Search NASA⌕ Search

SEARCH · Search NASA

Results for “FOILS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

CRADA Number NFE-18-07342 with Lux Semiconductors, LLC (CRADA Final Report)

Lux Semiconductors is a flexible microelectronics startup developing a new class of Systemon-Foil electronics for rapidly emerging Internet-of-Things (IoT) markets. By leveraging its patent pending breakthrough in thin-film recrystallization, Lux is able to produce highly crystalline and flexible silicon substrates on a thin metal backing. This novel platform allows for high-speed silicon circuitry to be patterned directly into the substrate alongside low-cost printed electronics. The System-on-Foil approach has potential to enable the fabrication and integration of all core IoT functionality, including microprocessors, sensors, antennas, interconnects, and power supplies, required to enable highly durable, low profile, flexible electronics.

42 ENGINEERING↗

Adapting LEU-Modified Cintichem Process for Processing Up to 750 Grams of Uranium Targets

Argonne National Laboratory (Argonne) developed a low-enriched uranium (LEU)-modified Cintichem (LMC) process to enable production and purification of fission-produced molybdenum-99 (Mo-99) from LEU foil targets. This separation scheme starts with nitric acid (HNO 3 ) dissolution of irradiated LEU foil targets that yields an approximate final volume of 2 L. The dissolved uranium solution containing fission products, including Mo-99, is then treated by loading the solution on a titania-based recovery column to separate Mo-99 from bulk uranium. After several washing steps, Mo and other fission products are stripped from the titania column using sodium hydroxide (NaOH). The eluate is then acidified using nitric acid and subsequently processed for final purification using the LMC process. Uranium and most fission products are not adsorbed on the titania column but are eluted (i.e., removed using a solvent) during the wash steps; they can be purified and recycled into new uranium targets.

07 ISOTOPE AND RADIATION SOURCES↗

Requirements Description of EvaluateFlux

This report presents the modeling and simulation capabilities of Argonne National Laboratory’s EvaluateFlux code [1] that is used in present reactor analysis activities. These capabilities will then be used to establish the set of EvaluateFlux verification tasks necessary to verify EvaluateFlux for usage on commercial projects. A similar approach was taken for the PERSENT, REBUS and DIF3D software packages. The EvaluateFlux program is a post-processing utility program for DIF3D, specifically DIF3D-VARIANT. As covered in [1], the EvaluateFlux program was built to allow users to obtain flux and power traverses through the domain. Its primary purpose was to facilitate foil analysis by evaluating the flux solution from DIF3D-VARIANT and combining it with foil cross section data. The outputs from EvaluateFlux are contained in four possible output files: FluxAndRegionRR.out, IsotopeMicroRR.out, LabeledRegionRR.out, and IsotopeMacroRR.out. Each file is focused on using the flux evaluate and cross section data in a different manner and all are covered in this verification process.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Hot Forging Options for Thick Castings

Uranium alloyed with 10 wt% molybdenum (U-10Mo) is a monolithic nuclear fuel relevant to the National Nuclear Security Administration’s nonproliferation efforts. Research has been underway to optimize processing techniques for the U-10Mo fuel. This study investigated the use of hot compression or “hot forging” on a thick (~1") cast and homogenized U-10Mo plate before standard hot and cold rolling procedures. After plates were cast and homogenized, six samples were cut and forged at 700°C at a strain rate of either 0.10 s –1 or 0.01 s –1 at six levels of reduction. After forging, all samples underwent hot and cold rolling followed by annealing to achieve a final foil thickness of about 0.0085". Samples were taken at each stage of the casting and thermomechanical processing to assess the microstructural evolution. Chemical composition, microstructure, and uranium carbide morphology are presented and assessed in this study. Upon hot forging, dislocations accumulate along the grain boundaries, which serve as nucleation sites for randomly oriented, strain-free grains during subsequent annealing steps. Hot forging and subsequent annealing produced very heterogeneous grain sizes. However, no molybdenum segregation was observed after forging. No obvious trend was observed between forging conditions (strain rate and reduction percentage) and the microstructure after final thermomechanical processing. Upon hot rolling to 0.04" and annealing (700°C for 45 min), the average grain diameters from OM was 17 ± 2 µm across the six different forged samples. The subsequent cold rolling to 0.0085" and then annealing (700°C for 45 min) resulted in an average of 13 ± 2 µm between the six samples. Thus, the starting, as-forged microstructure did not appear to significantly influence the final microstructure of the cold-rolled foil. These results will help with understanding and expanding hot working capabilities for thicker U-10Mo castings. They also provide useful information on the effects of hot forging and its potential use to minimize defects that can arise during subsequent hot and cold rolling procedures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Verification of EvaluateFLux Utility Program

The EvaluateFlux program is a post-processing utility program for DIF3D, specifically DIF3D-VARIANT which handles Cartesian and hexagonal geometries. The EvaluateFlux program was developed to allow users to obtain flux and power traverses through the geometry domain, and its initial purpose was to facilitate foil analysis by evaluating the flux solution from DIF3D-VARIANT and combining it with foil cross section data. The EvaluateFlux program can calculate the neutron flux, as well as the reaction rates, at any user provided evaluation point. It does this by identifying the spatial mesh associated with the evaluation point and then evaluates the polynomial based neutron flux moments stored in the NHFLUX file at that point. The output of EvaluateFlux varies depending on the input setup. The maximum output includes the neutron flux and microscopic and macroscopic reaction rates at each evaluation point. The purpose of this work is to verify the outputs of EvaluateFlux. Simple models that have hand calculatable results are first defined and used to verify the EvaluateFlux outputs. More complex cases are then added where a duplicate program of EvaluateFlux that uses PrintTables outputs of the binary files is used to verify the EvaluateFlux outputs. In those complex cases, hand calculations of selected evaluation points were also displayed to confirm the software verification. For all the tests done, the hand calculations agreed well with those calculated by EvaluateFlux. For the larger complex problems, the duplicate program that can process hundreds of evaluation points was able to identify that zero points within some meshes have large errors. This aspect was attributed to the truncation error on the input provided to the duplicate program and is not a concern for the accuracy of the EvaluateFlux software.

97 MATHEMATICS AND COMPUTING↗

Reaction Rate Ratios for Recent Fast Metal Experiments with Large Plutonium Masses

Reaction rate ratios are integral responses that are used within the criticality experiments field because they contain spectral information. While these types of measurements have been utilized for nuclear data validation with historic experiments, few experiments of this type have been utilized for recent experiments, as few exist. This work focuses on measured reaction rate ratios for two nearly bare plutonium critical assemblies with different geometries: one that is cube like (with a Pu mass of 40 kg) and one that is slab like (with a Pu mass of 109 kg). Irradiations were performed with both configurations in which foils were placed near the center of the assembly. Plutonium, highly enriched uranium, depleted uranium, and Au foils were included in the irradiation and counted via high-purity germanium detectors. From these measurements, reaction rate ratios were calculated. Measured and simulated values and uncertainties are presented for the reaction rate ratios. Ratios utilizing the following reactions are given in this work: 197 Au(n, γ), 197 Au(n,2n), 235 U(n,fission), 238 U(n, fission), 238 U(n,2n), 238 U(n,γ), and 239 Pu(n,fission). Uncertainties for the measured reaction rate ratios ranged from 4% to 7%, and the contribution of various parameters to this uncertainty was investigated. The results are compared to historical experiments and should be used for nuclear data validation for future nuclear data library releases. These measurements are part of the EUCLID (Experiments Underpinned by Computational Learning for Improvements in Nuclear Data) project, which utilizes measurement responses in addition to k eff (such as these reaction rate ratios) to help reduce uncertainties in 239 Pu nuclear data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Photon Doppler Velocimetry to Spatially Resolve Plasma Density in a Power Flow Gap

The understanding of power flow plasmas is important as we look towards next generation pulsed power (NGPP) as current losses could prohibit the goals of that facility. Therefore, it is important to have accurate diagnostics of the plasma parameters on the current machines, which can be used to help inform and improve simulations. Having these plasma parameters will help validate models and simulations to provide confidence when they are expanded to conditions relevant to NGPP. One important plasma parameter that can be measured is the electron density, which can be measured by photonic Doppler velocimetry (PDV). A PDV system has several key advantages over other interferometers by measuring relatively low densities (> 1 × 10 15 cm -2 ) with both spatial and temporal resolution. Experiments were performed on the Mykonos pulsed power machine, which is a 1 MA sub scale machine in which recent platforms have been developed to explore current densities relevant to the inner magnetically insulated transmission line (MITL) on the Z machine. Experiments were performed on two different platforms, the thin foil platform and the Mykonos parallel plate platform (MP3). In addition, a combination of both single-point and multi-point measurements were used. The single-point measurements proved to be very promising, providing a clear increase in density at about 70 ns into the current rise on thin foil experiments up to about 5 × 10 17 cm -3 before the probe stopped providing signal. While we did also see returns from multi-point measurements on both platforms, the signals were not as easy to interpret due to strong background effects. However, they do show initial promise for this diagnostic to measure density at several points across a 1 mm gap. These measurements provide insights in how to improve the diagnostic so that it can provide useful information on power flow relevant experiments.

47 OTHER INSTRUMENTATION↗

A Data-driven approach to Core Power distribution reconstruction in a Nuclear Reactor

This report presents the initial development of a data-driven approach for reconstructing the core power distribution in a nuclear reactor (power shape synthesis) using ex-core sensors. Traditional techniques rely on deploying a large number of detectors throughout the reactor core. However, this approach is not feasible for innovative reactor concepts like Advanced Reactors and Microreactors. First, the tight lattice pitch, designed to maximize power density, limits the space available for sensors. Secondly, the harsh operating conditions are not compatible with commercially available detectors. The method proposed in this work integrates high-fidelity modeling with data-driven techniques to accurately reconstruct power distribution across various reactor types, thereby reducing the reliance on in-core sensors. Purdue University Reactor One (PUR-1) was selected as the test case. The CAD model representing the latest configuration of the PUR-1 core was imported into the OpenMC simulation framework, and the model was built. Additionally, the previously developed MCNP6 model was updated. The two models were assessed against the data collected during an experimental campaign conducted in July 2024. Thirty gold foils were placed in three Irradiation Assemblies in PUR-1 core. Using the measured activity of the irradiated foils, the neutron flux at different core locations was estimated.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Verification of the EvaluateFlux Utility Program

The EvaluateFlux program is a post-processing utility program for DIF3D, specifically DIF3D-VARIANT which handles Cartesian and hexagonal geometries. The EvaluateFlux program was developed to allow users to obtain flux and power traverses through the geometry domain, and its initial purpose was to facilitate foil analysis by evaluating the flux solution from DIF3D-VARIANT and combining it with foil cross section data. The EvaluateFlux program can calculate the neutron flux, as well as the reaction rates, at any user provided evaluation point. It does this by identifying the spatial mesh associated with the evaluation point and then evaluates the polynomial based neutron flux moments stored in the NHFLUX file at that point. The output of EvaluateFlux varies depending on the input setup. The maximum output includes the neutron flux and microscopic and macroscopic reaction rates at each evaluation point. The purpose of this work is to verify the outputs of EvaluateFlux. Simple models that have hand calculatable results are first defined and used to verify the EvaluateFlux outputs. More complex cases are then added where a duplicate program of EvaluateFlux that uses PrintTables outputs of the binary files is used to verify the EvaluateFlux outputs. In those complex cases, hand calculations of selected evaluation points were also displayed to confirm the software verification. For all the tests done, the hand calculations agreed well with those calculated by EvaluateFlux. For the larger complex problems, the duplicate program that can process hundreds of evaluation points was able to identify that zero points within some meshes have large errors. This aspect was attributed to the truncation error on the input provided to the duplicate program and is not a concern for the accuracy of the EvaluateFlux software.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Resonant Slow Extraction Simulation using Bmad

Simulations of slow extraction and transport of charged particle beams from synchrotrons requires careful modeling and experimentation. In this paper, we outline how the Bmad modeling software was adapted and developed to run third-integer resonant extraction simulations of beams at Brookhaven National Laboratory’s Booster synchrotron. Further, we show experimental comparisons of the slowly extracted beams transferred to the NASA Space Radiation Laboratory (NSRL) transport line. In this process, beam passes through a stripping foil element at the extraction point, which, along with stripping remaining electrons from the beam ions, acts as a scatterer to modify the phase space, moving to a more Gaussian-like distribution. This modification to the beam helps generate a uniform beam at the beam line’s target location; which is necessary for the variety of experiments performed at the facility. During this work, beam energy loss and multiple scattering by foil routines were built in conjunction with the Bmad code developers and are now integrated into the software.

43 PARTICLE ACCELERATORS↗

Preliminary Look at the LBEG & MPEG Beam Transmissions between HPSim and Operation Data

This report summarizes recent work on estimating the transmission of LANSCE H- beams from the end of the present DTL to both the PSR stripper foil (LBEG) and WNR target 4 (MPEG). The LBEG beam might be considered a more typical LINAC beam and lends itself to continuous monitoring of transmission through the various stages of the accelerator. For the MPEG, however, the widely-spaced micropulses and lack of the requisite sensitivity current monitors throughout the accelerator make these measurements extremely difficult and more uncertain. Therefore, to assist in estimating the MPEG beam transmission, beam-dynamics simulations using HPSim were employed. These beam transmission estimates from the end of the Drift Tube Linac (DTL) to Target 4 (MPEG) and the PSR stripper foil (LBEG) are vital to determine the charge requirements for LAMP’s front end. In this technote, we demonstrate three major efforts in determining the transmission: (1) Convert the WNR beamline lattice from TRANSPORT to HPSim for use in the simulation; (2) Simulate the optimization process in the Central Control Room (CCR) that brings down the losses by up to a factor of 4000 between the end of the initial physics-based tuneup phase and production beam operation; (3) Analyze operational data to deduce measured transmissions. Table 1 shows the estimated losses with HPSim and operational analysis. Finally, a better measurement and other improvements to refine the results are also proposed.

43 PARTICLE ACCELERATORS↗

Multiplexing Focusing Analyzer for Efficient Stress-Strain Measurements

Statement of the problem or situation that is being addressed. Although thermal and cold neutron scattering is widely used and is critical for success in many areas of materials science and engineering, relatively low neutron fluxes severely limit applications of not only laboratory neutrons generators, but also large national neutron facilities. State-of-the-art thermal and cold neutron sources are large expensive national facilities, which serve diverse community of scientific and industrial users. The constant need to improve the instruments performance, stems from the fact that neutron methods are gaining in popularity, and becoming more and more powerful, while new neutron sources are not being constructed to keep pace with the developments and needs of the scientific community. Small research reactors at universities and National Labs, and laboratory-based neutron generators, are necessary not only for education and training, but also when samples cannot be transported to other facilities. However, the standard neutron techniques, which were developed for high-flux facilities, require much higher efficiencies to be used effectively with the low fluxes of small sources. Thus, the efficient use of neutron sources, such as with our proposed analyzer, is important for the progress and broader use of these neutron techniques. General statement of how this problem is being addressed. We propose to design and demonstrate novel diffractive optical device, which will enable very efficient residual stress neutron diffractometers. The proposed device will be a multi-foil analyzer, where each foil is constructed of focusing bent single crystals of Si. Such device will enable polychromatic residual stress neutron diffraction. At large national facilities, such as at Oak Ridge National Laboratory, these analyzers would enable very fast measurements for determining residual stress tensors, raster large samples or screen multiple samples. Commercial Applications and Other Benefits The outcome of this project would be the demonstration of commercial devices, novel neutron optical components, which could be utilized to improve the performance of existing instruments or build novel neutron scattering instruments at DOE neutron facilities and commercial laboratory neutron sources. These new devices will widen the scope of research conducted using neutrons and enable measurements not feasible at present. Summary for Members of Congress Thermal and cold neutron beams are a powerful materials science probe, which provide unique information about the structure of matter. The proposed innovations expand the reach of neutron-based investigations to new materials and industries by enabling new instrumentation capabilities, thereby greatly enhancing and expanding the role of small, laboratory-based neutron instrumentation, and improving education and training of neutron users.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Bacteroidetes Aequorivita sp. and Kaistella jeonii Produce Promiscuous Esterases With PET-Hydrolyzing Activity

Certain members of the Actinobacteria and Proteobacteria are known to degrade polyethylene terephthalate (PET). Here, we describe the first functional PET-active enzymes from the Bacteroidetes phylum. Using a PETase-specific Hidden-Markov-Model- (HMM-) based search algorithm, we identified several PETase candidates from Flavobacteriaceae and Porphyromonadaceae. Among them, two promiscuous and cold-active esterases derived from Aequorivita sp. (PET27) and Kaistella jeonii (PET30) showed depolymerizing activity on polycaprolactone (PCL), amorphous PET foil and on the polyester polyurethane Impranil ® DLN. PET27 is a 37.8 kDa enzyme that released an average of 174.4 nmol terephthalic acid (TPA) after 120 h at 30°C from a 7 mg PET foil platelet in a 200 μl reaction volume, 38-times more than PET30 (37.4 kDa) released under the same conditions. The crystal structure of PET30 without its C-terminal Por-domain (PET30ΔPorC) was solved at 2.1 Å and displays high structural similarity to the Is PETase. PET30 shows a Phe-Met-Tyr substrate binding motif, which seems to be a unique feature, as Is PETase, LCC and PET2 all contain Tyr-Met-Trp binding residues, while PET27 possesses a Phe-Met-Trp motif that is identical to Cut190. Microscopic analyses showed that K. jeonii cells are indeed able to bind on and colonize PET surfaces after a few days of incubation. Homologs of PET27 and PET30 were detected in metagenomes, predominantly aquatic habitats, encompassing a wide range of different global climate zones and suggesting a hitherto unknown influence of this bacterial phylum on man-made polymer degradation.

59 BASIC BIOLOGICAL SCIENCES↗

Titanium Nitride as an Intermetallic Diffusion Barrier for Hydrogen Permeation in Palladium–Vanadium Composite Membranes

Hydrogen purification is a critical industrial process, and there are ongoing efforts to develop low-cost alternatives to palladium foil membranes. Titanium nitride (TiN) is studied as an interdiffusion barrier to enable hydrogen permeation in composite palladium–vanadium membranes. TiN was deposited via reactive sputtering, and films with the desired (200) orientation were obtained in the metallic regime at 400 °C under a 200 V bias to the substrate. The permeability of thin-film TiN was determined with palladium-based sandwich structures. TiN layers up to 10 nm resulted in a minimal decrease in flux (~20%) relative to a freestanding PdCu foil, which was attributed to the interfacial resistance. At greater thicknesses, the TiN layer was rate-limiting, and it was found that the effective permeability of the sputtered TiN thin films was ~6 × 10−12 mol s−1 m−1 Pa−0.5. Composite Pd|TiN|V|TiN|Pd membranes exhibited permeability values up to three times greater than pure palladium, exhibiting stability at 450 °C for over 100 h, with the lack of intermetallic diffusion and alloy formation being confirmed with XRD. The membranes were unstable at 500 °C, which was attributed to the instability of the thin Pd layer and loss of catalytic activity.

Biochemistry & Molecular Biology↗

Flux Sensor Measurement and Calibration Requirements for High-Intensity Heat Flux Applications: A Trade Study

Stakeholders of CSP and non-CSP high-intensity broadband flux measurements were surveyed and interviewed to obtain flux sensor design and calibration requirements. Existing sensor technologies and existing calibration facilities were then compared against this standard. Stakeholders require a flux sensor designed for >5,000 kW/m2 flux measurements, >1,000 life cycles, <500 ms response time, >60-minute exposure at maximum flux, and <5% measurement uncertainty. Stakeholders also require a sensor with minimal cost, short procurement lead time, and a high-intensity broadband flux calibration. Commercial CSP stakeholders primarily rely on infrared (IR) temperature measurements of receiver equipment to control CSP plant process operation, whereas CSP research and development (R&D) and non-CSP stakeholders rely on accurate flux gauge measurements for a variety of applications. It was determined that existing flux sensor technologies and calibration facilities do not comprehensively meet stakeholder needs. This study suggests a more robust circular foil gauge with a high-intensity solar flux calibration comprehensively meets stakeholder flux measurement needs. Improved circular foil gauge designs and an improved flux sensor calibration facility are discussed.

McLaughlin, Luke (ORCID:0000000303711310)↗

Ice nucleation measurements from DRUM impactors during TRACER campaign in the Houston TX region from July to September 2022

During TRACER, three Davis Rotating Uniform size-cut Monitors (DRUM; DRUMAir 4-DRUM) were used to collect aerosols for ice nucleation measurements in the Brooks laboratory at Texas A&M University. The three instruments were located at AMF1 in La Porte, Ancillary site in Guy (ANC), and onboard the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V). ROAM-V was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (miniMPL)), and one of the Davis Rotating Uniform size-cut Monitors (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”. Each DRUM sampler was operated at a flow rate of 23 LPM. Each DRUM has four stages where the aerodynamic diameter size cuts are as follows: stage 1 larger than 3 μm, stage 2 from 3 to 1.2 μm, stage 3 from 1.2 to 0.34 μm, and stage 4 from 0.34 to 0.15 μm. Pretreated aluminum foil was used as a substrate on all stages. At AMF1 and ANC sites, the DRUMs were operated on the shared aerosol inlet, with generous support of the DOE ARM site staff. These instruments rotated 24 mm per day and only contained aluminum foil substrates. Substrates were changed weekly and transported to Texas A&M for storage in -80C freezer until analysis. The DRUM onboard ROAM-V was operated at a faster rotation rate of 150 mm per day to clearly separate the multiple deployment locations for ROAM-V. For the ROAM-V DRUM, substrates were changed every deployment and transported to Texas A&M for storage in -80C freezer until analysis. At Texas A&M, ice nucleation experiments were conducted to measure the ice nucleation temperature of the ambient aerosol samples collected from the three DRUMs using our previously established procedures (Alsante et al., 2023; Fornea et al., 2009; Matthews et al., 2023). For ice nucleation, only samples collected on stage 3 were analyzed, given that these are the most relevant size (1.2 to 0.34 μm diameter) for potential ice nucleating particles. For the AMF1 and ANC sites, we cut and analyzed 2 mm (2-hour) samples. We analyzed the time periods of the AMF1 site instrument when the ROAM-V was deployed. A 72-hour period from July 11th at 23:49 through July 15th at 1:49 was analyzed from the ANC site instrument. For the ROAM-V instrument, we separated the daily samples by site location. Between 1- and 6-hour independent samples were analyzed at each location. We also cut the ROAM-V samples in half to allow for compositional analysis of the aerosol on the other half of the substrate. All viable samples from the ROAM-V were analyzed. Analysis was done using a custom-built ice nucleation apparatus, recently updated to include an array of 16 individual samples (Matthews et al., 2023). On our experimental setup, we used 100 μL of Ultra-High-Performance Liquid Chromatography (UHPLC) water (Sigma Aldrich, >99.9% purity) to wash off the aerosol from the DRUM substrate. Then, we micropipetted 2 μL droplet samples into each of the 16 wells of the array, using hydrophobically coated microscope slides. Experiments would cycle 28 times from 10 C to -40C over a 20-hour period. During analysis of the TRACER samples, nine experiments were conducted with UHPLC water process blanks that followed an identical preparation procedure. The average freezing temperature and standard deviation for these process blanks is -27.7±2.4 C. This data was collected for ARM Field Campaign AFC07023 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu. Alsante, A. N., Thornton, D. C., & Brooks, S. D. (2023). Ice nucleation catalyzed by the photosynthesis enzyme RuBisCO and other abundant biomolecules. Communications Earth & Environment, 4(1), 51. Fornea, A. P., Brooks, S. D., Dooley, J. B., & Saha, A. (2009). Heterogeneous freezing of ice on atmospheric aerosols containing ash, soot, and soil. Journal of Geophysical Research: Atmospheres, 114(D13). DOI:10.1029/2009JD011958 Matthews, B. H., Alsante, A. N., & Brooks, S. D. (2023). Pollen Emissions of Subpollen Particles and Ice Nucleating Particles. ACS Earth and Space Chemistry.

54 ENVIRONMENTAL SCIENCES↗

Diffusion bonded silicon carbide having iridium and hermetic silicon carbide-iridium bonds

Disclosed is a hermetic bond for a joint including a first layer of silicon carbide; a second layer of silicon carbide; and a bonding layer positioned between the first layer and the second layer, wherein the bonding layer includes an iridium layer, a first reaction zone positioned between the iridium foil layer and the first layer, and a second reaction zone positioned between the iridium foil layer and the second layer, wherein the first reaction zone and the second reaction zone include iridium silicides.

Cockeram, Brian V.↗

Developing a New Criticality Safety Hands-On Training Utilizing ZPPR Plates

Nuclear criticality safety is an extremely important part of the work at Los Alamos National Laboratory (LANL). As part of the work LANL performs to continue to keep criticality safety a top priority, LANL has developed and regularly teaches nuclear criticality safety training classes for both the United States Department of Energy Nuclear Criticality Safety Program as well as internal trainings for LANL employees. A portion of the training classes is comprised of hands-on demonstrations, where students get the opportunity to handle special nuclear material at the National Criticality Experiments Research Center (NCERC). One hands-on demonstration uses the “Class foils,” thin HEU foils which are stacked with lucite moderator plates. A hand-stack is performed until the multiplication reaches the “three-quarters rule,” where the demonstration is continued remotely on a vertical lift assembly up until the system is critical. This hands-on demonstration eventually achieves a critical configuration and follows the ANS-1 guidelines on an approach to critical. Another hands-on demonstration involves handling clad plutonium and neptunium spheres, and follows procedures using criticality safety evaluations to ensure that the hands-on demonstrations remain subcritical.This hands-on demonstration also involves the use of polyethylene shells around the plutonium sphere to demonstrate how additional reflector increases the criticality of a system. This paper is focused on developing a new hands-on demonstration using Zero Power Physics Reactor (ZPPR) plates. This new hands-on demonstration will follow the ANS-8 standards as it is not desired to achieve criticality with the ZPPR plates during the hands-on demonstration. A hands-on demonstration using multiple plutonium parts will likely be more applicable to personnel who handle plutonium on a daily basis, such as LANL glovebox operators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗