Africa: Energy Efficiency Demand Side Management Experience (2004-2022)

In July 2022, President Cyril Ramaphosa announced an emergency response plan to address the growing electricity crisis in South Africa, which included the necessity for customers of Eskom, South Africa’s primary electricity supplier, to implement demand-side energy efficiency measures. This report is the first of two reports that provides the foundation for a strategic Demand-Side Management (DSM) approach to reduce load shedding and maximize energy savings in South Africa, through inter-governmental collaboration and increased coordination of energy efficiency activities. This first report focuses on the experience of Eskom’s rate-funded Integrated Demand Management (IDM) programme, from its beginning in 2004 to today, highlighting the factors that led to failed support for the programme, and emphasizing the measures that will need to be addressed to meet the government’s energy efficiency (EE) goals, as well as other socio-economic and environmental priorities, such as job creation, affordability and greenhouse gas (GHG) emission reduction goals.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

2004 Kansas City Regional Household Travel Survey

The 2004 Regional Household Travel Survey documented the travel behavior characteristics of Kansas City residents to update the area's transportation model. The Mid-America Regional Council and the Kansas and Missouri Departments of Transportation sponsored the survey, which was administered by NuStats. Activity and travel information was collected for all household members, regardless of age, during a specific 24-hour period. It relied on the willingness of households to provide demographic information about its members and vehicles and to have all household members record all travel and activity for a specific 24-hour period. The study also included a subsample of household vehicles with global positioning system (GPS) devices. The objectives of the GPS component were twofold: (1) to provide an independent data stream of vehicular travel in order to measure the accuracy of the travel data reported over the telephone, and (2) to obtain details about those trips that were captured by GPS but not reported over the telephone, in order to derive a trip-correction factor.

1Hz data↗

ResStock Measure Documentation: HVAC Load Flexibility

This report is part of a series describing different ResStock(TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "HVAC Load Flexibility" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Air Conditioning Systems Fault Detection and Diagnosis-Based Sensing and Data-Driven Approaches

The air conditioning (AC) system is the primary building end-use contributor to the peak demand for energy. The energy consumed by this system has grown as fast as it has in the last few decades, not only in the residential section but also in the industry and transport sectors. Therefore, to combat energy crises, urgent actions on energy efficiency should be taken to support energy security. Consequently, the faults in AC system components increase energy consumption due to the degradation of the system’s performance and the losses in the energy conversion procedure. In this work, AC system fault detection and diagnosis (FDD) methods are investigated to propose analytic tools to identify faults and provide solutions to those problems. The analysis of existing work shows that data-driven approaches are more accurate for both soft and hard fault detection and diagnosis in AC systems. Therefore, the proposed methods are not accurate for simultaneous fault detection, while in some works, authors tested the method with several faults separately without investigating scenarios that combine more than one fault. Moreover, this study shows that integrating data-driven approaches requires deploying an optimal sensing and measurement architecture that can detect a maximum number of faults with minimally deployed sensors. The new sensing, information, and communication technologies are discussed for their integration in AC system monitoring in order to optimize system operation and detect faults.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High salinity seawater boiling point elevation: Experimental verification

Boiling point elevation (BPE) for high salinity solutions is a crucial parameter that significantly affects the overall thermal efficiency of desalination, water treatment, and many other industrial processing systems, especially when minimum or zero liquid discharge is a key requirement. This paper addresses the discrepancies among the empirical correlations reported in the literature that were commonly used to determine BPE for seawater solutions. An evaluation of the experimental data with low solution concentration reveals that the data cannot be extrapolated to determine the BPE at high concentration (X > 140 ppt or g/kg). Besides, disparities are established within different equations used to determine the BPE for high salinity seawater. As a result of the minimal availability of experimental data of BPE for X > 140 ppt and the need to eliminate the discrepancies, an experimental setup was built, which can produce reliable and repeatable BPE data for any solution concentration. Boiling points were obtained experimentally for seawater solutions with a wide range of salinity (X between 20 and 280 ppt) and brine solution temperature (t b between 20 and 80°C). The experimental results of boiling point elevations for seawater are further compared with the experimental data and analytical results reported in the literature. The newly obtained experimental results show that the minimum and maximum BPE values for the brine solutions tested are 0.175°C at t b = 80°C and X = 20 ppt, and 11.6°C at t b = 80°C and X = 280 ppt, respectively. Furthermore, the measured BPE data for seawater concentration over 80 ppt are fitted and presented using an appropriate fitting model. The new correlation can accurately predict the BPE for high salinity seawater brines and thus should be very helpful in the design of high-energy-efficient evaporation systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗