Search NASA⌕ Search

SEARCH · Search NASA

Results for “Exercise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Augmented baroreflex heart rate gain after moderate-intensity, dynamic exercise

The occurrence of a sustained vasodilation and hypotension after acute, dynamic exercise suggests that exercise may alter arterial baroreflex mechanisms. Therefore, we assessed systemic hemodynamics, baroreflex regulation of heart rate, and cardiac vagal tone after 60 min of cycling at 60% peak oxygen consumption in 12 healthy, untrained men and women (ages 21-28 yr). We derived sigmoidal carotid-cardiac baroreflex relations by measurement of R-R interval changes induced by ramped, stepwise, R-wave-triggered changes in external neck pressure from 40 to -65 mmHg. We estimated tonic cardiac vagal control with power spectral analysis of R-R interval variability in the respiratory frequency band (0.2-0.3 Hz) during frequency- and tidal volume-controlled breathing. Both mean arterial pressure and total peripheral resistance were reduced postexercise [pressure: from 86 +/- 2 (mean +/- SE) to 81 +/- 2 mmHg; resistance: from 23 +/- 2 to 16 +/- 1 units; both P < 0.05]. Cardiac output was increased postexercise (from 3.9 +/- 0.3 to 5.5 +/- 0.5 l/min, P < 0.05). Both slope and range of the carotid-cardiac baroreflex relation were increased postexercise (slope: from 4.7 +/- 0.7 to 6.1 +/- 0.9 ms/mmHg; range: from 186 +/- 23 to 238 +/- 30 ms, P < 0.05). Respiratory R-R interval variability (cardiac vagal tone) was not changed at any time after exercise, whereas heart rate and plasma norepinephrine levels were elevated. Thus moderate-intensity, dynamic exercise increases heart rate and cardiac output, reduces peripheral vascular resistance, and augments baroreflex responsiveness. Our data suggest that augmented baroreflex heart rate gain restrains rather than contributes to postexercise hypotension, which appears to be mediated predominately by vasodilation.

NASA Discipline Cardiopulmonary↗

Exercise thermoregulation after 6 h of chair rest, 6 degrees head-down bed-rest, and water immersion deconditioning in men

The purpose was to investigate the mechanism for the excessive exercise hyperthermia following deconditioning (reduction of physical fitness). Rectal (Tre) and mean skin (Tsk) temperatures and thermoregulatory responses were measured in six men [mean (SD) age, 32 (6) years; mass, 78.26 (5.80) kg; surface area, 1.95 (0.11) m2; maximum oxygen uptake (VO2max), 48 (6) ml.min-1.kg-1; whilst supine in air at dry bulb temperature 23.2 (0.6) degree C, relative humidity 31.1 (11.1)% and air speed 5.6 (0.1) m.min-1] during 70 min of leg cycle exercise [51 (4)% VO2max] in ambulatory control (AC), or following 6 h of chair rest (CR), 6 degree head-down bed rest (BR), and 20 degree (WI20) and 80 degree (WI80) foot-down water immersion [water temperature, 35.0 (0.1) degree C]. Compared with the AC exercise delta Tre [mean (SD) 0.77 (0.13) degree C (*P < 0.05), after WI80 0.96 (0.13) degree C*, and after WI20 1.03 (0.09) degree C*. All Tsk responded similarly to exercise: they decreased (NS) by 0.5-0.7 degree C in minutes 4-8 and equilibrated at +0.1 to +0.5 degree C at 60-70. Skin heat conductance was not different among the five conditions (range = 147-159 kJ.m-2.h-1.degree C-1). Results from an intercorrelation matrix suggested that total body sweat rate was more closely related to Tre at 70 min (Tre70) than limb sweat rate or blood flow. Only 36% of the variability in Tre70 could be accounted for by total sweating, and less than 10% from total body dehydration. It would appear that multiple factors are involved which may include change in sensitivity of thermo- and osmoreceptors.

NASA Discipline Regulatory Physiology↗

cAMP levels in fast- and slow-twitch skeletal muscle after an acute bout of aerobic exercise

The present study examined whether exercise duration was associated with elevated and/or sustained elevations of postexercise adenosine 3',5'-cyclic monophosphate (cAMP) by measuring cAMP levels in skeletal muscle for up to 4 h after acute exercise bouts of durations that are known to either produce (60 min) or not produce (10 min) mitochondrial proliferation after chronic training. Treadmill-acclimatized, but untrained, rats were run at 22 m/min for 0 (control), 10, or 60 min and were killed at various postexercise (0, 0.5, 1, 2, and 4 h) time points. Fast-twitch white and red (quadriceps) and slow-twitch (soleus) muscles were quickly excised, frozen in liquid nitrogen, and assayed for cAMP with a commercial kit. Unexpectedly, cAMP contents in all three muscles were similar to control (nonexercise) at most (21 of 30) time points after a single 10- or 60-min run. Values at 9 of 30 time points were significantly different from control (P < 0.05); i.e., 3 time points were significantly higher than control and 6 were significantly less than control. These data suggest that the cAMP concentration of untrained skeletal muscle after a single bout of endurance-type exercise is not, by itself, associated with exercise duration.

NASA Discipline Musculoskeletal↗

Effect of physical exercise prelabyrinthectomy on locomotor balance compensation in the squirrel monkey

This study examines the effectiveness of physical exercise, during a prepathology state, on locomotor balance compensation after subsequent unilateral labyrinthectomy in squirrel monkeys. An experimental group underwent 3 hr. of daily running exercise on a treadmill for 3 mo. prior to the surgery, whereas a control group was not exercised. Postoperatively, the locomotor balance function of both groups was tested for 3 mo. There was no significant difference in gait deviation counts in the acute phase of compensation. However, in the chronic compensation maintenance phase, the number of gait deviation counts was fewer in the exercise group, which showed significantly better performance stability.

Non-NASA Center↗

Mechanism Development, Testing, and Lessons Learned for the Advanced Resistive Exercise Device

The Advanced Resistive Exercise Device (ARED) has been developed at NASA Johnson Space Center, for the International Space Station (ISS) program. ARED is a multi-exercise, high-load resistive exercise device, designed for long duration, human space missions. ARED will enable astronauts to effectively maintain their muscle strength and bone mass in the micro-gravity environment more effectively than any other existing devices. ARED's resistance is provided via two, 20.3 cm (8 in) diameter vacuum cylinders, which provide a nearly constant resistance source. ARED also has a means to simulate the inertia that is felt during a 1-G exercise routine via the flywheel subassembly, which is directly tied to the motion of the ARED cylinders. ARED is scheduled to fly on flight ULF 2 to the ISS and will be located in Node 1. Presently, ARED is in the middle of its qualification and acceptance test program. An extensive testing program and engineering evaluation has increased the reliability of ARED by bringing potential design issues to light before flight production. Some of those design issues, resolutions, and design details will be discussed in this paper.

Lamoreaux, Christopher D.↗

Determining Exercise Strength Requirements for Astronaut Critical Mission Tasks: Reaching Under G-Load

The critical mission tasks assessments effort seeks to determine the physical performance requirements that astronauts must meet in order to safely and successfully accomplish lunar exploration missions. These assessments will determine astronaut preflight strength, fitness, and flexibility requirements, and the extent to which exercise and other countermeasures must prevent the physical deconditioning associated with prolonged weightlessness. The purpose is to determine the flexibility and strength that crewmembers must possess in order to reach Crew Exploration Vehicle controls during maneuvers that result in sustained acceleration levels ranging from 3.7G to 7.8G. An industry standard multibody dynamics application was used to create human models representing a 5th percentile female, a 50th percentile male, and a 95th percentile male. The additional mass of a space suit sleeve was added to the reaching arm to account for the influence of the suit mass on the reaching effort. The human model was merged with computer models of a pilot seat and control panel for the Crew Exploration Vehicle. Three dimensional paths were created that guided the human models hand from a starting position alongside its thigh to three control targets: a joystick, a keyboard, and an overhead switch panel. The reaching motion to each target was repeated under four vehicle acceleration conditions: nominal ascent (3.7G), two ascent aborts (5.5G and 7.8G) and lunar reentry (4.6G). Elbow and shoulder joint angular excursions were analyzed to assess range of motion requirements. Mean and peak elbow and shoulder joint torques were determined and converted to equivalent resistive exercise loads to assess strength requirements. Angular excursions for the 50th and 95th percentile male models remained within joint range of motion limits. For the 5th percentile female, both the elbow and the shoulder exceeded range of motion limits during the overhead reach. Elbow joint torques ranged from 10 N-m (nominal ascent) to 60 N-m (ascent abort). Shoulder joint torques ranged from 65 N-m (nominal ascent) to 280 N-m (ascent abort). Maximal equivalent exercise loads reached 30 lb in tricep extension, 9 lb in bicep curl, 110 lb in unilateral pullover and unilateral bench press for nominal conditions (lunar reentry), and 188 lb in unilateral pullover and unilateral bench press. The location of the pilot seat was found to be inadequately located to allow a 5th percentile female to reach the switches on the overhead panel. Elbow strength requirements were found to be well within population norms. Shoulder strength was found to be a limiting factor. Reaching under nominal ascent and lunar reentry conditions was found to require near maximal shoulder strength. Reaching under ascent abort conditions requires shoulder strength well beyond population norms. Pilot seats must adjust to accomodate a 5th percentile female. Exercise countermeasures must maintain maximal pullover and bench press strength to allow pilots to reach and operate controls during lunar reentry. Reaching will not be possible during ascent abort conditions. Flight controls should be built into armrests or flight control must be accomplished by autonomous systems during acceleration exceeding 4.6G.

Schaffner, Grant↗

A Constant-Force Resistive Exercise Unit

A constant-force resistive exercise unit (CFREU) has been invented for use in both normal gravitational and microgravitational environments. In comparison with a typical conventional exercise machine, this CFREU weighs less and is less bulky: Whereas weight plates and associated bulky supporting structures are used to generate resistive forces in typical conventional exercise machines, they are not used in this CFREU. Instead, resistive forces are generated in this CFREU by relatively compact, lightweight mechanisms based on constant-torque springs wound on drums. Each such mechanism is contained in a module, denoted a resistive pack, that includes a shaft for making a torque connection to a cable drum. During a stroke of resistive exercise, the cable is withdrawn from the cable drum against the torque exerted by the resistance pack. The CFREU includes a housing, within which can be mounted one or more resistive pack(s). The CFREU also includes mechanisms for engaging any combination of (1) one or more resistive pack(s) and (2) one or more spring(s) within each resistive pack to obtain a desired level of resistance.

Colosky, Paul↗

Advanced Resistive Exercise Device

The advanced resistive exercise device (ARED), now at the prototype stage of development, is a versatile machine that can be used to perform different customized exercises for which, heretofore, it has been necessary to use different machines. Conceived as a means of helping astronauts and others to maintain muscle and bone strength and endurance in low-gravity environments, the ARED could also prove advantageous in terrestrial settings (e.g., health clubs and military training facilities) in which many users are exercising simultaneously and there is heavy demand for use of exercise machines.

Raboin, Jasen↗

Oxygen Uptake Responses to Submaximal Exercise Loads Do Not Change During Long-Duration Space Flight

In previous publications we have reported that the heart rate (HR) responses to graded submaximal exercise tests are elevated during long-duration International Space Station (ISS) flights. Furthermore, the elevation in HR appears greater earlier, rather than later, during the missions. A potential confounder in the interpretation of HR results from graded exercise tests on ISS is that the cycle ergometer used (CEVIS) is vibration-isolated from the station structure. This feature causes the CEVIS assembly to sway slightly during its use and debriefing comments by some crewmembers indicate that there is a "learning curve" associated with CEVIS use. Therefore, one could not exclude the possibility that the elevated HRs experienced in the early stages of ISS missions were related to a lowered metabolic efficiency of CEVIS exercise that would raise the submaximal oxygen uptake (VO2) associated with graded exercise testing work rates.

Moore, Alan D., Jr.↗

Temporal Changes in Left Ventricular Mechanics: Impact of Bed Rest and Exercise

The use of more sensitive and specific echocardiographic techniques such as speckle tracking imaging may address the current limitations of conventional cardiac imaging techniques to provide insight into the extent and time course of cardiac deconditioning following spaceflight or headdown tilt bed rest (HDTBR). METHODS Speckle tracking assessment of longitudinal, radial, and circumferential strain and twist was used to evaluate the impact of 70 days of HDTBR (n=7) and HDTBR + exercise (n=11) on temporal changes in LV mechanics. Echocardiograms were performed pre (BR‐2), during (BR31, 70), and following (BR+4hr) HDTBR. Repeated measures ANOVA was used to evaluate the effect of HDTBR on cardiac variables in control and exercise subjects. RESULTS After sedentary HDTBR, longitudinal (‐19.0 +/- 1.8% vs. ‐14.9 +/- 2.4%) and radial (15.0 +/- 1.9% vs. 11.3 +/- 2.2%) strain and twist (18.0 +/- 4.0deg vs. 17.0 +/- 3.6deg) were significantly impaired. In contrast, exercise preserved LV mechanics, and there were non‐significant improvements from BR‐2 to BR70 in longitudinal strain (‐18.7 +/- 1.5% vs. ‐20.4 +/- 2.7%), radial strain (13.2 +/- 2.4% vs. 14.2 +/- 1.6%), and twist (16.3 +/- 3.6deg vs. 18.6 +/- 5.9deg). CONCLUSIONS Using speckle tracking echocardiography provides important new insights into temporal changes in LV mechanics during disuse and exercise training.

Scott, J. M.↗

Transit Reconfigurable Exerciser - Intern Exit Abstract

The Transit Resistive Exerciser (TREX) was developed during a 16 week period in which a clutch device filled with smart material was built and began the testing phase. The clutch serves as a passive method of creating resistance. When paired with a series of springs, the device creates a rowing machine also capable of resistive exercise configurations. The device has loading profiles similar to the exercise devices used on the International Space Station today. The prototype created was designed in a modular fashion to support parallel development on various aspects of the project. Hardware and software are currently in development and make use of commercially available parts. Similar technologies have been used in the automotive industry but have never been explored in the context of countermeasure systems for space flight. If the work done leads to successful testing and further development, this technology has the potential to cut the size and weight of exercise devices by an order of magnitude or more.

Gebara, Christine A.↗

Temporal Changes in Left Ventricular Mechanics: Impact of Bed Rest and Exercise

BACKGROUND Current techniques used to assess cardiac function following spaceflight or head-down tilt bed rest (HDTBR) involve invasive and time consuming procedures such as Swan-Ganz catheterization or cardiac magnetic resonance imaging. An alternative approach, echocardiography, can monitor cardiac morphology and function via sequential measurements of left ventricular (LV) mass and ejection fraction (EF). However, LV mass and EF are insensitive measures of early (subclinical) cardiac deconditioning, and a decrease in LV mass and EF become evident only once significant deconditioning has already occurred. The use of more sensitive and specific echocardiographic techniques such as speckle tracking imaging may address the current limitations of conventional cardiac imaging techniques to provide insight into the magnitude and time course of cardiac deconditioning. METHODS Speckle tracking assessment of longitudinal, radial, and circumferential strain and twist was used to evaluate the impact of 70 days of HDTBR (n=7) and HDTBR + exercise (n=11) on temporal changes in LV mechanics. Echocardiograms were performed pre (BR-2), during (BR31, 70), and following (BR+4hr) HDTBR. Multi-level modeling was used to evaluate the effect of HDTBR condition (Control, Exercise) on cardiac variables. RESULTS Compared to BR-2, longitudinal (BR-2: - 19.0 +/- 1.8%; BR31: -15.9 +/- 2.4%; BR70: -14.9 +/- 2.4%; BR+4hr: -16.0 +/- 2.1%) and radial (BR-2: 15.0 +/- 1.9%; BR31: 12.3 +/- 2.4%; BR70: 11.3 +/- 2.2%; BR+4hr: 13.5 +/- 2.5% ) strains were significantly impaired during and following bed rest (p<0.05), while twist (BR-2: 18.0 +/- 4.0deg; BR31: 18.1 +/- 3.8deg; BR70: 17.0 +/- 3.6deg; BR+4hr:18.1 +/- 4.3deg) was significantly decreased at BR70 (p<0.05). In contrast, exercise preserved LV mechanics for longitudinal strain (BR-2: -19.1 +/- 1.5%; BR 31: -19.0 +/- 2.4%; BR70: -19.1 +/- 2.7%; BR+4hr: -17.8 +/- 2.1%), radial strain (BR-2: 13.8 +/- 2.4; BR31: 14.7 +/- 2.4; BR70: 14.4 +/- 1.6; BR+4hr: 14.4 +/- 2.4), and twist (BR-2: 17.8 +/- 3.6deg; BR31: 18.0 +/- 3.6deg; BR70: 18.2 +/- 5.9deg; BR+4hr: 18.3 +/- 4.2deg). CONCLUSIONS Speckle-tracking echocardiography provides important new insight into temporal changes in LV mechanics during disuse and exercise training.

Scott, Jessica M.↗

Computational Modeling Using OpenSim to Simulate a Squat Exercise Motion

Long duration space travel to destinations such as Mars or an asteroid will expose astronauts to extended periods of reduced gravity. Astronauts will use an exercise regime for the duration of the space flight to minimize the loss of bone density, muscle mass and aerobic capacity that occurs during exposure to a reduced gravity environment. Since the area available in the spacecraft for an exercise device is limited and gravity is not present to aid loading, compact resistance exercise device prototypes are being developed. Since it is difficult to rigorously test these proposed devices in space flight, computational modeling provides an estimation of the muscle forces, joint torques and joint loads during exercise to gain insight on the efficacy to protect the musculoskeletal health of astronauts.

Human Factors Engineering↗

Full Body Loading for Small Exercise Devices Project

Protecting astronauts' spine, hip, and lower body musculoskeletal strength will be critical to safely and efficiently perform physically demanding vehicle egress, exploration, and habitat building activities necessary to expand human presence in the solar system. Functionally limiting decrements in musculoskeletal health are likely during Mars proving-ground and Earth-independent missions given extended transit times and the vehicle limitations for exercise devices (low-mass, small volume). Most small exercise device concepts are designed with single-cable loading, which inhibits the ability to perform full body exercises requiring two-point loading at the shoulders. Shoulder loading is critical to protect spine, hip, and lower body musculoskeletal strength. We propose a novel low-mass, low-maintenance, and rapid deploy pulley-based system that can attach to a single-cable small exercise device to enable two-point loading at the shoulders. This attachment could protect astronauts' health and save cost, space, and energy during all phases of the Journey to Mars.

Downs, Meghan↗

Designing for Reliability and Robustness in International Space Station Exercise Countermeasures Systems

As spaceflight durations have increased over the last four decades, the effects of microgravity on the human body have become far better understood, as have the exercise countermeasures. Through use of a combination of aerobic and resistive exercise devices, today's astronauts and cosmonauts are able to partially counter the losses in muscle strength, aerobic fitness, and bone strength that otherwise might occur during their missions on the International Space Station (ISS). Since 2000, the ISS has employed a variety of exercise equipment used as countermeasures to these risks. Providing reliable and available exercise systems has presented significant challenges due to the unique environment. In solving these, lessons have been learned that can inform development of future systems.

Moore, Cherice↗

Virtual Exercise Training Software System

The purpose of this study was to develop and evaluate a virtual exercise training software system (VETSS) capable of providing real-time instruction and exercise feedback during exploration missions. A resistive exercise instructional system was developed using a Microsoft Kinect depth-camera device, which provides markerless 3-D whole-body motion capture at a small form factor and minimal setup effort. It was hypothesized that subjects using the newly developed instructional software tool would perform the deadlift exercise with more optimal kinematics and consistent technique than those without the instructional software. Following a comprehensive evaluation in the laboratory, the system was deployed for testing and refinement in the NASA Extreme Environment Mission Operations (NEEMO) analog.

Vu, L.↗

Results of an In-Field Validation Exercise in Support of Wide-Area Environmental Sampling

The National Nuclear Security Administration’s (NNSA) Office of Nonproliferation and Arms Control (NA-24) is evaluating Wide-Area Environmental Sampling (WAES) as an additional safeguards verification tool for the International Atomic Energy Agency to detect undeclared nuclear activities. The NNSA is evaluating strategies for conducting a generic WAES campaign, the cost of a WAES campaign, and the effect of technological advancements that have occurred since the last major WAES review in 1999. Until now, the NNSA effort has focused on tabletop exercises (TTXs) in which high-performance computing allows for advanced modeling and simulation efforts to be applied to the WAES question. Although the modeling and simulations used in the TTXs are extremely valuable, field campaigns are still needed to validate the assumptions that underpin the models and the modeling process itself. During a 7 week period beginning in May 2023 and ending in June 2023, which included 4 weeks of active field collections, a multilaboratory team conducted its first in-field validation exercise. Prior to the in-field exercise, abbreviated TTXs were conducted to estimate the performance of all collection systems to be used during the field test. These TTXs guided the selection of materials to be released and the placement of the collection system. Based on these determinations, materials were procured to use in the field test, and an injection/release system was designed, built, and installed at the test facility. Background samples were collected during weeks one and four, and environmental collections against active releases were conducted during weeks two and three. The goals of this validation exercise included a demonstration of (1) the ability to provide controlled releases of particulates of surrogate materials, (2) the fielding and operation of collection systems (including deposition and active air collectors), and (3) the flexibility to revise equipment and campaign plans in the field. This paper presents the results and preliminary conclusions for this initial validation test. Based on these results, subsequent field campaigns are anticipated and will include the addition of other released materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ampk alpha2 T172 activation dictates exercise performance and energy transduction in skeletal muscle

Adenosine 5′-monophosphate–activated protein kinase (AMPK) is an energetic sensor for metabolic regulation and integration. Here, we used CRISPR-Cas9 to generate nonactivatable Ampkα knock-in (KI) mice with mutation of threonine-172 phosphorylation site to alanine (T172A), circumventing the limitations of previous genetic interventions that disrupt the protein stoichiometry. KI mice of Ampkα2, but not Ampkα1, demonstrated phenotypic changes with increased fat-to-lean mass, impaired endurance exercise capacity, and diminished mitochondrial maximal respiration and conductance in skeletal muscle. Integrated temporal multiomics analysis (proteomics/phosphoproteomics/metabolomics) in skeletal muscle at rest and during exercise establishes a pleiotropic yet imperative role of Ampkα2 T172 activation for glycolytic and oxidative metabolism, mitochondrial respiration, and contractile function. There is a substantial overlap of skeletal muscle proteomic changes in Ampkα2 T172A KI mice with that of patients with type 2 diabetes. Our findings suggest that Ampkα2 T172 activation is critical for exercise performance and energy transduction in skeletal muscle and may serve as a therapeutic target for type 2 diabetes.

Bioenergetics↗