Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flow Boiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Marshall Space Flight Center Faculty Fellowship Program

This paper presents a multi-node model of autogenous pressurization of liquid nitrogen in a flight tank using the Generalized Fluid System Simulation Program (GFSSP), a general purpose flow network code developed at NASA/Marshall Space Flight Center. This study considers two different models: (a) pressurization of the tank by nitrogen gas from a supply tank and (b) pressurization of the tank by using the boil-off propellant through an IVF (Integrated Vehicle Fluids) loop. The tank pressurization model considers two different liquid fill-levels of the tank (a) 75% and (b) 45%. Heat and mass transfer between the liquid and vapor has been modeled at the liquid vapor interface. Heat transfer between wall and vapor at the ullage has been accounted for by assuming heat transfer occurs by natural convection. The model also accounts for heat leak to the tank through the insulation and metal wall by heat conduction. The predicted pressures and temperatures are compared with the measured data and good agreement has been observed. In the second case, the tank is pressurized by using the boil-off fluid that recirculates through an IVF loop. Preliminary results from this model are also reported.

N.F. Six↗

Modular test system for solar collectors

Portable, recirculating-water-flow, and temperature-control device is used with solar simulator and actual sunlight to test and evaluate several solar-collector panel coatings, panel designs, and scaled-down collector subsystems. System can be pressurized to prevent boiling and allows operation above 100 degrees Centigrade.

Dolan, F. J.↗

Development of a Hybrid Single/Two-Phase Capillary-Based Micro-Cooler using Copper Inverse Opals Wick with Silicon 3D Manifold for High-Heat-Flux Cooling Application

Previously, we reported two-phase capillary-based cooling using narrow (200 to 1000 ..mu..m) heater bridge copper inverse opal (CIO) wicks with heat flux level of 1400 Wcm -2 and superheat ~ 10 degrees C. Here, we demonstrate the area scaling of the proposed technology to a large-area micro-cooler for high-heat-flux cooling of microprocessors and power electronics. We developed a hybrid single/two-phase micro-cooler that relies on capillary-wicking in a 25-..mu..m-thick CIO with an open silicon microchannel 3D-manifold for liquid delivery and vapor extraction, achieving a high heat flux ~ 400 Wcm -2 over a heated area of 10 x 10 mm 2 . For a range of inlet water flowrates from 5 to 60 g(min) -1 , we achieved total thermal resistances and vapor qualities of 0.68 cm 2 degrees CW -1 to 0.2 cm 2 degrees CW -1 and 0.55 to 0.12, respectively. The flowrates are 10x smaller than those of conventional single- or two-phase microchannel cooling technology. The corresponding two-phase thermal resistances ranges from 0.05 to 0.02 cm 2 degrees CW -1 with temperature superheat of 8 to 6 degrees C, respectively. While the overall performance of the large-area (10 x 10 mm 2 ) capillary-based micro-cooler degraded compared to the previous demonstration of the technology for a heated area of 5 x 5 mm 2 , however, preliminary CFD modeling indicates that an improved manifold design will be able to achieve comparable performance.

capillary flow↗

Zero-Boil-Off Tank (ZBOT) Experiment: Ground-Based Validation of Self-Pressurization and Pressure Control Two-Phase CFD Model

Integral to all phases of NASA's projected space and planetary expeditions is affordable and reliable cryogenic fluid storage for use in propellant or life support systems. Cryogen vaporization due to heat leaks into the tank from its surroundings and support structure can cause self-pressurization relieved through venting. This has led to a desire to develop innovative pressure control designs based on mixing of the bulk tank fluid together with some form of active or passive cooling to allow storage of the cryogenic fluid with zero or reduced boil-off. The Zero-Boil-Off Tank (ZBOT) Experiments are a series of small scale tank pressurization and pressure control experiments aboard the International Space Station (ISS) that use a transparent volatile simulant fluid in a transparent sealed tank to delineate various fundamental fluid flow, heat and mass transport, and phase change phenomena that control storage tank pressurization and pressure control in microgravity. The hardware for ZBOT-1 flew to ISS on the OA-7 flight in April 2017 and operations are planned to begin in September 2017, encompassing more than 90 tests. This paper presents preliminary results from ZBOT's ground-based research delineating both pressurization and pressure reduction trends in the sealed test tank. Tank self-pressurization tests are conducted under three modes: VJ heating, strip heating and simultaneous VJ and strip heating in attempt to simulate heat leaks from the environment, the support structure and both. The jet mixing pressure control studies are performed either from an elevated uniform temperature condition or from thermally stratified conditions following a self-pressurization run. Jet flow rates are varied from 2-25 cm/s spanning a range of jet Re number in laminar, transitional, and turbulent regimes and a range of Weber numbers covering no ullage penetration, partial penetration and complete ullage penetration and break-up (only in microgravity). Numerical prediction of a two-phase CFD model are compared to experimental 1g results to both validate the model and also indicate the effect of the residual non-condensable gas on evolution of pressure and temperature distributions in the tank during pressurization and pressure control.

microgravity evaporation condensatio↗

Acoustic Bubble Removal from Boiling Surfaces

The object of the study was the investigation of the forces generated by standing acoustic waves on vapor bubbles, both far and near boundaries. In order to accomplish this objective, in view of the scarcity of publications on the topic, it has been necessary to build an edifice of knowledge about vapor bubbles in sound and flow fields from the ground up, as it were. We have addressed problems of gradually greater difficulty as follows: 1. In the first place, the physics of an stationary isolated bubble subject to a sound field in an unbounded liquid was addressed; 2. The case of bubbles translating in a stationary pressure field was then considered; 3. This was followed by a study of the combined effects of sound and translation, 4. And of a neighboring boundary 5. Finally, a new method to deal with nonspherical bubbles was developed- In addition to the work on vapor bubbles, some studies on gas bubbles were conducted in view of NASA's interest in the phenomenon of sonoluminescence.

Prosperetti, Andrea↗

Simulation for Prediction of Entry Article Demise (SPEAD): an Analysis Tool for Spacecraft Safety Analysis and Ascent/Reentry Risk Assessment

For the purpose of performing safety analysis and risk assessment for a probable offnominal suborbital/orbital atmospheric reentry resulting in vehicle breakup, a synthesis of trajectory propagation coupled with thermal analysis and the evaluation of node failure is required to predict the sequence of events, the timeline, and the progressive demise of spacecraft components. To provide this capability, the Simulation for Prediction of Entry Article Demise (SPEAD) analysis tool was developed. This report discusses the capabilities, modeling, and validation of the SPEAD analysis tool. SPEAD is applicable for Earth or Mars, with the option for 3 or 6 degrees-of-freedom (DOF) trajectory propagation. The atmosphere and aerodynamics data are supplied in tables, for linear interpolation of up to 4 independent variables. The gravitation model can include up to 20 zonal harmonic coefficients. The modeling of a single motor is available and can be adapted to multiple motors. For thermal analysis, the aerodynamic radiative and free-molecular/continuum convective heating, black-body radiative cooling, conductive heat transfer between adjacent nodes, and node ablation are modeled. In a 6- DOF simulation, the local convective heating on a node is a function of Mach, angle-ofattack, and sideslip angle, and is dependent on 1) the location of the node in the spacecraft and its orientation to the flow modeled by an exposure factor, and 2) the geometries of the spacecraft and the node modeled by a heating factor and convective area. Node failure is evaluated using criteria based on melting temperature, reference heat load, g-load, or a combination of the above. The failure of a liquid propellant tank is evaluated based on burnout flux from nucleate boiling or excess internal pressure. Following a component failure, updates are made as needed to the spacecraft mass and aerodynamic properties, nodal exposure and heating factors, and nodal convective and conductive areas. This allows the trajectory to be propagated seamlessly in a single run, inclusive of the trajectories of components that have separated from the spacecraft. The node ablation simulates the decreasing mass and convective/reference areas, and variable heating factor. A built-in database provides the thermo-mechanical properties of For the purpose of performing safety analysis and risk assessment for a probable offnominal suborbital/orbital atmospheric reentry resulting in vehicle breakup, a synthesis of trajectory propagation coupled with thermal analysis and the evaluation of node failure is required to predict the sequence of events, the timeline, and the progressive demise of spacecraft components. To provide this capability, the Simulation for Prediction of Entry Article Demise (SPEAD) analysis tool was developed. This report discusses the capabilities, modeling, and validation of the SPEAD analysis tool. SPEAD is applicable for Earth or Mars, with the option for 3 or 6 degrees-of-freedom (DOF) trajectory propagation. The atmosphere and aerodynamics data are supplied in tables, for linear interpolation of up to 4 independent variables. The gravitation model can include up to 20 zonal harmonic coefficients. The modeling of a single motor is available and can be adapted to multiple motors. For thermal analysis, the aerodynamic radiative and free-molecular/continuum convective heating, black-body radiative cooling, conductive heat transfer between adjacent nodes, and node ablation are modeled. In a 6- DOF simulation, the local convective heating on a node is a function of Mach, angle-ofattack, and sideslip angle, and is dependent on 1) the location of the node in the spacecraft and its orientation to the flow modeled by an exposure factor, and 2) the geometries of the spacecraft and the node modeled by a heating factor and convective area. Node failure is evaluated using criteria based on melting temperature, reference heat load, g-load, or a combination of the above. The failure of a liquid propellant tank is evaluated based on burnout flux from nucleate boiling or excess internal pressure. Following a component failure, updates are made as needed to the spacecraft mass and aerodynamic properties, nodal exposure and heating factors, and nodal convective and conductive areas. This allows the trajectory to be propagated seamlessly in a single run, inclusive of the trajectories of components that have separated from the spacecraft. The node ablation simulates the decreasing mass and convective/reference areas, and variable heating factor. A built-in database provides the thermo-mechanical properties of

Ling, Lisa↗

High performance, high density hydrocarbon fuels

The fuels were selected from 77 original candidates on the basis of estimated merit index and cost effectiveness. The ten candidates consisted of 3 pure compounds, 4 chemical plant streams and 3 refinery streams. Critical physical and chemical properties of the candidate fuels were measured including heat of combustion, density, and viscosity as a function of temperature, freezing points, vapor pressure, boiling point, thermal stability. The best all around candidate was found to be a chemical plant olefin stream rich in dicyclopentadiene. This material has a high merit index and is available at low cost. Possible problem areas were identified as low temperature flow properties and thermal stability. An economic analysis was carried out to determine the production costs of top candidates. The chemical plant and refinery streams were all less than 44 cent/kg while the pure compounds were greater than 44 cent/kg. A literature survey was conducted on the state of the art of advanced hydrocarbon fuel technology as applied to high energy propellents. Several areas for additional research were identified.

Frankenfeld, J. W.↗

Experimental and CFD Investigation of the Titled Jet Behavior in the Zero Boil-Off Tank (ZBOT) Experiment

Screens are used in cryogenic storage tanks to diffuse the incoming gas or liquid injection/flow into the tank. Meshed screens were also used in the jet mixing pressure control tests of the Zero Boil-Off Tank (ZBOT) Experiment which was recently performed aboard the International Space Station (ISS). The ZBOT pressure control studies used a liquid jet that was intended to be aligned with the longitudinal axis of the tank. A cartridge consisting of a honeycomb flow straightener and two screen diffusers, one upstream of the honeycomb, and one downstream, were designed to obtain the desired velocity profile in a manner that would be consistent in all the tests and could also be used as an input to the CFD simulations. Unfortunately, during the flight operations, the Digital Particle Image Velocimetry (DPIV) measurements indicated that the jet actually exited the nozzle at an angle to the main axis. This unexpected tilt affected the motion and deformation of the ullage during the pressure control tests, influencing the initial pressure drops. Upon disassembling the experiment hardware, it was discovered that the screen diffuser upstream of the honeycomb was clogged with debris. Since this behavior is important, not only to the follow-on ZBOT-NC experiment, but also to the operation of cryogenics storage tanks in general, a series of ground-based experiments and parametric CFD model simulations were performed to understand and characterize the tilted flow in terms of the clogged area of the upstream screen and the jet velocity. The experimental and CFD results surprisingly and non-intuitively showed that although the modification of the flow originated from the clogging of the upstream screen, the presence of the downstream unclogged screen was also necessary to produce the tilted jet. Two different CFD models were used for the numerical simulations, and only the one using a porous media formulation to capture the screen pressure drop was able to produce the correct tilting behavior. Parametric runs with the porous media CFD model were used to characterize the jet tilt in terms of the blockage area and jet velocity for both the future ZBOT-NC Experiment and other propellant tank applications. Supported by NASA Biological & Physical Sciences (BPS) Division, Physical Sciences Research Program, NASA HQ, USA.

Cryogenic Fluid Management↗

Computations of turbulent evaporating sprays

A computational study of turbulent evaporating sprays is reported. The major focus is to examine the sensitivity of the vaporization behavior of turbulent sprays to the transient liquid-phase processes. Three models considered to represent these processes are the thin skin, infinite diffusion, and diffusion limit models. Favre-averaged equations with k-epsilon-g turbulence model are employed for the gas phase. The Lagrangian approach with a stochastic separated flow method is used for the liquid phase where the effects of gas turbulence on droplet trajectories and interphase transport rates are considered using random-walk computations. Also the variable-property effects are considered in detail. Results indicate that, depending upon the boiling temperature and heat of vaporization of the fuel considered, the vaporization behavior of turbulent sprays may be quite sensitive to the modeling of transient liquid-phase processes. Thus, it is important that for most hydrocarbon fuels these processes be adequately represented in any comprehensive spray computations. The present results also provide further support to the conclusions of earlier studies which have been based on simplified spray configurations.

Aggarwal, S. K.↗

LARC-IA: A flexible backbone polyimide

A new linear, aromatic, thermoplastic polyimide, prepared from oxydiphthalic anhydride (ODPA) and 3,4'-oxydianiline (ODA) in diglyme and identified as LARC-IA, was synthesized and evaluated. The monomers are relatively inexpensive and physiologically safe. Molecular weight was controlled by use of a monofunctional anhydride, phthalic anhydride (PA), in order to promote controlled flow and wetting properties. The polymer is considered a safe alternative to commercially available LARC-TPI which is prepared with an expensive diamine of uncertain carcinogenicity. The evaluation was based primarily on the polymer's adhesive properties as determined by thermal and water boil exposure of lap shear specimens. Strengths were determined at room temperature, 177, 204 and 232 C before and after exposure to determine the adhesive system's durability to adverse environments over a period of time. Other properties (FWT, G(1c), film and composite properties) were examined which were determined to be typical of a high temperature polyimide. Results of the study show a favorable comparison to LARC-TPI, a commercially available polyimide.

Progar, Donald J.↗

Control System Development for A Zero Boil-Off Hydrogen Storage Demonstration With Two-Stage Active Cooling

A NASA team is designing and building a test article to demonstrate the long duration storage of liquid hydrogen via active cooling (cryocoolers) while implementing a two-stage cooling approach. This activity is one of a large portfolio of NASA’s Space Technology Mission Directorate funded activities which focuses on the technology maturation needed for long duration storage of cryogenic liquid in-space. The current state-of-the-art for liquid hydrogen storage on-orbit is on the order of hours while NASA’s planned missions require storage for months, or even years. To enable such a long duration, Zero Boil-Off conditions must be achieved which requires passive technologies to minimize environmental heat loads, but also active cooling to intercept and reject the remaining heat to deep space. The implementation of active cooling results in a significant amount of dry mass added to the vehicle. Utilizing a Two-Stage Cooling approach, analysis and testing to date indicates the Zero Boil-Off of liquid hydrogen can be achieved with less mass and electrical power relative to a single-stage cooling approach where only one cryocooler is used. This activity will demonstrate the fully integrated suite of technologies needed to enable the Two-Stage Cooling approach which includes Multi-Layer Insulation blankets, Low Conductivity Structures, a Tube-On-Tank Heat Exchanger, Tube-On-Shield Heat Exchanger and a Two-Stage Cryogenerator (both 90 Kelvin and 20 Kelvin) with each stage having an independently controlled circulation loop. The bulk of the heat load is intercepted by the 90 Kelvin loop via a thin foil heat exchanger internal to the insulation blankets (also known as a Broad Area Cooling Shield), with the remainder removed at cryofluid temperature (20 Kelvin) by tubes directly welded to the outer tank surface. In this paper, we examine the challenges of controlling the system, and describe the development of control algorithms and software for future testing with liquid hydrogen. The interactions between the cryofans which control circulation loop mass flow rates, electrical heaters which vary the cryocooler lift to simulate the operation of variable-lift flight units, tank heaters which can vary the overall heat load, and the effects of changes in circulation loop pressure as temperatures change, can be complex and must be well understood to maintain steady-state propellant conditions and achieve Zero Boil-Off. Parallel PID loops and watchdog programs implemented on the user interface system will help bring the systems to steady state operation and keep them at selected operating points within acceptable error, while avoiding runaway feedback loops.

cryogenics↗

Small scale demand type neon liquefaction plant

Low-temperature measurement of the thermal conductivity of insulating materials is generally made using a boil-off calorimetry technique involving liquid hydrogen (LH2). Liquid neon (LNe) has nearly the same normal boiling point as LH2, but has a much larger heat of vaporization, allowing extended run times. The main drawback of using LNe has been its excessive cost; $170.00 versus $1.50/l for LH2 (1989 prices). A neon liquefaction plant has been designed and constructed to capture, purify, and refrigerate the neon boil-off from calorimetry experiments. Recycling the neon reduces operating costs to approximately $20/l. The system consists of a purification section, a heat exchanger, LNe and LH2 storage dewars, and a fully automated control system. After purification, neon is liquified in the heat exchanger by LH2 flowing countercurrently through stainless steel cooling coils. Hydrogen flow is automatically adjusted to keep the neon at its normal saturation temperature, 27 K. The liquid neon is then stored in a dewar placed directly below the heat exchanger.

Dube, W. P.↗

Oceans, Ice Shells, and Life on Europa

The four large satellites of Jupiter are famous for their planet-like diversity and complexity, but none more so than ice-covered Europa. Since the provocative Voyager images of Europa in 1979, evidence has been mounting that a vast liquid water ocean may lurk beneath the moon's icy surface. Europa has since been the target of increasing and sometimes reckless speculation regarding the possibility that giant squid and other creatures may be swimming its purported cold, dark ocean. No wonder Europa tops everyone's list for future exploration in the outer solar system (after the very first reconnaissance of Pluto and the Kuiper belt, of course). Europa may be the smallest of the Galilean moons (so-called because they were discovered by Galileo Galilei in the early 17th century) but more than makes up for its diminutive size with a crazed, alien landscape. The surface is covered with ridges hundreds of meters high, domes tens of kilometers across, and large areas of broken and disrupted crust called chaos. Some of the geologic features seen on Europa resemble ice rafts floating in polar seas here on Earth-reinforcing the idea that an ice shell is floating over an ocean on this Moon-size satellite. However, such features do not prove that an ocean exists or ever did. Warm ice is unusually soft and will flow under its own weight. If the ice shell is thick enough, the warm bottom of the shell will flow, as do terrestrial glaciers. This could produce all the observed surface features on Europa through a variety of processes, the most important of which is convection. (Convection is the vertical overturn of a layer due to heating or density differences-think of porridge or sauce boiling on the stove.) Rising blobs from the base of the crust would then create the oval domes dotting Europa's surface. The strongest evidence for a hidden ocean beneath Europa's surface comes from the Galileo spacecraft's onboard magnetometer, which detected fluctuations in Jupiter's magnetic field consistent with a conductor inside Europa. The most likely conductor: a somewhat salty ocean.

Schenk, Paul↗

Thermal effects in two-phase flow through face seals

When liquid is sealed at high temperature, it flashes inside the seal due to pressure drop and/or viscous heat dissipation. Two-phase seals generally exhibit more erratic behavior than their single phase counterparts. Thermal effects, which are often neglected in single phase seal analyses, play an important role in determining seal behavior under two-phase operation. It is necessary to consider the heat generation due to viscous shear, conduction into the seal rings and convection with the leakage flow. Analytical models developed work reasonably well at the two extremes - for low leakage rates when convection is neglected and for higher leakage rates when conduction is neglected. A preliminary model, known as the Film Coefficient Model, is presented which considers conduction and convection both, and allows continuous boiling over an extended region unlike the previous low-leakage rate model which neglects convection and always forces a discrete boiling interface. Another simplified, semi-analytical model, based on the assumption of isothermal conditions along the seal interafce, has been developed for low leakage rates. The Film Coefficient Model may be used for more accurate and realistic description.

Basu, Prithwish↗

Universal Two-Phase Convection Heat Transfer Correlations for Cryogenic Pipe Chilldown

This paper presents a set of universal two-phase convection heat transfer correlations for modeling boiling heat transfer during pipe chilldown fit over the widest available range of cryogenic fluids and thermodynamic conditions. The correlations improve upon prior correlations that were developed separately for liquid nitrogen (LN2) and liquid hydrogen (LH2) pipe quenching datasets. The new correlations include equations to calculate the single-phase vapor heat transfer, film boiling heat transfer, transition boiling heat transfer, nucleate boiling heat transfer, single-phase liquid heat transfer, bulk vapor temperature during high quality film boiling, Leidenfrost temperature, critical heat flux, critical heat flux temperature, and the onset of nucleate boiling temperature. The correlations were validated against LH2, LN2, liquid methane, liquid oxygen, and liquid argon pipe quenching datasets. The eight datasets cover the following parameter ranges: pipe lengths of 0.1 to 6.5m; outer pipe diameters of 12.7 to 25.4 mm; pipe wall thicknesses from 0.51 to 1.64 mm; flow directions of upward, downward, and horizontal; gravity levels of 1g and 0g±0.01g. A numerical model assumes homogeneous mixing between the vapor and liquid and implicitly integrates the coupled energy equations for the pipe and fluid, as well as continuity for the fluid. The model was used to estimate the equilibrium quality and fluid mass accumulation along the pipes during chilldown from estimates of the fluid-pipe heat transfer extracted from temperature measurements. The correlations can be implemented in lumped parameter codes such as SINDA/FLUINT and the Generalized Fluid System Simulation Program (GFSSP) to improve the accuracy of chilldown time and chilldown boiloff mass predictions. Such predictions are useful for designing ground or in-space cryogenic liquid transfer systems.

Universal Correlations↗

Heat Transfer Enhancement in Cryogenic Quenching Process

This paper reports a heat transfer advancement in the cryogenic quenching process. An experiment was performed to evaluate the enhancement of quenching heat transfer by the use of metal tubes with low thermal conductivity coating layers. Four coating thicknesses with various coolant mass flow rates of liquid nitrogen were investigated. The results indicated that the tube inner surface coating greatly enhanced the quenching efficiency. The quenching efficiency was found to increase with increasing number of coating layers, and the efficiency also increased with decreasing mass flow rates. In general, the efficiencies cover a range between 40.6% and 80%. Comparing to the bare surface case, the percentage increase in the quenching efficiency was the minimum at 4.2% for a single coated layer at the highest flow rate and the maximum of 109.1% for four coated layers at the lowest flow rate. The coated tubes could save up to 53% in the amount of cryogen consumption.

Surface coating↗

Modeling the Rapid Boil-Off of a Cryogenic Liquid When Injected into a Low Pressure Cavity

Many launch vehicle cryogenic applications require the modeling of injecting a cryogenic liquid into a low pressure cavity. The difficulty of such analyses lies in accurately predicting the heat transfer coefficient between the cold liquid and a warm wall in a low pressure environment. The heat transfer coefficient and the behavior of the liquid is highly dependent on the mass flow rate into the cavity, the cavity wall temperature and the cavity volume. Testing was performed to correlate the modeling performed using Thermal Desktop and Sinda Fluint Thermal and Fluids Analysis Software. This presentation shall describe a methodology to model the cryogenic process using Sinda Fluint, a description of the cryogenic test set up, a description of the test procedure and how the model was correlated to match the test results.

Fluid Mechanics↗

Combustion of Two-Component Miscible Droplets in Reduced Gravity

This paper presents recent theoretical and experimental results from an ongoing research program that deals with reduced-gravity combustion of bi-component droplets initially in the mm size range or larger. The primary objectives of the research are to study the effects of droplet internal flows, thermal and solutal Marangoni stresses, and species volatility differences on liquid species transport and overall combustion phenomena (e.g., gas-phase unsteadiness, burning rates, sooting, radiation, and extinction). The research program utilizes a reduced-gravity environment so that buoyancy effects are rendered negligible. Use of large droplets also facilitates visualization of droplet internal flows, which is important to this research. This program is a continuation of extensive ground based experimental and theoretical research on bi-component droplet combustion which has been ongoing for several years. The focal point of this research program is a flight experiment (Bi-Component Droplet Combustion Experiment, BCDCE). This flight experiment is still under development. However, supporting ground studies have been performed, and preliminary data have been obtained from flight experiments (Fiber Supported Droplet Combustion Experiment, FSDC-1 and FSDC-2). These flight experiments were performed during the STS-73/USML-2 and STS-94/MSL- I missions. In the experiments, droplets composed of low- and high-volatility species are burned. The low-volatility components are initially present in small amounts. As combustion of a droplet proceeds, the liquid surface mass fraction of the low-volatility component will increase with time, resulting in a sudden and temporary decrease in droplet burning rates as the droplet rapidly heats to temperatures close to the boiling point of the low-volatility component. This decrease in burning rates causes a sudden and temporary contraction of the flame. The decrease in burning rates and the flame contraction can be observed experimentally. Measurements of burning rates as well as the onset time for flame contraction allow effective liquid-phase species diffusivities to be calculated, e.g., using asymptotic theory. A goal of the research is to relate effective liquid species diffusivities to droplet internal flow characteristics. Droplet internal flows will be visualized in future flight and ground-based experiments.

Shaw, B. D.↗