Search NASA⌕ Search

SEARCH · Search NASA

Results for “GAMMA CAMERAS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

THE ACS FORNAX CLUSTER SURVEY. IX. THE COLOR-MAGNITUDE RELATION OF GLOBULAR CLUSTER SYSTEMS

We investigate the color-magnitude relation for globular clusters (GCs)-the so-called blue tilt-detected in the Advanced Camera for Surveys (ACS) Fornax Cluster Survey and using the combined sample of GCs from the ACS Fornax and Virgo Cluster Surveys. We find a tilt of gamma{sub z} {identical_to} d(g - z)/dz = -0.0257 +- 0.0050 for the full GC sample of the Fornax Cluster Survey ({approx}5800 GCs). This is slightly shallower than the value gamma{sub z} = -0.0459 +- 0.0048 found for the Virgo Cluster Survey GC sample ({approx}11,100 GCs). The slope for the merged Fornax and Virgo data sets ({approx}16,900 GCs) is gamma{sub z} = -0.0293 +- 0.0085, corresponding to a mass-metallicity relation of Z {proportional_to} M {sup 0.43+}-{sup 0.12}. We find that the blue tilt sets in at masses in excess of M {approx} 2 x 10{sup 5} M{sub sun}. The tilt is stronger for GCs belonging to high-mass galaxies (M{sub *} {approx}> 5 x 10{sup 10} M{sub sun}) than for those in low-mass galaxies (M{sub *} {approx}< 5 x 10{sup 10} M{sub sun}). It is also more pronounced for GCs with smaller galactocentric distances. Our findings suggest a range of mass-metallicity relations Z{sub GC} {proportional_to} M {sup 0.3-0.7}{sub GC} which vary as a function of host galaxy mass/luminosity, a scaling similar to that observed for dwarf spheroidal galaxies. We compare our observations to a recent model of star cluster self-enrichment with generally favorable results. We suggest that, within the context of this model, the protocluster clouds out of which the GCs formed may have had density profiles slightly steeper than isothermal and/or star formation efficiencies somewhat below 0.3. We caution, however, that the significantly different appearance of the color-magnitude diagrams (CMDs) defined by the GC systems associated with galaxies of similar mass and morphological type poses a challenge to any single mechanism, including self-enrichment, that seeks to explain generically the observed GC color-magnitude relations. We therefore suggest that the detailed (and stochastic) merger/accretion histories of individual galaxies have likely played a non-negligible role determining the distribution of GCs in the CMDs of individual GC systems.

79 ASTRONOMY AND ASTROPHYSICS↗

A collimated neutron detector for RFP plasmas in MST

The neutron emissivity profile in the Madison Symmetric Torus is being reconstructed through the use of a collimated neutron detector. A scintillator-photomultiplier tube (PMT) system is employed to detect the fusion neutrons with the plasma viewing volume defined by a 55 cm deep, 5 cm diameter aperture. Effective detection of neutrons from the viewing volume is achieved through neutron moderation using 1300 lbs of high density polyethylene shielding, which modeling predicts attenuates the penetrating flux by a factor of 10{sup 4} or more. A broad spectrum of gamma radiation is also present due to the unconfined fusion proton bombardment of the thick aluminum vacuum vessel. A 15 cm cylindrical liquid scintillator of 3.8 cm diameter is used to further increase directional sensitivity. A fast (5 ns rise time) preamplifier and digitization at 500 MHz prevent pulse pile-up even at high count rates (∼10{sup 4}/s). The entire neutron camera system is situated on an adjustable inclining base which provides the differing plasma viewing volumes necessary for reconstruction of the neutron emissivity profile. This profile, directly related to the fast-ion population, allows for an investigation of the critical fast-ion pressure gradient required to destabilize a neutral beam driven Alfvénic mode which has been shown to transport fast ions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

National Diagnostic Working Group (NDWG) for inertial confinement fusion (ICF)/high-energy density (HED) science: The whole exceeds the sum of its parts

The National Diagnostic Working Group (NDWG) has led the effort to fully exploit the major inertial confinement fusion/high-energy density facilities in the US with the best available diagnostics. These diagnostics provide key data used to falsify early theories for ignition and suggest new theories, recently leading to an experiment that exceeds the Lawson condition required for ignition. The factors contributing to the success of the NDWG, collaboration and scope evolution, and the methods of accomplishment of the NDWG are discussed in this Review. Examples of collaborations in neutron and gamma spectroscopy, x-ray and neutron imaging, x-ray spectroscopy, and deep-ultraviolet Thomson scattering are given. Here, an abbreviated history of the multi-decade collaborations and the present semiformal management framework is given together with the latest National Diagnostic Plan.

47 OTHER INSTRUMENTATION↗

3D track reconstruction of low-energy electrons in the MIGDAL low pressure optical time projection chamber

Here, we demonstrate three-dimensional track reconstruction of electrons in a low pressure (50 Torr) optical TPC consisting of two glass GEMs with an ITO strip readout in CF 4 and CF 4 /Ar mixtures. The reconstructed tracks show a variety of event topologies, including short tracks from photoelectrons induced by 55 Fe 5.9 keV X-rays and long tracks from gamma ray interactions and beta decays. Algorithms for event identification and track ridge detection are discussed as well as multiple methods for integrating information from the camera image and ITO waveforms with the goal of full 3D reconstruction of the track.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnosing ICF gamma-ray physics

Gamma rays produced in an ICF environment open up a host of physics opportunities we are just beginning to explore. A branch of the DT fusion reaction, with a branching ratio on the order of 2e-5 {gamma}/n, produces 16.7 MeV {gamma}-rays. These {gamma}-rays provide a direct measure of fusion reaction rate (unlike x-rays) without being compromised by Doppler spreading (unlike neutrons). Reaction-rate history measurements, such as nuclear bang time and burn width, are fundamental quantities that will be used to optimize ignition on the National Ignition Facility (NIF). Gas Cherenkov Detectors (GCD) that convert fusion {gamma}-rays to UV/visible Cherenkov photons for collection by fast optical recording systems established their usefulness in illuminating ICF physics in several experimental campaigns at OMEGA. Demonstrated absolute timing calibrations allow bang time measurements with accuracy better than 30 ps. System impulse response better than 95 ps fwhm have been made possible by the combination of low temporal dispersion GCDs, ultra-fast microchannel-plate photomultiplier tubes (PMT), and high-bandwidth Mach Zehnder fiber optic data links and digitizers, resulting in burn width measurement accuracy better than 10ps. Inherent variable energy-thresholding capability allows use of GCDs as {gamma}-ray spectrometers to explore other interesting nuclear processes. Recent measurements of the 4.44 MeV {sup 12}C(n,n{prime}) {gamma}-rays produced as 14.1 MeV DT fusion neutrons pass through plastic capsules is paving the way for a new CH ablator areal density measurement. Insertion of various neutron target materials near target chamber center (TCC) producing secondary, neutron-induced {gamma}y-rays are being used to study other nuclear interactions and as in-situ sources to calibrate detector response and DT branching ratio. NIF Gamma Reaction History (GRH) diagnostics, based on the GCD concept, are now being developed based on optimization of sensitivity, bandwidth, dynamic range, cost, and NIF-specific logistics, requirements and extreme radiation environment. Implementation will occur in two phases: (1) four PMT-based channels mounted to the outside of the target chamber at {approx}6m from TCC (GRH-6m) for the 3e13-3e16 DT neutron yield range expected during the early ignition-tuning campaigns; and (2) several channels located just inside the target bay shield wall at 15 m from TCC (GRH-15m) with optical paths leading through the cement shield wall to well-shielded streak cameras and PMTs for the 1e16-1e20 yield range expected during the DT ignition campaign. Multiple channels at each phase will allow for increased redundancy, reliability, accuracy and flexibility. This suite of diagnostics will make possible exploration of interesting {gamma}-ray physics well beyond the ignition campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Psychophysical Calibration of Mobile Touch-Screens for Vision Testing in the Field

The now ubiquitous nature of touch-screen displays in cell phones and tablet computers makes them an attractive option for vision testing outside of the laboratory or clinic. Accurate measurement of parameters such as contrast sensitivity, however, requires precise control of absolute and relative screen luminances. The nonlinearity of the display response (gamma) can be measured or checked using a minimum motion technique similar to that developed by Anstis and Cavanagh (1983) for the determination of isoluminance. While the relative luminances of the color primaries vary between subjects (due to factors such as individual differences in pre-retinal pigment densities), the gamma nonlinearity can be checked in the lab using a photometer. Here we compare results obtained using the psychophysical method with physical measurements for a number of different devices. In addition, we present a novel physical method using the device's built-in front-facing camera in conjunction with a mirror to jointly calibrate the camera and display. A high degree of consistency between devices is found, but some departures from ideal performance are observed. In spite of this, the effects of calibration errors and display artifacts on estimates of contrast sensitivity are found to be small.

gamma correction↗

Large scale telescopes for high resolution X-ray and gamma-ray astronomy

This paper shows that angular-resolution, energy-range, and structural constraints on image-modulated X-ray telescopes are not fundamental and that the limits on angular resolution can be overcome by constructing such telescopes on a very large spatial scale. It is proposed that widely separated satellites be used for the modulating mask and detector array. Implementation of this concept is discussed in terms of a simple system consisting of a pinhole camera (i.e., a hole in an opaque mask on one subsatellite and a detector array on another). Advantages and problems of such systems are briefly discussed, and a solar X-ray telescope intended for deployment from a Shuttle orbiter is described. It is noted that such large-scale telescopes can be constructed to image gamma rays and even energetic neutrons as well.

Hudson, H. S.↗

Mapping of inhomogeneous quasi-3D electrostatic field in electro-optic materials

Abstract This paper describes a new method for direct measurement and evaluation of the inhomogeneous electrostatic vector field with translational symmetry in electro-optic materials exhibiting the Pockels effect. It is based on the evaluation of maximum transmittance of low intensity light passing through a sample under a voltage bias. Here, the sample is located between rotating crossed polarizers, and camera images are obtained at each point to determine the electric field. The evaluation procedure is demonstrated using data acquired on a CdZnTeSe quasi-hemispheric semiconductor gamma-ray detector. In addition to CdTe-related compounds, the method can be used for various other materials showing $$\overline{4}3m$$ 4 ¯ 3 m symmetry such as GaAs, CdTe, GaP, 3C-SiC, and ZnS. Furthermore, it can be generalized to other crystalline materials showing the Pockels effect. The method can be used to probe the space charge and the electric field in several kinds of electronic components and devices, as well as provide useful data on the role of defects, contact configurations and other surface and bulk inhomogeneities in the material that can affect the distribution of the internal electric field.

36 MATERIALS SCIENCE↗

EVIDENCE OF CROSS-CORRELATION BETWEEN THE CMB LENSING AND THE γ-RAY SKY

We report the measurement of the angular power spectrum of cross-correlation between the unresolved component of the Fermi-LAT γ-ray sky maps and the cosmic microwave background lensing potential map reconstructed by the Planck satellite. The matter distribution in the universe determines the bending of light coming from the last scattering surface. At the same time, the matter density drives the growth history of astrophysical objects, including their capability at generating non-thermal phenomena, which in turn give rise to γ-ray emissions. The Planck lensing map provides information on the integrated distribution of matter, while the integrated history of γ-ray emitters is imprinted in the Fermi-LAT sky maps. We report here the first evidence of their correlation. We find that the multipole dependence of the cross-correlation measurement is in agreement with current models of the γ-ray luminosity function for active galactic nuclei and star-forming galaxies, with a statistical evidence of 3.0σ. Moreover, its amplitude can in general be matched only assuming that these extragalactic emitters are also the bulk contribution of the measured isotopic γ-ray background (IGRB) intensity. This leaves little room for a big contribution from galactic sources to the IGRB measured by Fermi-LAT, pointing toward direct evidence of the extragalactic origin of the IGRB.

79 ASTRONOMY AND ASTROPHYSICS↗

Finding Fast Transients in Real Time Using a Novel Light-curve Analysis Algorithm

The current data acquisition rate of astronomical transient surveys and the promise for significantly higher rates in the next decade necessitate the development of novel approaches to analyze astronomical data sets and promptly detect objects of interest. The Deeper, Wider, Faster (DWF) program is a survey focused on the identification of fast-evolving transients, such as fast radio bursts, gamma-ray bursts, and supernova shock breakouts. It employs multifrequency simultaneous coverage of the same part of the sky over several orders of magnitude. Using the Dark Energy Camera mounted on the 4 m Blanco telescope, DWF captures a 20 s g -band exposure every minute, at a typical seeing of ~1'' and an air mass of ~1.5. These optical data are collected simultaneously with observations conducted over the entire electromagnetic spectrum—from radio to γ -rays—as well as cosmic-ray observations. In this paper, we present a novel real-time light-curve analysis algorithm, designed to detect transients in the DWF optical data; this algorithm functions independently from, or in conjunction with, image subtraction. We present a sample of fast transients detected by our algorithm, as well as a false-positive analysis. Our algorithm is customizable and can be tuned to be sensitive to transients evolving over different timescales and flux ranges.

79 ASTRONOMY AND ASTROPHYSICS↗

Space environmental effects on adhesives for the Galileo spacecraft

Requirements for the adhesives used on the Galileo Jovian probe are discussed, and the results of mechanical and radiation experiments for their qualification are presented. The five types of adhesives used for the Wide Field Camera, SXA Antenna, temperature control louvers, and structural bonds all passed the proton and electron tests and the low temperature radiation tests. Possible bond improvements through techniques including gamma ray radiation exposure and ion implantation are also considered.

Bouquet, F. L.↗

GRDC. A Collaborative Framework for Radiological Background and Contextual Data Analysis

The Radiation Mobile Analysis Platform (RadMAP) is unique in its capability to collect both high quality radiological data from both gamma-ray detectors and fast neutron detectors and a broad array of contextual data that includes positioning and stance data, high-resolution 3D radiological data from weather sensors, LiDAR, and visual and hyperspectral cameras. The datasets obtained from RadMAP are both voluminous and complex and require analyses from highly diverse communities within both the national laboratory and academic communities. Maintaining a high level of transparency will enable analysis products to further enrich the RadMAP dataset. It is in this spirit of open and collaborative data that the RadMAP team proposed to collect, calibrate, and make available online data from the RadMAP system. The Berkeley Data Cloud (BDC) is a cloud-based data management framework that enables web-based data browsing visualization, and connects curated datasets to custom workflows such that analysis products can be managed and disseminated while maintaining user access rights. BDC enables cloud-based analyses of large datasets in a manner that simulates real-time data collection, such that BDC can be used to test algorithm performance on real and source-injected datasets. Using the BDC framework, a subset of the RadMAP datasets have been disseminated via the Gamma Ray Data Cloud (GRDC) that is hosted through the National Energy Research Science Computing (NERSC) Center, enabling data access to over 40 users at 10 institutions.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

TH-C-17A-03: Dynamic Visualization and Dosimetry of IMRT and VMAT Treatment Plans by Video-Rate Imaging of Cherenkov Radiation in Pure Water

Purpose: A novel optical dosimetry technique for the QA and verification of intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) radiotherapy plans was investigated for the first time by capturing images of the induced Cherenkov radiation in water. Methods: An intensified CCD camera (ICCD) was used to acquire a two-dimensional (2D) projection image of the Cherenkov radiation induced by IMRT and VMAT plans, based on the Task Group 119 C-Shape geometry. Plans were generated using the Varian Eclipse treatment planning system (TPS) and delivered using 6 MV x-rays from a Varian TrueBeam Linear Accelerator (Linac) incident on a water tank. The ICCD acquisition was gated to the Linac, operated for single pulse imaging, and binned to a resolution of 512×512 pixels. The resulting videos were analyzed temporally for regions of interest (ROI) covering the planning target volume (PTV) and organ at risk (OAR) and summed to obtain an overall light distribution, which was compared to the expected dose distribution from the TPS using a gammaindex analysis. Results: The chosen camera settings resulted in data at 23.5 frames per second. Temporal intensity plots of the PTV and OAR ROIs confirmed the preferential delivery of dose to the PTV versus the OAR, and the gamma analysis yielded 95.2% and 95.6% agreement between the light distribution and expected TPS dose distribution based upon a 3% / 3 mm dose difference and distance-to-agreement criterion for the IMRT and VMAT plans respectively. Conclusion: The results from this initial study demonstrate the first documented use of Cherenkov radiation for optical dosimetry of dynamic IMRT and VMAT treatment plans. The proposed modality has several potential advantages over alternative methods including the real-time nature of the acquisition, and upon future refinement may prove to be a robust and novel dosimetry method with both research and clinical applications. NIH R01CA109558 and R21EB017559.

07 ISOTOPE AND RADIATION SOURCES↗

MISR Browse data (MISBR_V5)

A MISR Browse Tool is available to allow easy access to ellipsoid-derived, true-color images for each camera reduced to 2.2 km resolution. The MISR red, green and blue bands are used to create the true-color image in JPEG format. The image is intentionally clipped and gamma-stretched to make cloud, ocean and land features visible. The user may find the Browse Tool helpful before ordering data. The tool's purpose is to search and view images in the on-line user interface. However, the browse product can be ordered separately. The Browse Tool page has Orbit-to-Date and Lat/Lon-to-Path/Block conversion tools to help identify particular MISR geographic locations and data files. [Temporal_Coverage: Start_Date=2000-02-24; Stop_Date=] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=2.2 km; Longitude_Resolution=2.2 km; Horizontal_Resolution_Range=1 km - < 10 km or approximately .01 degree - < .09 degree; Temporal_Resolution=about 15 orbits/day; Temporal_Resolution_Range=Daily - < Weekly].

EOSDIS↗

High-spin spectroscopy in {sup 125}Xe

Levels excited up to 39.8 MeV and 119/2 units of angular momentum have been populated in {sup 125}Xe by the {sup 82}Se({sup 48}Ca,5n){sup 125}Xe reaction. High-fold {gamma}-ray coincidence events were measured using the Gammasphere Ge detector array. Nine regular rotational bands extending from levels identified previously up to almost 60 ({h_bar}/2{pi}) have been identified, and three of these have been connected to low-lying levels having well-established spins and parities. Configurations have been assigned to six of the bands based on alignment properties, band crossings, and comparison with theoretical cranked shell model calculations (CSM). Transition quadrupole moments have been measured for these bands in the spin range 31-55 ({h_bar}/2{pi}) and were found to be in agreement with the CSM calculations. The corresponding quadrupole deformation {epsilon}{sub 2} ranges from 0.28 to 0.34 at a {gamma} deformation of 0 deg. and from 0.29 to 0.36 at a {gamma} value of 5 deg.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

NASAs Evolvable Mars Campaign: Mars Moons Robotic Precursor

Human exploration missions to the moons of Mars are being considered within NASA's Evolvable Mars Campaign (EMC) as an intermediate step for eventual human exploration and pioneering of the surface of Mars. A range of mission architectures is being evaluated in which human crews would explore one or both moons for as little as 14 days or for as long as 500 days with a variety of orbital and surface habitation and mobility options being considered. Relatively little is known about the orbital, surface, or subsurface characteristics of either moon. This makes them interesting but challenging destinations for human exploration missions during which crewmembers must be able to effectively conduct scientific exploration without being exposed to undue risks due to radiation, dust, micrometeoroids, or other hazards. A robotic precursor mission to one or both moons will be required to provide data necessary for the design and operation of subsequent human systems and for the identification and prioritization of scientific exploration objectives. This paper identifies and discusses considerations for the design of such a precursor mission based on current human mission architectures. Objectives of a Mars' moon precursor in support of human missions are expected to include: 1) identifying hazards on the surface and the orbital environment at up to 50-km distant retrograde orbits; 2) collecting data on physical characteristics for planning of detailed human proximity and surface operations; 3) performing remote sensing and in situ science investigations to refine and focus future human scientific activities; and 4) prospecting for in situ resource utilization. These precursor objectives can be met through a combination or remote sensing (orbital) and in-situ (surface) measurements. Analysis of spacecraft downlink signals using radio science techniques would measure the moon's mass, mass distribution, and gravity field, which will be necessary to enable trajectory planning. Laser altimetry would precisely measure the moon's shape and improve the accuracy of radio science measurements. A telescopic imaging camera would map the moon at submeter resolution and photograph selected areas of interest at subcentimeter resolution and a visible and near-infrared (0.4-3.0 mm) imaging spectrograph would produce a global map of mineral composition variations at a resolution of tens of meters and maps of selected areas of interest at meter resolution. Additional remote sensing capabilities could include a thermal infrared imager (heat flow, thermal inertia, and grain size distributions), a gamma-ray and neutron detector (atomic composition), a ground-penetrating radar (internal structure), and a magnetometer and Langmuir probe (magnetic properties and plasma field). Once on the surface of Phobos or Deimos, necessary instrumentation would include a penetrometer (regolith compressive strength), a motion-imagery camera (to observe the penetrometer tests before, during, and after contact), a dust-adhesion witness plate and camera (dust levitation), a microimager (dust particle sizes and shapes), and an alpha-proton-X-ray, X-ray fluorescence, Mossbauer, or Raman spectrometer (atomic and mineral composition of surface materials) and an optional temperature probe (regolith thermal properties). A variety of robotic mission design options to enable both orbital and surface measurements are being considered that include fully integrated and modular approaches. In-situ measurements from at least one surface location would be required, with additional measurement locations possible through use of multiple landers, through propulsive relocation of a single lander, or through electromechanical surface translation by a walking or hopping lander vehicle, which could also serve to evaluate such mobility capabilities for subsequent human missions. Preliminary orbital analysis suggests that remote sensing would likely be performed while in a distant retrograde orbit around the target moon. Mission design options to enable characterization of both Mars’ moons in a single mission are also being studied.

Gernhardt, Michael L.↗

MISR Browse data (MISBR_V3)

A MISR Browse Tool is available to allow easy access to ellipsoid-derived, true-color images for each camera reduced to 2.2 km resolution. The MISR red, green and blue bands are used to create the true-color image in JPEG format. The image is intentionally clipped and gamma-stretched to make cloud, ocean and land features visible. The user may find the Browse Tool helpful before ordering data. The tool's purpose is to search and view images in the on-line user interface. However, the browse product can be ordered separately. The Browse Tool page has Orbit-to-Date and Lat/Lon-to-Path/Block conversion tools to help identify particular MISR geographic locations and data files. [Location=GLOBAL] [Temporal_Coverage: Start_Date=2000-02-24; Stop_Date=] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=2.2 km; Longitude_Resolution=2.2 km; Horizontal_Resolution_Range=1 km - < 10 km or approximately .01 degree - < .09 degree; Temporal_Resolution=about 15 orbits/day; Temporal_Resolution_Range=Daily - < Weekly].

EOSDIS↗

MISR Browse data (MISBR_V4)

A MISR Browse Tool is available to allow easy access to ellipsoid-derived, true-color images for each camera reduced to 2.2 km resolution. The MISR red, green and blue bands are used to create the true-color image in JPEG format. The image is intentionally clipped and gamma-stretched to make cloud, ocean and land features visible. The user may find the Browse Tool helpful before ordering data. The tool's purpose is to search and view images in the on-line user interface. However, the browse product can be ordered separately. The Browse Tool page has Orbit-to-Date and Lat/Lon-to-Path/Block conversion tools to help identify particular MISR geographic locations and data files. [Location=GLOBAL] [Temporal_Coverage: Start_Date=2000-02-24; Stop_Date=] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=2.2 km; Longitude_Resolution=2.2 km; Horizontal_Resolution_Range=1 km - < 10 km or approximately .01 degree - < .09 degree; Temporal_Resolution=about 15 orbits/day; Temporal_Resolution_Range=Daily - < Weekly].

IMAGE↗