The determination of measures of software reliability

Measurement of software reliability was carried out during the development of data base software for a multi-sensor tracking system. The failure ratio and failure rate were found to be consistent measures. Trend lines could be established from these measurements that provide good visualization of the progress on the job as a whole as well as on individual modules. Over one-half of the observed failures were due to factors associated with the individual run submission rather than with the code proper. Possible application of these findings for line management, project managers, functional management, and regulatory agencies is discussed. Steps for simplifying the measurement process and for use of these data in predicting operational software reliability are outlined.

Maxwell, F. D.↗

Potential for Higher Treatment Failure in Obese Patients: Correlation of Elevated Body Mass Index and Increased Daily Prostate Deviations From the Radiation Beam Isocenters in an Analysis of 1,465 Computed Tomographic Images

Purpose: Recent clinical outcome studies on prostate cancer have reported the influence of patient's obesity on the biochemical failure rates after various treatment modalities. In this study, we investigated the effect of patient's physical characteristics on prostate shift in external beam radiotherapy (EBRT) and hypothesized that there maybe a correlation between patient physique and tumor shift. Methods and Materials: A retrospective analysis was performed using data for 117 patients who received image-guided radiation therapy (IGRT) for prostate cancer between January 2005 and April 2007. A total of 1,465 CT scans were analyzed. The standard deviations (SDs) of prostate shifts for all patients, along with patient weight, body mass index (BMI), and subcutaneous adipose-tissue thickness (SAT), were determined. Spearman rank correlation analysis was performed. Results: Of the 117 patients, 26.5% were considered normal weight, 48.7% were overweight, 17.9% were mildly obese, and 6.9% were moderately to severely obese. Notably 1.3%, 1.5%, 2.0%, and 21.2% of the respective shifts were greater than 10 mm in the left-right (LR) direction for the four patient groups, whereas in the anterior-posterior direction the shifts are 18.2%, 12.6%, 6.7%, and 21.0%, respectively. Strong correlations were observed between SAT, BMI, patient weight, and SDs of daily shifts in the LR direction (p < 0.01). Conclusions: The strong correlation between obesity and shift indicates that without image-guided radiation therapy, the target volume (prostate with or without seminal vesicles) may not receive the intended dose for patients who are moderate to severely obese. This may explain the higher recurrence rate with conventional external beam radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reliability and Maintainability Data for Liquid Metal Cooling Systems

One of the coolants of interest for future fusion breeding blankets is lead-lithium. As a liquid metal it offers the advantages of high temperature operation for good station efficiency, low pressure, and moderate flow rate. This coolant is also under examination for use in test blanket modules to be used in the ITER international project. To perform reliability, availability, maintainability and inspectability (RAMI) assessment as well as probabilistic safety assessment (PSA) of lead-lithium cooling systems, component failure rate data are needed to quantify the system models. RAMI assessment also requires repair time data and inspection time data. This paper presents a new survey of the data sets that are available at present to support RAMI and PSA quantification. Recommendations are given for the best data values to use when quantifying system models.

maintainability data↗

Parts and Components Reliability Assessment: A Cost Effective Approach

System reliability assessment is a methodology which incorporates reliability analyses performed at parts and components level such as Reliability Prediction, Failure Modes and Effects Analysis (FMEA) and Fault Tree Analysis (FTA) to assess risks, perform design tradeoffs, and therefore, to ensure effective productivity and/or mission success. The system reliability is used to optimize the product design to accommodate today?s mandated budget, manpower, and schedule constraints. Stand ard based reliability assessment is an effective approach consisting of reliability predictions together with other reliability analyses for electronic, electrical, and electro-mechanical (EEE) complex parts and components of large systems based on failure rate estimates published by the United States (U.S.) military or commercial standards and handbooks. Many of these standards are globally accepted and recognized. The reliability assessment is especially useful during the initial stages when the system design is still in the development and hard failure data is not yet available or manufacturers are not contractually obliged by their customers to publish the reliability estimates/predictions for their parts and components. This paper presents a methodology to assess system reliability using parts and components reliability estimates to ensure effective productivity and/or mission success in an efficient manner, low cost, and tight schedule.

Lee, Lydia↗

Lessons Learned in Space Life Support System Testing

The earlier problems can be found and corrected, the easier and cheaper it is to fix them. Doing less testing saves cost and time but doing too little testing increases the risk of operational failures causing large costs and delays. Integrated test is necessary to determine if the subsystems work together and the overall architecture performs as intended. This report reviews the testing lessons learned from the NASA Systems Engineering Handbook, a National Research Council report, and five reviews of International Space Station (ISS) lessons learned. The five reviews all mention two important points. First, that testing should be performed on the final integrated system, one as close as possible to the intended flight system. Second, “test as you fly,” while operating as planned in an environment as close as possible to the expected flight environment. Other lessons are the need for extensive preflight ground testing, the need to establish and defend an adequate budget, the problems using protoflight hardware on ISS, and the benefit of having ISS as a zero gravity test bed. The major ISS life support systems, carbon dioxide, water recycling, and oxygen recovery, were protoflight systems with little testing before launch to ISS. The failure rates these systems have been much greater than predicted and this has caused dissatisfaction with the protoflight approach. The more costly traditional approach is building qualification and test units in addition to flight units. The test units are used to test, analyze, and fix failure modes. Other work shows that there is an optimum cost-effective intuitive appeal of a human ecosystem in space.

Life support↗

Lessons Learned in Space Life Support System Testing

The earlier problems can be found and corrected, the easier and cheaper it is to fix them. Doing less testing saves cost and time but doing too little testing increases the risk of operational failures causing large costs and delays. Integrated test is necessary to determine if the subsystems work together and the overall architecture performs as intended. This report reviews the testing lessons learned from the NASA Systems Engineering Handbook, a National Research Council report, and five reviews of International Space Station (ISS) lessons learned. The five reviews all mention two important points. First, that testing should be performed on the final integrated system, one as close as possible to the intended flight system. Second, “test as you fly,” while operating as planned in an environment as close as possible to the expected flight environment. Other lessons are the need for extensive preflight ground testing, the need to establish and defend an adequate budget, the problems using protoflight hardware on ISS, and the benefit of having ISS as a zero gravity test bed. The major ISS life support systems, carbon dioxide removal, water recycling, and oxygen recovery, were protoflight systems with little testing before launch to ISS. The failure rates of these systems have been much greater than predicted and this has caused dissatisfaction with the protoflight approach. The more costly traditional approach builds qualification and test units in addition to flight units. The test units are used to find, analyze, and fix failure modes. Other work shows that there is an optimum cost-effective amount of testing when redundant systems must have a specified reliability and confidence.

Harry W. Jones↗

Regional Nodal Involvement and Patterns of Spread Along In-Transit Pathways in Children With Rhabdomyosarcoma of the Extremity: A Report From the Children's Oncology Group;Rhabdomyosarcoma; Regional failure; In-transit nodes; Radiotherapy; Extremity

Purpose: To evaluate the incidence and prognostic factors for regional failure, with attention to the in-transit pathways of spread, in children with nonmetastatic rhabdomyosarcoma of the extremity. Methods and Materials: The Intergroup rhabdomyosarcoma studies III, IV-Pilot, and IV enrolled 226 children with rhabdomyosarcoma of the extremity. Failure at the in-transit (epitrochlear/brachial and popliteal) and proximal (axillary/infraclavicular and inguinal/femoral) lymph nodes was evaluated. The median follow-up for the surviving patients was 10.4 years. Results: Of the 226 children, 55 (24%) had clinical or pathologic evidence of either in-transit and/or proximal lymph node involvement at diagnosis. The actuarial 5-year risk of regional failure was 12%. The prognostic factors for poor regional control were female gender and lymph node involvement at diagnosis. In the 116 patients with a distal extremity primary tumor, 5% had in-transit lymph node involvement at diagnosis. The estimated 5-year incidences of in-transit and proximal nodal failure was 12% and 8%, respectively. The in-transit failure rate was 0% for patients who underwent radiotherapy and/or underwent lymph node sampling of the in-transit nodal site but was 15% for those who did not (p = .07). However, the 5-year event-free survival rate did not differ between these two groups (64% vs. 55%, respectively, p = .47). Conclusion: The high incidence of regional involvement necessitates aggressive identification and treatment of regional lymph nodes in patients with rhabdomyosarcoma of the extremity. In patients with distal extremity tumors, in-transit failures were as common as failures in more proximal regional sites. Patients who underwent complete lymph node staging with appropriate radiotherapy to the in-transit nodal site, if indicated, were at a slightly lower risk of in-transit failure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prostate-Specific Antigen at 4 to 5 Years After Low-Dose-Rate Prostate Brachytherapy Is a Strong Predictor of Disease-Free Survival

Purpose: To determine (1) the prognostic utility of prostate-specific antigen (PSA) concentration at 45 to 60 months (48mPSA) after low-dose-rate prostate brachytherapy (LDR-PB); (2) the predictors of 48mPSA; and (3) the prognostic utility of directional trends between PSA levels at 24, 36, and 48 months after LDR-PB. Methods and Materials: Between 1998 and 2008, 2223 patients with low- and intermediate-risk prostate cancer received LDR-PB monotherapy. A cohort of 1434 of these patients was identified with a documented 48mPSA and no evidence of disease relapse prior to the 48mPSA. In addition, a subset of this cohort (n=585) was identified with ≥72 months of follow-up and documented PSA values at both 24 and 36 months after implantation. Results: Median follow-up time was 76 months. Eight-year Kaplan-Meier disease-free survival (DFS) rates were 100% vs 73.4% for patients with 48mPSA ≤0.2 vs those with >0.2 ng/mL; 99.1% versus 53.8% for a 48mPSA threshold of ≤0.4 versus >0.4 ng/mL, respectively; and 97.3% versus 0% for a threshold of ≤1.0 versus >1.0 ng/mL, respectively. On multivariate analysis, the only factor predictive of DFS was 48mPSA (P<.0001). On subset analysis (n=585), 29 patients had a PSA rise (defined as >0.2 ng/mL) between 24 and 36 months, 24 patients had a rise between 36 and 48 months, and 11 patients had rises over both intervals. Failure rates in these patients were 52%, 79%, and 100%, respectively. On multivariate analysis, initial PSA, androgen deprivation therapy, and dose to 90% of the prostate significantly correlated with 48mPSA but together accounted for only ∼5% of its total variance. Conclusions: The 48mPSA after LDR-PB is highly predictive of long-term DFS. Patients with 48mPSA ≤0.4 ng/mL had a <1% risk of disease relapse at 8 years, whereas all patients with 48mPSA >1.0 ng/mL relapsed. Consecutive PSA rises of >0.2 ng/mL from 24 to 36 months and from 36 to 48 months were also highly predictive of subsequent failure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

NASA Physics of Failure (PoF) for Reliability

An item’s reliability or longevity is dependent not only on its design but also on how it is used, manufactured, tested, and the stresses it has or will experience. Stresses include operational and environmental exposures to thermal, voltage, current, age/exposure, mechanical, and radiation mechanisms. Therefore, in reliability analysis, it is important to consider the contributions of all of these factors when predicting the failure rates of components. Historically, there has been a reliance on handbook data (e.g., MIL-HDBK-217), but experience has shown that these values and distributions are not representative of actual performance (1,2). Therefore, to make more credible reliability and risk assessments for its missions, NASA must transition to estimating likelihoods of failure based on an item’s reliability/longevity factors (or the physical susceptibilities and strengths impacting the design’s performance) has or will experience, whenever possible. To facilitate this transition a “Handbook on Methodology for Physics of Failure Based Reliability Assessments” has been developed by NASA to assist in applying physics experiences or experiment physics for empirical analysis and conceptualized physics exposures or theoretical physics for deterministic analysis, to develop and aggregate realistic likelihoods of failure leading to more credible forecasts of item performance and longevity. In addition, since it is NASA’s intention that this document continues to evolve based on community lessons learned and the introduction of new assessment methodologies, NASA is encouraging and appreciates the contributions of current and future authors to maintain and enhance this handbook and its supporting case studies.

Physics of Failure↗

Body Mass Index and Prostate-Specific Antigen Failure Following Brachytherapy for Localized Prostate Cancer

Purpose: Increasing body mass index (BMI) is associated with prostate-specific antigen (PSA) failure after radical prostatectomy and external beam radiation therapy (EBRT). We investigated whether BMI is associated with PSA failure in men treated with brachytherapy for clinically localized prostate cancer. Patients and Methods: Retrospective analyses were conducted on 374 patients undergoing brachytherapy for stage T1c-T2cNXM0 prostate cancer from 1996-2001. Forty-nine patients (13%) received supplemental EBRT and 131 (35%) received androgen deprivation therapy (ADT). Height and weight data were available for 353 (94%). Cox regression analyses were performed to evaluate the relationship between BMI and PSA failure (nadir + 2 ng/ml definition). Covariates included age, race, preimplantation PSA, Gleason score, T category, percent of prescription dose to 90% of the prostate, use of supplemental EBRT, and ADT. Results: Median age, PSA, and BMI were 66 years (range, 42-80 years), 5.7 ng/ml (range, 0.4-22.6 ng/ml), and 27.1 kg/m{sup 2} (range, 18.2-53.6 kg/m{sup 2}), respectively. After a median follow-up of 6.0 years (range, 3.0-10.2 years), there were 76 PSA recurrences. The BMI was not associated with PSA failure. Six-year PSA failure rates were 30.2% for men with BMI less than 25 kg/m{sup 2}, 19.5% for BMI of 25 or greater to less than 30 kg/m{sup 2}, and 14.4% for BMI of 30 kg/m{sup 2} or greater (p = 0.19). Results were similar when BMI was analyzed as a continuous variable, using alternative definitions of PSA failure, and excluding patients treated with EBRT and/or ADT. In multivariate analyses, only baseline PSA was significantly associated with shorter time to PSA failure (adjusted hazard ratio, 1.12; 95% confidence interval, 1.05-1.20; p 0.0006). Conclusions: Unlike after surgery or EBRT, BMI is not associated with PSA failure in men treated with brachytherapy for prostate cancer. This raises the possibility that brachytherapy may be a preferred treatment strategy in obese patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intensity-Modulated Radiation Therapy for the Treatment of Squamous Cell Anal Cancer With Para-aortic Nodal Involvement

Purpose: To determine the rates of toxicity, locoregional control, distant control, and survival in anal cancer patients with para-aortic nodal involvement, treated with intensity-modulated radiotherapy (IMRT) and concurrent chemotherapy at a single institution. Methods and Materials: Between 2001 and 2007, 6 patients with squamous cell anal cancer and para-aortic nodal involvement were treated with IMRT and concurrent infusional 5-fluorouracil and cisplatin. The primary tumor was treated with a median dose of 57.5 Gy (range, 54-60 Gy), involved para-aortic, pelvic, and inguinal lymph nodes were treated with a median dose of 55 Gy (range, 50.5-55 Gy), and noninvolved nodal regions were treated with a median dose of 45 Gy (range, 43.5-45 Gy). Results: After a median follow-up of 25 months, none of the patients had a recurrence at the primary tumor, pelvic/inguinal nodes, or para-aortic nodes, whereas 2 patients developed distant metastases to the liver. Four of the 6 patients are alive. The 3-year actuarial locoregional control, distant control, and overall survival rates were 100%, 56%, and 63%, respectively. Four of the 6 patients developed Grade 3 acute gastrointestinal toxicity during chemoradiation. Conclusions: Intensity-modulated radiotherapy and concurrent chemotherapy could potentially serve as definitive therapy in anal cancer patients with para-aortic nodal involvement. Adjuvant chemotherapy may be indicated in these patients, as demonstrated by the distant failure rates. These patients need to be followed carefully because of the potential for treatment-related toxicities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-term Follow-up of the RTOG 9501/Intergroup Phase III Trial: Postoperative Concurrent Radiation Therapy and Chemotherapy in High-Risk Squamous Cell Carcinoma of the Head and Neck

Purpose: Previous analysis of this Intergroup trial demonstrated that with a median follow-up among surviving patients of 45.9 months, the concurrent postoperative administration of cisplatin and radiation therapy improved local-regional control and disease-free survival of patients who had high-risk resectable head-and-neck carcinomas. With a minimum of 10 years of follow-up potentially now available for all patients, these results are updated here to examine long-term outcomes. Methods and Materials: A total of 410 analyzable patients who had high-risk resected head-and-neck cancers were prospectively randomized to receive either radiation therapy (RT: 60 Gy in 6 weeks) or identical RT plus cisplatin, 100 mg/m{sup 2}i.v. on days 1, 22, and 43 (RT + CT). Results: At 10 years, the local-regional failure rates were 28.8% vs 22.3% (P=.10), disease-free survival was 19.1% vs 20.1% (P=.25), and overall survival was 27.0% vs 29.1% (P=.31) for patients treated by RT vs RT + CT, respectively. In the unplanned subset analysis limited to patients who had microscopically involved resection margins and/or extracapsular spread of disease, local-regional failure occurred in 33.1% vs 21.0% (P=.02), disease-free survival was 12.3% vs 18.4% (P=.05), and overall survival was 19.6% vs 27.1% (P=.07), respectively. Conclusion: At a median follow-up of 9.4 years for surviving patients, no significant differences in outcome were observed in the analysis of all randomized eligible patients. However, analysis of the subgroup of patients who had either microscopically involved resection margins and/or extracapsular spread of disease showed improved local-regional control and disease-free survival with concurrent administration of chemotherapy. The remaining subgroup of patients who were enrolled only because they had tumor in 2 or more lymph nodes did not benefit from the addition of CT to RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison Modeling of System Reliability for Future NASA Projects

A National Aeronautics and Space Administration (NASA) supported Reliability, Maintainability, and Availability (RMA) analysis team developed a unique RMA analysis methodology using cut set and importance measure analysis in order to comparison model proposed avionics computing architectures. In this paper we will present this efficient application of the RMA analysis methodology for importance measures that includes Reliability Block Diagram (RED) Analysis, Comparison modeling, Cut Set Analysis, and Importance Measure Analysis. We will also demonstrate that integrating RMA early in the system design process as a key to success by providing a fundamental decision metric supporting design selection. The RMA analysis methodology presented in this paper and applied to the avionics architectures enhances the usual way of predicting the need for redundancy based on failure rates or subject matter expert opinion. Using the REDs and the minimal cut sets, along with the Fussell-Vesely (FV) factors, importance measures are calculated for each functional element in the architectures. This paper presents an application of the FV importance measures and presents an improved methodology for using importance measures in success space (instead of failure space) to compare architectures. These importance measures are used to determine which functional element would be most likely to cause a system failure, thus, quickly identifying the path to increase the overall system reliability by either procuring more reliable functional elements or adding redundancy. This application of the RMA analysis methodology, using RBD analysis, cut set analysis, and the importance measure analysis, allows the avionics design team to better understand and compare the vulnerabilities in each of the architectures, enabling them to address the deficiencies in the design architectures more efficiently, while balancing the need to design for optimum weight and space allocations.

Gillespie, Amanda M.↗

AC and DC Fault Management for Megawatt Electrified Aircraft Electrical Powertrains Task 3: Lifetime and Reliability of Electrical Insulators

This research project was a collaborative investigation between researchers at the RTX Technology Research Center (RTRC) and the University of Texas at Austin and made a significant contribution to enabling electric aircraft. The transport of electric power between the points of generation and use requires power cables. These cables must be smaller, lighter and provide a more predictable life than power cables used in stationary applications. Consequently, this investigation provided heretofore unavailable information supporting the safety and reliability of smaller lighter power cables for electrified aircraft. In addition, the research identified key additional engineering data needed to support quantitative reliability assessments. Important advances included: • Demonstrated that at least one manufacturer can make a novel, smaller, lighter power cable that is free from serious defects. • Developed and published an appropriate analytical construct to describe the life of this novel cable. This is a necessary step for use in aviation where the understanding of remaining life is critical. • Demonstrated thermal-mechanical aging that suggested 1000+ flights before the thermal-mechanical processes produced defects large enough that the defect growth was accelerated electrically. • Showed that electrical aging took place at two rates. The first possibly lasting weeks to months and the second possibly days to weeks. If robust, this provides a good diagnostic for cable replacement. • Demonstrated that the traditional electrical testing of cable materials using manufactured voids can be misleading due to the size of the voids. Emerging laser drilling technology permitted demonstration that the physics of failure in realistically small voids is different from that in the unrealistically large voids used in earlier research, which is very important for high-quality, high-performance, small aircraft cables. Although this project represents a significant contribution to the specifics of cable aging in the aircraft environment, important additional research remains to be completed, including: • Non-uniform thermal cycling by applying the heat from the center conductor to maximize thermal stress next to the core area where the electric gradient is the strongest. This builds on the uniform thermal cycling that has been completed. • The augmentation of the thermal-mechanical failure rate by electrical processes. Better understanding of these time constants strongly affects the ability to predict life. • Termination design: Terminations provide not only electrical reflection potential, but a location for a series arc fault and an area where ozone can diffuse into the center conductor and negatively affect cable insulation. • The abrasion and ozone resistance of the cable jacket. • Pressure cycling as an accelerant of thermal, mechanical, and/or electrical aging. • Possible methods for online PD detection and offline PD localization

model↗

AGR-5/6/7 Irradiation Summary as of the End of Cycle 167A

Overall, the first three cycles of irradiation proceeded as planned Items of note: Failure rate of thermocouples was higher than expected Downstream needle valves were throttled resulting in part of the exhaust flow being diverted prior to reaching the fission product monitors (this was corrected near the end of cycle 164B). This was more of annoyance than anything and did not prevent proper analysis of fission product data. No evidence of failures on fission product monitoring system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Bayesian Analysis of Step-Stress Accelerated Life Test with Exponential Distribution

In this article, we propose a general Bayesian inference approach to the step-stress accelerated life test with type II censoring. We assume that the failure times at each stress level are exponentially distributed and the test units are tested in an increasing order of stress levels. We formulate the prior distribution of the parameters of life-stress function and integrate the engineering knowledge of product failure rate and acceleration factor into the prior. The posterior distribution and the point estimates for the parameters of interest are provided. Through the Markov chain Monte Carlo technique, we demonstrate a nonconjugate prior case using an industrial example. It is shown that with the Bayesian approach, the statistical precision of parameter estimation is improved and, consequently, the required number of failures could be reduced.

14 SOLAR ENERGY↗