Search NASA⌕ Search

SEARCH · Search NASA

Results for “Explosion Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Expanding Coherent Array Processing to Larger Apertures Using Empirical Matched Field Processing

We have adapted matched field processing, a method developed in underwater acoustics to detect and locate targets, to classify transient seismic signals arising from mining explosions. Matched field processing, as we apply it, is an empirical technique, using observations of historic events to calibrate the amplitude and phase structure of wavefields incident upon an array aperture for particular repeating sources. The objective of this project is to determine how broadly applicable the method is and to understand the phenomena that control its performance. We obtained our original results in distinguishing events from ten mines in the Khibiny and Olenegorsk mining districts of the Kola Peninsula, for which we had exceptional ground truth information. In a cross-validation test, some 98.2% of 549 explosions were correctly classified by originating mine using just the Pn observations (2.5-12.5 Hz) on the ARCES array at ranges from 350-410 kilometers. These results were achieved despite the fact that the mines are as closely spaced as 3 kilometers. Such classification performance is significantly better than predicted by the Rayleigh limit. Scattering phenomena account for the increased resolution, as we make clear in an analysis of the information carrying capacity of Pn under two alternative propagation scenarios: free-space propagation and propagation with realistic (actually measured) spatial covariance structure. The increase in information capacity over a wide band is captured by the matched field calibrations and used to separate explosions from very closely-spaced sources. In part, the improvement occurs because the calibrations enable coherent processing at frequencies above those normally considered coherent. We are investigating whether similar results can be expected in different regions, with apertures of increasing scale and for diffuse seismicity. We verified similar performance with the closely-spaced Zapolyarni mines, though discovered that it may be necessary to divide event populations from a single mine into identifiable subpopulations. For this purpose, we perform cluster analysis using matched field statistics calculated on pairs of individual events as a distance metric. In our initial work, calibrations were derived from ensembles of events ranging in number to more than 100. We are considering the performance now of matched field calibrations derived with many fewer events (even, as mentioned, individual events). Since these are high-variance estimates, we are testing the use of cross-channel, multitaper, spectral estimation methods to reduce the variance of calibrations and detection statistics derived from single-event observations. To test the applicability of the technique in a different tectonic region, we have obtained four years of continuous data from 4 Kazakh arrays and are extracting large numbers of event segments. Our initial results using 132 mining explosions recorded by the Makanchi array are similar to those obtained in the European Arctic. Matched field processing clearly separates the explosions from three closely-spaced mines located approximately 400 kilometers from the array, again using waveforms in a band (6-10 Hz) normally considered incoherent for this array. Having reproduced ARCES-type performance with another small aperture array, we have two additional objectives for matched field processing. We will attempt to extend matched field processing to larger apertures: a 200 km aperture (the KNET) and, if data permit, to an aperture comprised of several Kazakh arrays. We also will investigate the potential of developing matched field processing to roughly locate and classify natural seismicity, which is more diffuse than the concentrated sources of mining explosions that we have investigated to date.

58 GEOSCIENCES↗

Valve Health Monitoring System Utilizing Smart Instrumentation

The valve monitoring system is a stand alone unit with network capabilities for integration into a higher level health management system. The system is designed for aiding in failure predictions of high-geared ball valves and linearly actuated valves. It performs data tracking and archiving for identifying degraded performance. The data collection types are cryogenic cycles, total cycles, inlet temperature, body temperature torsional strain, linear bonnet strain, preload position, total travel and total directional changes. Events are recorded and time stamped in accordance with the IRIG B True Time. The monitoring system is designed for use in a Class 1 Division II explosive environment. The basic configuration consists of several instrumentation sensor units and a base station. The sensor units are self contained microprocessor controlled and remotely mountable in three by three by two inches. Each unit is potted in a fire retardant substance without any cavities and limited to low operating power for maintaining safe operation in a hydrogen environment. The units are temperature monitored to safeguard against operation outside temperature limitations. Each contains 902-928 MHz band digital transmitters which meet Federal Communication Commission's requirements and are limited to a 35 foot transmission radius for preserving data security. The base-station controller correlates data from the sensor units and generates data event logs on a compact flash memory module for database uploading. The entries are also broadcast over an Ethernet network. Nitrogen purged National Electrical Manufactures Association (NEMA) Class 4 enclosures are used to house the base-station

Jensen, Scott L.↗

Sensitivity of Seismically Cued Antineutrino Detectors to Nuclear Explosions

Here, we evaluate the sensitivity of large gadolinium-doped water detectors to antineutrinos released by nuclear-fission explosions, using updated signal and background models and taking advantage of the capacity for seismic observations to provide an analysis trigger. Under certain realistic conditions, the antineutrino signature of a 250-kton pure-fission explosion could be identified several hundred kilometers away, in a detector about the size of the largest module currently proposed for a basic physics experiment. In principle, such an observation could provide rapid confirmation that the seismic signal coincided with a fission event, possibly useful for international monitoring of nuclear-weapon tests. We discuss the limited potential for seismically cued antineutrino observations to constrain fission yield, differentiate pure fission from fusion-enhanced weapon tests, indicate that the seismic evidence of an explosion had been intentionally masked, or verify the absence of explosive testing in a targeted area. We conclude that advances in seismic monitoring and neutrino physics have made the detection of explosion-derived antineutrinos more conceivable than previously asserted, but the size and cost of sufficiently sensitive detectors continue to limit applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

UNESE Phase 2: Injection and measurement of gaseous tracers at U-12p Tunnel

In June 2018 radioactive ( 37 Ar and 127 Xe) and stable (SF 6 ) tracers were injected into the chimney of the Disko Elm underground nuclear explosion, located in the U-12p tunnel complex. After the injection sampling was performed from locations within the tunnel, a borehole drilled from the surface, and from the surface of the mesa. Additionally, the 127 Xe activity within the chimney was continuously monitored for two months after the injection. While none of the injected radiotracers were detected in the monitoring borehole, elevated levels of 39 Ar (an activation product produced by underground nuclear explosions) were detected and quantified in each sample.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fusing geophysical signatures of locally recorded surface explosions to improve blast detection

We recorded acoustic, seismic and radio-frequency signatures of 70 solid charge (~2–12 kg) surface explosions (shots) at local distances (0.1–1.5 km) to determine if such signals could be fused for blast monitoring. We observed that each geophysical signature was sufficiently repeatable between similar shots to be identifiable with multichannel correlation detectors. Using template signals from a large explosion, we then processed heavily contaminated data recording a smaller shot with these detectors, and missed or marginally detected the resultant target signals. By then fusing the p-values of these statistics through Fisher's combined probability test, we clearly identified the same explosion signals at thresholds consistent with the false alarm on noise rates of the correlation detectors. This resulting Fisher test thereby provided high-probability detections, zero false alarms and higher theoretical detection capability.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

An Aquatic Acoustic Metrics Interface Utility for Underwater Sound Monitoring and Analysis

Fishes and other marine mammals suffer a range of potential effects from intense sound sources generated by anthropogenic underwater processes such as pile driving, shipping, sonars, and underwater blasting. Several underwater sound recording devices (USR) were built to monitor the acoustic sound pressure waves generated by those anthropogenic underwater activities, so the relevant processing software becomes indispensable for analyzing the audio files recorded by these USRs. However, existing software packages did not meet performance and flexibility requirements. In this paper, we provide a detailed description of a new software package, named Aquatic Acoustic Metrics Interface (AAMI), which is a Graphical User Interface (GUI) designed for underwater sound monitoring and analysis. In addition to the general functions, such as loading and editing audio files recorded by USRs, the software can compute a series of acoustic metrics in physical units, monitor the sound's influence on fish hearing according to audiograms from different species of fishes and marine mammals, and batch process the sound files. The detailed applications of the software AAMI will be discussed along with several test case scenarios to illustrate its functionality.

47 OTHER INSTRUMENTATION↗

Geologic Assessment of the Damage Zone from Two Explosions at the Source Physics Experiment

Explosive tests are being conducted in fractured granite in Nevada to increase the understanding of certain basic physical phenomena associated with underground explosions. These tests, collectively known as the Source Physics Experiment (SPE), are designed to study the generation and propagation of seismic waves. The results will help advance the seismic monitoring capability of the United States by improving the predictive capability of physics-based modeling of explosive phenomena (Snelson et al., 2012). Three of seven planned tests have been conducted to date. All the tests have been conducted in the same source hole.

seismic modeling, Nevada National Security Site↗

Low Yield Nuclear Monitoring Physics Experiment 1 – Integrated Data Acquisition System Design and Initial Observations

The report documents the design of the Integrated Data AcQuisition (IDAQ) system and observations recorded during the first in a series of underground chemical explosions conducted on the Nevada National Security Site (NNSS) in southern Nevada. Experiments are funded as part of Low Yield Nuclear Monitoring (LYNM) research and development within the United States National Nuclear Security Administration NA-22 nuclear non-proliferation program. The series is part of the broader Physical Experiment 1 (PE1) being conducted in and around the P-tunnel facility on the NNSS. Each explosive experiment utilizes several tons of comp-B to generate signals recorded by a broad suite of instrumentation. The IDAQ serves as the backbone for all subsurface instrumentation providing precise time synchronization, remote control, data exfiltration and backup, along with recording several sensing modalities throughout the underground complex that includes ground motion, environmental conditions, and electromagnetic signals.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Yield and Emplacement Depth Effects on Acoustic Signals from Buried Explosions in Hard Rock

Subterranean energy releases such as explosions and earthquakes may disturb the Earth-atmosphere interface, creating acoustic waves that can travel great distances. These waves provide a record of the ground motion directly above the event. The information they encode may provide critical insight into the depth and size of underground explosions, the sequence of events immediately before volcanic eruptions, and the magnitude of strong motion resulting from earthquakes. However, the effect of event size and burial depth on the resulting acoustic wave has not been explored in detail. The relationship between acoustic amplitude, frequency, and energy is investigated for a series of well-characterized underground chemical explosions in granite. Acoustic amplitude was found to vary linearly with explosive yield divided by emplacement depth. Peak acoustic frequency appears to be a function of explosive yield alone. The ratio of radiated acoustic energy to source energy had a relatively poor fit to yield, depth, and combinations thereof. These relationships suggest that acoustic analysis can be used to determine the size and depth of a buried explosion. The results presented here have particular relevance to the nuclear monitoring community, because depth is difficult to determine with seismic methods.

58 GEOSCIENCES↗

Optical Microsystems for Molecular Sensing (CRADA Final Report)

As part of the Cyclotron Road program, NuSight Photonics sought to implement and investigate an optical Raman spectroscopy instrument for material and molecular analysis. Raman spectroscopy is widely used for quick and non-invasive material measurement when accurate results are needed – e.g., for monitoring manufacturing process in pharmaceutical plants, or identifying illicit substances and explosives by Law Enforcement. This technique is also growing rapidly in popularity as it is applied successfully to a broad range of applications, from pathology and non-invasive early cancer detection, to food and drug safety. The biggest challenge for Raman spectroscopy to achieve its full potential is the hardware cost, ranging from $\$ $25k to $\$ $250k, with the lower cost solutions significantly limited in sensitivity—or detection limit. NuSight Photonics aimed to tackle this obstacle through a novel hardware approach: Swept-Source Raman Spectroscopy.

36 MATERIALS SCIENCE↗

Formal Verification of Safety Properties for Aerospace Systems Through Algorithms Based on Exhaustive State-Space Exploration

The Runway Safety Monitor (RSM) designed by Lockheed Martin is part of NASA's effort to reduce aviation accidents. We developed a Petri net model of the RSM protocol and used the model checking functions of our tool SMART to investigate a number of safety properties in RSM. To mitigate the impact of state-space explosion, we built a highly discretized model of the system, obtained by partitioning the monitored runway zone into a grid of smaller volumes and by considering scenarios involving only two aircraft. The model also assumes that there are no communication failures, such as bad input from radar or lack of incoming data, thus it relies on a consistent view of reality by all participants. In spite of these simplifications, we were able to expose potential problems in the RSM conceptual design. Our findings were forwarded to the design engineers, who undertook corrective action. Additionally, the results stress the efficiency attained by the new model checking algorithms implemented in SMART, and demonstrate their applicability to real-world systems. Attempts to verify RSM with NuSMV and SPIN have failed due to excessive memory consumption.

Ciardo, Gianfranco↗

Formal Verification of the Runway Safety Monitor

The Runway Safety Monitor (RSM) designed by Lockheed Martin is part of NASA's effort to reduce runway accidents. We developed a Petri net model of the RSM protocol and used the model checking functions of our tool SMART to investigate a number of safety properties in RSM. To mitigate the impact of state-space explosion, we built a highly discretized model of the system, obtained by partitioning the monitored runway zone into a grid of smaller volumes and by considering scenarios involving only two aircraft. The model also assumes that there are no communication failures, such as bad input from radar or lack of incoming data, thus it relies on a consistent view of reality by all participants. In spite of these simplifications, we were able to expose potential problems in the RSM conceptual design. Our findings were forwarded to the design engineers, who undertook corrective action. Additionally, the results stress the efficiency attained by the new model checking algorithms implemented in SMART, and demonstrate their applicability to real-world systems.

Siminiceanu, Radu↗

Measurements of Worldwide Radioxenon Backgrounds - The "EU" Project

Under the Comprehensive Nuclear-Test-Ban Treaty (CTBT), radioactive xenon (radioxenon) measurements are one of the principle techniques used to detect nuclear underground nuclear explosions, and specifically, the presence of one or more radioxenon isotopes allows one to determine whether a suspected event was a nuclear explosion or originated from an innocent source. During the design of the International Monitoring System (IMS), which was designed as the verification mechanism for the Treaty, it was determined that radioxenon measurements should be performed at 40 or more stations worldwide. At the time of the design of the IMS, however, very few details about the background of the xenon isotopes was known and it is now recognized that the backgrounds were probably evolving anyhow. This paper lays out the beginning of a study of the worldwide concentrations of xenon isotopes that can be used to detect nuclear explosions and several sources that also release radioxenons, and will have to be accounted for during analysis of atmospheric levels. Although the global concentrations of the xenon isotopes are the scope of a much larger activity that could span over several years, this study measures radioxenon concentrations in locations where there was either very little information or there was a unique opportunity to learn more about emissions from known sources. The locations where radioxenon levels were measured and reported are included.

background measurements↗

Codes for "Shallow Soil Response to a Buried Chemical Explosion with Geophones and Distributed Acoustic Sensing" DAG - 01101646

The codes reproduce the figures of the manuscript entitled "Shallow Soil Response to a Buried Chemical Explosion with Geophones and Distributed Acoustic Sensing" submitted to Journal of Geophysical Research - Solid Earth. Geophone data and Distributed acoustic sensing (DAS) data recorded during the Phase II of the The Source Physics Experiment (SPE) along a fiber-optic cable offshore were processed to understand the response of the shallow subsurface to an explosion. This Ground-based Nuclear Detonation Detection (GNDD), Low Yield Nuclear Monitoring (LYNM), and Source Physics Experiment (SPE) research was funded by the National Nuclear Security Administration, Defense Nuclear Nonproliferation Research and Development (NNSA DNN R&D).

Viens, Loic↗

2015 Groundwater Monitoring and Inspection Report Gnome-Coach, New Mexico, Site

The Gnome-Coach, New Mexico, Site was the location of a 3-kiloton-yield underground nuclear test in 1961 and a groundwater tracer test in 1963. The U.S. Geological Survey conducted the groundwater tracer test using four dissolved radionuclides--tritium, iodine-131, strontium-90, and cesium-137--as tracers. Site reclamation and remediation began after the underground testing, and was conducted in several phases at the site. The New Mexico Environment Department (NMED) issued a Conditional Certificate of Completion in September 2014, which documents that surface remediation activities have been successfully completed in accordance with the Voluntary Remediation Program. Subsurface activities have included annual sampling and monitoring of wells at and near the site since 1972. These annual monitoring activities were enhanced in 2008 to include monitoring hydraulic head and collecting samples from the onsite wells USGS-4, USGS-8, and LRL-7 using the low-flow sampling method. In 2010, the annual monitoring was focused to the monitoring wells within the site boundary. A site inspection and annual sampling were conducted on January 27-28, 2015. A second site visit was conducted on April 21, 2015, to install warning/notification signs to fulfill a requirement of the Conditional Certificate of Completion that was issued by the NMED for the surface.

54 ENVIRONMENTAL SCIENCES↗

Next generation fire suppressants

Spectrex, Inc., located in Cedar Grove, NJ is a manufacturer of fire detection and suppression equipment. Spectrex is one of the original pioneers in high speed fire detection and suppression systems for combat vehicles. Spectrex has installed fire suppressions systems in thousands of combat vehicles and ships throughout the world. Additionally, they manufacture flame explosion detectors, ship damage control systems, and optical gas and vapor detectors. The culmination of several years of research and development has recently produced an innovative electro-optical continuous monitoring systems called SharpEye 20/20I IR(sup 3) and SAFEYE that provide fast and reliable gas, vapor, aerosol, flame, and explosion detection. SharpEye 20/20I IR(sup 3) is a self-contained triple spectrum flame detector which scans for oscillating IR radiation (1 to 10 Hz) in the spectral bands ranging from 4.0 to 5.0 microns and uses programmed algorithms to check the ratio and correlation of data received by the three sensors to make the system highly immune to false alarms. It is extremely sensitive as it can detect a 1 x 1 square foot gasoline pan fire at 200 feet in less than 3 seconds. The sensitivity is user programmable, offering 4 ranges of detection. SAFEYE is comprised of a selected number of multispectral ban microprocessors controlled detectors which are in communication with one or more radiation sources that is projected along a 600 feet optical path. The signals from the selected narrow bands are processed and analyzed by highly sophisticated algorithms. It is ideal for high risk, remote, large areas such as petroleum and chemical manufacturing sites, waste dumps, aircraft cargo bays, and ship compartments. The SAFEYE will perform direct readings of the presence or rate of rise of concentrations of gases, vapors, or aerosols at the range of parts per million and provide alarms at various set points at different levels of concentrations.

Brown, Jerry A.↗

Environmental sampling at Amchitka and Adak Islands, Alaska - 15317

Amchitka Island is near the western end of the Aleutian Islands, approximately 2157 km (1340 miles) west-southwest of Anchorage, Alaska. The US government conducted three underground nuclear tests on Amchitka between 1965 and 1971 and has conducted biological monitoring on the island since before 1965; the most recent monitoring occurred in the summer of 2011. A working group of stakeholders collected samples of marine biota, sediment, and sea water for analysis of test-related radionuclides to determine if subsistence- and commercial-catch seafood in the ocean near Amchitka and Adak Island (a reference area) is safe to eat. Dietary intake information for the risk estimates used a range of diets based on published surveys of four Aleut villages and a composite diet. The risk estimates indicated that seafood harvested at Amchitka and Adak is considered safe for consumption at the intake levels for each of five diets evaluated. Although increased cesium concentrations (Cs-134) possibly related to the Fukushima Dai-ichi event were detected in certain samples; the increased levels have not resulted in unacceptable risk from the ingestion of these seafoods. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗